Slab Reinforcement Details
Slab Reinforcement Details
COMPANY
1 2 3 4 5 6 7 8 9 10 11 12
2400 900 1500 1900 1900 1600 2800 2500 2200 1600 3600
LTD
11Y8-05-200B2 24Y8-11-200T2 P.O BOX 3031-40100
Kisumu,Kenya
A
(3)
1100
6Y10-22-200B1
17Y10-29-200B1 10Y10-21-200B1 15Y10-39-200T1 8Y10-23-200B2
(4) (14)
18Y8-04-200T2
B
(4) (4) GENERAL NOTES
20Y10-25-200B1 8Y8-27-200T2
900
31Y10-01-200B1 1.) This drawing must be read in conjuction with relevant engineer`s and
architectural drawing(s).
C 2.) The contractor shall check all dimensions on site, any error, &/or
ommisions shall be reported to the engineer before work is
500
(3)
CONCRETE
1000
(11)
1.) Blinding under pad foundation to be 1:4:8 mix
2.) All reinforced concrete to be grade 30 mix giving a minimum
31Y8-02-200B2
13Y8-24-200B2 crushing strength of 25N/mm2 of 28 days.
(7)
31Y10-03-200T1
3.) Cement shall be portland cement to comply with BS 12
D 4.) Maximum aggregate size shall be 20mm unless otherwise stated.
500
(4)
25Y8-40-200T2 1.) R indicate hot rolled mild steel to BS4449
E (11) 19Y8-38-200B2 (8) 2.) H indicate cold rolled high tensile steel to BS4461
3.) Fabric reinforcement shall be to BS4483.
8Y10-31-200B2 4.) All reinforcement shall be presented to the engineer for inspection
1350
(7)
(13) (11) (8) 11Y8-49-200T2 COVER
32Y10-37-200T1 Unless otherwise stated cover to main steel shall
(5)
be as follows:
1.) 50mm to all steel below ground level.
F (4) (14) 2.) 40mm to columns above ground level.
300 350
(20)
18Y8-07-200T2 3.) 25mm to steel in beams.
14Y10-30-200B1
G 4.) 20mm to steel in slabs and staircase.
W O R KM AN S H IP
G1 (20)
1.) All concrete work to be in accordance with BS 8110.
2.) All reinforced concrete to be mechanically vibrated.
E X C AV AT IO N
(8)
1.) All excavations for foundation shall be presented to the engineer for
1500
8Y10-20-200T1
12Y10-34-200T1
his approval rior to placing of blinding.
(7)
2.) Depth of foundation on all drawings are provisional and the engineer
shall be consulted before final depth is arrived at during construction.
31Y10-06-200T1 G R O U N D F LO O R S LAB
24Y10-33-200B1
(7)
1.) Ground floor slab to be cast on well compactedand approved
H (8) (8)
hardcore as per specification and to be reinforced with one top layer
500
(8)
3. B1 Bottom first layer
900
(4)
13Y10-52-200B1
12Y10-16-200B1
(9)
I1
300
I2
(12)
700
18Y8-42-200B2
No. Description Date
(4)
(21)
17Y8-08-200B2
I3
400
(4)
(8) (10) 36Y8-15-200B2 (18)
K 18Y8-19-200B2
700
(4)
K1
(4)
(4)
500
25Y10-09-200B1 8Y8-13-200T2 22Y10-12-200T1 16Y8-18-200T2 13Y8-17-200T2 14Y10-10-200B1 12Y10-32-200T1 4Y8-36-200T2 21Y10-35-200T1 21Y8-44-200B2 21Y10-47-200T1 10Y10-51-200B1 10Y10-53-200T1 41Y10-43-200B1 23Y8-54-200T2
Client
Project :
Drawing Title :
TYPICAL SLAB & BEAMS REINFORCEMENT
DETAILS.
Drawn by S.o.Juma
Checked by
STRUCT/01/2023
A1
Scale: 1:50,1:20