Q.PEAK DUO XL-G11.
7
570-590
EXCELLENT RELIABILITY
AND OUTSTANDING YIELDS
BREAKING THE 21 % EFFICIENCY BARRIER
PERC Technology with zero gap cell layout boosts
module efficiency up to 21.7 %.
LOW ELECTRICITY GENERATION COSTS
Higher yield per surface area, lower BOS costs and up to 175 watts more
module power than standard 144 half-cell modules.
ENDURING HIGH PERFORMANCE
Long-term yield security thanks to regular PID and Hot-Spot tests
according to IEC requirements.
EXTREME WEATHER RATING
High-tech aluminium alloy frame, certified for
high snow (5400 Pa) and wind loads (2400 Pa).
A RELIABLE INVESTMENT
Inclusive 12-year product warranty and 25-year
linear performance warranty1.
2
See data sheet on rear for further information.
THE IDEAL SOLUTION FOR:
Ground-mounted
solar power plants
MECHANICAL SPECIFICATION
Format 2416 mm × 1134 mm × 35 mm (including frame)
Weight 30.7 kg AU/ 2416 mm
1400 mm
Front Cover 3.2 mm thermally pre-stressed glass with 790 mm
EN
400 mm 508 mm
anti-reflection technology 4 × Grounding holes, Ø 4.5 mm 4 × Drainage holes
Back Cover Composite film 8 × Mounting slots system Tracker (DETAIL B)
Frame
≥ 750 mm
Frame Anodised aluminium 1090 mm
1092 mm
Cell 6 × 26 monocrystalline PERC solar half cells 1134 mm
Junction box 53-101 mm × 32-60 mm × 15-18 mm
Protection class IP67, with bypass diodes ≥ 350 mm 4 × Drainage holes
Label 2.8 × 6 mm
Cable 4 mm² Solar cable; (+) ≥ 750 mm, (−) ≥ 350 mm 4 × Drainage holes
4 × Mounting slots (DETAIL A) 3 × 6 mm
Connector Stäubli MC4-Evo2, Hanwha Q CELLS HQC4; IP68
16 mm 10 mm
35 mm DETAIL A DETAIL B
8.5 mm 7 mm
21 mm 22 mm
Drawing not to scale
ELECTRICAL CHARACTERISTICS
POWER CLASS 570 575 580 585 590
MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5 W / −0 W)
Power at MPP1 PMPP [W] 570 575 580 585 590
Short Circuit Current1 I SC [A] 13.49 13.51 13.54 13.57 13.59
Minimum
Open Circuit Voltage1 VOC [V] 53.59 53.62 53.64 53.67 53.70
Current at MPP I MPP [A] 12.82 12.87 12.92 12.97 13.01
Voltage at MPP VMPP [V] 44.46 44.68 44.90 45.12 45.33
Efficiency1 η [%] ≥ 20.8 ≥ 21.0 ≥ 21.2 ≥ 21.4 ≥ 21.5
MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2
Power at MPP PMPP [W] 427.6 431.4 435.1 438.9 442.6
Short Circuit Current I SC [A] 10.87 10.89 10.91 10.93 10.95
Minimum
Open Circuit Voltage VOC [V] 50.54 50.56 50.59 50.62 50.64
Current at MPP I MPP [A] 10.09 10.13 10.17 10.22 10.26
Voltage at MPP VMPP [V] 42.39 42.58 42.77 42.96 43.14
1
Measurement tolerances PMPP ± 3 %; I SC; VOC ± 5 % at STC: 1000 W/m2, 25 ± 2 °C, AM 1.5 according to IEC 60904-3 • 2 800 W/m², NMOT, spectrum AM 1.5
Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE
100 110
RELATIVE EFFICIENCY [%]
RELATIVE EFFICIENCY
COMPARED TO NOMINAL POWER [%]
98
Q CELLS
Industry standard for linear warranties*
At least 98 % of nominal power dur-
ing first year. Thereafter max. 0.5 %
95 degradation per year. At least 93.5 % 100
of nominal power up to 10 years. At
least 86 % of nominal power up to
90
25 years. 90
EN 86
85
All data within measurement toler-
ances. Full warranties in accordance 80
with the warranty terms of the 200 400 600 800 1000
Q CELLS sales organisation of your IRRADIANCE [W/m²]
80
0 5 10 15 20 25 respective country.
*
Standard terms of guarantee for the 10 PV companies YEARS Typical module performance under low irradiance conditions in
with the highest production capacity in 2014 (as at: September 2014)
comparison to STC conditions (25 °C, 1000 W/m2).
Specifications subject to technical changes © Q CELLS Q.PEAK DUO XL-G11.7_570-590_2021-07_Rev01_EN
TEMPERATURE COEFFICIENTS
Temperature Coefficient of I SC α [% / K] +0.04 Temperature Coefficient of VOC β [% / K] −0.27
Temperature Coefficient of PMPP γ [% / K] −0.34 Nominal Module Operating Temperature NMOT [°C] 43 ± 3
PROPERTIES FOR SYSTEM DESIGN
Maximum System Voltage VSYS [V] 1500 PV module classification Class II
Maximum Reverse Current IR [A] 25 Fire Rating C
Max. Design Load, Push / Pull [Pa] 3600 / 1600 Permitted Module Temperature −40 °C - +85 °C
on Continuous Duty
Max. Test Load, Push / Pull [Pa] 5400 / 2400
QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION
IEC 61215:2016; 24t
IEC 61730:2016. 40' HC
This data sheet complies
with DIN EN 50380. Vertical 2458 mm 1134 mm 1260 mm 999 kg 20 pallets 16 pallets 31 modules
packaging
Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and
use of this product.
Hanwha Q CELLS GmbH
Sonnenallee 17-21, 06766 Bitterfeld-Wolfen, Germany | TEL +49 (0)3494 66 99-23444 | FAX +49 (0)3494 66 99-23000 | EMAIL