Session 1 01 Vogelsanger New Standards For NC Testing
Session 1 01 Vogelsanger New Standards For NC Testing
Beat Vogelsanger, Ruth Sopranetti, Beate Pausch, Marc Müller and Dominik Werfl 1
Patrick Folly 2
Mario Paquet 3
Lucas R Lopez, Lydia Chang 4
1 NITROCHEMIE WIMMIS AG, Switzerland
2 FEDERAL DEPARTMENT OF DEFENCE, armasuisse, Thun, Switzerland
3 GENERAL DYNAMICS OTS, Valleyfield, Canada
4 US DoD, ARDEC, Picatinny NJ, USA
© Nitrochemie 2012
New Standards for NC Testing – STANAG 4178 Ed. 2 / MIL-DTL-244 B/ECP / C
Contents
Introduction
History of Standards for NC Testing
Differences between STANAG 4178 Ed. 2 and MIL-DTL-244 B/ECP / C
Status of Ratification / Implementation
2012 NC Symp Spiez _ Pres Vogelsanger et al 1 _ Standards for NC Testing.ppt Vob © Nitrochemie 2012 2
New Standards for NC Testing – STANAG 4178 Ed. 2 / MIL-DTL-244 B/ECP / C
2007 – 2009
NATO/PfP AC/326 SG/1 CNG + US Industrial
Product Team (IPT) + international NC Experts
55 Persons /// 36 MoD/DoD Agencies,
Institutes, Companies /// 17 Nations
3 Joint Meetings + many Sub-Team Meetings
MIL-DTL-244B/ECP Identical
STANAG 4178 Ed. 2
(2010) Test-
Procedures (2009)
MIL-DTL-244C (2012)
2012 NC Symp Spiez _ Pres Vogelsanger et al 1 _ Standards for NC Testing.ppt Vob © Nitrochemie 2012 3
New Standards for NC Testing – STANAG 4178 Ed. 2 / MIL-DTL-244 B/ECP / C
2012 NC Symp Spiez _ Pres Vogelsanger et al 1 _ Standards for NC Testing.ppt Vob © Nitrochemie 2012 4
New Standards for NC Testing – STANAG 4178 Ed. 2 / MIL-DTL-244 B/ECP / C
Latvia
UK
Canada Czech Rep.
Spain
USA
MIL-DTL-244 C (2012)
Approved by the Nitrocellulose Configuration Manager (PM-CAS)
ARDEC standardization group is working on the document to ensure
spec language complies with DoD requirements
Not yet implemented !
2012 NC Symp Spiez _ Pres Vogelsanger et al 1 _ Standards for NC Testing.ppt Vob © Nitrochemie 2012 7
New Standards for NC Testing – STANAG 4178 Ed. 2 / MIL-DTL-244 B/ECP / C
2012 NC Symp Spiez _ Pres Vogelsanger et al 1 _ Standards for NC Testing.ppt Vob © Nitrochemie 2012 8
New Standards for NC Testing – STANAG 4178 Ed. 2 / MIL-DTL-244 B/ECP / C
2012 NC Symp Spiez _ Pres Vogelsanger et al 1 _ Standards for NC Testing.ppt Vob © Nitrochemie 2012 9
New Standards for NC Testing – STANAG 4178 Ed. 2 / MIL-DTL-244 B/ECP / C
0 2 4 6 8 10 0 5 10 15 20 25
Retention Time [Min] Retention Time [Min]
2012 NC Symp Spiez _ Pres Vogelsanger et al 1 _ Standards for NC Testing.ppt Vob © Nitrochemie 2012 10
New Standards for NC Testing – STANAG 4178 Ed. 2 / MIL-DTL-244 B/ECP / C
NC
250 mL
+ water 230
NC Source mera
large
210
- shaking 190
170
centri- Ø small
- settling 1h 150
Ø
130 fuging SR
110
90
10
800
settling 70 30
600
L = 357 µm
50
50
volume 30 3000 g 400
mL
70
200
90
Sample
Dispersing
Unit
Example Picture
Pulsed
CCD
Light
Camera
Source
2012 NC Symp Spiez _ Pres Vogelsanger et al 1 _ Standards for NC Testing.ppt Vob © Nitrochemie 2012 13
New Standards for NC Testing – STANAG 4178 Ed. 2 / MIL-DTL-244 B/ECP / C
Agglomerates can be
eliminated from analysis
2012 NC Symp Spiez _ Pres Vogelsanger et al 1 _ Standards for NC Testing.ppt Vob © Nitrochemie 2012 14
New Standards for NC Testing – STANAG 4178 Ed. 2 / MIL-DTL-244 B/ECP / C
Verteilungsdichte q1*
55.0
Sample M6 3.2
52.5
50.0 - 2 replicates measured 3 to 8 times 3.0 different NC
47.5
45.0 - each measured - Number of fibres 2.8 samples
42.5
3 times measured: 2.6
found (as
40.0 2.4
37.5 >500’000 fibres 2.2
expected)
35.0
32.5
(= 30s with 400 frames/s) 2.0
Fibre Length:
30.0 or ≈ 70’000 fibres 1.8
27.5 (number of pixels) 1.6
25.0
1 2 3 4 (= 60s with 25 frames/s)
1.4
22.5
20.0 1.2
17.5
1.0
15.0
0.8
12.5
10.0 0.6
7.5
0.4
5.0
0.2
2.5
0.0 0.0
2 4 6 8 10 20 40 60 80 100 200 400 600 800 1000 2000 4000 6000
Faserlänge / µm
2012 NC Symp Spiez _ Pres Vogelsanger et al 1 _ Standards for NC Testing.ppt Vob © Nitrochemie 2012 15
New Standards for NC Testing – STANAG 4178 Ed. 2 / MIL-DTL-244 B/ECP / C
100
Cumulative Fibre Length Ll [%]
90
NC 01 I 196-10
80
Cut 1 _ 1 h
70 Cut 1_ 2 h
Cut 1_ 3 h
60 Cut 1 _ 3.7 h
50 Cut 2 _ 1h
Cut 2_2h
40 Progress of the refining Cut 2_3h
process can be tracked Cut 2 _ 3.7 h
30 almost in real-time Cut 3 _ 1h
20 Cut 3 _ 2 h
Cut 3 _ 2.8 h
10 Finished Lot
0
0 500 1000 1500 2000 2500 3000
Fibre Length [µm]
2012 NC Symp Spiez _ Pres Vogelsanger et al 1 _ Standards for NC Testing.ppt Vob © Nitrochemie 2012 16
New Standards for NC Testing – STANAG 4178 Ed. 2 / MIL-DTL-244 B/ECP / C
0
0 100 200 300 400 500 600 700 800
Fiber Length (µm)
2012 NC Symp Spiez _ Pres Vogelsanger et al 1 _ Standards for NC Testing.ppt Vob © Nitrochemie 2012 17
New Standards for NC Testing – STANAG 4178 Ed. 2 / MIL-DTL-244 B/ECP / C
General:
Many NC tests are still "old-fashioned" wet-chemistry methods
(time-consuming, difficult to automatise, yield little information)
No test for characterisation of NC processability available
Nitrogen Content of NC (Mean Value):
Existing test methods are complex and error-prone
Distribution of Nitrogen Content of NC:
No method for direct determination available
Is determined indirectly via solubility of NC in solvents
Polymeric Properties:
GPC method is not (yet) reproducible enough for routine testing
Falling sphere viscosity method is not suitable for low-viscosity NC
Fibre Quality – Agglomerate Content:
Actual method is not suitable for low agglomerate contents
2012 NC Symp Spiez _ Pres Vogelsanger et al 1 _ Standards for NC Testing.ppt Vob © Nitrochemie 2012 18
New Standards for NC Testing – STANAG 4178 Ed. 2 / MIL-DTL-244 B/ECP / C
All existing test methods for average N-content are complex + error-prone
Ferrous Ion Titration (FS/FAS) is reference method, but:
Many labs have reported problems with this method
Performance / results of FS/FAS depend strongly on
several experimental parameters → method is not robust
Not tolerable (and difficult to recognise) systematic
deviations may appear together with excellent precision
Exactly following the operating procedure as described in the
standards (MIL/ STANAG) does not guarantee correct results !
For example, STANAG 4178 Ed.2 / MIL-DTL-244B/ECP:
Allows to use from 50 mL to 125 mL of sulphuric acid
Does not specify the temperature of the acid (as long as below 25°°C)
Specifies titrant temperature to not exceed 25°°C for >30 s and to not
exceed 35°°C for >10 s and to not exceed 40°°C at all
However, changes within this range already markedly alter the result !!!
2012 NC Symp Spiez _ Pres Vogelsanger et al 1 _ Standards for NC Testing.ppt Vob © Nitrochemie 2012 19
New Standards for NC Testing – STANAG 4178 Ed. 2 / MIL-DTL-244 B/ECP / C
for NC (bubbles
N = 12.79%
12.74 → strong sensitivity
75 mL H2SO4 0°°C on H2SO4 volume
12.72 N = 12.78%
12.71
and T as well as
n=2 on titration T) are
12.70 50 mL H2SO4 0°°C almost negligible for
max. titration T 20°°C
KNO3 calibration
12.68 N = 12.76%
standard !!!
50 mL H2SO4 0°°C
12.66 max. titration T 30°°C
Adding 22°°C warm
12.65 N = 12.71%
sulphuric acid to NC
12.64
50 mL H2SO4 22°°C → micro-bubbles of
n = 28 max. titration T 30°°C
12.62
NO → "loss of
N = 12.65%
nitrogen"
2012 NC Symp Spiez _ Pres Vogelsanger et al 1 _ Standards for NC Testing.ppt Vob © Nitrochemie 2012 20
New Standards for NC Testing – STANAG 4178 Ed. 2 / MIL-DTL-244 B/ECP / C
N-Content
N-Content < 9.5% > 13.0%
N-Content 10% – 12.8%
→ Insoluble in → Soluble in
both Acetone and → Soluble in both Acetone
and Ether-Alcohol Acetone
Ether-Alcohol but insoluble in
Ether-Alcohol
9 10 11 12 13 14
Nitrogen Content of NC [%]
2012 NC Symp Spiez _ Pres Vogelsanger et al 1 _ Standards for NC Testing.ppt Vob © Nitrochemie 2012 21
New Standards for NC Testing – STANAG 4178 Ed. 2 / MIL-DTL-244 B/ECP / C
Summary
2012 NC Symp Spiez _ Pres Vogelsanger et al 1 _ Standards for NC Testing.ppt Vob © Nitrochemie 2012 22
New Standards for NC Testing – STANAG 4178 Ed. 2 / MIL-DTL-244 B/ECP / C
Outlook
2012 NC Symp Spiez _ Pres Vogelsanger et al 1 _ Standards for NC Testing.ppt Vob © Nitrochemie 2012 24