RPP - Course Completion Exam
RPP - Course Completion Exam
1. Where would you place the barricades for an Ir-192 source of 8500 mCi ?
a. 79 feet
b. 79 meter
c. 79 cm
d. 7.9 KM
a. 1000 mR/month
b. 500µSV/ day
c. 100mR/ month
d. B and C above
a. Wastage
b. Radiation decay
c. Contamination
d. None of the above
5. How long will it take for a Co-60 source of 4440 GBq to be reduced to 10 Ci?
a. 20 Years
b. 21 Years
c. 19 years
d. 17 years
6. Dose rate at certain distance from an Ir-192 source of 20 Ci is 90mR/Hr. What would
be the dose rate if the distance is increased by a factor of 4?
a. 56.25 mR/Hr
SPECIALIZED OIL&GAS ENGINEERING CO.LTD Question Set#
RPP-Course Completion Exam RPP/15-04
b. 56.25 µSv/Hr
c. 5.625 µSv/hr
d. 0.5625 R/Hr
a. Steel
b. Tungsten
c. Lead
d. Depleted Uranium
9. What thickness of lead is required to reduce the dose rate from 20 Ci , Ir-192 source
from 520 µSv/Hr to 5 mR/Hr?(HVL=0.22”)?
a. 18.9 mm
b. 0.74 cm
c. 0.34 “
d. 0.74 mm
a. Survey meter
b. Ionization
c. Iodization
d. Pulsed X Ray
11. How far one should move to reduce the dose rate by a factor of 64?
12. If one receives 20 µSV in an exposure of 12 minutes, what is the dose rate during
exposure?
a. 100 mR/Hr
b. 10µSv/hr
c. 0.01 R/hr
d. None of the above
SPECIALIZED OIL&GAS ENGINEERING CO.LTD Question Set#
RPP-Course Completion Exam RPP/15-04
13. For a density of 2.0, an Ir-192 source of 64 Ci requires 1 minute and 20 seconds.
What would be the exposure time after 15 months for the same density?
a. 86 minutes
b. 40 minutes
c. 50 minutes
d. 60 minutes
14. If one radiographer takes 20 exposure a day and works for 5 days a week and 40
weeks continuously in one year , what would be the dose received in one exposure?
a. 5 mR
b. 50 mR
c. 5µSv
d. 50 µSv
15. If one radiographer receives 18 mSV in first year, 15 mSV in second year, how
much maximum dose he may take in 3rd year?
a. 2000 mR
b. 200 mR
c. 50 mSv
d. 5 mSv
17. Which of the below dosimetruy device produces a legal dose record
18. You were leaving from a site after radiography and both survey meter stopped
working. You have already completed the offered joints. What will be your
next course of action?
a. Return the source to pit room and proceed for film developing
b. Inform the RSO about survey meters
c. Maintain the controlled area barricades and wait till working survey meter arrives
SPECIALIZED OIL&GAS ENGINEERING CO.LTD Question Set#
RPP-Course Completion Exam RPP/15-04
19. Maximum radiation level at 1000 mm from a Ir-192 source is 450 µSv. What is the
transport index ?
a. 450
b. 45 mR
c. 45
d. 4.5
20. If a radiographer works 5 days a week and daily makes 10 exposures each of which
causes a dose of 12 µSV. If he works continuously for 12 weeks what would be the
dose absorbed by him ?
a. 7200 mSV
b. 7200 mR
c. 720µsV
d. 720 mR
21. A Person working with a Ir -192 source of 851 GBq. What thickness of Lead he
should use to establish a 16 µSv/Hr dose rate at a distance of 18 meter from the
source? HVL is 0.22 inches?
a. 0.95 inches
b. 1.1 inches
c. 1.3 inches
d. 1.1 cm
a. 0.005 mCi
b. 0.050 µ Ci
c. 5 nCi
d. 185 TBq
25. For an Ir-192 source with activity 45 Ci how many HVL of lead will bring radiation
intensity to 12 mR/Hr at 20 meter distance? (HVL= 4.8 mm)
a. 2.5
b. 3
c. 4
d. 5
26. After every exposure source return to the projector shall be verified by :
27. Who is responsible for checking projectors, wind outs and extensions before leaving
for job?
a. RPO/RSO
b. Assistant Radioghrapher
c. Operations Manager
d. Radiographer
29. Activity of an Ir-192 isotope in March 1st 2015 is 60 Ci. What would be the activity at
July 15?
a. 30 Ci
b. 18 Ci
c. 15 Ci
d. 10 C
30. A number representing the maximum dose rate at 1 meter distance is called :
a. Dose rate
b. Transport index
c. Index dose rate
SPECIALIZED OIL&GAS ENGINEERING CO.LTD Question Set#
RPP-Course Completion Exam RPP/15-04
d. Threshold rate
31. Where should be the control area barricades erected for an Ir-192 source 35 Ci ?
a. 180 meter
b. 250 feet
c. 530 feet
d. 300 meter
32. The design of permanent radictive storage facilities must be approved by:
a. ID-RPO
b. KCARE
c. RPU/EPD
d. Company RPO
a. 1 week
b. 2 week
c. 10 days
d. 2 days
35. What thickness of lead would be required to maintain a dose rate of 25µSv/Hr at 10
meter distance from a Ir-192 source with 85 Ci activity?( HVL = 4.8 mm or 0.19
inches)
a. 12.8 inches
b. 1.43 inches
c. 1.28 inches
d. 0.50 inches
36. Acceptable tolerance in EPD performance verification
is : a. ± 20%
b. +20%
c. -20%
d. Any of the above
SPECIALIZED OIL&GAS ENGINEERING CO.LTD Question Set#
RPP-Course Completion Exam RPP/15-04
a. 3.125 mR
b. 31.25 mR
c. 187.5 mR
d. 187.5 µSv
38. Which of the below information is mandatory on a survey meter calibration sticker?
a. Year of manufacture
b. Sales agent
c. Calibration date
d. Calibration procedure no.
39. What thickness of lead to be used to reduce the dose rate at a location by 1/8 th
of initial dose rate (HVL of lead is .19 inch for Ir-192)
a. 0.57 mm
b. 0.57cm
c. 15 mm
d. 6.3 cm
a. Radiographer
b. ID-RPO
c. RPU/EPD
d. Users RPO