0% found this document useful (0 votes)
105 views

5.3.1.2 Oil Change: Operating Manual 5.3.1 - 2

1. The document provides instructions for changing the oil in a gear unit. It should be done every 2 years for mineral oil or every 4 years for synthetic oil. 2. The procedure involves draining the used oil through vent and drain screws, cleaning the gear unit, refilling it with 4.7 liters of new oil of viscosity class VG 220, and properly disposing of the used oil. 3. Different types of oil can be used, but one should never mix mineral oil, synthetic oil, or grease, and all plug screws should be re-tightened after refilling.

Uploaded by

Vijay Bhure
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
105 views

5.3.1.2 Oil Change: Operating Manual 5.3.1 - 2

1. The document provides instructions for changing the oil in a gear unit. It should be done every 2 years for mineral oil or every 4 years for synthetic oil. 2. The procedure involves draining the used oil through vent and drain screws, cleaning the gear unit, refilling it with 4.7 liters of new oil of viscosity class VG 220, and properly disposing of the used oil. 3. Different types of oil can be used, but one should never mix mineral oil, synthetic oil, or grease, and all plug screws should be re-tightened after refilling.

Uploaded by

Vijay Bhure
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Operating Manual 5.3.

1 - 2

5.3.1.2 Oil Change


An oil change should be carried out at least every 2 years, in case of synthetic products every 4 years. When
changing the oil clean the gear unit thoroughly.

No. Procedure

1 Make sure the geared motor is standing still and recurred against re-activation.
2 Investigate the motor with respect to its posi-
tion of installation. The motors are installed
horizontally (position H3 or H4). Which of the oil level
screws are for draining or for filling depends
on the position. vent

drain

3 Place a container under the gear unit to collect the used oil. Open vent and drain screws and wait till
the oil is drained completely.
4 Clean the gear unit thoroughly from sediments and oil residues.
5 Close the oil discharge and loosen the corresponding plug screw through which the unit is to be filled.
6 Fill the gear unit with the intended amount of oil (4,7 l). Use an oil of viscosity class VG 220. Generally
(and also when initially filled by factory) a mineral oil is applied. Alternatively, synthetic oil or flux grease
can be used. The table below provides a selection of suitable lubricants.
Caution:
Never mix different lubricants – like mineral oils, synthetic oils or grease, neither
for use nor for removal!

7 Re-tighten all plug screws thoroughly.


8 Remove all evidences of oil and deposit the used oil according to any applicable environmental regula-
tions.