Rexroth RE 30263-R Sensor Angulo Desplazamiento
Rexroth RE 30263-R Sensor Angulo Desplazamiento
RE 30263-R
Type ASSEMBLY KIT VT-SWA-LIN Edition: 2016-10
General
H7175
Notice:
The sensor to be installed has to be selected according
to the pump size due to the different lengths of the (-3-) ab NG 250
sensor probe tips (see ordering code in data
sheet 30263). Installation of an incorrect probe tip
leads to malfunction of the swivel angle sensor.
Check "zero" swivel angle (while system is on) Check "100%" swivel angle (while system is on)
1. Close all directional valves 1. Swivel angle command value greater than 10.5 V and/or
2. Set a swivel angle command value >5 V and/or >50% 105%, pressure command value approx. 100 bar (With
3. Set a pressure command value of 20 bar (if this is SYHDFED valve command value >50% via the valve
technically impossible, set 0 V) direct control)
2. Let the full volume flow via the actuator, e.g. activate
Notice:
hydraulic motor or set pressure relief valve to
If an external pilot oil supply is used, the pressure
approx. 20 bar; this causes a deliberate error message
command value must be > 2 bar.
by the pilot valve (control deviation too high)
4. Switch on hydraulics and let pump warm up 3. Verify whether the actual swivel angle value (αactual) is
(approx. 5 min.) 10.05 V ±0.01 V (+100.5% ±0.1%). (With analog
5. Verify whether the actual swivel angle value (αactual) is electronics at the central connector of the pilot valve,
0 V ±0.01 V and/or 0 % ±0.1%. (With analog electronics pin 6, violet; with digital electronics via WIN-PED and/or
at the central connector of the pilot valve, pin 6, violet; IndraWorks)
with digital electronics via WIN-PED and/or IndraWorks) Analog systems:
Analog systems: In case of variation, use potentiometer (2) to calibrate;
In case of variations, use potentiometer (1) to calibrate; the potentiometer is marked with "G" (= Gain) on the
the potentiometer is marked with "O" (=Offset) on the swivel angle sensor
swivel angle sensor Digital systems:
Digital systems: Start swivel angle - factor calibration via the WIN-PED
Start swivel angle - zero point / swivel angle - offset software or IndraWorks.
calibration via the WIN-PED software or IndraWorks.
VT-SWA-LIN…K44
G
1 2
Notes
Bosch Rexroth AG © This document, as well as the data, specifications and other information set
Hydraulics forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
Zum Eisengießer 1 reproduced or given to third parties without its consent.
97816 Lohr am Main, Germany The data specified above only serve to describe the product. No statements
Phone +49 (0) 93 52 / 18-0 concerning a certain condition or suitability for a certain application can be
[email protected] derived from our information. The information given does not release the user
www.boschrexroth.de from the obligation of own judgment and verification. It must be remembered
that our products are subject to a natural process of wear and aging.