Alarm Management Functions (1)
Alarm Management enables network maintenance personnel to monitor and
manage alarms or events reported by the system or managed objects (MOs).
Alarm Management provides various monitoring and handling rules and
notifies O&M personnel of faults. In this way, network faults can be efficiently
monitored, quickly located, and handled, ensuring proper service running.
Page 4 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
Alarm Management Functions (2)
⚫ Alarm management includes setting alarm rules, monitoring alarms, and handling
alarms. 1. Setting alarm rules: Based on experience in alarm handling,
configure alarms to aggregate alarms to improve O&M
efficiency.
For example: During the commissioning, a large number of
repeated alarms may be generated to interfere with O&M.
These alarms can be masked during the commissioning.
2. Monitoring and viewing alarms: Administrators can
perform routine monitoring on the managed objects such as
devices and NEs to detect faults and view alarms in time.
3. Handling alarms: O&M personnel can locate and handle
alarms to restore the device or service.
4. Performance optimization and auditing: Based on the
analysis of information about handling historical alarms, you
can formulate optimization solutions and audit the alarms to
determine whether they are correctly masked.
Page 5 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
Contents
1. Alarm Management Functions
Page 6 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
Introduction to the Alarm Interface (1)
⚫ Area 1: Alarm filtering panel. You can expand the panel and set filter criteria to
view alarms.
⚫ Area 2: Alarm operation bar. You can perform operations on alarms in batches.
⚫ Area 3: Quick filter template. You can save common filter criteria as templates for
quick use.
⚫ Area 6: Intelligent panel. You can obtain help information about the current page,
such as tasks, documents, and FAQs.
Page 7 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
Introduction to the Alarm Interface (1)
3 Save common filter
criteria as templates
for quick use.
Perform operations on 4
alarms in batches.
5
Specify parameters
for filtering
Set parameters
View the help page displayed on the
for alarm handling alarm details page
Page 9 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
Contents
1. Alarm Management Functions
Page 10 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
Monitoring and Viewing Alarms (1)
O&M personnel can monitor alarms and view alarms/events to understand
alarm/event details to response in time.
⚫ Procedure
Open the Network Management app and choose Monitor > Alarm > Current Alarms
from the main menu. Alternatively, open the Alarm Management app and choose Current
Alarms from the main menu.
Monitoring alarms
▪ You can view the number of alarms of four severities through the alarm indicator. You
can click an indicator to quickly filter out the alarms of this severity.
▪ You can view alarms in the alarm list.
Querying alarms
▪ You can expand the filter criteria area to query alarms.
▪ Set filter criteria and click Filter to search for alarms.
▪ Export current alarms to the local host for query.
Page 11 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
Set filter criteria and click View the number of alarms of four
Filter to search for alarms. severities through the alarm indicators.
Export current
alarms to the local
host for query.
Page 12 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
Contents
1. Alarm Management Functions
Page 13 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
Handling Alarms (1)
O&M personnel can handle alarms to facilitate troubleshooting. For example,
perform operations of acknowledging and clearing alarms.
⚫ Procedure
Open the Network Management app and choose Monitor > Alarm > Current Alarms from the main menu.
Alternatively, open the Alarm Management app and choose Current Alarms from the main menu.
View the alarm details.
Obtain key alarm information, including alarm names, handling suggestions, and location information, to
facilitate fault diagnosis and troubleshooting for network maintenance personnel.
Page 14 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
Handling Alarms (2)
Page 15 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
Handling Alarms (3)
⚫ Procedure
Manually acknowledge alarms.
◼ Select one or more alarms and click Acknowledge above the alarm list. The acknowledged alarm indicates that the
alarm has been handled by someone, and others do not need to pay attention to it.
Page 16 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
Contents
1. Alarm Management Functions
Page 17 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
4.2 Analyzing Historical Alarms (1)
By analyzing historical alarms, you can identify potential system problems and
handle these problems in time to prevent faults and ensure the normal running of
the system.
⚫ Procedure
Open the Network Management app and choose Monitor > Alarm > History Alarms from the main menu.
Alternatively, open the Alarm Management app and choose History Alarms from the main menu.
Query historical alarms
◼ For example, for the history alarms of the past week, set Occurred to the Past 7 days in the alarm filtering area. Click Filter.
Page 19 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
Contents
1. Alarm Management Functions
Page 20 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
Comparison of Alarm Rules Between NCE
and U2000 (1)
The following table lists the alarm rules supported by NCE and U2000.
Supported by
Rule Name Supported by U2000 Difference
NCE
• U2000 allows users to download remote
notification logs and collect statistics on
Setting Remote Notification Rules Yes Yes remote notification logs.
• NCE supports the import and export of
remote notification rules.
Configuring Aggregation Rules No Yes • None
• The rule name on U2000 is Transient
Alarm/Repeat Event Analysis Rule and
Configuring Rules for Handling
Yes Yes Alarm/Event Frequency Analysis Rule.
Intermittent/Toggling Alarms
• NCE does not support repeat
event/frequency analysis rules.
Synchronizing Alarms Yes Yes None
Setting Auto Acknowledgement Rules Yes Yes None
Alarm maintenance experience Yes Yes None
Configuring Severity and Type
Yes Yes NCE does not support event redefinition rules.
Redefinition Rules
Page 21 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
Comparison of Alarm Rules Between NCE
and U2000 (2)
The following table lists the alarm rules supported by NCE and U2000.
Supported by
Rule Name Supported by NCE Difference
U2000
Configuring Correlation Rules Yes Yes None
Setting Events as ADMC Alarms Yes Yes None
NCE does not support the setting of
Configuring Northbound Filtering Rules Yes Yes
event northbound filtering rules.
Configuring Alarm/Event Suppression Rules Yes No NCE does not support this function.
Configuring Alarm/Event Postprocessing Rules Yes No NCE does not support this function.
Setting the Life Cycle for Current Alarms Yes No NCE does not support this function.
Page 22 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
Contents
5. Configuring Alarm Rules
5.7 Recording Alarm Handling Experience
5.1 Remote Notification
5.8 Configuring Severity and Type Redefinition
5.2 Configuring Aggregation Rules
Rules
5.3 Configuring Masking Rules
5.9 Configuring Name Redefinition Rules
5.4 Configuring Rules for Handling
5.10 Configuring Correlation Rules
Intermittent/Toggling Alarms
5.11 Setting Events as ADMC Alarms
5.5 Synchronizing Alarms
5.12 Configuring Northbound Filtering Rules
5.6 Setting Auto Acknowledgement Rules
Page 23 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
Contents
5. Configuring Alarm Rules
Page 24 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
5.1 Remote Notification
⚫ O&M personnel cannot browse alarms on the
Current Alarms page when they are out of office,
for example, during off-work hours or business
trips. Remote notification enables O&M personnel
to receive SMS or email notifications about alarms
so that they can handle alarms in real time.
⚫ Procedure
Before using the remote notification function, O&M personnel
need to set communication parameters for the SMS gateway,
SMN, or email server to enable the system to support remote
notification. The commissioning is complete, and the O&M
personnel test the interconnection.
Set notification parameters.
Send a notification: Automatic sending and manual sending.
Page 25 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
Contents
5. Configuring Alarm Rules
Page 26 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
5.1.1 Configuring Notification Templates
⚫ Remote notification requires standardized templates of emails and SMS.
Page 27 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
Contents
5. Configuring Alarm Rules
Page 28 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
5.1.2 Setting Remote Notification Rules (1)
⚫ O&M personnel cannot browse alarms on the Current Alarms page when they are
out of office, for example, during off-work hours or business trips. Remote
notification enables O&M personnel to receive SMS or email notifications about
alarms so that they can handle alarms in real time.
⚫ Procedure
Open the Network Management app and choose Monitor > Alarm > Alarm Settings from the main
menu. Alternatively, open the Alarm Monitor app and choose Alarm Settings from the main menu.
In the navigation pane, choose Notification Rules.
On the Aggregation Rules page, click Create, and set the parameters. When alarms meeting the rule
are reported, the system sends notifications to O&M personnel by email or SMS message.
▪ Filter: Filters the target alarms according to the filter criteria.
▪ Time Filter: Specifies the time range during which (for example, non-working time) remote notifications are
sent.
▪ Notification Type: The options are Email and SMS. You can set the time zone to meet the requirements of
remote scenarios.
▪ Recipient Groups: Sets the user who needs to receive the notification.
Click OK.
Page 29 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
5.1.2 Setting Remote Notification Rules (2)
Page 30 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
Contents
5. Configuring Alarm Rules
5.2 Configuring Aggregation Rules 5.8 Configuring Severity and Type Redefinition
Rules
5.3 Configuring Masking Rules
5.6 Setting Auto Acknowledgement Rules 5.12 Configuring Northbound Filtering Rules
Page 31 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
5.2 Configuring Aggregation Rules (1)
⚫ After an aggregation rule is set, the system automatically aggregates the repeated
alarms reported within the specified period into one alarm.
Procedure
▪ Open the Network Management app and choose Monitor > Alarm > Alarm Settings from the main
menu. Alternatively, open the Alarm Monitor app and choose Alarm Settings from the main menu.
▪ In the navigation tree, choose Aggregation Rules.
▪ On the Aggregation Rules page, click Create, and set the parameters. After the aggregation rule is
set, the repeated alarms reported within the specified period will be aggregated into one alarm.
▪ Click OK.
─ When monitoring or viewing alarms, you can filter out original alarms that are aggregated by selecting
Root/Aggregation alarms only and focus only on the alarms you need to handle.
Page 32 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
5.2 Configuring Aggregation Rules (2)
Aggregated alarm
Page 33 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
Contents
5. Configuring Alarm Rules
5.2 Configuring Aggregation Rules 5.8 Configuring Severity and Type Redefinition
Rules
5.3 Configuring Masking Rules
5.6 Setting Auto Acknowledgement Rules 5.11 Setting Events as ADMC Alarms
Page 34 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
5.3 Configuring Masking Rules (1)
⚫ You can set a masking rule to mask alarms or events that you are not concerned
about. The masked alarms or events will not be displayed in the alarm list or event
logs. Marking rules are classified into alarm masking rules and event masking rules.
⚫ Procedure
Open the Network Management app and choose Monitor > Alarm > Alarm Settings from the main menu.
Alternatively, open the Alarm Monitor app and choose Alarm Settings from the main menu.
In the navigation pane, choose Masking Rules.
On the Masking Rules page, click Create and select Alarm Masking Rules. The parameters are described
as follows:
1. Severity: Filters alarms by severity.
2. Alarm sources: Filters alarms by NE.
3. Advanced Conditions: Filters alarms based on the alarm ID, type, and status.
4. Time Filter: Specifies the time range to mask the reported alarms in the commissioning phase.
5. Masked alarms: Determines whether to display the masked alarms on the Masked Alarm page or discard them.
6. Priority: Defines the priorities for alarm masking rules.
Page 35 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
5.3 Configuring Masking Rules (2)
Filters alarms by severity.
Page 36 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
Contents
5. Configuring Alarm Rules
5.2 Configuring Aggregation Rules 5.8 Configuring Severity and Type Redefinition
Rules
5.3 Configuring Masking Rules
5.6 Setting Auto Acknowledgement Rules 5.11 Setting Events as ADMC Alarms
Page 37 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
5.4 Concepts of Intermittent and Toggling
Alarms (1)
Intermittent alarm: When the interval between alarm generation and alarm clearance is
less than a specific period, the alarm is considered as an intermittent alarm. The period is
called intermittent period. See Figure 1.
Toggling alarm: When the number of times that the same alarm (with the same alarm
source and same alarm ID) is alternatively generated and cleared exceeds a specified
value, the alarm is considered as a toggling alarm. See Figure 2.
Figure 1: Intermittent alarm Figure 2: Toggling alarm
Page 38 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
5.4 Configuring Rules for Handling
Intermittent/Toggling Alarms (2)
⚫ or discard intermittent or toggling alarms to reduce O&M interference caused by
massive repeated alarms.
⚫ Procedure
Open the Network Management app and choose Monitor > Alarm > Alarm Settings from the main
menu. Alternatively, open the Alarm Monitor app and choose Alarm Settings from the main menu.
In the navigation tree, choose Intermittent/Toggling Alarm Handling Rules.
On the Intermittent/Toggling Alarm Handling Rules page, click Create, and set the alarm rules.
▪ Conditions: Filters the target alarms according to the filter criteria.
▪ Time Filter: Specifies the time when a rule takes effect.
▪ Analysis Type: The options are Intermittent Analysis and Toggling Analysis.
▪ Intermittent Policy: Sets the period and number of times for defining an intermittent alarm. You can
determine whether to move alarms that meet the filter criteria to the Masked Alarms page,
Page 39 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
5.4 Configuring Rules for Handling
Intermittent/Toggling Alarms (3)
Filters the target alarms
according to the filter criteria.
Intermittent analysis
and toggling analysis
Page 40 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
Contents
5. Configuring Alarm Rules
5.2 Configuring Aggregation Rules 5.8 Configuring Severity and Type Redefinition
Rules
5.3 Configuring Masking Rules
5.6 Setting Auto Acknowledgement Rules 5.12 Configuring Northbound Filtering Rules
Page 41 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
5.4 Configuring Rules for Handling
Intermittent/Toggling Alarms (3)
⚫ After a peer system is disconnected from the current system, alarms of the peer
system cannot be reported to the current system. After the connection is restored,
the alarms need to be synchronized to the current system to facilitate monitoring.
⚫ Procedure
Open the Network Management app and choose Monitor
> Alarm > Alarm Settings from the main menu.
Alternatively, open the Alarm Monitor app and choose
Alarm Settings from the main menu.
In the navigation pane, choose Alarm Synchronization.
Click Custom alarm sources.
Select the NE where the alarm is generated and click OK.
Click the information you want to synchronize from the
list, and click Synchronize.
After the synchronization is complete, check whether the
alarm is reported on the alarm monitoring page.
Page 42 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
Contents
5. Configuring Alarm Rules
5.2 Configuring Aggregation Rules 5.8 Configuring Severity and Type Redefinition
Rules
5.3 Configuring Masking Rules
5.6 Setting Auto Acknowledgement Rules 5.12 Configuring Northbound Filtering Rules
Page 43 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
5.6 Setting Auto Acknowledgement Rules
⚫ When an auto acknowledgment rule is set, Alarm Management automatically
acknowledges the current alarms in the cleared status based on a specified rule and
converts them to historical alarms.
⚫ Procedure
Open the Network Management app and choose Monitor
> Alarm > Alarm Settings from the main menu.
Alternatively, open the Alarm Monitor app and choose
Alarm Settings from the main menu.
In the navigation pane, choose Auto Acknowledgement
Rules.
Select the auto acknowledgment rule required based on
the severity and click Enable or Delay settings.
▪ Enable: The system immediately acknowledges the alarms
that meet the rules.
▪ Delay settings: The system automatically acknowledges
the alarms whose clearance time exceeds the specified
days at daily basis. As shown in the figure on the right, at
01:00 every day, the system automatically acknowledges
alarms that are in the cleared state for more than six days.
Page 44 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
Contents
5. Configuring Alarm Rules
5.2 Configuring Aggregation Rules 5.8 Configuring Severity and Type Redefinition
Rules
5.3 Configuring Masking Rules
5.6 Setting Auto Acknowledgement Rules 5.12 Configuring Northbound Filtering Rules
Page 45 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
5.7 Recording Alarm Handling Experience
⚫ After handling an alarm, record the handling experience to the handling experience
database for future reference or guidance.
⚫ Procedure
Enter the alarm
Open the Network Management app and handling experience.
choose Monitor > Alarm > Alarm Settings
from the main menu. Alternatively, open the
Alarm Monitor app and choose Alarm
Settings from the main menu.
In the navigation pane, choose Experience.
On the Experience page, click Create, and
specify an alarm.
◼ Alarm name: Select the target alarm. View or edit the alarm
handling experience in
◼ Experience: Enter the alarm handling the alarm list.
experience information.
On the Current Alarms page, view or edit the
handling experience in the alarm list.
Page 46 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
Contents
5. Configuring Alarm Rules
5.2 Configuring Aggregation Rules 5.8 Configuring Severity and Type Redefinition
Rules
5.3 Configuring Masking Rules
5.6 Setting Auto Acknowledgement Rules 5.12 Configuring Northbound Filtering Rules
Page 47 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
5.8 Configuring Severity and Type
Redefinition Rules (1)
⚫ You can redefine severities and types of alarms. For example, if an alarm is
considered important, it can be set as a high-level alarm so that O&M personnel will
give priority to it.
⚫ Procedure
Open the Network Management app and choose Monitor > Alarm > Alarm Settings from the main
menu. Alternatively, open the Alarm Monitor app and choose Alarm Settings from the main menu.
In the navigation pane, choose Redefinition Rules > Severity and Type Redefinition.
On the Severity and Type Redefinition page, click Create, and specify the target alarm.
▪ Alarms and Alarm sources: After the redefinition rule is set, the system redefines the alarms
reported from the alarm sources.
▪ Action: Sets the redefined alarm severity and type.
▪ Filter: Filters alarms based on the alarm parameters.
▪ Time Filter: Sets the time when the rule takes effect.
Click OK.
Page 48 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
5.8 Configuring Severity and Type
Redefinition Rules (2)
After the redefinition rule is set, the system
redefines the alarms reported from the
alarm sources.
Page 49 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
Contents
5. Configuring Alarm Rules
5.2 Configuring Aggregation Rules 5.8 Configuring Severity and Type Redefinition
Rules
5.3 Configuring Masking Rules
5.6 Setting Auto Acknowledgement Rules 5.12 Configuring Northbound Filtering Rules
Page 50 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
5.9 Configuring Name Redefinition Rules
⚫ If some alarm names are technical and difficult to understand, you can redefine
alarm names as required by setting name redefinition rules.
⚫ Procedure
Open the Network Management app and choose
Monitor > Alarm > Alarm Settings from the main
menu. Alternatively, open the Alarm Monitor app and
choose Alarm Settings from the main menu.
In the navigation pane, choose Redefinition Rules >
Specifies the name
Name Redefinition. whose name will be
On the Name Redefinition page, click Create, and redefined.
specify the target alarm.
▪ Alarm: Specifies the name of an alarm whose name
will be redefined.
▪ New alarm: New name of the alarm.
Click OK. Sets the new name of
the alarm.
Page 51 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
Contents
5. Configuring Alarm Rules
5.2 Configuring Aggregation Rules 5.8 Configuring Severity and Type Redefinition
Rules
5.3 Configuring Masking Rules
5.6 Setting Auto Acknowledgement Rules 5.12 Configuring Northbound Filtering Rules
Page 52 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
5.10 Configuring Correlation Rules (1)
⚫ A correlation rule determines the root alarms and correlative alarms. When O&M
personnel monitor or view alarms, they can set a correlation rule to filter out
correlative alarms and focus only on root alarms.
⚫ Procedure
Open the Network Management app and choose Monitor > Alarm > Alarm Settings from the
main menu. Alternatively, open the Alarm Monitor app and choose Alarm Settings from the
main menu.
In the navigation pane, choose Correlation Rules.
On the Correlation Rules page, click the Custom tab and then click Create.
Set the parameters for correlation rule.
Click OK.
Page 53 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
5.10 Configuring Correlation Rules (2)
Page 54 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
Contents
5. Configuring Alarm Rules
5.2 Configuring Aggregation Rules 5.8 Configuring Severity and Type Redefinition
Rules
5.3 Configuring Masking Rules
5.6 Setting Auto Acknowledgement Rules 5.12 Configuring Northbound Filtering Rules
Page 55 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
5.11 Setting Events as ADMC Alarms
⚫ A Set Events as ADMC Alarms rule converts events that meet rule conditions to
alarms. This enables you to monitor and view events that concern you on the
Current Alarms page. This type of alarms cannot be automatically cleared.
Available events
⚫ Procedure
Open the Network Management app and
choose Monitor > Alarm > Alarm Settings
from the main menu. Alternatively, open the
Alarm Monitor app and choose Alarm
Settings from the main menu.
In the navigation pane, choose Set Events
as ADMC Alarms.
On the Set Events as ADMC Alarms page,
click Add. In the dialog box that is displayed,
select desired events.
Click OK.
Selected events
Page 56 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
Contents
5. Configuring Alarm Rules
5.2 Configuring Aggregation Rules 5.8 Configuring Severity and Type Redefinition
Rules
5.3 Configuring Masking Rules
5.6 Setting Auto Acknowledgement Rules 5.12 Configuring Northbound Filtering Rules
Page 57 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
5.12 Configuring Northbound Filtering
Rules
⚫ On the live network, the upper-layer NMS often receives a large number of alarms.
Network congestion and breakdown may occur due to overload, and users cannot
quickly locate their concerned alarms. To solve this problem, users can set
northbound filtering rules in Alarm Management to determine whether to report the
alarms that meet conditions to the upper-layer NMS.
⚫ Procedure
Open the Network Management app and choose Monitor > Alarm > Alarm Settings from
the main menu. Alternatively, open the Alarm Monitor app and choose Alarm Settings from
the main menu.
In the navigation pane, choose Northbound Filtering Rules.
On the Northbound Filtering Rules page, click Create. Then, configure a filtering rule.
▪ Severity: Filters alarms by alarm severity.
▪ Alarms: Specifies the target alarms.
▪ Alarm sources: Filters alarms based on the NEs where the alarms are generated.
▪ Advanced conditions: Sets more alarm parameters to filter alarms.
▪ Action: Determines whether to report alarms meeting this rule to the upper-layer NMS.
Click OK.
Page 58 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
5.12 Configuring Northbound Filtering
Rules
Page 59 Copyright © 2019 Huawei Technologies Co., Ltd. All rights reserved.
Recommendations
⚫ Huawei - Building A Better Connected World