CDC6 - 185 Contactor Main

The document provides specifications for CDC6 AC contactors including: - Rated currents from 9A to 630A - Rated voltages of 220/240V, 380/400V, 415/440V, 660/690V - 3 poles - Rated operational power from 2.2kW to 335kW depending on the model - Electrical durability of 100,000 operations for most models - Coil voltages include 24V, 36V, 48V, 110V, 127V, 220V, 230V, 240V, 380V, 400V, 415V, 440V.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
84 views16 pages

CDC6 - 185 Contactor Main

The document provides specifications for CDC6 AC contactors including: - Rated currents from 9A to 630A - Rated voltages of 220/240V, 380/400V, 415/440V, 660/690V - 3 poles - Rated operational power from 2.2kW to 335kW depending on the model - Electrical durability of 100,000 operations for most models - Coil voltages include 24V, 36V, 48V, 110V, 127V, 220V, 230V, 240V, 380V, 400V, 415V, 440V.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 16

CDC6 AC Contactor

Standard: IEC60947-1,IEC 60947-4-1

Order Information

Product Name Rated Current Auxiliary Contact Coil Voltage Coil Frequency
CDC6 09 11 M

09:9A 11:1NO+1NC B:24V Default:50HZ


… 00:0NO+0NC … 7:50/60HZ
630:630A X:440V

AC-3,380/400V Instant Auxiliary Contact


Rated Current Rated Power Reference
(A) (KW)

9 4 1 1 CDC6 09 11 □□
12 5.5 1 1 CDC6 12 11 □□
18 7.5 1 1 CDC6 18 11 □□
25 11 1 1 CDC6 25 11 □□
32 15 1 1 CDC6 32 11 □□
40 18.5 1 1 CDC6 40 11 □□
Protection
Motor Control &

50 22 1 1 CDC6 50 11 □□
65 30 1 1 CDC6 65 11 □□
80 37 1 1 CDC6 80 11 □□
95 45 1 1 CDC6 95 11 □□
115 55 - - CDC6 115 00 □□
150 75 - - CDC6 150 00 □□
185 90 - - CDC6 185 00 □□
225 110 - - CDC6 225 00 □□
265 132 - - CDC6 265 00 □□
330 160 - - CDC6 330 00 □□
400 200 - - CDC6 400 00 □□
500 250 - - CDC6 500 00 □□
630 335 - - CDC6 630 00 □□

Note: “□□” means coil voltage code.

Code Table of Coil Voltage


Coil Voltage (V) 24 36 48 110 127 220 230 240 380 400 415 440
50HZ B C E F S M N U Q V L X

50/60HZ B7 - E7 F7 - M7 N7 U7 Q7 V7 - -

Note: 115-630AF refer to the actual situation.

121
CDC6 AC Contactor
Standard: IEC60947-1,IEC 60947-4-1

Order Information
Product Name Rated Current Directional Conatctor Coil Voltage Coil Frequency
CDC6 09 N M

09:9A N B:24V Default: 50HZ


… … 7:50/60HZ
630:630A X:440V

AC-3,380/400V Instant Auxiliary Contact


Rated Current Rated Power Reference
(A) (KW)

9 4 1 1 CDC6 09N □□
12 5.5 1 1 CDC6 12N □□
18 7.5 1 1 CDC6 18N □□
25 11 1 1 CDC6 25N □□
32 15 1 1 CDC6 32N □□
40 18.5 1 1 CDC6 40N □□
50 22 1 1 CDC6 50N □□

Protection
Motor Control &
65 30 1 1 CDC6 65N □□
80 37 1 1 CDC6 80N □□
95 45 1 1 CDC6 95N □□
115 55 - - CDC6 115N □□
150 75 - - CDC6 150N □□
185 90 - - CDC6 185N □□
225 110 - - CDC6 225N □□
265 132 - - CDC6 265N □□
330 160 - - CDC6 330N □□
400 200 - - CDC6 400N □□
500 250 - - CDC6 500N □□
630 335 - - CDC6 630N □□

Note: “□□” means coil voltage code.

Code Table of Coil Voltage


Coil Voltage (V) 24 36 48 110 127 220 230 240 380 400 415 440
50HZ B C E F S M N U Q V L X

50/60HZ B7 - E7 F7 - M7 N7 U7 Q7 V7 - -

Note: 115-630AF refer to the actual situation.

122
CDC6 AC Contactor
Standard: IEC60947-1,IEC 60947-4-1

Main Technical Parameter

Model CDC6-09 CDC6-12 CDC6-18 CDC6-25 CDC6-32 CDC6-40 CDC6-50 CDC6-65 CDC6-80 CDC6-95

Main circuit Characteristics


Rated Operational le, AC-3 9A 12 A 18 A 25 A 32 A 40 A 50 A 65 A 80 A 95 A
Current le, AC-1 20 A 20 A 32 A 40 A 50 A 60 A 80 A 80 A 125 A 125 A
Rated Isolation
Voltage (Ui) 690V

Rated Operational
690V
Voltage (Ue)
Number of Pole 3

Rated Operational 220/240V 2.2kW 3 kW 4 kW 5.5kW 7.5kW 11 kW 15 kW 18.5kW 22 kW 25 kW


Power 380/400V 4 kW 5.5kW 7.5kW 11 kW 15 kW 18.5kW 22 kW 30 kW 37 kW 45 kW
ClassAC-3 415/440V 4 kW 5.5kW 9 kW 11 kW 15 kW 22 kW 25 kW 37 kW 45 kW 45 kW
660/690V 5.5kW 7.5kW 10 kW 15 kW 18.5kW 30 kW 33 kW 37 kW 45 kW 45 kW
Electric durabilities
(10 thousand times) 100 100 100 100 80 80 80 80 60 60
AC-3
Protection
Motor Control &

Operating Rate 1200 1200 1200 1200 600 600 600 600 600 600
(time/h)
Mechanical
(10 thousand times) 1000 1000 1000 1000 800 800 800 800 800 800
Durabilities

Coil
Rated Control Circuit 50Hz 24V,36V,48V,110V,127V,220V,380V,400V,415V,440V
Voltage (Us) 50/60Hz 24V,36V,48V,110V,220V,230V,240V,380V,400V
Allowable Control Operation 85%~110% Us
Circuit Voltage (Us) Drop-out 20%~75% Us
Inrush VA 70 110 200
Coil Power Sealed VA 8 11 20
Heat dissipation W 1.8~2.7 3~4 6~10

Terminal Wiring Ability


Flexible Wire 1 pc (Section of Connecting 1~4 1~4 1.5~6 1.5~10 2.5~10 2.5~25 2.5~25 2.5~25 4~50 4~50
Conduction mm2)
Without Terminal
2 pcs (Section of Connecting
Block Conduction mm2) 1~4 1~4 1.5~6 1.5~6 2.5~10 2.5~16 2.5~16 2.5~16 4~25 4~25

Flexible Wire 1 pc (Section of Connecting


Conduction mm2)
1~4 1~4 1~6 1~6 1~10 2.5~25 2.5~25 2.5~25 4~50 4~50
With Terminal
2 pcs (Section of Connecting
Block Conduction mm2) 1~2.5 1~2.5 1~4 1~4 1.5~6 2.5~10 2.5~10 2.5~10 4~16 4~16

Fixed Wire 1 pc (Section of Connecting


1~4 1~4 1.5~6 1.5~6 1.5~10 2.5~25 2.5~25 2.5~25 4~50 4~50
Conduction mm2)
Without Terminal
2 pcs (Section of Connecting
Block 1~4 1~4 1.5~6 1.5~6 2.5~10 2.5~16 2.5~16 2.5~16 4~25 4~25
Conduction mm2)

Auxiliary Contact
Rated Thermal A 10
Current (Ith)
Rated Operational AC V 400
Voltage (Ue) DC V 230
Rated Control AC-15 VA 360
Capacity DC-13 W 33

123
CDC6 AC Contactor
Standard: IEC60947-1,IEC 60947-4-1

Contactor Type CDC6-115 CDC6-150 CDC6-185 CDC6-225 CDC6-265 CDC6-330 CDC6-400 CDC6-500 CDC6-630

Main circuit Characteristics


le, AC-3
Rated Operational 115 A 150 A 185 A 225 A 265 A 330 A 400 A 500 A 630 A
Current le, AC-1 200 A 200 A 275 A 275 A 315 A 380 A 450 A 630 A 800 A
Rated Isolation
1000V
Voltage (Ui)
Rated Operational
Voltage (Ue)
Number of Pole

Rated Operational 220/240V 30 kW 40 kW 55 kW 63 kW 75 kW 100kW 110kW 147kW 200kW


Power 380/400V 55 kW 75 kW 90kW 110kW 132kW 160kW 200kW 250kW 335kW
ClassAC-3 415/440V 59 kW 80 kW 100kW 110kW 140kW 180kW 220kW 280kW 375kW
660/690V 80 kW 100kW 110kW 129kW 160kW 220kW 280kW 335kW 450kW
Electric durabilities
(10 thousand times) 120 120 100 100 80 80 80 80 80
AC-3

Protection
Motor Control &
Operating Rate 600 600 600 600 600 600 300 300 300
(time/h)
Mechanical
(10 thousand times) 1000 1000 600 600 600 600 600 600 600
Durabilities

Coil
Rated Control Circuit 50Hz 110V,127V,220V,230V,240V,380V,400V,440V
Voltage (Us) 50/60Hz 110V,220V,380V (115-225AF)
Allowable Control Operation 85%~110% Us
Circuit Voltage (Us) Drop-out 20%~75% Us
Inrush VA 550 800 1200 1200 1250 1650
Coil Power Sealed VA 45 55 13 20 24 22
Heat dissipation W 16 24 12 14 18 20

Terminal Wiring Ability


1 pc (Section of
Connecting 95 120 150 185 240 240 - - -
Fixed Wire Conduction mm2)
Without Terminal
2 pcs (Section of
Block
Connecting - - - - - - 150 240 -
Conduction mm2)

Copper Bar 2 pcs (Size mm2) 20*3 25*3 25*3 32*4 32*4 30*5 30*5 40*5 60*5

Auxiliary Contact
Rated Thermal A 10
Current (Ith)
Rated Operational AC V 400
Voltage (Ue) DC V 230
Rated Control AC-15 VA 360
Capacity DC-13 W 33

124
CDC6 AC Contactor
Standard: IEC60947-1,IEC 60947-4-1

Directional Contactor

Directional Contactor Rated Capacity (kW) Rated Current (A) Rated Thermal
AC-3 AC-3 Current (A)
(Horizontal Installation)
400V 690V 400V 690V AC-1
CDC6-09N 4 5.5 9 6.6 20
CDC6-12N 5.5 7.5 12 8.9 20
CDC6-18N 7.5 10 18 12 32
CDC6-25N 11 15 25 18 40
Protection
Motor Control &

CDC6-32N 15 18.5 32 21 50
CDC6-40N 18.5 30 40 34 60
CDC6-50N 22 33 50 39 80
CDC6-65N 30 37 65 42 80
CDC6-80N 37 45 80 49 125
CDC6-95N 45 45 95 55 125
CDC6-115N 55 80 115 86 200
CDC6-150N 75 100 150 108 200
CDC6-185N 90 110 185 118 275
CDC6-225N 110 129 225 137 275
CDC6-265N 132 160 265 170 315
CDC6-330N 160 220 330 235 380
CDC6-400N 200 280 400 303 450
CDC6-500N 250 335 500 353 630
CDC6-630N 335 450 630 462 800

125
CDC6 AC Contactor
Standard: IEC60947-1,IEC 60947-4-1

Option for Star Delta Starter

Contactor (CDC6-09~95)

Max. Starting Frequency, 30 time/h; Max. Starting Time,30s


Motor Contactor Contactor Contactor Thermal Overload Relay
Class AC-3 50Hz 3-Phase Electromotor Straight Connection Delta Connection Star Connection
Delta Connection KM2 KM3 KM1(3)
P (KW) In (A) IrD (A) Type Type Type Type Setting Range (A)
1.5 3.5 2 CDC6-09 CDC6-09 CDC6-09 CDR6-18 1.8~2.5

Protection
Motor Control &
2.2 5 3 CDC6-09 CDC6-09 CDC6-09 CDR6-18 2.5~3.6
3 6.6 4 CDC6-09 CDC6-09 CDC6-09 CDR6-18 3.5~4.8
4 8.5 5 CDC6-09 CDC6-09 CDC6-09 CDR6-18 4.5~6.3
5.5 11.5 6 CDC6-09 CDC6-09 CDC6-09 CDR6-18 5~7
7.5 15.5 9 CDC6-12 CDC6-12 CDC6-09 CDR6-18 9~12
9 18.5 11 CDC6-18 CDC6-18 CDC6-12 CDR6-18 11~15
11 22 13 CDC6-18 CDC6-18 CDC6-12 CDR6-18 11~15
15 30 16 CDC6-25 CDC6-25 CDC6-18 CDR6-32 14~18
18.5 37 22 CDC6-25 CDC6-25 CDC6-18 CDR6-32 18~25
22 44 26 CDC6-32 CDC6-32 CDC6-25 CDR6-32 23~32
30 60 35 CDC6-40 CDC6-40 CDC6-32 CDR6-95 30~40
37 72 40 CDC6-50 CDC6-50 CDC6-40 CDR6-95 37~50
45 85 47 CDC6-65 CDC6-65 CDC6-50 CDR6-95 37~50
55 105 58 CDC6-80 CDC6-80 CDC6-65 CDR6-95 55~70
75 138 78 CDC6-95 CDC6-95 CDC6-80 CDR6-95 63~80

126
CDC6 AC Contactor
Standard: IEC60947-1,IEC 60947-4-1

Option for Star-Delta Starter

Environmental Requirements
Ambient Temperature:
-5°C~+40°C
Altitude: ≤2000m
Pollution Level: III
No obvious shaking and shock
vibration

Wiring Diagram for Star-Delta Starter

KM2
U2 U1 2 1 L1
V2 V1 4 3 L2
W2 W1 6 5 L3

KM3
Protection
Motor Control &

2 1 2 1
4 3 4 3
6 5 6 KM1 5

U2 U1 2 2 1
(1)

V2 V1 4 4 3
W2 W1 6 6 5
KM3/5
KM3/1

Remote Control

14 13 22 21 96 95
KM2
KM1

KM1

KM2
KM3

A2 A1 22 21 56 55 14 13 14 13
KM2

A2 A1
KM3

KM1

A2 A1 22 21 67 68

127
CDC6 AC Contactor
Standard: IEC60947-1,IEC 60947-4-1

Accessories
CDC6-9~95A Contactor Accessory

FR6 Mechanical Interlock Module

FD6 Top of Auxiliary Contact

FC6 Side Auxiliary Contact


FD6 Top of Auxiliary Contact

Protection
Motor Control &
CDR6 Thermal Overload Relay

FT6 Air Delayed Head

2 poles: FD6-11, FD6-20, FD6-02


Top of Auxiliary Contact
4 poles: FD6-22, FD6-13, FD6-31, FD6-40, FD6-04

Side Auxiliary Contact 2 poles: FC6-11, FC6-20, FC6-02

Making time-delay: FT6-20, FT6-22, FT6-24


Air Delayed Head
Breaking time-delay: FT6-30, FT6-32, FT6-34

FR6-32 Adaptive to Product of 9-32A, Horizontal Installation


Mechanical Interlocking module
FR6-95 Adaptive to Product of 40-95A, Horizontal Installation

X6 Coil Not applicable

Main Contact Not applicable

CDR6-18 CDR6-32 CDR6-95


0.10-0.15A 6.3-9A 30-40A
Thermal Overload Relay 0.12-0.18A 9-12A 37-50A
… … …
14-18A 23-32A 80-95A

128
CDC6 AC Contactor
Standard: IEC60947-1,IEC 60947-4-1

CDC6-115~630A Contactor Accessory

X6 Coil

FD6 Top of Auxiliary Contact

FD6 Top of Auxiliary Contact

FT6 Air Delayed Head


(Making time-delay)

FT6 Air Delayed Head


(Breaking time-delay)
Protection
Motor Control &

2 poles: FD6-11, FD6-20, FD6-02


Top of Auxiliary Contact
4 poles: FD6-22, FD6-13, FD6-31, FD6-40, FD6-04

Side Auxiliary Contact No Side Auxiliary Contact

Making time-delay: FT6-20, FT6-22, FT6-24


Air Delayed Head
Breaking time-delay: FT6-30, FT6-32, FT6-34

Mechanical Interlocking module Horizontal Installation and Vertical Installation

Spare parts, X6-115-630 (Voltage AC:230V,


X6 Coil
400V for Option)

Main Contact Spare parts, MC6-115~630

Available to adopt JRS2 Series of Thermal


Thermal Overload Relay
Overload Relay

129
CDC6 AC Contactor
Standard: IEC60947-1,IEC 60947-4-1

Auxiliary Contact
Installation Composition
Pole Contact Point Layout Reference
Position NO NC
0 2 FD6 02
51 61 53 61 53 63
2
1 1 FD6 11
52 62 54 62 54 64
2 0 2NC 1NO1NC 2NO FD6 20
Top
4 0 4 51 61 71 81 53 61 71 81 53 61 71 83
FD6 04
1 3 FD6 13
52 62 72 82 54 62 72 82 54 62 72 84
2 2 4NC 1NO3NC 2NO2NC FD6 22
53 61 73 83 53 63 73 83
3 1 FD6 31
4 0 FD6 40
54 62 74 84 54 64 74 84

3NO1NC 4NO

0 2 51 61 53 61 53 63
FC6 02
Side 2 1 1 FC6 11
52 62 54 62 54 64

2 0 2NC 1NO1NC 2NO FC6 20

FT6 Air Delayed Contact


Installation Reference
Delay Type Wiring Diagram Delay Range

Protection
Motor Control &
Position
0.1-3s FT6 20
Making A1 57 65

time-delay 0.1-30s FT6 22


10-180s FT6 24
Top A1 57 65 0.1-3s FT6 30
Breaking
time-delay 0.1-30s FT6 32
A2 53 65 10-180s FT6 34

130
CDC6 AC Contactor
Standard: IEC60947-1,IEC 60947-4-1

Mechanical Interlock Module

Horizontal Installation
Interlock Method Contact Type Reference
Mechanical Interlock CDC6-9~32 FR6 32 H
Electricity Interlock CDC6-40~95 FR6 95 H
CDC6-115~150 FR6 FF H
CDC6-185~225 FR6 GG H
Interlock
CDC6-265~330 FR6 HH H
without Electricity
CDC6-400~500 FR6 KK H
CDC6-630 FR6 LL H

Vertical Installation (Mechanical without Electricity)


Contact Type
Interlock Device Reference
Bottom Top
CDC6-115 CDC6-115 FR6 FF V
or CDC6-150 FR6 FF V
CDC6-150 CDC6-185 FR6 FG V
CDC6-225 FR6 FG V
Protection
Motor Control &

CDC6-265 FR6 FH V
CDC6-330 FR6 FH V
CDC6-400 FR6 FH V
CDC6-500 FR6 FH V
CDC6-630 FR6 FL V
CDC6-185 CDC6-185 FR6 GG V
or CDC6-225 FR6 GG V
CDC6-225 CDC6-265 FR6 GK V
CDC6-330 FR6 GK V
CDC6-400 FR6 GK V
CDC6-500 FR6 GK V
CDC6-630 FR6 GL V
CDC6-265 CDC6-265 FR6 HK V
or CDC6-330 FR6 HK V
CDC6-330 CDC6-400 FR6 HK V
CDC6-500 FR6 HK V
CDC6-630 FR6 HL V
CDC6-400 CDC6-400 FR6 HK V
CDC6-500 FR6 HK V
CDC6-630 FR6 HL V
CDC6-500 CDC6-500 FR6 HK V
CDC6-630 FR6 HL V
CDC6-630 CDC6-630 FR6 LL V

Note: Vertical installation adopts mechanical Interlock Device equipped


with the interlock without electricity

131
CDC6 AC Contactor
Standard: IEC60947-1,IEC 60947-4-1

X6 Coil

Adaptive Contactor Coil Voltage Reference

115A-150A 220V X6 150 M


380V X6 150 Q
185A-225A 220V X6 225 M
380V X6 225 Q
265A-330A 220V X6 330 M
380V X6 330 Q
400A 220V X6 400 M
380V X6 400 Q
500A 220V X6 500 M
380V X6 500 Q
630A 220V X6 630 M
380V X6 630 Q

Protection
Motor Control &
MC6 Main Contact

Number of Pole Contactor Current Specification Reference


115A MC6 115
150A MC6 150
185A MC6 185
225A MC6 225
3 265A MC6 265
330A MC6 330
400A MC6 400
500A MC6 500
630A MC6 630

132
CDC6 AC Contactor
Standard: IEC60947-1,IEC 60947-4-1

Overall Dimension of Installation


CDC6-9~32

4.5

35mm Rail
Amax

b
Bmax Cmax
B1max C1max
B2max C2max a

CDC6 9/12 18 25/32


A 74.5 74.5 80
B (without accessory) 45.5 45.5 56.5
B1 (with a FC6) 58 58 69
B2 (with two FC6) 71 71 82
C (without accessory) 84 89 99.5
Protection
Motor Control &

C1 (with FD6) 116 122 132


C2 (with FT6) 141 145 156
a 35 35 40
b 50/60 50/60 50/70

CDC6-9~32N

Fmax d
c
F1max
F2max

CDC6- 9N/12N 18N 25N/32N

F (without accessory) 108 108 132

F1 (with a FC6) 119 119 143

F2 (with two FC6) 131 131 155

c 60 60 71.5

d 25 25 31.5

133
CDC6 AC Contactor
Standard: IEC60947-1,IEC 60947-4-1

Overall Dimension of Installation

CDC6-40~95
B2max C2max
B1max C1max b
Bmax Cmax

75mm Rail
35mm Rail
a

Amax d

CDC6 40/50/65 80/95


A 127 127
B (without accessory) 75 85
B1 (with a FC6) 89 99
B2 (with two FC6) 102 112
C (without accessory) 118.5 127.5
C1 (with FD6) 150 160

Protection
Motor Control &
C2 (with FT6) 175 185
a 105 105
b 59 67
c 105 105
d 40 40
Φ1 5.5 5.5
Φ2 6.5 6.5

CDC6-40~95N
e

Fmax f
F1max h
F2max

CDC6 40N/50N/65N 80N/95N


F (without accessory) 169 190
F1 (with a FC6) 182 203
F2 (with two FC6) 195 216
e 90 100.5
f 50 60.5
h 130 140

134
CDC6 AC Contactor
Standard: IEC60947-1,IEC 60947-4-1

Overall Dimension of Installation

CDC6-115-330

X1
11.5

S 6.5

Bmax
M
H
Ha

X1
P P L

Amax f Ga R Cmax

X1 X1
Type Amax Bmax Cmax P S φ f M H L Ga Ha
(200-550V) (600-1000V)

CDC6-115 167 163 172 37 20 M6 131 147 124 107 10 15 80 110~120


CDC6-150 167 171 172 40 20 M8 131 150 124 107 10 15 80 110~120
Protection
Motor Control &

CDC6-185 171 174 183 40 20 M8 131 154 127 113.5 10 15 80 110~120


CDC6-225 171 197 183 48 25 M10 131 172 127 113.5 10 15 80 110~120
CDC6-265 202 203 215 48 25 M10 147 178 147 141 10 15 96 110~120
CDC6-330 213 206 220 48 25 M10 147 181 158 145 10 15 96 110~120

Note:" f " reserved space to ensure draw-out coil can take out easily.

CDC6-400~500
S
8.5
X1

Bmax
13.5

M
H
Ha

X1

L
P P

Amax f Ga Cmax

X1 X1
Type Amax Bmax Cmax P S f M H L Ga Ha
(200-550V) (600-1000V)

CDC6-400 213 206 220 48 25 M10 146 181 158 145 15 20 80 170~180
CDC6-500 223 233 233 55 30 M10 150 208 172 146 15 20 80 170~180

Note:" f " reserved space to ensure draw-out coil can take out easily.

135
CDC6 AC Contactor
Standard: IEC60947-1,IEC 60947-4-1

Overall Dimension of Installation

CDC6-630

S
10.5 L

X1
15.5

Bmax
H

M
Ha
Ga

X1
P P
Cmax
Amax f

X1 X1
Type Amax Bmax Cmax P S f M H L Ga Ha
(200-550V) (600-1000V)

CDC6-630 309 304 256 80 40 M12 181 264 202 155 20 30 180 180~190

Protection
Motor Control &
Note:" f " reserved space to ensure draw-out coil can take out easily.

Wiring Diagram
CDC6-09~95 CDC6-09N~95N
(Horizontal Installation, Mechanical +Electrical Interlock)
L1

L2
L3

A1 1L1 3L2 5L3 13NO 21NC


13/NO

13/NO
21/NC

21/NC
3

3
5

5
1

1
A1

A1
A2

A2
22

22
14

14
6

6
2
4

2
4

A2 2T1 4T2 6T3 14NO 22NC


W
U
V

CDC6-115~630 CDC6-115N~630N
(Horizontal Installation, Mechanical Interlock)
L1

L2

L3

A1 1L1 3L2 5L3


3

3
5

5
1

1
A1

A1

A2 2T1 4T2 6T3


A2

A2
6

6
2

W
U

136

You might also like