0% found this document useful (0 votes)
97 views5 pages

DS - Coriolis Flow Meter

This document is a datasheet for Coriolis flow meters to be used at the Nadua surface production facilities project in India. It includes 5 sheets that provide an index of sheets, revision record, notes, and specifications for two Coriolis flow meters. The meters will be used to measure crude oil flow, have stainless steel wetted parts, and explosion proof enclosures rated for the hazardous area classification at the site.

Uploaded by

Nawfel Arafath
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
97 views5 pages

DS - Coriolis Flow Meter

This document is a datasheet for Coriolis flow meters to be used at the Nadua surface production facilities project in India. It includes 5 sheets that provide an index of sheets, revision record, notes, and specifications for two Coriolis flow meters. The meters will be used to measure crude oil flow, have stainless steel wetted parts, and explosion proof enclosures rated for the hazardous area classification at the site.

Uploaded by

Nawfel Arafath
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

DATASHEET FOR CORIOLIS FLOW METER

Revision Index
CREATION OF SURFACE PRODUCTION FACILITIES (OCS)
Rev
AT NADUA Datasheet Number
Code

DATASHEET FOR CORIOLIS FLOW METER OIL-100-ND-I-DS-0803 A0 SHEET 02 OF 05

INDEX SHEET

SHEET No. TITLE


1 COVER SHEET
2 INDEX SHEET
3 REVISION SHEET
4 NOTES SHEET
5 DS-CORIOLIS FLOWMETER (FISCAL FLOW METER)
Revision Index
CREATION OF SURFACE PRODUCTION FACILITIES (OCS)
Rev
AT NADUA Datasheet Number
Code

DATASHEET FOR CORIOLIS FLOW METER OIL-100-ND-I-DS-0803 A0 SHEET 03 OF 05

REVISION RECORD SHEET

REV No. PURPOSE LIST OF PAGES OF UPDATED / MODIFIED SECTIONS, IF ANY


A0 ISSUED FOR REVIEW FIRST ISSUE
Revision Index
CREATION OF SURFACE PRODUCTION FACILITIES (OCS)
Rev
AT NADUA Datasheet Number
Code

DATASHEET FOR CORIOLIS FLOW METER OIL-100-ND-I-DS-0803 A0 Sheet No.: 04 of 05

Notes Sheet

1. Documentation required :- Calibration certificate,Material certificates to 3.1 as per EN10204, weather proof to IP65 certificate by ATEX or Equivalent body, Pressure test
procedure/Report, NDT procedure / Report, Operating and Maintenance Instructions & Spare Parts List.
2. Coriolis flow metershall be provided with 1 mm thick, 30mm x 75mm SS 316 tag plate, inscribed with tag number engraved or embossed
in 5mm high and 0.3mm deep bold characters and black paint filled. The tags shall be mounted on or adjacent to the associated
instrument and either fixed with stainless steel screws or attached with stainless steel wire.
3. Coriolis meters shall be designed to ISO 10790.
4. All stud bolt material shall be ASTM A 193 Gr. B7 / ASME B16.5 (Hot dip galvanized).
5. The Coriolis Meter shall be provided with a local LCD display with Engineering unit indication.
6. Instrument shall meet the Electromagnetic Interference requirements to EN50082-2 / IEC 60533.
7. All weldings and castings (if any) shall be 100% radiographed.
8. Any special cable between the sensor transmitter & receiver electronics to be provided by flowmeter vendor.
9. Transmitter shall be provided with dual cable entries. Unused cable entries shall be provided with explosion proof plugs of SS 316.
10. Coriolis meter shall be Ex"ia" in accordance with IEC 60079. In the event of Ex"ia" is not available or cannot be used then Ex"d" type of
protection shall be used and notified to the buyer for approval.
11. Mass flow meters shall be of Coriolis - two tube design.
12. Coriolis Mass Flow Meter shall be of in-line mounting design with flow direction clearly marked on the flow tube body to ensure
proper installation.
13. Flanged end connection and Flange face finish of the Coriolis Mass Flow Meter shall be as per ASME B 16.5.
14. Meter body shall be hydrostatically tested as per requirement specified in relevant clause of ASME F 423.
TITLE ITEM/TAG No. DATA SHEET No.
DATASHEET FOR CORIOLIS FLOW METER REFER BELOW OIL-100-ND-I-DS-0803
PROJECT DESCRIPTION PROJECT NO. SHEET REV
CREATION OF SURFACE PRODUCTION FACILITIES (OCS) AT NADUA KIP-17039 05 OF 05 A0
MPC CONTRACTOR CLIENT CONTRACT No. REQUISITION No. SPECIFICATION No.
TBA - -
CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION
OIL INDIA LIMITED A0 IMR 28-Nov-18 MV 28-Nov-18 MSR/VSR 28-Nov-18 Issued for Review
CLIENT DOC .No
-
ORIGINATOR ORIG. DATE
IMR 13-Sep-18
UNITS:- Pressure bar g kg/cm 2 g kPa g psig Flow : Gas MMSCFD Sm 3/hr kg/hr
0 0
Temp C F Liquid m3/hr kg/hr KLPD lit / hr
1 TAG NO. 20-FT-2008 20-FT-2009

2 QUANTITY ONE ONE

3 LINE No. 3"-PL-20-2402-AC01 3"-PL-20-2403-AC01

4 P & ID No. 17039-ND-P-DW-0219-01 17039-ND-P-DW-0219-01


GENERAL 5 LINE SIZE/SCH 3" / STD 3" / STD

6 LINE INSULATION NO NO

7 SERVICE CRUDE OIL CRUDE OIL

8 AREA CLASSIFICATION ZONE-2, Gr IIA & IIB, T3 ZONE-2, Gr IIA & IIB, T3

9 ENCLOSURE IP 65, Ex 'ia' IP 65, Ex 'ia'

10 SIZE RATING 3" 150#RF 3" 150#RF

11 END CONNECTION & FACE FINISH FLANGED 125 - 250 AARH FLANGED 125 - 250 AARH

12 END CONNECTION FLANGE MATERIAL CARBON STEEL A216 WCB CARBON STEEL A216 WCB
METER TYPE &
13 SENSOR SPOOL PIECE MATERIAL CARBON STEEL A216 WCB CARBON STEEL A216 WCB
MATERIAL
14 SENSOR MATERIAL SS 316 SS 316

15 OTHER WETTED PARTS MATERIAL SS 316 SS 316

16 ENCLOSURE MATERIAL SS 316 SS 316

17 POWER SUPPLY 230 VAC / 60 Hz 230 VAC / 60 Hz


4-20mA, DC, SMART type with HART
TRANSMITTER 18 OUTPUT Protocol
4-20mA, DC, SMART type with HART Protocol
SUPPLY & SIGNAL ZONE-2, Gr IIA & IIB, T3 ZONE-2, Gr IIA & IIB, T3
19 AREA CLASSIFICATION
20 ENCLOSURE MATERIAL SS 316 SS 316

21 MEASURING RANGE (CALIBRATED FLOW) * *

22 ADJUSTABLE RANGE - -

23 ACCURACY +/- 0.1 % +/- 0.1 %

24 SENSITIVITY - -
FLOW METER
25 REPEATABILITY RANGEABILITY - 100:1 - 100:1
DATA
AUTOMATIC TEMPERATURE
AUTOMATIC TEMPERATURE COMPENSATION
26 EFFECT OF TEMPERATURE COMPENSATION

27 MINIMUM DETECTION LIMIT - -

28 CABLE ENTRY CONNECTION ISO M20 (METRIC) ISO M20 (METRIC)

29 FLUID AND STATE CRUDE OIL / LIQUID CRUDE OIL / LIQUID

30 TEMPERATURE: OPERATING / DESIGN 55 90 (Hold) 55 90 (Hold)

31 PRESSURE: OPERATING / DESIGN 10 15 (Hold) 10 15 (Hold)

32 ALLOWABLE PRESS. DROP ACROSS METER 0.3 (Hold) 0.3 (Hold)

33 OPERATING VISCOSITY (Cp) 3.8 (Hold) 3.8 (Hold)


SERVICE 3 @ OT °C
34 DENSITY kg/m MOLECULAR WEIGHT 900 - 900 -
CONDITIONS
35 FLOW (MIN / NORMAL / MAX) m3/day - - 600 (Hold) - - 600 (Hold)

36 WATER CONTENT: (m3/day) MAXIMUM 3.1 (Hold) 3.1 (Hold)

37 NORMAL - -

38 MINIMUM - -

39 SALINITY - -

40 LOCAL DISPLAY YES YES

41 MODEL NO. FOR SENSOR * *


OTHERS
42 MODEL NO. FOR TRANSMITTTER * *

43 MANUFACTURER * *
NOTES:-

REFER SHEET 4