0% found this document useful (0 votes)
10 views

Column Layout

E1-E18 represent columns around the perimeter and in the interior of a structure. The columns have various dimensions ranging from 150mm to 9900mm. Notes indicate that all dimensions are in millimeters, levels are in meters, and the drawing is not to scale as only written dimensions should be followed.

Uploaded by

DINESH M.N
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
10 views

Column Layout

E1-E18 represent columns around the perimeter and in the interior of a structure. The columns have various dimensions ranging from 150mm to 9900mm. Notes indicate that all dimensions are in millimeters, levels are in meters, and the drawing is not to scale as only written dimensions should be followed.

Uploaded by

DINESH M.N
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

E7 E15 E14

N
E1 E2 E3 E18 E17 E4 E5 E6 E16 E8 E9 E10 E11 E12 E13
86300
85800
3010 2660 1200 2420
2580 2200 3450
1020 1850
9900 9900 4230 9900 9830 25104500
3840 7250 6600 Notes:
RAFT LINE RAFT LINE RAFT LINE RAFT LINE
33002200 1.All dimensions are in millimeters and levels
are in meters unless otherwise specified.
AIR CONCOURSE COLUMN AIR CONCOURSE COLUMN
2.Drawing shall not be scaled, only written
500 3000 300 600 3000 330 375
450 300 225 375 150
S1 dimensions to be followed.
150

150

150

150

150

150

150

150

150

150

150

150
400

1000

900
1147
1200

1200

1200

1200

1200

1200

1200

1200

1200
2500 2500
SW1 SW1 C2 C2 C2 C2 3.Any Error or Discrepancies in the
300 C8 900C3 575 C8 750 750 750 C1
C3 C3 C3 C2 375 750
Drawings are to be brought to the notice.
6900

1200 750

RAFT LINE
1000 900
of the Architect/ Engineers.
4. This drawings shall not be used other than
1000 1200
750 C6 1200 900 750 450 375 1000 600 150
the purpose marked/issued specified.
1000 330
C2 C2 5. The drawings to be read with conjuction
S2
750

750

750
1200

1200

1200

1200

1200

1200

1200

1200

1200

1200

450
C6 C12

900
750

C1
450

450

450

450

450

450

450
C2 C2 with structural drawings.
3918 4350

300 300 500 300 325 330 300 C9 500 300


C7 C5 C11 1200
750 80 2350
SW9 6. All the drawings prepared by Design

2950
SW10 and structural consultants are as per
27500

300 2200
S.W3
80 2050
S7
1881 549

NBC norms and guidelines.

300

250
S.W2
2430

LIFT
S.W2

CUTOUT SW9 2430 REMOVAL OF FORMWORK(SHUTTERING) :


1632

300 Shuttering of any part of the structure shall not be


S8
300
removed until the concrete attains 70% of the specified
550 420 strength of concrete however the following minimum
RAFT LINE

RAFT LINE
600 300
750 450
C1 C1 C10
375
450 230 500
period (after final pour ) shall be allowed before
900 C4
1050

1200

1200
S3

750
removal of shuttering as per clause 11.3.1, is 456:2000

1200

1200
450

450

450

450

450

450

450
C6

600
900

900
1200

1200

1200

1200

1200
150
450

450
C2

750
750 900

2000
230
600 1000 C10 C1 C2 A. Vertical side of shuttering of columns,walls & beams

2400
300
C2 C9 C11 600 750 1000 750
1000 - 24 hours
S.W5 S.W8 SW11
32906900

1200
2660 450
B. Bottom shuttering of slabs (keeping the props)
450 1850 880
- 3 days
2660 450 450 1850 810 C. Bottom shuttering of beams (keeping the props)
1000 750 SW6 S.W4
1000 S.W7 SW11 600 - 7 day
300 375 330
C8 C8 D. Props to slabs :
2550

2550
SW1 1200 C4 260 271 C13
1850

1850
1200
2000

600
250

2500
C2 2500 C1

1050
C1 i .spanning upto 4.5 m - 7 days
1200

1200

1200

1200
S4

1000
820
900

900
750

750

C2 230 C2 C2
150

150

150

150

150

150

170

185
3000 600 450 750
100 SW1 3000
150
1200
i i .spanning over 4.5 m - 14 days
RAFT LINE RAFT LINE RAFT LINE RAFT LINE E. Props to beams & arches :
150

300
150

150
i .spanning upto 6 m - 14 days
i i.spanning over 6 m - 21 days
S5 PCC LINE Ca Ca Ca Ca Ca Ca Ca Ca
LAP JOINTS FOR REINFORCEMENT BARS :
1. At any cross section of the member,not more than
50% of the bars shall be lapped.
2. Laps shall be staggered with a minimum centre to
11105

centre distance of 1.3 times lap length of the bar for


tension & compression members.
3. Development length (ld) shall be as per (sp:34-1999)
table below:
a) Development length for column bars - 40d
b) Development length for beam bars - 50d
4. Laps in columns shall be provided at mid height of
floor and not at slab level .
Ca Ca Ca Ca Ca Ca Ca Ca 5. Laps in beams and slabs shall be provided at the
S6 point of contraflexure.
250

250
6. Welding of bars shall be done as a stitch weld for 5
times diameter of bar and a gap of 5 times higher
diameter bar and again welding for another 5 times
SI. COLUMN COLUMN
NO NAME SIZE NO'S diameter of bar using arc welding and special
electrodes after obtaining prior written approval from
6766 8320 8320 8320 8320 8320 8320 8329 5235 01 C1 600 X 900 07
the structural designer.
SI. SHAER WALL SHAER WALL NO'S 7. Detailing of rebars shall confirm to sp-34 & is 13920.
02 C2 750 X 1200 16 NO NAME SIZE GENERAL NOTES:
E1 E1a E2a E18a E4a E5a E6a E16a E10a E11 03 C3 900 X 1200 04
1. Concrete grade shall be M35(design mix) confirming to
01 SW1 300 X 3000 04 is 456:2000
04 C4 750 X 1200 02 2. Minimum cement content = 380 kg/m3.
IMPORTANT NOTES : 02 SW2, SW3 REFER LAYOUT 01
3. Min.grade of reinforcement marked thus (y) shall be Fe
05 C5 1200 X 1200 01 03 SW4 REFER LAYOUT 01 550D confirming to IS 1786-1985
* GRADE OF CONCRETE - M35 ( DESIGN MIX ) LAYOUT OF COLUMN 06 C6 1000 X 1200 03 04 SW5 300 X 3000 01
4. Clear cover for reinforcement
a) Column = 40mm d) Raft slab bottom = 75mm
07 C7 1000 X 1200 01 05 SW6 300 X 2000 01 b) R.C wall = 40mm e) Raft slab top = 50mm
COLUMN SCHEDULE : STUB COLUMN SCHEDULE : 08 C8 1000 X 1200 04 06 SW7 REFER LAYOUT 01
c) Shear wall = 40mm
This drg. read in conjection with arch.drgs.
NOTE:
IMPORTANT POINT: 09 C9 1200 X 1200 02 07 SW8 REFER LAYOUT 01 5. Raft & Columns are designed for Ground + Mezzanine +
FOR L.S & R.C DETAILS OF COLUMN
SI. COLUMN COLUMN NO'S SI. COLUMN COLUMN NO'S Four floor loads only.
NO NAME SIZE NO NAME SIZE 10 C10 1000 X 1200 02 08 SW9, SW10 REFER LAYOUT 01
REFER DRWG NO : GC/STRD-D010,D011 A) IN R.C WALL - WATER STOPPER TO BE USED AT JOINTS. 6. SBC of the soil is taken as 320kN / sqm. @ 2.40m below
B) PROVIDE MEMBRANE WATER PROOFING FOR BASEMENT 11 C11 900 X 1200 02 09 SW11 300 X 2000 02 from N.G.L. as per soil report.
FOR R.C DETAILS OF SHEAR WALL 01 Ca Ø450 14 01 Ca 450 X 450 14
REFER DRWG NO : GC/STRD-D013 RAFT & R.C. WALL. 7. Spacer bar - 25mm dia to be provided in between two
12 C12 600 X 1200 01 layer of reinforcement at every 750mm c/c
C) MIX INTEGRAL WATER PROOFING COMPOUND CRYSTALINE
FOR CORRECT LEVELS & DIMENSIONS WHILE MIXING OF CONCRETE. 13 C13 Ø 1000 01 8. Structural engineer responsibility is limited to design &
REFER ARCHI DRWG issual of structural drawing only
TOTAL 46 9. Onus of construction lies with contractor/owner
10. For concreting water cement ratio should be (0.45) (for
1bag cement= max-25 lit of water only to be added.)
NOTES STRUCTURAL DESIGN QUALITY ASSURANCE
REVISIONS
Notice of no objection from Southern Railways Katpadi is being accorded for design principles based on the The drawing has been prepared based on actual site survey and other terms and conditions of the EPC Agreement. Responsibility of accuracy, correctness , This drawing including its design and detailing has been checked in accordance with the requirements of EPC Agreement and found
recommendations of the Architect/Lead Designer and proposal by the Contractor. However, the completeness, integrity and full compliance with byelaws, standards, statutory, regulations of relevant Codes & Manuals/ Rules and as per EPC Agreement suitable for the execution purpose. The overall responsibility of correctness of design,detailing and compliance with EPC agreement R.NO DATE DESCRIPTION
overall responsibility and design accuracy lies with the contractor (Engineering Projects (india) Pvt Ltd) provisions, rests with the Design Consultants and the Contractor without any financial implications. rests with the Structural Design Consultant and Contractor.
CLIENT: PROJECT: EPC Contractor: DESIGN CONSULTANT Authority Engineer (PMS) AXEN CN/MAS DY. CE CN/MAS CE CN/MAS
Drawing Title :
SOUTHERN RAILWAYS, REDEVELOPMENT OF ENGINEERING PROJECTS M/S VOYANTS SOLUTIONS PVT. LTD.
KATPADI. KATPADI JUNCTION (INDIA) LTD-CHENNAI Drawing Type :
Drawing No.: Scale: 1:100 Date: 12.12.23
Drawing Purpose: Sheet Size: A2 Rev. No: R0
AGM DESIGN DIRECTOR TEAM LEADER LEAD DESIGNER

You might also like