0% found this document useful (0 votes)
70 views2 pages

Iso Jar SM

Uploaded by

Nairo Alvarez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
70 views2 pages

Iso Jar SM

Uploaded by

Nairo Alvarez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Procedure for Taking Cuttings Samples with OIL BASED

MUD In IsoJars® for Head Space Analysis


1. Identify when and where you will collect the sample
2. Cut a thin slice like a cake and place in the jar (approximately 2 cups)
3. Add 10 drops of the dilute bactericide, Benzalkonium Chloride, to the jar.
4. Screw the lid on as tight as possible.
5. Tape the lid to keep it tight and from vibrating loose during shipment. Tape in same direction (clockwise) that the lid is
screwed on.

Procedure for Taking Cuttings Samples with WATER BASED MUD


In IsoJars® for Head Space Analysis
1. Identify when and where you will collect the sample
2. Cut a thin slice like a cake and place in the jar (approximately 2 cups)
3. Add water to reach the line on the label.
4. Do not fill the jar with water as the headspace gap is needed to allow gas to desorb into the gap.
5. Add 10 drops of the dilute bactericide, Benzalkonium Chloride, to the jar.
6. Screw the lid on as tight as possible.
7. Tape the lid to keep it tight and from vibrating loose during shipment. Tape in same direction (clockwise) that the lid is
screwed on.

Procedure for Taking Cuttings only Samples In IsoJars®

1. Take cuttings from the shale shaker.


2. Place on sieve of correct size and dip in clean oil based mud. If using water based mud you may rinse with water
3. Put cuttings in jar (approximately 1 cup)
4. Only add water to reach the line on the label.
5. Do not fill the jar with water as the headspace gap is needed to allow gas to desorb into the gap.
6. Leave about a 1-inch gap between the water and top of the jar.
7. Add 10 drops of the dilute bactericide, Benzalkonium Chloride, to the jar.
8. Screw the lid on as tight as possible.
9. Tape the lid to keep it tight and from vibrating loose during shipment. Tape in same direction (clockwise) that the lid is
screwed on.

© 2019 Stratum Reservoir. All rights


reserved. Stratum products and services are subject to the Company’s standard terms and conditions, available on request or at isotechlabs.com. For more information contact an authorized Stratum representative. Unless noted otherwise, trademarks and service marks herein
are the property of Stratum and may be registered in the United States and/or other countries. Stratum products named herein may be protected by one or more U.S. and/or foreign patents. For more information, contact [email protected]. Specifications are subject to
change without notice. Stratum sells its products and services in accordance with the terms and conditions set forth in the applicable contract between Stratum and the client.

FO#702 Rev. 7
Recording Sample Information
1. Record sample identification information on the jar label
The following is an example of the label on the jar–complete the label with all information available.

Seal lid as tight as possible and tape clockwise to ensure


sample integrity

Leave 1" of head space between from the top of the jar to the
water. Do not fill above the Maximum Fill Level line.
Add 10 drops of bactericide
Cover cuttings with water
Approx. 1 cup of rinsed cuttings
Be sure to label the IsoJar with:
1. Well Name
2. Depth Top
3. Depth Bottom
4. Date
5. Time
Packaging Samples 6. Comment

1. After jars are tightly sealed and taped, place them upside down in the original shipping box. If any leaks
are detected, transfer the sample to a new IsoJar®.
2. Complete the log sheet included in each box. List the samples being shipped in the box by Well Name,
Depth (ft. or m.), Date, Time (24-hour scale), Company/Contact and Operator.
3. Thoroughly seal the box with tape.

Sample and Jar Storage


1. Jars are guaranteed for 1 year from the shipment date from Isotech Laboratories
2. Jars and samples should be stored between 60oF and 80o F
3. In situations where the product may not have been handled or stored properly, the customer is advised to evaluate the
product for conformity and suitability for use.

© 2019 Stratum Reservoir. All rights


reserved. Stratum products and services are subject to the Company’s standard terms and conditions, available on request or at isotechlabs.com. For more information contact an authorized Stratum representative. Unless noted otherwise, trademarks and service marks herein
are the property of Stratum and may be registered in the United States and/or other countries. Stratum products named herein may be protected by one or more U.S. and/or foreign patents. For more information, contact [email protected]. Specifications are subject to
change without notice. Stratum sells its products and services in accordance with the terms and conditions set forth in the applicable contract between Stratum and the client.

FO#702 Rev. 7

You might also like