0% found this document useful (0 votes)
26 views1 page

An 60015

The document provides instructions for using a test board to evaluate different Gali amplifier models (Gali-K2, Gali-52, Gali-S66, etc.). The test board allows selection of the appropriate amplifier model by soldering a jumper wire across positions 1-5 on the board. To test a model, solder it onto the board and connect the jumper wire according to the table for the selected mode. Calibrate the setup by connecting an RF output to a network analyzer and applying input from the analyzer. Add the insertion loss values in the table to measured gains to determine the actual amplifier gains.

Uploaded by

Clena
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
26 views1 page

An 60015

The document provides instructions for using a test board to evaluate different Gali amplifier models (Gali-K2, Gali-52, Gali-S66, etc.). The test board allows selection of the appropriate amplifier model by soldering a jumper wire across positions 1-5 on the board. To test a model, solder it onto the board and connect the jumper wire according to the table for the selected mode. Calibrate the setup by connecting an RF output to a network analyzer and applying input from the analyzer. Add the insertion loss values in the table to measured gains to determine the actual amplifier gains.

Uploaded by

Clena
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Gali-SXF Kit Test Board: Instructions for Use

(for testing all kit “K2-Gali”models, plus Gali-52 and Gali-S66)


(AN-60-015)
Introduction Procedure
Gali Models are a series of wide band amplifiers. They have different Follow these steps to use the Test Board
device voltages and currents (refer to catalog spec). The test board has Figure 2 shows the layout
been constructed in such a way as to make it useful for evaluating all the
devices by suitable selection of bias resistor. This is done by soldering a 1. Solder selected Gali unit onto Test
jumper wire across one of the dashed-line positions 1 to 5 shown in Fig.1 Board.
2 Make DC connection by soldering jumper
The Test Board has the following components: wire in accordance with the
Component Value Function Model
No.
Short at
Position
Table, depending on the selected Gali
mode. All other positions should be
C1 & C2 39000 pF DC blocking Gali-S66 2
open.
L1 MCL Model # RF choke Gali-6F 1
ADCH-80A 3 Calibrate test setup.

R1 100Ω Sets bias current for K2-Gali and Gali-4F 1 4 First, connect the RF output port of the
Gali-52 test board to Network/Spectrum
R2 394Ω Sets bias current for Gali-S66 Gali-51F 1 analyzer. Then, apply +10 V DC.
Finally, apply RF input to the test board
Gali-5F 1 from Network Analyzer.

Gali-55 1 5 Test Board has Insertion Loss due to the


length of its lines, DC blocking
Gali-52 1 capacitors and RF choke as shown
below. Add this loss to the measured
R3 11Ω Sets bias current gain to get actual gain.

D1 Zener, 10V Protects against excessive supply Frequency Insertion Loss


voltage (GHz) (dB)
1 0.64
C3 0.1 μF Bypass capacitor 2 1.03
Bypasses noise of supply voltage 3 1.63
4 1.32
5 1.46
Fig 1. Schematic of the Test Board Gali-TBF 6 1.90
8 3.21

Fig 2. Layout of the Test Board

AN-60-015 Rev.: C M112401 (07/20/07) File: AN60015.DOC