0% found this document useful (0 votes)
92 views

VFD Brochure 2022-04

This brochure provides information on NIETZ's variable speed drives and accessories product line. NIETZ is a leading manufacturer of industrial automation products established in 2005 in Shanghai, China. The brochure describes their commitment to quality, reliability and low prices. It then provides details on 13 specific variable speed drive models, including specifications, features, functions and environmental tolerances.

Uploaded by

ABMOHE
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
92 views

VFD Brochure 2022-04

This brochure provides information on NIETZ's variable speed drives and accessories product line. NIETZ is a leading manufacturer of industrial automation products established in 2005 in Shanghai, China. The brochure describes their commitment to quality, reliability and low prices. It then provides details on 13 specific variable speed drive models, including specifications, features, functions and environmental tolerances.

Uploaded by

ABMOHE
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 16

BROCHURE

Variable Speed Drives & Accessories


» WHO WE ARE
The products of NIETZ are Variable Frequency
NIETZ is one Leading Manufacturer of
Inverters, AC Servo System, Soft Starter, Planetary
industrial automation products, with more
than millions units sold worldwide, establi- Gearboxes and Complete Device,The products NIETZ
shed 2005 Shanghai, China. We are commi- are technological advanced products and it has quite
Innovation + tted to building long-lasting and successful wide product range and already used widely in various
business relations with our partners, has applications such as textile machine, air compressor,
Driving Tomorrow gained good reputation and deep influence. hoist, packing machine, printing machine, electronic
machine and other industries, which exported to over
We aim to provide the best quality, unma-
40 countries and regions such as Europe, South America,
tched reliability and low price in our services
Southeast Asia, Middle East and so on.
and our products. We aim to reduce your costs,
streamline manufacturing, to improve
productivity.
NIETZ always aims to be the professional driving
solution provider and your mutual-benefit partner. «

Receiption

CONTENTS
Factory View

Variable Speed Drives


02 NL1000

03 AT20

04 NZ2000

05 NZ8000

06 NZS

Production Workshop SMT Lines 07 PDS-7

08 WP9

09 APV

10 CV20

11 ESD / ESD2

12 AMD

13 AT10

Assembly Workshop Testing Lines

1
NL1000
Micro & Economic

ƒ Small Dimension, Low Cost


ƒ Terminals Uncovered, Easy to Use and Wiring
ƒ DIN-Rail Mounting and Wall Mounting
ƒ Support MODBUS via RS485
ƒ V/F Control; Buit-in PID Control
ƒ Frequency Range 0.1...999.9Hz

Item Specifications
220 VAC, 50/60Hz, 1 Phase Input and 3 Phase Output
220 VAC, 50/60Hz, 1 Phase Input and 1 Phase Output
Rated Voltage 220 VAC, 50/60Hz, 3 Phase Input and 3 Phase Output
Power Supply 380 VAC, 50/60Hz, 3 Phase Input and 3 Phase Output
220 VAC 170-240 VAC
Voltage Range
380 VAC 330-440 VAC
220 VAC 0-240 VAC
Voltage Range
Output 380 VAC 0-380 VAC
Frequency Range 0.10-999.9 Hz
Control Mode V/F Control, Space Vector Control
Operating status/Alarm definition/interactive guidance: eg,
Indication frequency setting, the output frequency/ current, DC bus voltage,
the temperature and so on.
Output Frequency Range 0.10-999.90 Hz
Digital Input 0.1 Hz
Frequency Setting Resolution
Analog Input 0.1% of Max. Output Frequency
Output Frequency Accuracy 0.1 Hz
Control Specification

V/F Control Setting V/F Curve to Satisfy Various Load Requirements


Auto Increase Auto raise Torque by Loading Condition
Torque Control
Manual Increase Enable to Set 0.1-20.0% of Raising Torque
One Multi-Fuction Output Terminal for Displaying of Running, Zero Speed,
Multi-Functional Output Terminal Counter, External Abnormity, Program Operation and Other Information and
UP / DOWN Fuction and Emergency Stop and Other Functions.
Four Multi-Fuction Input Terminals, Realizing Functions Including 15 Sections Speed
Multi-Functional Input Terminal Control, Program Running, 4 Section Acceleration / Deceleration Speed Switch,
Warnings.
Accel/Decel Time 0-999.9s Acceleration/Deceleration Time can be Set Individually
Analog input 0 to 10V, 0to 20mA can be Selected.
Digital Input Input Using the Setting Dial of the Operation Panel or RS485 or UP/DOWN.
Others Functions

Frequency Setting
Note AVI Terminals can be Used to Select an Analog Voltage Input (0-10V) and
Analog Current Input (4-20mA) through the Switch J2.
Multi-Speed 4 Multi-Fuction Input Terminals, 15 sections Speed can be Set
Automatic Voltage Regulation Automatic Voltage Regulation Function can be Selected
Counter Built-in 2 Group of Counters
Overload 150%, 60 s (Constant Torque)
Protection

Over Voltage Over Voltage Protection can be Selt.


Function

Under Voltage Under Voltage Protection can be Set.


Other Protections Output Short Circuit, Over Current and Parameter Lock and so on.
Ambient Temperature -10 to 40 C (Non-Condensing)
Ambient Humidity Max. 95% (No-Condensing)
Environment
Installation

Altitude Lower Than 1000m


Vibration Max. 0.5G
Cooling Mode Forced Air Cooling.
Protection Class IP20
Installation Mode Wall-Mounted or Standard 35mm Rail Mounting (Below 5.5kW)

2
AT20
General Purpose, Compact

ƒ Various Control Version, V/F, Sensorless


Remove keypad Vector and Cloosed Loop Vector Control
ƒ Built-in braking unit up to 450kW (optional)
ƒ Support MODBUS RS485, ProfiNet is Selectable
ƒ Digital and analogue I/O optional cards
ƒ Support different PG cards, including resolover
ƒ Suitable AC Inductiion Motor, Permanent
Magnet Synchronous Motor is selectable

Item Specifications
V/F Control
Control Mode Sersorless Flux Vector Control, SFVC
Closed-Loop Vector Control, FVC, Above 3.7kW
Max. Frequency 0.0-600.0 Hz
0.5 kHz-8.0 kHz
Carrier Frequency
The Carrier Frequency is Automatically Adjusted Based on the Load Features.
Digital Setting 0.01 Hz
Input Frequency Resolution
Analog Setting Max. Frequency x 0.025%
G Type 0.5 Hz / 150%, SVC
Start Torque
P Type 0.5 Hz / 100%
Speed Range 1:100, SVC
Speed Stability Accuracy ±0.5%, SVC
G Type 60s for 150% of the Rated Current, 3s for 180% of the Rated Current.
Overload capacity
P Type 60s for 120% of the Rated Current, 3s for 150% of the Rated Current.
Basic Function

Torque boost Auto-Boost; Customized Boost: 0.1%~30.0%


Straight-Line Ramp.
Ramp Mode Four Groups of Acceleration/Deceleration Time with the Range of 0.00-6500.0s
DC Braking Frequency 0.00Hz~Maximum frequency
DC Braking Braking Time 0.0s~36.0s
Braking Action Current Value 0.0%~100.0%
JOG Frequency Range 0.00 Hz-50.00 Hz
JOG control JOG Acceleration/Deceleration Time: 0.0s~6500.0s
Simple PLC, Multiple Preset Speeds It Implements up to 16 Speeds via the Simple PLC Function or Combination of Terminal States
Onboard PID It Realizes Process Controlled Closed Loop Control System Easily
Auto voltage regulation(AVR) It Can Keep Constant Output Voltage Automatically when the Mains Voltage Changes
The current and voltage are limited automatically during the running process so as to avoid
Overvoltage / Overcurrent Stall Control
Frequent Tripping Due to Over Voltage/Over Current.
Rapid Current Limit It Helps to Avoid Frequent Over Current Faults of the AC Drive.
It can Limit the Torque Automatically and Prevent Frequent Over Current Tripping During the
Torque Limit and Control
Runing Process. Torque Control can be Implemented in the FVC Mode.
Control of Asynchronous Motor are Implemented Through the High-Performance Current Vector
High Performance
Control Technology.
Individualized

The Load Feedback Energy Compensates the Voltage Reduction so That the AC Drive can Continue
Rapid Dip Ride Through
to Run for a Short Time
Functions

Support for Multiple PG Card Support for Differential Input PG Card, Resolver PG Card, Rotating Transformer PG Card...
Rapid Current Limit It Helps to Avoid Frequent Over Current Faults of the AC Drive.
Timing Control 0.0-6500.0 min.
Communication Methods RS 485 standard, ProfiNet is selectable
Operation Panel / Control Terminals / Serial Communication Port
Command Source You can Perform Switchover Between these Sources in Various Ways.
There are Ten Frequency Sources. Digital Setting, Analog Voltage Setting, Analog Current Setting,
Frequency Source
Pulse Setting, Serial Port Setting. You can Perform Switchover Between these Sources in Various Ways.
Standard: 5 Digital Input Terminals (Below 5.5kW)/6 Digital Input Terminals (Above 7.5kW);
Input Terminal 1 Analog Input Terminal (Below 5.5kW)/2 Analog Input Terminals (Above 6.5kW);
Running

1 Voltage Input (Only Support for 0-10V, Above 7.5kW), 1 Voltage Input (0-10V) or Current Input (4-20mA)

1 High-Speed Pulse Output Terminal (Open-Collector), Above 3.7kW.


Output Terminal 1 Relay Output Terminal (Below 5.5kW)/2 Relay Output Terminals (Above 7.5kW)
1 Analog Output Terminal (3.7-5.5kW)/2 Analog Output Terminal (Above 7.5kW),
Support for 4-20mA Current Output or 0-10V Voltage Output

3
NZ2000
General Purpose, Sensorless Vector Control

ƒ Auto Identification, Simple to use


ƒ PID Process Control, Multi-Function I/O
ƒ Heavy Duty Use (3s 180%, 60s 150%)
ƒ Support MODBUS, EtherCAT is selectable
ƒ Power Range 0.4-280 kW
ƒ Drives AC Induction Motor; Permanent
Magnet Synchronous Motor is Selectable

Item Specifications
V/F Control
Control Mode
Sersorless Flux Vector Control, SFVC
Vector Control 0.0-320.0 Hz
Max. Frequency
V/F Control 0.1-3200 Hz
1.0 kHz-16.0 kHz
Carrier Frequency
The Carrier Frequency is Automatically Adjusted Based on the Load Features.
Digital Setting 0.01 Hz
Input Frequency Resolution
Analog Setting Max. Frequency x 0.025%
G Type 0.5 Hz / 150%, SFVC
Start Torque
P Type 0.5 Hz / 100%
Speed Range 1:100, SFVC
Speed Stability Accuracy ±0.5%, SFVC
G Type 60s for 150% of the Rated Current, 3s for 180% of the Rated Current.
Overload Capacity
P Type 60s for 120% of the Rated Current, 3s for 150% of the Rated Current.
Torque Boost Fixed Boost; Customized Boost 0.1%~30.0%
Straight-Line Ramp; S-Curve Ramp
Ramp Mode
Four Groups of Acceleration/Deceleration Time with the Range of 0.00-6500.0s
DC Braking Frequency 0.00Hz~Maximum frequency
DC Braking Braking Time 0.0s~100.0s
Braking Action Current Value 0.0%~100.0%
Basic Function

JOG Frequency Range 0.00 Hz-50.00 Hz


JOG control
JOG Acceleration/Deceleration Time: 0.0s~6500.0s
Simple PLC, Multiple Preset Speeds It Implements up to 16 Speeds via the Simple PLC Function or Combination of Terminal States
Onboard PID It Realizes Process Controlled Closed Loop Control System Easily
Auto voltage regulation(AVR) It Can Keep Constant Output Voltage Automatically when the Mains Voltage Changes
The current and voltage are limited automatically during the running process so as to avoid
Overvoltage / Overcurrent Stall Control
Frequent Tripping Due to Overvoltage/Over Current.
Rapid Current Limit It Helps to Avoid Frequent Over Current Faults of the AC Drive.
It can Limit the Torque Automatically and Prevent Frequent Over Current Tripping During the
Torque Limit and Control
Runing Process.
Control of Asynchronous Motor are Implemented Through the High-Performance Current Vector
High Performance
Control Technology.
Running Command Channel Given by the Panel, Control Terminals, Serial Communication Port, can be Switched by Many Ways.
There are Ten Frequency Sources. Digital Setting, Analog Voltage Setting, Analog Current Setting,
Frequency Source
Pulse Setting, Serial Port Setting. You can Perform Switchover Between these Sources in Various Ways.
Auxiliary Frequency Source 10 kinds of Frequency Sorce, can be easlly reallze Micro Adjust, Frequency Synthesizer
Timing Control 0.0-6500.0 min.
Communication Methods RS 485, EtherCAT is optional
6 Digital Input Terminals, One of Which Supports up to 100 kHz High-Speed Pulse Input (Optional).
Input Terminal 2 Analog Input Terminals, One of Which Only Supports 0-10V Voltage Input and the Other Supports
Input & Output

0-10V Voltage Input or 4-20mA Current Input.


1 Digital Output Terminal
1 Relay Output Terminal
Output Terminal 1 Analog Output Terminal, That Supports 0-20mA
Current Output or 0-10V Voltage Output
Motor Shourt-Circuit Detection at Power-On, Output Phase Loss Protection, Over-Current Protection
Protection Function , Overheat Protection and Overload
Others

It can Lock the Keys Parlially or Completelly and Define the Function Range of
Key Locking and Function Selection Some Keys so as to Prevent Mis-Function.
Protection Class IP20

4
NZ8000
High Performance & Powerfull, Heavy Duty

ƒ Various Control Version, V/F, Sensorless


Vector and Cloosed Loop Vector Control
ƒ Modbus RS 485, Profibus-DP, CANopen
Communication Mode
ƒ Flexible Programmable I/Os
ƒ Heavy Duty 150% 60s, 180% 3s
ƒ Wide Operating Voltage 220 to 690 VAC

Item Specifications
V/F Control
Control Mode Sersorless Flux Vector Control, SFVC
Closed-Loop Vector Control, FVC, Above 3.7kW
Vector Control 0.0-320.0 Hz
Max. Frequency
V/F Control 0.0-3200.0 Hz
1.0 kHz-16.0 kHz
Carrier Frequency
The Carrier Frequency is Automatically Adjusted Based on the Load Features.
Digital Setting 0.01 Hz
Input Frequency Resolution
Analog Setting Max. Frequency x 0.025%
G Type 0.5 Hz / 150%, SFVC; 0.0 Hz / 180%, FVC
Start Torque
P Type 0.5 Hz / 100%
Speed Range 1:100, SFVC / 1:1000, FVC
Speed Stability Accuracy ±0.2%, SFVC / ±0.02%, FVC
Torque Control Accuracy ±5%, Cloosed-Loop Vector Cotrol FVC Mode
G Type 60s for 150% of the Rated Current, 3s for 180% of the Rated Current.
Overload capacity
P Type 60s for 120% of the Rated Current, 3s for 150% of the Rated Current.
Basic Function

Torque boost Fixed- Boost; Customized Boost: 0.1%~30.0%


Straight-Line Ramp.; S-Curve Ramp;
Ramp Mode
Four Groups of Acceleration/Deceleration Time with the Range of 0.00-6500.0s
DC Braking Frequency 0.00Hz~Maximum frequency
DC Braking Braking Time 0.0s~100.0s
Braking Action Current Value 0.0%~100.0%
JOG Frequency Range 0.00 Hz-50.00 Hz
JOG control JOG Acceleration/Deceleration Time 0.0s~6500.0s
Onboard Multiple Preset Speeds It Implements up to 16 Speeds via the Simple PLC Function or Combination of Terminal States
Onboard PID It Realizes Process Controlled Closed Loop Control System Easily
Auto voltage regulation(AVR) It Can Keep Constant Output Voltage Automatically when the Mains Voltage Changes
The current and voltage are limited automatically during the running process so as to avoid
Overvoltage / Overcurrent Stall Control
Frequent Tripping Due to Over Voltage/Over Current.
It can Limit the Torque Automatically and Prevent Frequent Over Current Tripping During the
Torque Limit and Control
Runing Process. Torque Control can be Implemented in the FVC Mode.
Control of Asynchronous Motor and Synchronous Motor are Implemented Through the
High Performance
High Performance Current Vector Control Technology.
Individualized

The Load Feedback Energy Compensates the Voltage Reduction so That the AC Drive can Continue
Rapid Dip Ride Through to Run for a Short Time
Functions

Differential Input PG Card / Resolver PG Card / Rotating Transformer PG Card


Support for Multiple PG Card U VW Differential Input PG Card / OC Input PG Card
Rapid Current Limit It Helps to Avoid Frequent Over Current Faults of the AC Drive.
Timing Control 0.0-6500.0 min.
Communication Methods Modbus (Standrad), Profibus-DP, CANopen
Operation Panel / Control Terminals / Serial Communication Port
Running Command Source You can Perform Switchover Between these Sources in Various Ways.
Digital Setting, Analog Voltage Setting, Analog Current Setting,
Frequency Source
Pulse Setting, Serial Port Setting. You can Perform Switchover Between these Sources in Various Ways.
8 Digital Input Terminals, One of Which Supports up to 100 kHz High-Speed Pulse Input
Input Terminal 2 Analog Input Terminal, One of Which Only Supports 0-10V Voltage Input and
Running

the Other Suppports 0-10V Voltage Input or 4-20 mA Current Input.


1 High-Speed Pulse Output Terminal (Open-Collector) that Supports 0-100kHz Square Wave Signal Output
Output Terminal 1 Digital Output Terminal
2 Relay Output Terminal
2 Analog Output Terminal - that Supports 0-20mA Current Output or 0-10V Voltage Output.
Protection Function Motor shourt-circuit detection at power-on, output phase loss, over-current, overheat, under voltage and overload

5
Coated heatsink

NZS Power range Max. up to 110 kW


as Standard

IP65/IP54 Class, V/F and Sensorless Vector Control

ƒ High Level Protection Class, Outdoor Application


ƒ Various Version Control Mode, V/F and SFVC
ƒ Pumps Application/General Purpose Selectable
ƒ Compact, Rugged Design. It can be Directly Installed
on the Motors or on Virtually any Other Mounting
Surface Based on the Application Requirements.
ƒ Master/slave system makes this easy to set pumps

Item General Purpose Version Pumps Application Version

Control Mode V/F Control / Sersorless Flux Vector Control Selectable V/F Controll, Space Vector Control

Vector Control 0.0-320.0 Hz


Max. Frequency 0.1-400 Hz
V/F Control 0.1-3200 Hz
1.0 kHz-16.0 kHz The Carrier frequency is automatically
Carrier Frequency 1.0 kHz-15.0 kHz
adjusted based on the load features.
Digital Setting 0.01 Hz Digital Setting 0.1 Hz
Input Frequency Resolution
Analog Setting Max. Frequency x 0.025% Analog Setting Max. Frequency x 0.1%
G Type 0.5 Hz / 150%, SFVC
Start Torque 0.5 Hz / 100%
P Type 0.5 Hz / 100%
Speed Range 1:100, SFVC /
Speed Stability Accuracy ±0.5%, SFVC /
G Type 60s for 150% / 3s for 180% of rated current
Overload Capacity 60s for 120%/3s for 150% of rated current
P Type 60s for 120%/3s for 150% of rated current
Auto-raise torque by loading condition;
Torque Boost Fixed Boost; Customized Boost 0.1%~30.0%
Manual increase 0.0-20% of rasing torque
Straight-Line Ramp; S-Curve Ramp
Ramp Mode 4 Groups of Acceleration/Deceleration Time with Straight-Line Ramp, the Range of 0.0-999.9.0s
the Range of 0.0-6500.0s
DC Braking Frequency 0.0 Hz-Max.frequency DC Braking Frequency 0.0-10.0Hz
DC Braking Braking Time 0.0s~100.0s Braking Time 0-25.0s
Braking action current value 0.0~100.0% Braking action current value 0-150%
Basic Function

Frequency Range 0.00 Hz-50.00 Hz Frequency range 0.0 Hz-Max.frequency


JOG control
Acce-tion/deceleration time 0.0-6500.0s Acce-tion/deceleration time 0.0-999.9s
It implements up to 16 speeds via the simple PLC 4 multiple terminals, It implements up
Simple PLC, Multiple Preset Speeds
Function or combination of terminal states to 15 speeds
It realizes process Controlled Closed Loop Control
Onboard PID system easily Built-in PID
It can keep constant output voltage automatically Automatic voltage regulation function can be
Auto voltage regulation(AVR)
when the mains voltage changes selected as required
The current and voltage are limited automatically
Overvoltage / Overcurrent Stall Control during the running process so as to avoid The overvoltage protection can be set
frequent tripping due to overvoltage/over current.
There are 10 frequency sources. digital set, analog voltage Analog input 0 to 10V, 0to 20mA can be selected
Frequency Source set, analog current set, pulse set, serial port set, you directly set by keyboard, RS485 set, up/down set
can perform switchover between these Sources in various ways. and others various ways
6 Digital Input Terminals,1 of which supports up to 100 kHz
high-speed pulse Input (Optional).2 analog input terminals, 4 multi-function Input terminals, 1 analog input terminal,
Input & Output

Input Terminal 1 of which only supports 0-10V voltage Input and the other supports 0-10V voltage input or 4-20mA current input.
supports 0-10V voltage Input or 4-20mA current input.
1 digital output terminal
2 relay output terminal (0.75-5.5 kW)
Output Terminal 1 relay output terminal
1 relay output terminal (7.5kw and above)
1 analog output terminal, that supports 0-20mA or 0-10V
10 kinds of frequency source, can easily realize micro
Others Built-in 2 groups of counters
adjust, frequency synthesizer
Protection Function Motor shourt-circuit detection at power-on, output phase loss, over-current, overheat, under voltage and overload
Communication Methods RS 485
Protection Class IP54 ( Above 3.7kw) /IP65 ( below 3.7kw), outdoor
Mounting Mode Mounted on the motor or on wall
Indication LED indiction parameters
Vibration feature less 5.9 m/s2 (0.6g)

6
Efficient
PDS-7
Cooling
Aluminum
Radiator Pumps Drives -Wall-Mounted Type
220 / 380VAC; 1HP - 3HP
ƒ Compact, Directly Mounted on Motors
ƒ Using DSP high-speed digital processor and
Flexible high-performance IGBT, the circuit is mature
Mounting
and the performance is stable.
Panel
ƒ Easy to Use, Suitable to Any Pumps
ƒ Built-in PID, PLC; Max.Frequency up to 999.9 Hz
ƒ V/F Control Mode; Performance Load Capacity

Item Specifications
220 VAC, 50/60Hz, 1 Phase Input and 3 Phase Output
Rated Voltage
380 VAC, 50/60Hz, 3 Phase Input and 3 Phase Output PDS-7 wall-mounted frequency converter for fixed-
Power Supply speed equipped with asynchronous motors. Its a new
220 VAC 170-240 VAC
Voltage Range generation of high-end intelligent integrated compact
380 VAC 330-440 VAC
water supply special products independently researched
220 VAC 0-240 VAC
Voltage Range & developed by NIETZ.
Output 380 VAC 0-380 VAC
Frequency Range 0.0-999.9 Hz
Control Mode V/F Control It can be installed on various brands of Pump Motor
Carrier frequency setting 0.5-16.0 kHz terminalboxes, and can be accessed in various types
Output Frequency Range 0.0-999.90 Hz of sensor signal, saving panel space and cost.
Digital Input 0.1 Hz
Frequency Setting Resolution
Analog Input 0.025% of Max. Output Frequency
G type 0.5 Hz /150% ƒ Newly developed SOFTWARE 2.0 platform, using
Startup Torque modular design, software performance is excellent
P type 0.5 Hz / 100%
Speed Range and stable.
1:100
G type 150% of rated current, 60s; 180% of rated current, 3s ƒ Adopt a new space vector algorithm with a reliable
Overload Capacity
P type 120% of rated current, 60s; 150% of rated current, 3s
protection mechanism.
Torque Boost Manual mode 0.1%~30.0%
Acce-tion & deceleration curve time 0-999.9s, 4 types acc-tiion/deceleration time ƒ Integrated enhanced PID control algorithm: with
Basic Specification

DC Braking Frequency 0.0 Hz-Max.frequency sleep wake-up,antifreeze, disconnection detection,


DC Braking Braking Time 0.0-36.0s high & low pressure alarm, water shortage detection,
Braking action current value 0.0~100.0% water shortage shutdown, automatic operation after
JOG frequency range 0.0Hz~50.00Hz water supply, automatic fault reset and other functions.
JOG control
Acce-tion/deceleration time 0.0s~999.9s
ƒ Featuring simple operation, good reliability, low
It implements multi-speeds via the built-in PLC function or noise and high performance.
Multi-Speed, PLC operation
combination of terminal states
Integrated enhanced PID control algorithm: with sleep, wake-up,
Onboard PID software antifreeze, disconnection detection, high and low pressure alarm,
water shortage detection, automatic operation after water supply
/ fault reset and other functions TECHNICAL FEATURES
It can keep constant output voltage automatically when the mains
Automatic Voltage Regulation
voltage changes
m2

Communication RS-485
r, m

cto net

A t
nt, pu
e D cuit

r, A

nt, t

I/O phase loss protection, over current protection, over voltage


ete

nta ag

rre pu
kW

rre ut
ake it
r, A

A
am

Co trom
Bre Circu
Wir Cir

Cu ed In

Cu ted O

Protection Functions protection, under voltage protection, overheat protection and


er,

i
n

overload protection
Pow

c
i

at
Ma

Ele
Air

Ra
R

2 digital input terminals; / / / / / /


Input Terminals 2 analog,each of which supports 0~10V or 4~20mA current input; I I I I I I
Input & Output, others

220V ±15% 0.75 1.0 25 13 7.2 5


Frequency Source Digital, analog voltage, analog current, serial port. Can be
1 Phase Input, 1.5 1.5 25 18 10 7
switching in various ways.
3 Phase output 2.2 2.0 25 25 13 9
Command Source Operation panel/Control terminals/Serial communication port
1 transistor output terminal
Output Source 1 relay output terminal 380V ±15% 0.75 0.5 10 6 3.5 2.1
Protection Class IP20 3 Phase Input, 1.5 1.0 10 9 5 3.7
3 Phase output 2.2 1.0 10 10 5.8 5
Installation Mode Mounted on the Motor Directly or Wall-Mounted

7
WP9
Multi-Pumps Control

ƒ V/F Control, Sensorless Vector Control


ƒ Controls max. 4 water pumps after add relay output
ƒ Heavy Duty Use (3s 180%, 60s 150%)
ƒ Support MODBUS via RS485
ƒ 24 VDC power supply support to Current sensor
ƒ STO Function more Effecient Protect the Pumps

Advantage and Features Item Specifications


Control Mode V/F Control, Sensorless Verctor Control
WP-9 multiple pump Variable Speed Drive is Max. Frequency 0.0-600.0 Hz
for controls multi-pumps, max. 4 in parallel, The 0.5 kHz-12.0 kHz The Carrier Frequency is Automatically
Carrier Frequency
inverter selects which pumps will operate in order Adjusted Based on the Load Features.
to keep/control the process value of the pumping Digital Setting 0.01 Hz
system. An alternation between their activation is Input Frequency Resolution
Analog Setting Max. Frequency x 0.025%
also performed, making it possible an equal use of
G Type 0.5 Hz / 150%
the pumps. Start Torque
P Type 0.5 Hz / 100%
Speed Range 1:200
X Features
Speed Stability Accuracy ±0.5%, SFVC
ƒ Full protection for pumping systems and maxi- G Type 60s for 150%; 3s for 180% of rated current
Overload Capacity
mized usability through special functions P Type 60s for 120%; 3s for 150% of rated current
The key directly adjusts the target pressure Torque Boost Auto-boost; Manuals adjust range 0.1%~30.0%
X X

ƒ Power off,then when the power is restored, it V/F Curve Linear/ Multi-Point and N-th Power V/F Curve
will automatically restart the running function. V/F Separation Full Separation and Half Separation
ƒ Extended relay output can achieve one inverter Straight-Line Ramp; S-Curve Ramp
Ramp Mode
control 4 constant pressure water supply pump. 4 Groups of Acce-tion/Dece-tion time 0.0-6500.0s
ƒ 24VDC power supply to power the current sensor. DC Braking Frequency 0.0Hz to Max. frequency
The Drive has the intelligent judgment function DC Braking Braking Time 0.0s~36.0s
of dormancy. Braking Action Current Value 0.0%~100.0%
ƒ English keyboard displays target value and JOG Frequency Range 0.00 Hz-50.00 Hz
JOG control
feedback value. JOG Acceleration/Deceleration Time 0-6500.0s
Basic Function

ƒ It can be extended to 4 pumps for water supply, Simple PLC, Multiple It Implements up to 16 Speeds via the Simple PLC
including stabilized pressure pump and variable Preset Speed Function or Combination of Terminal States
frequency pump. Onboard PID It Realizes Process Controlled Closed Loop Control System Easily
Auto voltage regulation It Can Keep Constant Output Voltage Automatically
ƒ It supports the online selection function of feed-
(AVR) when the Mains Voltage Changes
1 pump and 1 frequency conversion linkage control
completes constant pressure water supply function. Overvoltage/ The current and voltage are limited automatically during the running
Overcurrent Stall Control process so as to avoide Frequent Tripping Due to Overvoltage/Over Current.
ƒ The keyboard can start the constant pressure Rapid Current Limit It Helps to Avoid Frequent Over Current Faults of the AC Drive.
water supply control function, can have the stop
It can Limit the Torque Automatically and Prevent Frequent
function and the fault reset function. Torque Limit and Control
Over Current Tripping During the Runing Process.
Can realize 1 contrl 2-3, add expasion water supply card, can realize
Multi-Pumps control
Security Alarm Function max.4 pumps
X

Running Command Given by the Panel, Control Terminals, Serial Communication


ƒ High water pressure alarm function, low water Channel Port, can be Switched by Many Ways.
pressure alarm function 10 Frequency Sources. Digital, Analog Voltage , Analog Current, Pulse, Serial
Frequency Source
ƒ Protection function of water shortage Port. You can Perform Switchover Between these Sources in Various Ways.
Antifreeze function 10 Multiple Auxiliary frequency source. Flexible realization of auxiliary
Auxiliary Frequency Source
ƒ
ƒ Detect sensor disconnection frequency fine-tuning and frequency synthesis.
Automatic reset of water shortage fault
Timing set/ Communication 0.0-6500.0 min./ RS485
ƒ
Multi-pump control, fault pump is manually cut off
6 Digital Input terminal
Input Terminal 2 Analog Input Terminals, 1 of Which Only Supports 0-10V and the
Other Supports 0-10V or 4-20mA
Input & Output

1 Digital Output Terminal MO1


Optional Water Supply 2 Relay Output Terminal RA, RB, RC/TA, TC
Output Terminal 2 Analog Output Terminal,That Supports 0-20mA
Card can be control
Current Output or 0-10V Voltage Output
Max. 4 pumps
Output phase loss, overcurrent, overvoltage, undervoltage, overheat
Protection Function
, overload protections, etc.

8
APV
Integrated Pumps Drives -Wall-Mounted Type
220 / 380VAC; 1HP - 3HP

ƒ Compact, Directly Mounted on Motors


ƒ Robust Enclosure, High Protection Class
ƒ Easy to Use, installation
ƒ Advanced Pumps Control Function
ƒ V/F Control; Max. output frequency 999.9 Hz

APV - Integrated Pumps Control

2
mm

cto net

nt, put
ter,
ia it

r, A

nt, ut
g
u
kW

t
Co roma
me

ake t

Cu d Inp
r, A

A
Wir Circ

Cu d Ou
Bre ircui
er,

eD
APV is a new generation of high-end intelligent integrated ultra-

nta

rre

rre
in

ct

e
Pow

Rat

Rat
Ma

Ele
Air
high protection water supply special products independently
researched and developed by NIETZ
220V ±15% 0.75 0.75 16 12 7.2 4.5
1 Phase Input, 1.5 1.5 25 18 10 7
The Variable Speed Drives is dustproof and waterproof, and can be 3 Phase output 2.2 2.5 32 25 16 10
installed on various brands of pump motor terminal boxes, and can
be accessed in various types of sensor signal. Can be use in dirty
380V ±15% 0.75 0.75 6 9 3.8 2.5
and damp environments, even with low pressure jets; saving panel
space and cost. 3 Phase Input, 1.5 0.75 10 9 5 3.7
3 Phase output 2.2 0.75 10 9 5.8 5
ƒ Compact & Robust

ƒ Easy to use, directly mounted on motor pumps.


Dimenstion, mm
ƒ Protection class IP65, can be use at outdoor, dusty, moist

ƒ In order to mechanically install the drive controller on the motor,


the adapter is used in place of the terminal box. any motor can
be adapted.

164
133
NIETZ

Compact & robust 180


Motor adapter plate Aluminum heat sink
Simple mounting on motor
In order to mechanically
install the drive controller on
112

the motor, the adapter is


used in place of the terminal
box. any motor can be
adapted.
70
70

5.2

9
CV20
Solution for Industrial Crane and Hoist

ƒ Sensorless Vector Control, Closed-Loop Vector Control


ƒ Professional brake timing control; start and stop
smoothly without slipping the hook to prevent the
cargo from sliding down
ƒ Intelligent anti-sway, Load holding function
ƒ Built-in Brake Unit, Heave Duty

Advantage and Features


Professional brake timing control
According to the frequency, output current and torque of the CV20 AC drives with built-in crane control software, brake
inverter, the brake release command will be output. When unit and range of safety functions help various types of cranes
starting and stopping, keep the necessary torque to stabilize the move efficiently. Our CV20 drives are an excellent choice for
cargo, and open the holding brake, and start / stop smoothly standalone cranes
without slipping
CV20 series inverter special for hoisting is tailor-made for
various severe application conditions in the hoisting industry,
Brake failure detection and it can easily solve technical and performance problems.
When the stop brake is valid, the encoder is used to detect
whether the brake is invalid. If it fails, the inverter is automa- CV20 adopts vector frequency conversion control technology,
tically started to maintain torque to prevent accidents (Valid Closed Loop). while maintaining excellent performance and function, from the
Light load speed increase adaptive perspective of lifting application, it is superior in terms of ease of
use, maintainability, environmental protection, installation space
Through the light load speed-increasing function, the best running
and design standards to similar products. With high-performance
speed matching the load can be achieved. When the load is light,
it allows automatic speed increase and improves efficiency, no current vector technology, it can easily drive asynchronous induction
auxiliary ho ok design is required, which can shorten the operating motors to meet the working requirements in various environments
period of the crane witha long head.
X Features
Intelligent anti-sway
With built-in anti-sway function, so can suppress the shaking of ƒ Rope Length Detection
the goods during translation. Since the load does not sway, The height information of the hook can be seen in the cab
it can be laid down faster, which is beneficial to shorten the just by the inverter. When the wire rope reaches the set
operating cycle. CV20 drives with integrated sensorless control length, the collision with the lifting drum can be avoided by
functionality enhance productivity and safety by avoiding sway reducing the ascent and descent speed.
in cranes.
ƒ Rapid Deceleration
Stroke Limit Control By inputting a quick stop command through the terminal,
By the limit sensor input can prevent the hook from overtraveling it can perform rapid deceleration near the target position.
and excessive hoisting. ƒ Load Holding Function
When stopped, the load can be kept at the current position
through zero-speed control. Close the brake when it is stable.
Open and Closed Loop Control
CV20 drives help to ensure excellent open-loop crane performance ƒ Overload Detection
without encoders. Travel and hoist commissioning is simple. The torque rise value is detected when the cargo accidentally
Droop control equalizes torque between the two motors contacts other objects. At this time, the motor can be automatically
operating in parallel. Closed loop control offers even better stopped to prevent accidents and improve safety.
crane dynamics. We offer flexible encoder interfaces for broad
ƒ Self-Tuning Motor Parameter
component choice.
It can accurately identify asynchronous induction motors and
achieve high-performance vector control; It can achieve accurate
setting of motor parameters of long-distance ower cables
under load, and can automatically discriminate encoder signal
directions under encoder conditions, simplifying the debu-
gging process.
Crane Types Served
ƒ Parameter macro
ƒ Bridge crane, Overhead crane, Process crane The function to select the purpose according to the crane action.
ƒ Rail-mounted gantry crane, Goliath crane Just select hoist, long travel, trolley and other uses, you can
ƒ Rubber tired gantry crane, RTG crane, Grab crane automatically set the necessary and unnecessary functions to be
ƒ Marine crane, Mobile crane, Mobile harbor cane valid or invalid. The best parameters can be set simply for
different purposes.
ƒ Ship to shore crane (STS crane), container crane
ƒ Tower crane, Construction hoist, Port Crane

10
ESD / ESD2
For Small Power AC Motors

ƒ Mini Dimension, Low Cost


ƒ Potentionmeter Knob to Covenient Adjust
to Speed Regulation, Optimized Structure
ƒ ESD2 series Support MODBUS via RS485
ƒ V/F Control; 220V, Easy to use
ƒ Frequency Range 1.0...99.0Hz/ 0.0...300.0Hz

ESD2 Variable Speed Drives ESD Variable Speed Drives

ESD2 series frequency inverter is a new generation


micro power variable speed drive, specially designed
for small power motor. Micro dimension, save installation
ESD frequency inverter is embedded small power
inverter, specially designed for small power motor. Small
space, instrument embedded structure, installation
dimension, save installation space, instrument embedded
is simple and compact. structure, installation is simple and easy to use.

Advantage and Features


Advantage and Features
ƒ Power range: 0.2~1.1 kW / 220V; V / F type control
Input / output: single / three phase
ƒ
ƒ Power range: 0.4~0.75 kW / 220V; V / F type control
Output frequency range 0-300 Hz, analog input 0-5 V
Input / output: single / three phase
ƒ
ƒ
Carrier frequency up to 38.4 kHz
ƒ
ƒ Output frequency range 1-99 Hz
Built-in MODBUS RS485, baud rate up to 9600 bps
With speed adjust potential device, also can outer
ƒ
ƒ
Forced air cooling
ƒ connect speed adjust potential device;
ƒ Potentiometer knob to convenient adjust to speed
ƒ Built-in MODBUS RS485, baud rate up to 9600 bps
regulation, optimized structure, forced air cooling
ƒ Adopt a new generation I P M module with complete ƒ Interior configured intelligent logic controller can
protection functions realize the simple, easy logic control function.
ƒ With electric thermal electric relay function and
DIMENSION other traditional motor protection device;
ƒ Can outer connect LED for indicate, convenient for
160 mm field use requirements;
ƒ Humanization operating interface, simple and clear
Plastic enclosure
the parameters setting, convenient for operating;
102 mm

Display
W: 52 mm
Potentiometer

W: 53 mm
Hole Spacing

L: 80 mm
90 mm

6*=
A 

/
* !
Hole Spacing
89.5 mm

Fan and Radiator 147 mm


L: 80 mm
Wiring terminals
2- 4.0 mm

2- 4.5 mm

Typical Applications

Suitable for electronic equipment, package equipments,


wood cutting machine, transportation belt, wire drawing
machine, etc.

11
AMD
AC Spindle Servo Drives / 380V, 0.4-160 kW

ƒ V/F Control, SFVC, FVC Control Mode


ƒ Controls AC Induction, Spindle Asynchronous Motor
ƒ Support Various Optional Encoder
ƒ Easy and flexible control; MODBUS RS485
ƒ Increadible Performance of Speed, torque and
position control; All protection

Item Specifications
Control Mode V/F Control, Sensorless Verctor Control, Closed-Loop Vector Control
Motor Types 3 Phase Induction Motor Spindle Asynchronous Motor
AMD series spindle servo drives is designed for Max. Frequency
V/F control mode 0-1500 Hz
numerical control machine of new type and high Vector control mode 0-1000 Hz
precision and it has new functions like positioning 0.8-16.0 kHz Adjust the frequecny automaticaally according to loading characteristics.
Carrier Frequency
control, pulse synchronous control and so on. It
supports FEEDBACK vector control towards the Digital Setting 0.01 Hz
Input Frequency Resolution
spindle motor with encoder. This drive has high Analog Setting Max. Frequency x 0.025%
responding ability towards speed as well as smooth Start Torque G Type - 0.5 Hz / 150% (SFVC) / 0.0 Hz / 180% ( FVC)
speed. It can achieve various functions like warrant Speed setting Range 1:100 SFVC 1:1000 FVC
stop of spindle; Rigid tapping; indexing positioning Speed Stability Accuracy ±0.5%, SFVC ±0.2%, FVC
and so on by cooperating with different numerical G Type 60s for 150%; 3s for 180% of rated current
control system. Overload Capacity
P Type 60s for 120%; 3s for 150% of rated current
Torque Boost Auto-boost; Manuals adjust range 0.1%~30.0%
V/F Curve Linear/ Multi-Point and N-th Power V/F Curve
X Features
Ramp Mode Straight Line Ramp; 4 Groups of Acce-tion/Dece-tion time 0.0-6500.0s
DC Braking Frequency 0.0Hz to Max. frequency
ƒ Multi encoder support; it can support differential
DC Braking Braking Time 0.0s~36.0s
encoder; ABZ encoder and so on.
Braking Action Current Value 0.0%~100.0%
ƒ Power dip ride-through, load feedback energy Simple PLC, Multiple It Implements up to 16 Speeds via the Simple PLC
compensates for any voltage reduction, allowing Preset Speed Function or Combination of Terminal States
the drive to continue to operate for a short time
Auto voltage regulation It Can Keep Constant Output Voltage Automatically
during power dips.
Basic Function

(AVR) when the Mains Voltage Changes


ƒ Overvoltage and overcurrent stall control; the Overvoltage/ The current and voltage are limited automatically during the running
system limits the output current and voltage Overcurrent Stall Control process so as to avoide Frequent Tripping Due to Overvoltage/Over Current.
automatically during operation to prevent frequent It can decrease the over-current fault on a maximum extent, thus
or excessive trips. Rapid Current Limit
protecting the normal operation of the spindle servo driver.
It can Limit the Torque Automatically and Prevent Frequent
ƒ Torque limit and control: the system limits the
torque automatically to prevent frequent over- Torque Limit and Control Over Current Tripping During the Runing Process. Can be adjust the
current tripping during operation. Torque control torque through FVC control mode.
is applied in vector control. Differential input PG card Open collector
Optional support PG cards
Rotating transformer PG card
ƒ Onboard multiple preset position: the system Running Command Given by the Panel, Control Terminals, Serial Communication
implements up to 16 position by using simple Channel Port, can be Switched by Many Ways.
PLC function or by using digital input signals. Multiple Auxiliary frequency source. Flexible realization of auxiliary
Auxiliary Frequency Source
frequency fine-tuning and frequency synthesis
Timing set 0.0-6500.0 min.
Communication ModBus RS485
6 Digital Input terminal
Input Terminal 2 Analog Input Terminals, 1 of Which Only Supports 0-10V and the
AC ASYNCHRONOUS SERVO MOTOR Other Supports 0-10V or 4-20mA
Input & Output

1 Digital Output Terminal MO1


2 Relay Output Terminal RA, RB, RC, YA, YB,YC
Output Terminal 1 Analog Output Terminal,That Supports 0-20mA
Current Output or 0-10V Voltage Output
Output phase loss, overcurrent, overvoltage, undervoltage, overheat
Protection Function
, overload protections, etc.

ƒ Small rotor inertia and rapid response


ƒ High Efficiency, Low energy consumption & noise.
ƒ Equipped with high-precision encoders proves higher positioning & speed accuracy.
ƒ Compact design, small electromagnetic vibration, high rotation precision, constant torque
ƒ Wide power range 2.2-132kW; Rated speed, 750-3000 rpm, Max. 4000-12 000 rpm

12
AT10 series
Electrohydraulic Servo Drive

ƒ Built-in CAN, MODBUS RS485 communications


12
ƒ Support single, double and multiple electro
hydraulic pump system
ƒ Variety of signal reference modes, more saving energy
ƒ Buit-in Brake unit. Heavy14Duty, 150% in 60s; 180% in 5s.
ƒ Voltage Supply 220 ~ 380 VAC; Powerfull 7.5 ~ 450 kW
ƒ Various protection functions such as phase loss, short
circuit, overheating detection and etc.
ƒ High-performance servo control: Vector control + field
weakening control + PID control
ƒ Support 0-10V DC / 4-20mA direct analog signal input
ƒ Fast and safe isolated terminal wiring
ƒ Performance Start torque: 0Hz 180%; Steady speed
accuracy: ± 0.02%; Torque control accuracy: ± 5%
ƒ Air cooling, liquid cooling way, Flexibility to use

Electro-Hydraulic ServoSystem combined both electrical and hydraulic characteristics can accurately X Flow-Converging and Dividing System
follow the command changes to adjust the output. With high precision, fast response, big output power,
flexible signal processing, easy to control, etc., it is widely used in various industries such as in Injection
molding machines, hydraulic presses, stamping and bending machines, etc. Multi-Pump Flow-Converging System

X ADVANTAGE
CAN bus
Pressure
Save Energy Consumption Noise Reduction Command
Optimized pressure and flow control algorithm Efficient reduction of Noise, less than 65dB Pressure
saving energy max. 80% improve equipments usage environment Command Main Slave Slave
Flow Drive Drive Drive
High Precision, Intelligence Save Volume and Place Feedback
Multiple Control modes of speed loop, current loop Suitable PM Synchronous Motor, Compact size
Oil Inlet Port
and pressure loop to ensure high precision repeatability. Compared with the open hydraulic circuit, save
75% tank volume
M M M
Pump A Pump B Pump C
Item Specifications Pressure Sensor

Control Mode V/F Control / Closed Loop Vector Control


1-12.0 kHz Automatically adjust the carrier frequency
Carrier frequency setting
according to the load characteristics. Oil Outlet Port

Output Frequency Range 0.0-599.00 Hz


Frequency Setting Digital Input 0.1 Hz Multi-Pump Distributed Flow System
Resolution Analog Input 0.025% of Max. Output Frequency
Startup Torque 0.0 Hz /180%
CAN bus
Speed Range 1:1000 ( FVC Mode Control)
Pressure Pressure Pressure
Overload Capacity 150% of rated current, 60s; 180% of rated current, 5s Command. 1 Command. 2 Command. 3
Torque Control Accuracy ± 5% ( FVC Mode Control) Main Pressure Slave Pressure Slave
Pressure
Steady Speed Accuracy ± 0.02% ( FVC Mode Control) Command. 1 Drive Command. 2 Drive Command. 3 Drive
Basic Specification

Acceleration and dece- Linear acceleration and deceleration. 4 kinds of ace-tion Pressure Pressure Pressure
Feedback.1 Feedback.2 Feedback.3
leration curves and dece-tion time, plus or minus time range 0.0 ~ 6500.0s.
Oil Inlet Port
Fast Current Limiting Min. Overcurrent faults,Protect the ServoDrive Pump
Pump Pump
Function to normal operation A M B M C M
Encoder Support Resolver Encoder Pressure Sensor 1 Pressure Sensor 2 Pressure Sensor 3

Overvoltage/ Overcurrent Automatically limits the current and voltage during running 8 9 < 3

Stall Control to avoid frequent tripping caused by overvoltage / overcurrent.


Communication RS-485 and CANbus Oil Outlet Port 1 Oil Outlet Port 2 Oil Outlet Port 3

I/O phase loss protection, over current protection, over voltage


protection, under voltage protection, overheat protection and ƒ Set the same speed for motors through communication
Protection Functions
overload protection ƒ Control the convergent/distributed flow of pumps 2 and 3 by
powering on and off solenoid valves 8 , 9 , < , and 3
Typical Applications ƒ When the convergent flow control is enabled, the pressure
and flow references and pressure feedback signals received
ƒ Air compressor, Pumping unit in oil field, etc. by slave drives are invalid.
ƒ Injection molding machines, hydraulic presses, ƒ When the distributed flow control is enabled, the CAN
stamping and bending machines, etc. communication references received by slave drives are invalid.

13
A t
u
ren put

rre utp
kW

A
Cur d In

Cu ed O
nt,
er,

t,
Power

e
Pow
Main Circuirt Terminal Description

Rat

Rat
Supply Wiring Diagram
/ / /
I I I
7.5 35 32
+/B1 R 11 46.5 45
B2 S
220V, 3 Phase, 7.5 ~ 18.5 kW

220V 15 62 60
380V, 3 Phase, 7.5 ~ 37 kW

220V, 3 Phase, 22 ~ 30 kW

380V, 3 Phase, 45 ~ 55 kW
R/L1 T 18.5 76 75
External Braking Resistor

r
cto
±15%

ea
cto
S/L2 -

R
22 92 90

ke
3 Phase

nta

ut
and

ea

Inp
and

Co
Br
U
T/L3 +/B1 30 113 110

AC Power Input
L1 L1 R R U
V
L2 L2 S S V
U/T1 B2 37 157 152 L3 L3 T T W
W
Shielded cable or
PE
V/T2 U 45 180 176 PE PE Armored cable
(Ground mear server
W/T3 V 55 214 210 AT10 Servo Drive terminal)

W 75 307 304
90 345 340 Input common terminal
Pump start-stop (enable)
R R 7.5 20 17 Reverse run
Forward jog
S S 11 26 25
380V, 3 Phase, 75 ~ 110 kW

380V, 3 Phase, 132 ~ 160 kW

Reverse jog
T T 15 35 32 Fault reset
220V, 3 Phase, 55 kW

Input common terminal


+/B1 B2 18.5 38 37 PE
220V, 3 Phase, 75 kW
and

Db9 female, rotating


and

EXC-
B2 22 46 45 transformer signal
- 9 EXC+
interface, optional


30 62 60 8 COS+
- +/B1


7 COS- Oil pump




37 76 75 6 SIN-
U U


SIN+
45 92 90


V V Analog
380V 55 113 110 Output 1 FOV1
W W GND Servo Motor
±15% 75 157 150 Analog
Output 2 FOV2
3 Phase 90 180 176 Pressure command FIV1 13V

110 214 210 signal input -10V~+10V Analog GND



GND
R U Input FIC
Pressure
132 256 253 Flow command FIV2 ±10V or 0-20mA sensor
S V signal input -10V~+10V
10V
(+) (-) 160 307 300
T W PT+ Motor overheating
185 355 340 protection: PT130
PT-
220V, 3 Phase, 90 kW 200 385 380 TA or PT150 and more
Relay output Normally open TC
and 220 430 420 Shielded cable
380V, 3 Phase, 132~160 kW KA RS+
250 468 470 Relay output Normally open KC RS- CAN Communication
RGND
CANH Differential signal
280 525 520 RB CAANL
PE
315 610 600 Relay output Normally closed RC
Terminal Code Function
350 665 640
R/L1, S/L2, T/L3 Voltage Input
400 700 690
Output Terminal of Drive
U/TI, V/T2, W/T3 Connect to AC Motor 3 ph.
DC Power + / -; Can be External Optional Resolver Encoder Terminal Arragement and Definition
+/B1, - connect to Brake Unit
visit www.nietz.cn for selection
1 REF- Resolver excitation “ -”
+/B1, B2 Connect to Brake Resitance
2 REF+ Resolver excitation "+"
Ground Terminal SIN+
Resistors 9 SIN- 3 COS+ Resolver feedback COS "+"

(+) / (-) Brake Unit Terminal COS-
8 4 COS- Resolver feedback COS "-"

COS+
7 5 SIN+ Resolver Feedback SIN "+"
AC, DC Chokes I/O

REF+ 6 / /
Main Circuit Wiring Exsample 6

 REF- 7 / /
8 / /
External EMC I/O
CN4 9 SIN- Resolver feedback SIN "-"
+/B1
Brake Resistance
B2
Model Code Description
-

AT10 7R5 G2 A R M
R/L1 Product Series

S/L2 380 VAC 7.5 kW = 7R5 Power,kW Communication Type


Power Supply 11 kW = 011 Software Modbus RS485 = M
T/L3 CANopen = C
Version A = A
U/T1 Cooling Fan (standard) = Blank
220 VAC = G2 Power Encoder Resolver
Code Type Method Oli ( customized)= Y
V/T2 380 VAC = G4 Supply

W/T3 Servo Motor

14
OPTIMIZE MOTOR CONTROL

SHANGHAI, CHINA

NIETZ ELECTRIC CO.,LTD DISTRIBUTORS

No.988, Fulian Rd. Gucun Tel/Fax: +86 21 336 346 49


Industry, Baoshan District. E-mail: [email protected]
Shanghai, China Website: www.nietz.cn