CYFGCS50LRSH
CYFGCS50LRSH
Features Applications
• High electrical isolation • Battery supplied applications
• High linearity, high accuracy • Uninterruptible power supplies (UPS)
• High reliability • Variable speed drives
• Good overload capability • Welding machine
• Small sizes • Electric power network monitoring
• Insulated plastic case recognized • AC frequency conversion servo-motors
according to UL94-V0 • Electrochemical applications
• Very good property-price ratio
Technical Data
Parameters Values Unit
CYFGCS CYFGCS CYFGCS CYFGCS CYFGCS CYFGCS
Part number
0.5LRSH 1LRSH 5LRSH 10LRSH 20LRSH 50LRSH
Rated input current IPN 0.5 1 5 10 20 50 A
Current measuring range IP 0~±1 0~±2 0~±10 0~±20 0~±40 0~±75 A
Rated output voltage 5±0.2% 5±0.2% 5±0.1% 5±0.1% 5±0.05% 5±0.05% V
Turns ratio KN 1:200 1:200 1:500 1:500 1:1000 1:1000
Supply voltage ±15(±5%) V
Current consumption At Vc=±15V 15 + IP/KN mA
Isolation voltage 2.5kV rms/50Hz/1min between primary and secondary circuits
Linearity <0.01 %FS
Zero offset voltage TA=25℃ <±5 mV
Thermal Drift of Offset
Voltage VP=0,TA=-25~+85℃ <±0.01(≤1A±0.03) mV/℃
Application Note
1. Incorrect wiring may cause damage to the sensor. After the sensor is powered on, the
same-phase voltage value can be measured at the output when the measured current
passes through the sensor in the direction of the arrow.
2. The dynamic characteristics (di/dt and response time) are optimal when the input current
drain completely fills the primary current input perforation.
3. The temperature of the primary busbar or cable should not exceed 100°C.
4. The installation and use environment of the sensor should be free of conductive dust
and corrosive gases.
5. The sensor is a precision device, it should be lightly handled and put away when using
and avoid violent vibration or high temperature.