0% found this document useful (0 votes)
158 views

Mini Link Nec Configuration

1. The document provides step-by-step instructions for configuring an iPasolink 200 digital microwave transmission system through the WebLCT interface. It includes steps for equipment configuration, radio configuration, E1/ETH capacity setting, date/time setting, TX power setting, network setting, VLAN setting, and checking link performance and alarms. 2. Configuration steps include setting the equipment name, modem parameters, E1/ETH channel mapping, IP addresses, VLAN IDs, and reviewing RX levels, BER, and performance metrics like UAS, ES, and SES. 3. The instructions are for internal use at ZTE Corporation and not to be spread externally without permission.

Uploaded by

davinder
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
158 views

Mini Link Nec Configuration

1. The document provides step-by-step instructions for configuring an iPasolink 200 digital microwave transmission system through the WebLCT interface. It includes steps for equipment configuration, radio configuration, E1/ETH capacity setting, date/time setting, TX power setting, network setting, VLAN setting, and checking link performance and alarms. 2. Configuration steps include setting the equipment name, modem parameters, E1/ETH channel mapping, IP addresses, VLAN IDs, and reviewing RX levels, BER, and performance metrics like UAS, ES, and SES. 3. The instructions are for internal use at ZTE Corporation and not to be spread externally without permission.

Uploaded by

davinder
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 18

iPasolink 200

Digital Microwave Transmission System


Fast Data Configuration Guide
内部公开 Internal Use Only▲

NE Login
1. Connect the PC to the LCT port of IDU.

2. Set the IP address for PC as OBTAIN DSN SERVER ADDRESS AUTOMATICALLY”

3. Input the IP address of the NE and WebLCT in URL Address box:


http://172.17.254.253.The WebLCT login window appears, as shown

4. Input User Name: Admin, and Password: 12345678in textbox.


5. Press OK. The WebLCT main window appears

<以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第2页
All Rights reserved, No Spreading abroad without Permission of ZTE
内部公开 Internal Use Only▲

Equipment Configuration
1. Expand Equipment Setup -> Equipment Configuration from the WebLCT
menu.
2. Click the Setup.

3. Input the Equipment Name, then Next.

<以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第3页
All Rights reserved, No Spreading abroad without Permission of ZTE
内部公开 Internal Use Only▲
4. Set Modem1 as used, and then click Next.

5. Confirm that the setup parameter changes to blue, and then click OK

<以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第4页
All Rights reserved, No Spreading abroad without Permission of ZTE
内部公开 Internal Use Only▲

6. Click OK in the pop-up Warning box.

<以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第5页
All Rights reserved, No Spreading abroad without Permission of ZTE
内部公开 Internal Use Only▲

Radio Configuration
1. Expand Equipment Setup -> Radio Configuration from the WebLCT menu.
2. Click Setup. The Step1 Window appears

3. Input Channel Spacing /Modulation/TX frequency from Link Budget, Radio


mode :High capacity, Frame ID :1, TX power control : MTPC. and then click Next
button.

<以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第6页
All Rights reserved, No Spreading abroad without Permission of ZTE
内部公开 Internal Use Only▲

4. Confirm that the setup parameter and then click OK

5. Click OK in the pop-up Warning box

<以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第7页
All Rights reserved, No Spreading abroad without Permission of ZTE
内部公开 Internal Use Only▲

E1/ETH Capacity Setting


1. Expand Provisioning -> MODEM Function Setting-> AMR / Radio Mapping
Configuration.

2. Input the E1 channels to be used, STM-1 must be 0, ETH bandwidth will be


calculated automatically, and then click Next button.

<以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第8页
All Rights reserved, No Spreading abroad without Permission of ZTE
内部公开 Internal Use Only▲
3. Confirm that the setup parameter and then click OK

4. Click OK in the pop-up Warning box

<以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第9页
All Rights reserved, No Spreading abroad without Permission of ZTE
内部公开 Internal Use Only▲

Date / Time Setting


1. Expand Equipment Utility -> Date/Time Setting->Modify

2. Set the date and time for IDU.

<以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第 10 页
All Rights reserved, No Spreading abroad without Permission of ZTE
内部公开 Internal Use Only▲

TX Power Setting
1. Expand Provisioning -> MODEM Function Setting-> TX Power Setting

2. Click the MODEM1 to configure. The TX Power Setting dialog box appears.

3. Assign a proper value for each parameter. Then, click OK


4. Click OK in the pop-up Information box.

<以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第 11 页
All Rights reserved, No Spreading abroad without Permission of ZTE
内部公开 Internal Use Only▲

Network Setting- Set IP for IDU


1. Click the Maintenance button on the top of the LCT window to turn on the maintenance
mode.
2. Expand Equipment Setup -> Network Management Configuration->General
Setting
3. Click Setup button. The General Setting box appears

4. The default IP address is 172.18.0.1 for Near End site IDU, 172.18.0.2 for Far
End site IDU.

<以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第 12 页
All Rights reserved, No Spreading abroad without Permission of ZTE
内部公开 Internal Use Only▲

E1 Port Setting
1. Expand Provisioning -> E1/STM-1/Cross Connect Setting -> E1 Port Setting

2. Click the Modify button. The E1 Port Setting (Main Board) dialog box appears

3. Assign a proper value for each parameter. Then, click OK


4. Click OK in the pop-up Information box

<以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第 13 页
All Rights reserved, No Spreading abroad without Permission of ZTE
内部公开 Internal Use Only▲

ETH Port Setting


1. Expand Provisioning-> ETH Function Setting -> ETH Port Setting

2. Click the desired Port No. to configure. The ETH Port Setting dialog box appear

3. Click OK in the pop-up Information box.

<以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第 14 页
All Rights reserved, No Spreading abroad without Permission of ZTE
内部公开 Internal Use Only▲

VLAN Setting-Adding
1. Expand Provisioning -> ETH Function Setting ->VLAN Setting

2. Click VLAN List tab. The VALN List tab appears.

3. Click the Add VLAN ID button to create a new VLAN ID.

<以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第 15 页
All Rights reserved, No Spreading abroad without Permission of ZTE
内部公开 Internal Use Only▲

VLAN Setting-Setting
1. Expand Provisioning-> ETH Function Setting-> VLAN Setting
2. Click Port No. button. The VLAN Setting window appears

3. Click OK in the pop-up Information box.

<以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第 16 页
All Rights reserved, No Spreading abroad without Permission of ZTE
内部公开 Internal Use Only▲

RX level & alarm Check


1. Expand Metering-> Current Metering

2. Click MODEM1

3. Confirm the RX level is up to the design value, and the BER is better than 0.0E-8.
4. Expand Current Status-> Active alarm

5. Confirm no alarm such as: LOF, RX level, ODU alarms.

<以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第 17 页
All Rights reserved, No Spreading abroad without Permission of ZTE
内部公开 Internal Use Only▲

Link Performance Check


1. Expand Current/History PMON/RMON Report --> MODEM PMON Report

2. Click Modem1

3. Confirm the value of UAS,ES, SES are 0 in the past 30 minutes.