Design of Boundary wall with Strip foundation‐ wall location
Sno Description = Value Units
1 Net SBC of soil at fdn depth = 30.5 Kn/sqm
1 Height of the boudnary wall = 2.5 m
2 Grade of concrete = 20 N/Sqmm
3 Grade of steel = 500 N/Sqmm
4 Grade of cement mortar for brickwork =
5 Wind speed = 47 m/s
6 Value of K1 = 0.71
7 Value of K2 = 0.8 Terrain cat 4
8 Value of K3 = 1
9 Value of K4 = 1
10 Vz = Vb x k1 x k2 xk3 xk4 = 26.696
11 Pz= 0.6 x Vz x vz = 428 N/m2
12 Pz in KN/sqm = 0.428 KN/m2
13 Density of soil = 18 kn/cum
13 Density of brickwork = 20 kn/cum
14 Density of RCC = 25 kn/cum
15 width of brickwork = 0.23 m 0.23
16 Depth of the foundation = 1.5 m
17 Width of foundation = 1.3 m
18 Thickness of foundation = 0.3 m
19 Width of plinth beam = 0.3 m
20 Thickness of beam = 0.3 m 2.5
Loads and moments calculation
A) BASE PRESSURE CHECK
Moment due to wind load is considered pillar design due to H/L ratio
=1, where H=2.5m and Length between the piers =2.5m
weight of Brickwork/m = 15.64 KN/m NGL
Weight of plinth beam/m = 2.25 KN/m
weight of soil above footing/m = 23.112 KN/m 0.3
1.2
weight of foundation/m = 7.5 KN/m
0.3
Total dead weight of BW/m = 48.502 KN/m
Moment due to wind load is not considered
due to H/L ratio =1 = 0 KN‐m/m 0.3
P/A = 37.31 KN/sqm
M/z = 0 KN/sqm 0.5 0.3 0.5
P/A+M/Z ( Max pressure) = 37.3092308 KN/sqm 1.3
P/A‐M/Z ( Min pressure) shall not be < 0 = 37.3092308 KN/sqm
Gross SBC = 57.5 KN/sqm
Check for base pressure is OK
B) Overturning check
Total overturniing moment due to wind @
Base = 0
The total resiting moment (P X fdn width/2) = 31.5263
Factor of safety RM/OTM = NA
Check for Over turning is OK
C) Check for Sliding
Total horizontal wind force at the base of fdn = 1.07 Kn/m
Total resisiting force from the wt of fdn = 14.5506 Kn/m
Factor of safety = 13.60
Check for Sliding is OK
Page 1 of 2
Design of Boundary wall with Strip foundation‐ wall location
Sno Description = Value Units
D) Design of foundation
Max pressure of the foundation = 37.31 Kn/m
Factored pressure from the foundation = 55.96 Kn/m
Max bending moment at the face of beam = 27.98 Kn‐m/m
Depth required as per BM = 88 mm
Depth provided in mm is = 300 ok
Effective depth = 250 mm
2
MU / ( b X d2 ) = 0.45 N / MM
Shear at above point = 28 KN/m
2
PU / ( b X d ) = 0.11 N / MM
2
Allowable shear stress = 0.28 N / MM
Shear stress of the footing is OK
% of Steel as per Table ‐ 3 of SP : 16 = 0.104
% of Steel as per Table ‐ 19 of IS: 456 = 0.120
Required Area of Steel for Maximum of
3.00 Sq.CM
above =
Min. Requirement as 0.12% of Gross Area 3.60 Sq.CM
=
Max. of above = 3.60 Sq.CM
Reinforcement Dia Proposed = 10 MM
Spacing Proposed as per above & to Table‐
100 MM
96 =
Provided Area of Steel as per Table‐96 = 7.86 Sq.CM
Provide 10 Dia @ 100 C/C in both ways
Page 2 of 2