Vehicle Tracker Command List
Vehicle Tracker Command List
Command SERVER#
Reply SERVER,0,62.171.165.156,18378,0
Set Server
Get GPRS
Command GPRSON#
Reply GPRSON:1(1=ON, 0=OFF)
Command GPRSON,X#
Note X=0/1: 1 turn on GPRS,0 turn off GPRS
default: 1
Example GPRSON,1#
Reply OK!
Command LOCKIP#
Reply Domain successfully locked!
If the server SMS sent, you should reply “Error: The platform addresses are locked
modify!”
Command for unlock domain name / IP
Command UNLOCKIP#
Reply Domain successfully unlocked!
Note: When the device is disconnected from the main server, it will connect to
backup server. When it fails to connect the backup server, the device will switch
back to the primary server.
Get APN
Command APN#
Set APN
Example APN,internet.vodafone.net#
Reply OK! for the newly-set APN to take effect, the device will reboot after 10s.
Note: In default, the APN self-adaption is ON, there is no need to set the APN.
SOS number
Command SOS#
Reply SOS1: SOS2: SOS3: SOS4: SOS5:
SOS number
Add SOS number SOS,A, phone number 1,phone number 2,phone number 3,phone number
4,phone number 5#
Add the second SOS SOS,A,,phone number2#
number
Add the third SOS SOS,A,,,phone number3#
number
Delete SOS number SOS,D,sequence number 1,sequence number 2,sequence number
3,sequence number 4,sequence number 5#
Example ( Add SOS SOS,A,13728753237,13728753238,13728753239#
Number)
Reply OK! SOS1:13728753237 SOS2:13728753238 SOS3:13728753239 SOS4:
SOS5:
Example (Delete SOS SOS,D,1#
Number)
Reply OK! SOS1: SOS2:13728753238 SOS3:13728753239 SOS4: SOS5:
SOS alarm
Command SOSALM#
Reply SOSALM:ON mode:2(0=only
GPRS,1=GPRS+SMS,2=GPRS+SMS+Call,3=GPRS+Call)
Turn on SOS alarm
Command SOSALM,A,M#
Note A=ON/OFF, default:ON;
M=0/1/2, way of alarming, 0: GPRS only, 1: SMS+GPRS, 2:
GPRS+SMS+phone call, 3, GPRS +CALL, default:2;
Example SOSALM,ON,1#
Reply OK!
Press the SOS button for 3S to trigger the SOS alarm. If the alarm way is GPRS+SMS+call, the
SOS alarm message is immediately uploaded to the platform. Later,the power-off alarm SMS is sent
to the set SOS number, and the set SOS phone number is dialed in sequence. If one of the SOS
numbers is answered, it will stop dialing. If there is no answer, the call will be repeated up to 3
times. The number of calls can be set.
Parameter status
Version
Command VERSION#
Reply [VERSION]NT36_GT06N_WAAD_V2.1.1_211108.2013
Parameters
Command PARAM#
Reply Device parameters
Example PARAM#
Reply GPS report on time interval:
IMEI:356153591305617; TIMER:10,10; SENDS:5; SOS:,,; Center
Number:; Sensorset:10,1,5,1; Defense time:10; TimeZone:E,8,0;
Command GPRSSET#
Reply GPRS:ON; Currently use APN:internet.vodafone.net,internet,internet;
SERVER,1,www.trackeg.com,18378,0;
URL:http://maps.google.com/maps?q=N22.577156,E113.916748;
Status
Command STATUS#
Reply Battery:3.89V,NORMAL; GPRS:Link Up; GSM Signal Level:Strong;
GPS:Successful positioning; SVS Used in fix:19(24); , GPS Signal
Level:32,36,41,31,33,33,22,39,26,30,0,0,0,0,0,0,0,0 ACC:OFF;
Defense:OFF;
Reset
Command RESET#
Reply The terminal will restart after 20sec!
Restore to factory
Command FACTORY#
Reply OK!
The terminal will restart after 60s!
Note: If you send the FACTORY# command, all parameters except domain name, APN,
locked domain name will restore to default.
Timezone/Heartbeat packet
Get Timezone
Command GMT#
Reply GMT:E,8,0 (AUTO)
Timezone
Command GMT,A,B,C#
Note A: E/W; E for East Time Zone, W for West Time Zone; Default: E
B: 0 to 12; time zone; default: 8
C: 0/15/30/45; half time zone; default: 0
Example GMT,E,8# = GMT,E,8,0#
Reply OK!
Command HBT#
Command HBT,T1,T2#
Position
Latitude and longitude
Command WHERE#
Reply Current position!
Lat:N30.234623,Lon:E31.497961,Course:234.68,Speed:0.00Km/h,DateTime:
2022-12-17 02:37:38
Location link
Address
Command URL#
Reply <11-15 14:13>http://maps.google.com/maps?q=N22.576740,E113.916530
Command TIMER#
Reply TIMER:10,10
Command TIMER,T1,T2#
Note T1 ranges 0/5~18000 seconds, upload interval when ACC ON, default
is 10;
T2 ranges 0/5~18000seconds, upload interval when ACC OFF, default is
10;
Example TIMER,60,60#
Reply OK!
Command DISTANCE#
Reply DISTANCE:300
Command DISTANCE,D#
Note D ranges 0/50~10000 meters, distance interval, default is 300;
Example DISTANCE,500#
Reply OK!
Get ACC status
Command ACCREP#
Reply ACCREP:ON
Command ACCREP,A#
Note A=ON/OFF,upload for ACC status change,default: ON
Example ACCREP,ON#
Reply OK!
Command CALL#
Reply CALL:3
Command CALL,A#
Note A=times of calling, range: 1-3, default: 3
Example CALL,1#
Reply OK!
Command POWERALM#
Reply POWERALM:ON,2,5,300
Turn on power cutoff alarm
Command POWERALM,A,M,T1,T2#
Note A=ON/OFF, default: ON;
M=0/1/2, way of alarming,
0: GPRS only, 1:
SMS+GPRS,
2 : GPRS+SMS+phone call, M=3 GPRS+CALL,
default: 2; T1=2~60 (second), default: 5;
T2=1~3600 (second), default: 300
Example POWERALM,ON,1,10,60#
Reply OK!
Triggering process
When the fuse of external power supply is blown (or the external power supply is depleted) or the
external power cable is cut off, the device will immediately send a power off alarm to the SOS
number and platform.
Command FENCE#
Reply FenceType:Circle, OFF, Latitude:0.000000, Longitude:0.000000,
radius:300m, in out:IN or OUT, alarm type:1
Or
Circular fence
Command FENCE,B,0,D,E,F,X,M#
Note B=ON/OFF, turn on/off fence alarm, default: off;
D=the latitude of the circle center; D=0, take current location as the center
E=the longitude of the circle center; E=0, take current location as the center
F=1~9999, the fence radius, unit:100 meters;
X=IN/OUT; IN: alarming when enter the fence, OUT: alarming when exit
the fence, blank means both alarming when enter or exit the fence, default:
blank.
Example FENCE,ON,0,N22.577124,E113.916786,8,,1#
Reply OK! FenceType:Circle, ON, Latitude:N22.577124,
Longitude:E113.916786,
radius:800m, in out:IN or OUT, alarm type:1.
Rectangle fence
Command FENCE,B,1,D,E,F,G,X,M#
Note B=ON/OFF, turn on/off fence alarm, default:off;
D=the latitude of the position 1;
E=the longitude of the position 1; F=the latitude of the position 2; G=the
longitude of the position 2;
X=IN/OUT; IN: alarming when enter the fence, OUT: alarming when exit
the
fence, blank means both alarming when enter or exit the fence, default:
blank.
Alarm message will be sent to the SOS numbers and platform if the
Alarm message will be sent to the SOS numbers and platform if the
Displacement alarm
Command MOVING#
Reply Moving Switch:OFF; Radius:300m; Alarm type:1
Command MOVING,A,R,M#
Note A=ON/OFF, default: OFF;
R=100~1000, moving radius, unit: meter, default: 300;
M=0~3, way of alarm. 0: GPRS only, 1: SMS+GPRS, 2:
GPRS+SMS+phone call, 3, GPRS+CALL, default: 1;
Example MOVING,ON,100,2#
Reply OK!
When the car is changing from ACC ON to ACC OFF, alarm will be triggered if the car moves
out of the displacement radius.
Attention! The vehicle is moved.<04-08 16:08>
http://maps.google.com/maps?q=N22.488430,E113.937729
Command DEFENSE#
Reply DEFENSE:10min
Command DEFENSE,A#
Note A:1~600minutes,time for alarming delay,default: 10minutes
Query current DEFENSE#
parameter
Example DEFENSE,5#
Reply Ok!
Note: In arming state, if the car’s ACC is OFF for 10 minutes, the device
will switch to arming.
Command BATALM#
Reply BATALM,ON,1
Command BATALM,A,M#
Note A=ON/OFF; Default: ON
M= alarm way, range 0~1; default M=1
Example BATALM,ON,0#
Reply OK!
Note: When the remaining battery capacity is less than 10%, the device will send low
Command EXBATALM#
Reply EXBATALM,ON,0,100,130,10
Command EXBATALM,A,M,N1,N2,T#
Note A=ON/OFF; Default: OFF
M = alarm way, range 0 ~ 1; 0 only GPRS, 1 SMS + GPRS;
default: M = 1;
N1=10-360; low voltage alarm threshold, unit: V default: 100
N2=10-360; contact alarm threshold, unit: V default: 130
T=1-300; detection time, unit: second, default value: 10 seconds;
Example EXBATALM,ON,0,100,130,10#
Reply OK!
Note: If the battery detected is lower than N1 for 10 seconds, external low battery
protection alarm will be triggered. If battery detected is higher than N2, the alarm will
be released.
Command EXBATCUT#
Reply EXBATCUT,ON,1,120,135,10
Turn on external low battery protection
Command EXBATCUT,A,M,N1,N2,T#
Note A=ON/OFF ON:Power IC turned off if external low battery
protection requirements obtained. OFF: neither cut power IC nor enter
flight mode default: ON
Note: If the battery detected is lower than N1 for 10 seconds, external low battery
protection alarm will be triggered. If battery detected is higher than N2, the alarm will
be released.
Command CENTER#
Reply CENTER: 15942703401
Or
CENTER:
Centre number
Or
OK
Center Number:
Get Power/petrol
Command RELAY,A#
Reply RELAY:0
Command RELAY,A#
Note A=0/1: 0: connect the power/petrol;
1: disconnect the power/petrol
default: 0
Example RELAY,0#
Reply Restore fuel supply: Success!
Or
Command RELAY,A#
Note A=0/1: 0: connect the power/petrol;
1: disconnect the power/petrol
default: 0
Example RELAY,1#
Reply Cut off the fuel supply: Success!
Or
Already in the state of fuel supply cut off, the command is not running!
Mileage
Command MILEAGE#
Reply MILEAGE:OFF, Total Mileage:0km,K:1000
Command MILEAGE,A,L#
Note A=ON/OFF; Default OFF
L = mileage initial value, mileage value, unit: km, range 0-999999km; when L is
0, it means that the mileage is cleared. The default is 0;
Example MILEAGE,ON,100#
Reply OK!
Note: The device will only calculate mileage when the car starts (ACC ON).
Get IMEI
Command IMEI#
Reply IMEI:359647091149455
Set IMEI