0% found this document useful (0 votes)
111 views9 pages

Siemens Cv70

The ACUSON CV70 cardiovascular system is a powerful, portable, all-digital ultrasound platform. It uses the latest ultrasound technologies like MultiBeam imaging formation and precision motion capture. The system has a 15-inch monitor, internal hard drive for image storage, and supports DICOM. It offers various imaging modes like 2D, Doppler, triplex and has physiological interfaces. Measurements tools are provided for anatomical structure analysis.

Uploaded by

Abbas Abbas
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
111 views9 pages

Siemens Cv70

The ACUSON CV70 cardiovascular system is a powerful, portable, all-digital ultrasound platform. It uses the latest ultrasound technologies like MultiBeam imaging formation and precision motion capture. The system has a 15-inch monitor, internal hard drive for image storage, and supports DICOM. It offers various imaging modes like 2D, Doppler, triplex and has physiological interfaces. Measurements tools are provided for anatomical structure analysis.

Uploaded by

Abbas Abbas
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

Data

ACUSON CV70 Cardiovascular System


ACUSON CV70 Cardiovascular System

GENERAL INFORMATION Monitor


• MultiSync, 15-inch, high resolution, progressive scan
(non-interlaced)
The ACUSON CV70™ cardiovascular system is a • 800 x 600 pixel display matrix with a recordable image
powerful, portable multi-specialty imaging area of up to 800 x 600 pixels (SVGA)
platform that incorporates the latest generation • Monitor tilt of 10 degrees up, 8.5 degrees down and
of all-digital ultrasound technologies and proven swivel of 180 degrees
innovations, providing solutions in flexibility, • Digital on-screen display brightness and contrast controls
with factory default presets
workflow and performance.
• Energy Savings Compliant per VESA Display Power
Management Signaling standard
SYSTEM ARCHITECTURE
The powerful, all-digital core technology of MO Drive
the CV70 system is built on a combination of: • Removable, standard 3.5-inch 640 MB magneto-optical
technology migration from other ACUSON™ disk
ultrasound systems. MultiBeam Image • Allows storage of patient images, reports, and patient ID
Formation, multihertz and the Acuson integrated list, back-up for user and system presets
• Supports system software updates and upgrades
DIMAQ architecture.

• The all-digital architecture preserves the signal integrity of Hard Drive


all ultrasound information throughout the entire signal • Internal 40 GB Hard Drive for patient database
path – from transducer to display. management
• MultiBeam Image Formation – allows high frame rate • Allows storage of patient studies that include images,
imaging, for optimal color flow and motion visualization dynamic clips, reports and measurements
• Precision MotionCapture – utilizes the full spectrum of • Image storage capacity up to 42,000 images; color or
signal information which allow the accurate display of black/white, or storage of approximately 6,300 dynamic
cardiac structures for analysis clips
• DIMAQ integrated workstation – acquires, captures and
stores digital dynamic clips and static images without CD-RW Drive
interrupting the exam workflow. This technology is the • Removable 650 MB read/write CD-R
gateway to advanced features • Allows storage and archiving of patient studies that
include images, dynamic clips, reports and
User Interface measurements
• User-centric control panel with homebase layout • Storage capacity dependent upon patient study size
• Windows® based operating principles and on-screen icons • Export of images in DICOM (Optional), TIF and in AVI file
to activate most frequently used functions format
• Adjustable control panel back-lit illumination
• Intuitive active stage lighting Audio Speakers
• Digital Liquid Crystal Display (LCD) provides easy and • High performance audio speakers integrated with the
immediate access to secondary imaging controls monitor
• Wrist support to help reduce operator repetitive stress
disorders Transducer Ports
• Retractable alphanumeric keyboard with overhead • Two universal transducer ports that support Phased
illumination for standard text, function keys and system Array, Curved-Linear Array and Linear Array
programming • One MP transducer port that supports the V5M
• Up to 32 user-definable QuickSet™ user programmable Transesophageal transducer
system parameters programs for individual • Single dedicated port for CW pencil-type transducer
transducer/application settings. QuickSets combine all • Electronic transducer selection
preferred imaging mode parameters, annotation text and • Industrial design provides easy access to all transducer
measurements into one user preset ports
• Configurable two-pedal footswitch
Transducer Storage
Language Support • Six configurable transducer holders support all
• Image screen, control panel overlay and operating transducer designs and provide gel bottle storage
instructions all available in English, German, French, • Ergonomic cable management and secure cable
Spanish and Italian management during exams and transport

2
ACUSON CV70 Cardiovascular System

Acoustic Output Management • Parallel and quad Signal Processing with frame rate >
• On-screen acoustic power indicator 350 F/sec. transducer dependent
(AIUM/NEMA output display standard) • MultiHertz™ multiple frequency imaging with up to 5
user selectable transmit frequencies
• Res/Speed selection for Std (Standard), Dtl (High line
Physiological Interface density), and Far (SynAps)
• Standard 3-lead ECG interface
• 5 Persistence levels: off, 1 – 4
• Continuous display in all real-time modes
• 4 Edge enhancement levels: off, 1 – 3
• R-Wave Single and Dual Trigger function
• Display dynamic range: 35 to 70 dB in one-decibel
• Heart Rate display
increments
• Adjustable gain and trace position on screen
• Adjustable gain from 0 to 40 dB in one-decibel
• Selection for one external ECG (DC) input and one
increments, and total of 60 dB including DGC
Auxillary (DC) input
• 8 DGC controls for Depth Gain Compensation
• 6 user-selectable gray maps
OPERATING / DISPLAY MODES • 4 user-selectable 2D colorization maps (Sepia, Mag,
Temp, Bow and Tan)
• 2D imaging in fundamental and harmonic modes
• Tissue and color M-mode 2D Image Display
• SieScape™ panoramic imaging • Full screen, Split and Dual Select screen formats
• Axius™ edge-assisted Ejection Fraction (option)* • L/R for all formats in real-time and digital cine replay
• Color Doppler Velocity mode • 90 degree rotation of image for all sector transducers
• Power Doppler mode (Vascular only) • Image Depth from 2 to 24 cm in 0.5 or 1.0 cm
• Directional Power Doppler mode (Vascular only) increments – transducer dependent
• Spectral Doppler Tissue Imaging • Sector: selectable field of view from 10 to 90 degrees
• PW Pulsed Wave spectral Doppler mode • Left/right steer for all linear array transducers
• CW Continuous Wave spectral Doppler mode (Aux Pencil • Digital read/write zoom with image pan
style and phased array steerable) - Available on live and cine replay images
• Duplex mode - Up to 20 X zoom – transducer dependent
• Triplex mode (Vascular only)
• ECG trace in all modes 2D Calipers – Generic Measurements
• Flexible combination of imaging modes in side-by-side and Calculations
Dual and Dual Select in real-time, and digital cine replay • Multiple cursor sets on frozen and cine playback images
• Selectable split screen display formats in 2D/color with M • Up to eight distance measurements per screen
mode and/or spectral Doppler mode: top-bottom or side • Distance, depth from skin line
by-side in real-time and digital cine replay • Trace Length measurement
• Angle measurement
Beamforming in 2D Imaging • Area and circumference: ellipse, trace, cross, spline
• New generation digital beam former technology enables • Compound Measurements:
parallel and quad processing of the RF signal data in the - Volume: user-selectable calculated by 2-Plane
time and amplitude domains 3 distances, 2-Plane trace, 1 Plane 2 distances,
• Patented ASIC technology preserves signal integrity 1-Plane ellipse or 1-Plane disk measurements
through precision up-sampling for better beam definition - Flow volume: Combined velocity and distance,
• Configurable signal processing hardware provides a or velocity and ellipse measurements
pathway for future performance expansion and - Stenosis: user-selectable, calculated by area, or
technology innovations diameter measurements
• 2D-mode line density up to 322 lines
• Up to 768 Processing Channels Tissue Harmonic Imaging
• Total system dynamic range of > 160 dB
Tissue Harmonic Imaging with selectable
frequencies increases success with difficult-to-
Focusing
• Up to four transmit focal zones
image patients, improving diagnostic confidence
• Digital dynamic receive focusing with dynamic apodization and reducing noise and clutter in the image.
• SynAps™ aperture control for improved resolution at depth
• MultiHertz multiple frequency imaging capability in
Tissue Harmonic Imaging (THI) up to 6.8 MHz
2D Image Processing • Available for the P4-2 and 5.0P10 phased array
• Precision MotionCapture Technology results in superb
transducers and the C6-2 curved-linear array transducer
contrast and spatial resolution, higher frame rates, and
improved signal-to-noise ratio in the real-time image

3
ACUSON CV70 Cardiovascular System

PW Pulsed Wave Spectral Doppler Doppler Calipers – Generic Measurements


• Available on all imaging array transducers and Calculations
• Up to two user-selectable transmit frequencies • Multiple cursor sets on frozen and cine playback images
per transducer, frequency range is 2.1 to 7.0 MHz • Velocity/Frequency/Pressure Gradient
• 4 sweep speed selections: 2, 4, 8, 16 sec. • Heart rate/Heart cycle/Time
• 4 selectable pre-processing curves • Auto-Trace measurements and calculations including PS,
• 8 selectable post processing gray maps MD, TAVmax, PI, RI and S/D or VTI (cardiac)
• 4 user-selectable Doppler colorization maps • Resistive Index (RI)
(Sepia, Mag, Temp, Bow and Tan) • Pulsatility Index (PI), including Peak-to-Peak method
• Adjustable gain from 30 to 60 dB in one-decibel • Time Average Velocity max (TAV)
increments • Systolic/diastolic ratio (S/D)
• PRF range: 1,400 to 15,300 Hz • Velocity Time Integral (VTI)
• Velocity scale range: ±14.7 cm/sec to ±277.4 cm/sec (with • Acceleration/Deceleration
High PRF), up to 554.8 cm/sec in one direction at 0º angle • Flow volume using combined velocity and distance, or
correction velocity and ellipse measurements
• Angle correction 0 - 90º in one-degree increments • Doppler angle correction after measurement
• Auto angle correction 60/0/60º for vascular applications
• Gate size: from 0.4 up to 15.1 mm
• 7 wall filter selections, range 22 to 2,028 Hz proportional
Color Doppler Velocity Imaging
• Available on all imaging array transducers
to PRF – transducer dependent
• MultiBeam Formation technology provides Parallel and
• 9 levels of baseline shift
Quad Signal Processing for high color Doppler frame
• Spectral invert
rates – transducer dependent
• Auto-Doppler trace function with auto calculation and
• Advanced processing in Color mode resulting in excellent
display of PS, MD, TAVmax, PI, RI and S/D
spatial resolution and superior flash suppression
• Spectral Doppler Tissue Imaging (DTI)
• Up to two user-selectable transmit frequencies per
- Provides one button optimization for analysis of cardiac
transducer, frequency range is 2.1 to 7.0 MHz
tissue motion
• Up to 8 user-selectable color velocity maps (4 velocity; 4
velocity/variance)
CW Continuous Wave Spectral Doppler • Velocity scale range: 1.2 cm/sec to 229 cm/sec
• Steerable CW available on phased array transducers – transducer dependent
• Pencil style CW transducers at 2 and 5 MHz for cardiac and • Adjustable gain from 0 to 30 dB in one-decibel
vascular applications increments
• Up to two user-selectable transmit frequencies per • 5 Color line density selections
transducer • 4 Motion Cut selections proportional to velocity scale
• 4 sweep speed selections: 2, 4, 8, 16 sec. • 10 Noise Cut filter selections (spatial smoothing)
• 4 selectable pre-processing curves • 12 Tissue/color priority selections
• 8 selectable post processing gray maps • 8 Color persistence levels
• 4 user-selectable Doppler colorization maps • 5 Flow state selections per exam type for quick
(Sepia, Mag, Temp, Bow and Tan) adjustment of color flow depending on pathology
• Adjustable gain from 30 to 60 dB in one-decibel • Color invert
increments
• Adjustable gain from 30 to 60 dB in one-decibel
increments
Power Doppler Imaging
• PRF scale range: 4.0 to 47.6 kHz Directional Power Doppler Imaging
• Velocity range: ±0.7 m/sec to ±8.5 m/sec, up to 17.0 m/sec • Available on all vascular transducers
in one direction • Parallel Processing – transducer dependent
• 7 wall filter selections, range 68 to 6,333 Hz – proportional • Up to two user-selectable transmit frequencies per
to PRF – transducer dependent transducer, frequency range is 2.1 to 7.0 MHz
• Nine levels of baseline shift • Selection of 6 Power Doppler maps
• Spectral invert • Selection of 4 Directional Power Doppler maps
• PRF scale range: 330 Hz to 12,550 Hz – transducer
dependent
Spectral Doppler Display • Gain: 0 to 30 dB in one-decibel increments
• Full screen D trace, 2D/Doppler mode, triplex or update
• 5 Color line density selections
2D/C/Doppler, 2D/C/Doppler/M-mode
• 4 Motion Cut selections proportional to PRF scale
• Three imaging display formats – top-bottom: 1/3 – 2/3, 1/2
• 10 Noise Cut filter selections
1/2; side-by-side: 40-60
• 12 Tissue/color priority selections
• 8 Color persistence levels
• 5 Flash suppression levels

4
ACUSON CV70 Cardiovascular System

• 5 Flow state selections per exam type for quick adjustment • Cine Store: Multiple single frame storage with clipboard
of color flow depending on pathology review allowing post processing, measurement and
annotation functions
Color and Power Doppler Display Post Processing Features in Freeze Frame or Cine
• 2D/C mode, Split 2D-2D/C mode, Dual Select 2D/C mode
• 2D-mode
• 2D/C/D mode (simultaneous triplex), 2D/C/D mode
- Zoom/pan
(update)
- Gray map
• 2D/C/M mode simultaneous
- 2D-mode B-color maps
- Measurements/reports/annotations/pictograms
M-Mode
• Available on all imaging array transducers • Color
• Up to five user-selectable transmit frequencies, including - Zoom/pan
fundamental and harmonics - Color map
• 4 Edge Enhancement selections - Color invert
• Display dynamic range: 35 to 70 dB in one decibel - Measurements/reports/annotations/pictograms
increments
• Adjustable gain from 0 to 40 dB in one-decibel increments • Doppler
• 6 user-selectable gray maps - Gray map
• 4 user-selectable M-mode colorization maps (Sepia, Mag, - Doppler B-color maps
Temp, Bow and Tan) - Angle correct
• 4 sweep speed selections: 2, 4, 8, 16 sec. - Measurements/reports/annotations/pictograms

M-Mode Image Display • M-mode


• Full screen M-mode, 2D/M-mode, 2D/C/M-mode, - Gray map
2D/Doppler/M-mode, 2D/C/Doppler/M-mode - M-mode B-color maps
• Three imaging display formats – top-bottom: 1/3 – 2/3, - Measurements/reports/annotations/pictograms
1/2 – 1/2; side-by-side: 40 – 60

M-Mode Calipers – Generic Measurements TRANSDUCER TECHNOLOGY


and Calculations
• Multiple cursor sets on frozen and cine playback images Ultra-sensitive, wideband transducers,
• Distance matched with user-selectable MultiHertz
• Time imaging, improve resolution and penetration.
• Ratio Depending on the transducer, the user can
• Heart rate/heart cycle
select up to five 2D and THI frequencies and
• Slope
• Compound Measurements: two color and spectral Doppler frequencies,
- Flow volume: Combined velocity and distance, or expanding the clinical versatility of a single
velocity and ellipse measurements transducer, and thereby maximizing
transducer investment.

FREEZE, CINE AND CINE • Wideband MultiHertz imaging allows two separate
POST-PROCESSING FUNCTIONS Harmonic frequencies user selection of 2D
and color frequency for optimal resolution and
penetration
Cine Review • microCase™ transducer miniaturization technology
Cine feature offers post-acquisition optimization combined with SuppleFlex™ transducer cables provide
of all real-time post-processing functions. small, lightweight, comfortable transducers, designed
• Frame-by-frame cine loop review and continuous cine to help reduce operator fatigue during prolonged
motion review, including control of playback rate scanning sessions
• Independent cine review in mixed modes (2D/M, • Innovative ultra low-loss lens materials and
2D/Doppler, 2D/C/Doppler) microelectronic technologies for efficient performance
• Independent cine review in 2D Dual Select mode with and increased signal bandwidth
image align playback feature • Frequency range: 2.0 – 13.0 MHz
• Standard Cine Memory: providing up to 511 2D mode
images or up to 511 2D/C images Note: See dedicated transducer cards for more information.
• Up to 60 seconds Doppler Cine, or up to 60 seconds M
mode Cine

5
ACUSON CV70 Cardiovascular System

• OR Monitor output for display of images


APPLICATIONS • Speciality access Intraoperative transducer for epiaortic
Imaging
The CV70 system is designed to support cardiac
and vascular imaging applications. Factory Cardiac
supplied exam and transducer dependent • Adult and pediatric standard measurements and
imaging presets have been carefully optimized calculations including LA volume, diastolic function
for each application to provide consistency, and Qp/Qs shunt
• Volume formulas for left atrial volume and Left
reliability, and increased productivity. Selected
Ventricular function assessment in 2D-mode and
applications, text annotation labels, worksheets M-mode
and reports. • 2D-mode, M-mode, and Doppler calculations
• M-Mode Slope, Heart Rate, Time, and Distance
• Cardiac measurements
- Adult, Pediatric and Fetal echocardiograms • Doppler Acceleration, Deceleration, Trace, Heart Rate,
• Vascular (Carotid, Brachial artery Imaging, Peripheral and Time and Velocity measurements
Venous exams) • Cardiac patient report and worksheet for 2D
• Surgery: TEE Monitoring, special access imaging mode, M-mode, and Doppler
• TCD vascular
• Surgery
• Abdominal Vascular DIGITAL PATIENT STUDY
STORAGE AND ARCHIVING

EXAM-SPECIFIC MEASUREMENTS The DIMAQ integrated workstation allows


AND CALCULATIONS for digital acquisition, storage and review of
complete ultrasound studies, including static
images and dynamic clips as well as
The measurement function is arranged by exam measurements, calculations and reports.
type and is available for use with all exams
Embedded DICOM (option) allows for easy
types. The ultrasound system has measurement
integration of the system into departmental or
and report packages for the following exam hospital-wide PACS.
types:
Patient Study Management
Cardiac Replay of digitally stored images and clips in a
• All general measurements and calculations
selectable 1-up, 4-up, 9-up or 16-up screen format.
The patient study screen allows for study selection,
Vascular search, and deletion or for export to CD-R.
• All general measurements and calculations
• Internal 40 GB hard drive for patient data management
• CD-RW drive for 650 MB CD-R provides patient study
Peripheral Vascular Option archiving
Carotid Artery Imaging • Hard drive capacity:
Brachial Artery Imaging - approximately 42,000 b/w or color images or
approximately 6,300 dynamic clips (2 sec. Color clip)
Imaging capabilities for the physician to display
• Digital storage of static images and dynamic
and measure Intimal medial thickness and brachial clips:
reactivity to assess endothelial function. - JPEG lossy compression of dynamic clips with user
• All general measurements and calculations selectable compression level
• Right and left extremity measurements • Retrospective clip capture during real-time imaging
• Peripheral vascular patient report with a selectable duration of 1, 2, 3, or 4 seconds
or a selectable duration 1, 2, 3 or 4 beat capture;
Transcranial 2D/Color/Power/PWD ECG triggerable
Doppler for vascular studies • Prospective clip capture during real-time imaging with
• All general measurements and calculations a selectable duration of 1 to 120 seconds a selectable
duration 1 to 120 beat capture; ECG triggerable
• Editable clip capture from Cine replay
Intraoperative Option
• Storage and retrieval of real-time dynamic clips
• Special System configuration for the OR
• Storage and retrieval of frozen static images

6
ACUSON CV70 Cardiovascular System

• Storage and retrieval of reports DICOM 3.0 Connectivity (Option)


• Instant dial-in replay of dynamic clips or static images in 1
Provides digital image transfer via a DICOM
up screen format
• Perform Measurements and Calculations on current, as network for both printing and storage. The
well as on saved and retrieved images and clips CV70 system acts as a DICOM Storage Class
• Export of patient studies from Hard Drive to CD RW Drive User and DICOM Print and store Class User and
• Exported images and clips in standard DICOM (option), TIF can be connected to a DICOM color or grayscale
and AVI file formats Printer and/or to DICOM workstation and
• M-mode Still Frame Scroll and Store
archive devices.
• CW and PW Spectral Doppler Still Frame Scroll and Store
• Patient database sorting by Name, ID, Study Date and
Exam type DICOM Storage Class
• Allows connectivity to PACS
• Allows storage of all digital images and dynamic clips
Network Export with patient demographic data
• Provides a gateway to selected workstations for patient file
reviews
• Can send images, clips, reports, and stress-echo exams to DICOM Print Class
an appropriate workstation for review and diagnosis • Allows printing to DICOM print device
• Transfer is password protected to help support the user’s
compliance with HIPAA regulations DICOM Storage Commitment Class
• Can provide access to advanced workstation features such • Allows the system to recognize "storage commitment"
as structured reporting messages from suitably-equipped PACS systems
• Helps prevent accidental loss of image data in case of
PACS system errors
OPTIONS
Stress Echo Imaging (Option) DICOM Modality Worklist (Option)
• Allows automatic import of patient scheduling and
The stress echo package provides tools for
demographics from a DICOM server
ECG-triggered acquisition, display, selection
comparison, evaluation and archiving of DICOM Modality Performed Procedure
multiple cardiac loops during various stages of
Step-MPPS (Option)
a stress echo examination. The software module • Allows the ultrasound systems to automatically
is based on Microsoft Windows® 2000 standards. exchange ‘Performed Procedure Step’ information
• Standard acquisition protocols for treadmill, with the Hospital Information System (HIS) or Radiology
ergometric, and pharmacological stress with Information System (RIS)
- 2-Stage Exercise Stress Echo Protocol (Retrospective)
- 2-Stage Exercise Stress Echo Protocol (Prospective)
- 3-Stage Exercise Stress Echo Protocol (Retrospective) DOCUMENTATION DEVICES
- 3-Stage Exercise Stress Echo Protocol (Prospective)
- 6-Stage Pharmacological Stress Echo Protocol
Optional On-Board Video Devices
(Retrospective)
• Up to three documentation devices can be integrated
• Full screen or ROI (region of interest) acquisition
and controlled through the control panel
• Easy workflow throughout the exam protocol
• Supported devices:
• Stage Timer
- Mitsubishi P93W-S B&W Printer (standard equipped)
• Prospective Continuous Capture or Retrospective
- Mitsubishi HS-MD 3000 E/U VCR
labeled capture
- Mitsubishi CP-900 Color Printer
• LVO with contrast capture within Stress echo protocol
• Reference image display during acquisition
• Immediate review of acquired loops SYSTEM INPUT/OUTPUT
• Flexibility to skip views or stages
• Flexibility to re-acquire and overwrite already acquired Video Standard
images • PAL/CCIR: 625 lines, 50 Hz
• Indication of current view, acquired views and skipped • NTSC/EIA: 525 lines, 60 Hz
views in the workflow diagram
• Wall Motion Scoring, 17-segment model with graphical
display and report printing
Video/Audio Input
• 1 Composite color Video in, BNC-type
• LV Volume Measurements with report printing
• 1 Y/C Video in, S-terminal (SVHS)
• Ability for customized studies through Protocol Editor, with
• 1 2-Channel Audio in (Right/Left), phone jack type
up to 12 stages, 6 views per stage, 20 loops per view

7
ACUSON CV70 Cardiovascular System

Video/Audio Output Quality Standards


• 1 Composite B/W Video out, BNC-type FDA QSR 21 CFR Part 820
• 1 Composite color Video out, BNC-type ISO 9001:94
• 2 RGB & Composite Sync out, mini D-SUB (15 pin) ISO 13485
• 2 Y/C Video out, S-terminal (SVHS) EN 46001:96
• 1 2-Channel Audio (Right/Left), phone jack-type
Design Standards
Other Input/Output UL 2601-1
• 1 ECG lead connector, AIUM/NEMA standard CSA C22.2 No. 601-1
• 1 ECG DC In connector, phone jack-type EN 60601-1 and IEC 60601-1
• 1 Foot switch connector, phone jack-type EN 60601-1-1 and IEC 60601-1-1
• 2 Remote control connector, mini jack (stereo) EN 60601-1-2 and IEC 60601-1-2
EN 60601-2-25 and IEC 60601-2-25
System Connections EN 60601-2-37 and IEC 60601-2-37
• Network
- 1 Ethernet connector, type RJ45 (10/100BaseT) Acoustic Output Standards
• Peripherals • IEC 61157 (Declaration of Acoustic Power)
- 2 Serial port RS232-C connector, D-SUB (9-pin) 1 USB • AIUM/NEMA UD-2, 1998 Acoustic Output Measurement
port, Series A-type Standard for Diagnostic Ultrasound
• AIUM/NEMA UD-3, 1998 Standard for Real-Time Display
SYSTEM DIMENSIONS of Thermal and Mechanical Acoustic Output Indices on
Diagnostic Ultrasound Equipment
• System Height: 142.2 cm (56.0 inch)
• Width: 51.0 cm (20.1 inch) CE Declaration
• Depth: 79.8 cm (31.4 inch) This product is provided with a CE marking in accordance
• Weight: 130 kg (286 pounds) without OEM’s with the regulations stated in Council
Directive 93/42/EEC of June 14, 1993
concerning Medical Devices. Siemens
ELECTRICAL/ENVIRONMENTAL Medical Solutions USA, Inc., is
SPECIFICATIONS certified by notified body 0123 to
Annex 11.3 – Full Quality System.

• Power connections: Authorized EC Representative:


- 100V version: 90 – 110 VAC, 50/60 Hz (Japan)
Siemens Aktiengesellschaft
- 115V version: 98 – 132 VAC, 50/60 Hz
Medical Solutions
- 230V version: 196 – 264 VAC, 50/60 Hz
Henkestrasse 127
• Built-in AC isolation transformer
D-91052 Erlangen
• Power consumption: maximum 1050 VA with OEM’s
• Atmospheric pressure range: 700 hPa to 1060 hPa (525 to Acuson and MulitHertz are registered trademarks and
795 mm Hg) or up to 3050 m (10,000 ft) CV70, QuickSet, SynAps, microCase, SuppleFlex and Axius
• Ambient temperature range (without OEM’s): +10°C to are trademarks of Siemens AG. Microsoft and Windows are
+40°C (50° to 104°F) registered trademarks of the Microsoft Corporation.
• Humidity: 30 – 85%, non-condensing, during operation
• Maximum heat output: 3600 BTU/hr Siemens reserves the right to modify the design and
specifications contained herein without prior notice.
Please contact your local Siemens Medical Solutions
STANDARDS COMPLIANCE Sales Representative for the most current information.
The CV70 platform meets the requirements of *The Axius edge-assisted Ejection Fraction and
the Medical Device Directive and carries the CE advanced quantification and cardiac calculation
Mark. features require 510(k) review and are not yet
commercially available.

8
ACUSON CV70 Cardiovascular System

Siemens AG Medical Solutions Siemens Medical Solutions USA, Inc. Siemens Medical Solutions USA, Inc. A91004-M2410-A672-2-4A00
Henkestrasse 127 Ultrasound Division Headquarters Ultrasound Division DB 0604
D-91052 Erlangen PO Box 7393 P.O. Box 7002
Germany Mountain View, CA 94039-7393 USA Issaquah, WA 98027-7002 USA © 2004 Siemens Medical
Telephone: + 49 09131 84-0 Telephone: 1-800-228-4128 Telephone: 1-800-367-3569 Solutions USA, Inc.
From outside the USA: 1-650-969-9112 From outside the USA: 1-425-557-8704
www.siemensmedical.com/ultrasound
Europe: + 44 20 8479 7950
Asia Pacific: +65 6341 0990
Latin America: +1 786-845-0697

You might also like