0% found this document useful (0 votes)
52 views

STRUCTURAL

This document provides design codes and references that shall govern the design, fabrication, and construction of a project. It lists American Concrete Institute ACI 318-14, National Structural Code of the Philippines (NSCP) Volume 1, and other references. It also provides specifications for reinforced concrete including concrete mixing and placing, with requirements for design mix, placement, formwork, inspection prior to pouring, and submittal of concrete mix design.

Uploaded by

Kevin Namaya
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
52 views

STRUCTURAL

This document provides design codes and references that shall govern the design, fabrication, and construction of a project. It lists American Concrete Institute ACI 318-14, National Structural Code of the Philippines (NSCP) Volume 1, and other references. It also provides specifications for reinforced concrete including concrete mixing and placing, with requirements for design mix, placement, formwork, inspection prior to pouring, and submittal of concrete mix design.

Uploaded by

Kevin Namaya
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

GENERAL 2.

DESIGN CODE AND REFERENCE


CONSTRUCTION
THE FOLLOWING REFERENCES SHALL GOVERN THE DESIGN FABRICATION & CONSTRUCTION OF THE PROJECT:
1. SETTING OUT
1.1. GENERAL NOTES AND TYPICAL STRUCTURAL DETAILS SHALL APPLY TO ALL DRAWINGS UNLESS OTHERWISE SHOWN OR NOTED.
THE SETTING OUT AND THE ELEVATIONS OF THE DIFFERENT COMPONENTS OF THE STRUCTURE SHALL BE APPROVED BY THE ENGINEER
1.2. FEATURES OF CONSTRUCTION SHOWN ARE TYPICAL AND SHALL APPLY GENERALLY THROUGHOUT FOR SIMILAR CONDITIONS. · AMERICAN CONCRETE INSTITUTE ACI 318-14 BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE.
PRIOR TO THE START OF ANY CONSTRUCTION WORKS.
MODIFY TYPICAL DETAILS AS REQUIRED TO MEET SPECIAL CONDITIONS.
1.3. THE CONTRACTOR SHALL EXAMINE THE DRAWING AND SHALL NOTIFY THE ENGINEER / ARCHITECT OF ANY DISCREPANCIES HE MAY · NATION STRUCTURAL CODE OF THE PHILIPPINES (NSCP) VOLUME 1, PHILIPPINES 7TH EDITION, 2015.
2. REINFORCED CONCRETE
FIND BEFORE PROCEEDING WITH THE WORK, OR DURING CONSTRUCTION. A. CONCRETE MIXING AND PLACING
1.4. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ADEQUATE SHORING AND BRACING FOR THE STRUCTURE FOR ALL · ASSOCIATION OF STRUCTURAL ENGINEERS OF THE PHILIPPINES (ASEP) HANDBOOK OF STRUCTURAL STEEL SHAPES AND SECTIONS.
LOADS THAT MAYBE IMPOSED DURING CONSTRUCTION. (1) DESIGN MIX SHALL MEET THE DESIGN CONCRETE STRENGTH GIVEN UNDER ITEM 1 MATERIALS.
1.5. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE LATEST APPLICABLE STANDARD OR SPECIFICATIONS. ALL WORKS · FEDERAL EMERGENCY MANAGEMENT AGENCY (FEMA) P-320/ P-361.
SHALL CONFORM WITH THE BEST PRACTICE PREVAILING IN THE VARIOUS TRADES. (2) CONCRETE SHALL BE DEPOSITED VIBRATED AND CURED IN ACCORDANCE WITH THE SPECIFICATIONS.
1.6. ALL CONSTRUCTION AND WORKMANSHIP SHALL BE SUBJECT TO INSPECTION, EXAMINATION AND TESTING BY THE ENGINEER / · UBC 1997, STRUCTURAL ENGINEERING DESIGN PROVISION.
ARCHITECT. THE ENGINEER / ARCHITECT SHALL HAVE THE RIGHT TO REJECT DEFECTIVE MATERIALS AND WORKMANSHIP OR REQUIRE (3) FOR CONCRETE DEPOSITED AGAINST THE GROUND, LEAN CONCRETE WITH A MINIMUM THICKNESS OF 50mm SHALL BE LAID FIRST
ITS CORRECTION · STRUCTURAL DESIGN DATA AND SPECIFICATIONS A.A CARILLO, 6TH EDITION.
BEFORE INSTALLING THE REINFORCEMENT, THE LEAN CONCRETE SHALL BE CONSIDERED IN MEASURING THE STRUCTURAL DEPTH OF
1.7. UNLESS SPECIFICALLY DETAILED ELSE WHERE, THE CONTRACTOR SHALL FOLLOW TYPICAL DETAILS AS SHOWN IN THESE CONCRETE SECTION.
DRAWINGS.
1.8. THE CONTRACTOR WILL BE RESPONSIBLE FOR THE COORDINATION OF WORKS AMONG THE VARIOUS TRADES AS NECESSARY TO (4) THE CONTRACTOR SHALL SUBMIT TO THE ENGINEER FOR APPROVAL, POURING SEQUENCE FOR ALL CONCRETING WORK.
AVOID CONFLICT AND ENSURE THE INSTALLATION OF ALL WORKS WITHIN THE AVAILABLE SPACE.
1.9. DO NOT SCALE DRAWINGS AND CALLED-OUT DIMENSIONS. STANDARD CODE REQUIREMENTS SHALL GOVERN OVER UNSCALED (5) THE CONTRACTOR SHALL NOTIFY THE ENGINEER 48 HOURS PRIOR TO THE POURING OF ANY STRUCTURAL CONCRETE SO AN INSPECTION

1.10.
DRAWING.
SPECIAL NOTES AND DIMENSIONS INDICATED ON THE STRUCTURAL DRAWING SHALL BE COORDINATED WITH THE ARCHITECTURAL MATERIALS CAN BE MADE ON ALL FORMS AND REINFORCING.

DRAWINGS. ARCHITECTURAL DRAWINGS SHALL BE USED TO DEFINE DETAILS CONFIGURATION, ELEVATIONS, OPENING JOINTS, (6) PREPARE AND SUBMIT CONCRETE MIX DESIGN INCLUDING AGGREGATES GRADATION, WATER AND CEMENT CONTENTS AND CYLINDER
1. CONCRETE
SLOPE, ETC. STRENGTH TEST RESULT FOR REVIEW, CONCRETE MIX DESIGN SHALL BE TESTED AT 7,14 AND 28 DAYS CURING PERIOD. THE TEST SHALL
1.11. MODIFICATION SECTION AND SIZE OF STRUCTURAL MEMBER SHALL NOT BE ALLOWED UNLESS OTHERWISE APPROVED BY THE FOLLOW THE REQUIREMENT OF ASTM.
UNLESS INDICATED OTHERWISE ON PLANS, THE CONCRETE CLASS AND STRENGTH SHALL AS FOLLOWS:
STRUCTURAL ENGINEER.
1.12. CONTRACTOR TO PROVIDE DYE PENETRANT / ULTRASONIC TESTING RESULT TO CLIENT. THESE TESTING SHALL BE CONDUCTED BY (7) USE ADMIXTURE IS PERMITTED TO PRODUCE PROPER SLUMP AND WORKABILITY BUT SUBJECT TO THE ENGINEER'S APPROVAL, ADDITION
ACCREDITED AGENCY. OF WATER TO CONCRETE AT JOB SITE IS NOT ALLOWED.
1.13. IN CASE STRUCTURAL MEMBER SPECIFIED ARE NOT AVAILABLE, SUBMIT TO CLIENT ENGINEER AVAILABLE LIST OF MEMBERS FOR 28-DAYS CYLINDER STRENGTH
APPROVAL BEFORE PURCHASING. STRUCTURAL ELEMENTS CLASS MAX. SLUMP mm (inch)
MPa (PSi) (8) FIR CONCRETE SLAB, ALL REINFORCEMENT SHALL BE 0.02m CLEAR MINIMUM FROM TOP AND BOTTOM OF SLAB. TEMPERATURE
BARS SHALL BE GENERALLY PLACED NEAR THE FACE TENSION AND SHALL NOT BE LESS THAN 0.0018 Bt.
SLAB, STAIR, CURBS AND SLAB ON GRADE "A" 20.7 (3000) 75(3")

CAST-IN-PLACE GIRDERS, BEAMS, FOOTINGS AND (9) FOR TWO OR MORE LAYERS OF REINFORCING BARS, USE SEPARATORS SPACED @ 0.90 O.C. AND IN NO CASE SHALL BE LESS THAN 2
"AA" 27.6 (4000) 100 (4") SEPARATORS. CLEAR DISTANCE FOR CAMBER:
COLUMN
OTHER STRUCTURAL ELEMENTS "A" 20.7 (3000) 100 (4")
FOR NON STRUCTURAL MEMBERS - 17.2 (2500) 100 (4")
LEAN CONCRETE - 10.0 (1450) 75 (3") COMPONENT SPECIFICATIONS
R.C. BEAMS 6 mm EVERY 4.50m. SPAN
DESIGN CRITERIA ITEMS AGGREGATE SIZE CANTILEVER R.C. BEAM 18 mm FOR EVERY 3.00m. SPAN

FOOTING 205 mm (1") R.C. SLABS 3mm FOR EVERY 3.00m. SHORTER SPAN
1. LOADS 3
SLAB, BEAMS, COLUMN, OTHERS. 19 mm (4")
1.1. DEAD LOADS
3
UNIT WEIGHT OF CONCRETE 24.00 kN/m CURBS AND MASS, CONCRETE/ SLAB ON GRADE 25 mm (1")
UNIT WEIGHT OF SOIL 18.00 kN/m3 (10) COLUMN TIES SHALL BE PROTECTED BY A COVERING OF CONCRETE CAST MONOLITHICALLY WITH 0.05m THICK AND NOT LESS THAN
1.1. INFORM ARCHITECT/ ENGINEERS OF OTHER MISCELLANEOUS CONCRETE STRUCTURAL ELEMENTS NOT SHOWN ABOVE TO 1
ROOFING (GI SHEET AND PURLINS) 0.37 kPa 2 TIMES MAXIMUM SIZE OF COURSE AGGREGATES.
100 mm CHB WALL 3.17 kPa DETERMINE THEIR RESPECTIVE COMPRESSIVE STRENGTH.
FLOOR FINISH 1.53 kPa (11) LOCATION OF ALL CONSTRUCTION OR CLOD JOINTS MUST BE APPROVED BY THE ENGINEER / ARCHITECT.
PARTITION LOAD 1.00 kPa
CEILING 0.25 kPa 2. REINFORCING STEEL (12) PIPES OR DUCTS EXCEEDING ONE THIRD THE SLAB OR WALL THICKNESS SHALL NIT BE PLACED IN STRUCTURAL CONCRETE UNLESS
INSULATION 0.08 kPa A. REINFORCING STEEL CONFORM TO LATEST EDITION OF ASTM A615 GRADE 60, DEFORMED, FOR 16mm DIAMETER, BARS AND SPECIFICALLY DETAILED. PIPES MAY PASS THROUGH STRUCTURAL CONCRETE IN SLEEVES BUT SHALL NOT BE EMBEDDED THEREIN.
WATERPROOFING 0.26 kPa LARGER WITH MINIMUM YIELD STRENGTH = 414 MPa (60,000 PSi).
ELECTRICAL/MECHANICAL/PLUMBING 0.35 kPa B. ALL REINFORCING BARS SHALL BE DEFORMED BARS UNLESS OTHERWISE SPECIFIED IN DRAWINGS. (13) REINFORCING BARS, ANCHOR BOLTS, AND OTHER INSERTS SHALL BE SECURED IN PLACE BEFORE POURING CONCRETE, BARS
1.2. LIVE LOADS C. ALL REINFORCING BARS SHALL BE CLEAN OF RUST, GREASE OR OTHER MATERIALS UNLIKE TO IMPAIR BOND. PLACEMENT AND SUPPORTS SHALL BE IN ACCORDANCE WITH THE RECOMMENDED ACI PRACTICE.
ROOF 1.00 kPa D. ALL REINFORCING BARS SHALL ACCURATELY AND SECURELY PLACED BEFORE POURING OF CONCRETE OR APPLYING MORTAR OR
RESIDENTIAL BASIC FLOOR AREA 1.90 kPa GROUT. (14) ALL INSERTS, ANCHOR BOLTS, ETC. TO BE EMBEDDED IN THE CONCRETE SHALL BE HOT DIP GALVANIZED UNLESS NOTED OTHERWISE.
STORAGE 1.90 kPa
RESTROOM 2.40 kPa 3. STRUCTURAL STEEL BOLTS/ WELDS (15) IN GENERAL, THE LATEST EDITION OF THE MANUAL OF STANDARD PRACTICE FOR DETAILING CONCRETE STRUCTURES, ACI 315-99,
SHALL BE ADHERED TO, UNLESS SHOWN OTHERWISE.
1.3. WIND LOAD
WIND VELOCITY, V 270 kph B. BAR BENDING, SPLICING AND PLACING
OCCUPANCY CATEGORY IV
IMPORTANCE FACTOR, Iw 1.0 MATERIALS SPECIFICATIONS (1) THE CONTRACTOR SHALL SUBMIT TO THE ENGINEER FOR APPROVAL ALL SHOP DRAWINGS INDICATING THE BENDING, CUTTING,
EXPOSURE TYPE B SPLICING AND INSTALLATION OF ALL REINFORCING BARS.
STEEL PLATES AND ROLLED SHAPES ASTM A36
VELOCITY PRESSURE 47.3E-6.Kz.Kzt.V2.Iw
BOLTS ASTM A325 (2) BARS SHALL BE BENT COLD, BARS PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT UNLESS PERMITTED BY THE
1.4. SEISMIC LOADS WELDS AWS D1.1 - 183, E70XX SERIES ENGINEER.
SEISMIC ZONE FACTOR, Z 0.40 (ZONE 4)
IMPORTANCE FACTOR, I 1.00 (3) BAR SPLICING NOT INDICATED ON DRAWING SHALL BE SUBJECT TO THE APPROVAL OF ENGINEER.
SOIL PROFILE TYPE SD
SEISMIC SOURCE TYPE A (4) WELDED SPLICES, IF APPROVED BY THE ENGINEER, SHALL DEVELOP IN TENSION AT LEAST 125 OF THE SPECIFIED YIELD STRENGTH
NEAR SOURCE FACTOR, Na 1.00 OF THE BARS.
NEAR SOURCE FACTOR, Nv 1.00
(5) LAPPED SPLICES SHALL BE STAGGERED WHERE POSSIBLE.

REPUBLIC ACT 9266, : ARTICLE 2 SEC. 25(4)


CADD BY: REVISION: DATE:
ENGINEER: PROJECT TITLE: PROJECT OWNER: SHEET CONTENT: SHEET NO.:

Namaya Construction DRAWING AND SPECIFICATIONS DULY SIGNED, STAMP OR SEALED AS INSTRUMENT OF SERVICE
ARE THE PROPERTIES AND DOCUMENTS OF THE ARCHITECT WHETHER THE OBJECT FOR WHICH THEY ARE

PROPOSED BUNGALOW RESIDENTIAL BUILDING MR. MACREEN ATENDIDO


S001
MADE IS AXECUTED OR NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON, WITHOUT THE WRITTEN
CENSENT OF THE ARCHITECT OR AUTHOR OF SAID DOCUMENTS TO DUPLICATE OR TO MAKE COPIES OF
CONSTRUCTION | DESIGNING | CONSULTANT
SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR OTHER PROJECTS OR BUILDING, WHETHER
EXECUTED PARTLY OR INCLUDED.

LOCATION:
PRC: PTR: C.T.C NO.: HOME ADDRESS:
PARAS ST., MAMBANGNAN, SAN LEONARDO, NUEVA ECIJA, 3102 GENERAL NOTES
SAN LEONARDO, NUEVA ECIJA PRESIDENTIAL DECREE

7 28
0960 550 2523 | 0947 879 2832
VALIDITY: DATE ISSUED: DATE ISSUED:
[email protected] "PROTECTION AND INTELLECTUAL PROPERTY" NOVEMBER 14, 1972
POBLACION, SAN LEONARDO, NUEVA ECIJA, 3102
DATE APPROVED:
WORKS OF ART, ARCHITECT MODELS AND DESIGNS ARE CREATIVE WORK
TIN: PLACE: PLACE ISSUED:
DATE: JANUARY 5, 2024 (FRIDAY) AND CONSIDERED OR PART OF THE INTELLECTUAL PROPERTY OF THE AUTHOR DULY PROTECTED UNDER
PRESIDENTIAL DECREE 49.
RECOMMENDED END HOOKS, ALL GRADES (16) TYPICAL LAP SPLICE DETAIL
MIN: d
(6) IN GENERAL, BAR SPLICES SHALL BE MADE AT POINTS OF MINIMUM STRESS. SPLICES SHALL BE SECURELY WIRED TOGETHER STAGGER VERTICAL OFFSET = MAX: d 3mm
SPLICES AT 600mm. WHENEVER POSSIBLE IN BEAMS AND SLABS. SPLICE TOP BARS AT MID SPAN AND BOTTOM BARS NEAR SUPPORT 180 DEGREE HOOK 90 DEGREE HOOK
FINISHED BEND DIAMETER,
SPLICE OF REINFORCEMENT SHALL BE MADE ONLY AS REQUIRED OR PERMITTED ON DESIGN DRAWINGS OR AS ALLOWED BY THE ACI BAR SIZE
D IN (mm) LAP
CODE OR AS AUTHORIZED BY THE ENGINEERS. A OR G (mm) J (mm) A OR G (mm)

d
(7) BARS NOTED AS CONTINUOUS SHALL HAVE MINIMUM SPLICE LENGTH OF 42 BARS DIAMETER BUT NOT LESS THAN 60mm. UNLESS 10 mm Ø 60 130 80 155
12 mm Ø 80 155 105 205
OTHERWISE NOTED.
16 mm Ø 100 180 130 255
20 mm Ø 115 205 155 305 18d MIN
(8) REINFORCEMENT SHALL BE SPLICED ONLY AS INDICATED ON THE DRAWINGS. 25 mm Ø 155 280 205 410 DIAMETER = 30d MAX
28 mm Ø 245 285 300 485 MIN= 12d
(9) ANY WELDING TO BE PERFORMED MUST HAVE PRIOR WRITTEN APPROVAL OF THE ENGINEER. 32 mm Ø 275 435 340 580 MAX= 15d
36 mm Ø 305 485 375 610
(10) WELDING OF REINFORCEMENT STEEL IS NOT PERMITTED UNLESS OTHERWISE SHOWN ON THE DRAWING. WELDING OF REINFORCING
STEEL SHALL CONFORM TO AWS D1. 4-79 AWS STRUCTURAL WELDING CODE OF THE AMERICAN WELDING SOCIETY. REINFORCING (14) TYPICAL STANDARD STIRRUPS AND THE HOOK DETAIL c. CONCRETE COVER TO REINFORCEMENT
STEEL WHICH IS WELDED SHALL CONFORM TO ASTM A 706. REINFORCING STEEL NOT CONFORIMNG TO ASTM A 706 MAY BE USED SEISMIC LOAD
IF THE MATERIAL PROPERTIES OF THE REINFORCING STEEL CONFORM TO AWS D1. 4-79. GENERAL USE
CLEAR CONCRETE COVERING OVER REINFORCING BARS SHALL BE AS FOLLOWS:

HOOK

HOOK
(11) ANCHOR BOLTS, DOWEL AND OTHER EMBEDDED ITEMS ARE TO BE SECURELY TIED IN PLACE BEFORE CONCRETE IS POURED. 12db FOR 19, 22, & 25 COLUMN TO TIES 40 mm

6d

6d
6db FOR 10, 12, & 16 BEAM TO STIRRUPS 40 mm

b
(12) TYPICAL HOOK & SUPPLEMENTARY TIE DETAIL.
FOOTING 75 mm

H
DETAILING DIMENSION

H
DETAILING DIMENTION

DETAILING DIMENTION
NOTES: NOTES: d. CONSTRUCTION JOINT
COLUMN HOOPS HOOK AT EACH ALTERNATIVE 90 & 135 ENDS ON CONSECUTIVE
END FOR 10Ø, 12Ø, 16Ø CROSS TIES A OR G (1) THE POSITION AND FORM OF ANY CONSTRUCTION JOINT SHALL BE AS SHOWN ON DRAWING OR AS AGREED WITH THE

D
db db db ENGINEER.
(2) ALL SURFACES OF CONSTRUCTION JOINTS SHALL BE ROUGHENED TO 6mm. AMPLITUDE,
db

db
10

10

(3) ALL CONSTRUCTION JOINTS SHALL BE CLEANED TO REMOVED DUST, CHIPS, OR OTHER FOREIGN MATTERS PRIOR TO
PLACING OF ADJACENT CONCRETE.
db db
-4 -4
135 135

6db
L.D L.D GENERAL USE GENERAL USE

90
CENTER LINE OF BEAM CENTER LINE OF BEAM CENTER LINE OF BEAM . FALSEWORK
ALL FALSEWORK SHALL BE DESIGNED BY THE CONTRACTOR SUBJECT TO THE APPROVAL BY THE ENGINEER.
db

db

STIRRUPS AND TIE HOOKS, ALL GRADES


. FORMWORK
(13) TYPICAL STANDARD HOOK DETAIL
GENERAL USE SEISMIC USE
BAR SIZE D (mm) (1) FORMS SHALL BE PROVIDED FOR ALL CONCRETE INDICATED UNLESS SPECIFIED OTHERWISE. FORMS SHALL BE SET TRUE
DIMENSION OF 90- DEGREE AND 180- DEGREE HOOKS
90 HOOK O
135 HOOK
O
135 HOOK O

A OR G A OR G H APPROX. A OR G H APPROX. TO LINE AND GRADE AND MAINTAINED SO AS TO ENSURE COMPETENT WORK WITHIN THE ALLOWABLE TOLERANCES
10 mm Ø 40 105 mm 105 mm 55 mm 130 mm 90 mm SPECIFIED AND SHALL BE MORTAR TIGHT.
HOOK 12 mm Ø 55 115 mm 115 mm 80 mm 170 mm 145 mm (2) FORMS AND THEIR SUPPORTS SHALL BE DESIGNED SO AS NOT TO DAMAGE PREVIOUSLY PLACED STRUCTURE.
DETAILING DIMENSION DETAILING DIMENSION
A OR G 16 mm Ø 65 155 mm 140 mm 100 mm 205 mm 140 mm (3) NO CONSTRUCTION LOAD SHALL BE SUPPORTED ON, NOT ANY SHORING REMOVED FROM ANY PART OF THE STRUCTURE
20 mm Ø 145 305 mm 200 mm 145 mm 275 mm 170 mm UNDER CONSTRUCTION EXCEPT WHEN THAT PORTION OF THE STRUCTURE IN COMBINATION WITH THE REMAINING FORMING
db

db

25 mm Ø 155 410 mm 265 mm 145 mm 365 mm 230 mm AND SHORING SYSTEM HAS SUFFICIENT STRENGTH TO SUPPORT SAFETY ITS WEIGHT AND ADDITIONAL IMPOSED LOAD.
180 HOOK D
J
A OF G

(4) FORMS SHALL BE REMOVED IN SUCH MANNER AS NOT TO IMPAIR SAFETY AND SERVICEABILITY OF THE STRUCTURE.
90 HOOK
12db

(5) SHORING (TUKOD) FOR BEAMS/SLABS SHOULD BE REMOVED AFTER 14th DAY.
D

4 db OR (15) IF BEAM REINFORCING BARS END IN A WALL THE CLEAR DISTANCE FROM THE BAR TO THE FARTHER FACE OF THE WALL (6) SCHEDULE OF STRIPPING FORMS AND SHORES.
63mm MIN SHALL NOT BE LESS THAN 50 mm MINIMUM EMBEDMENT LENGTH SHALL BE AS IN TABLE "A".
REMOVAL OF FORMS AND SHORING

PIN DIAMETER: D = 6db FOR DIAMETER 10 THRU DIAMETER 25


STRUCTURAL COMPONENTS CLEAR SPAN BETWEEN SUPPORTS MIN. TIME PERIOD (DAYS)
TABLE A TABLE B
D = 8db FOR DIAMETER 28, DIAMETER 32 AND DIAMETER 36
DEVELOPMENT LENGTH, Ld, IN TENSION FOUNDATION - 1
MINIMUM LENGTH OF
BAR SIZE F'c = 3000 psi (20.68 MPa) F'c = 4000 psi (27.58 MPa) COMPRESSION LAP
WALL, COLUMN, BEAMS GIRDER SIDES
SPLICE (mm) - 3
TOP BARS OTHER BARS TOP BARS OTHER BARS & SLAB ON GRADE
10 mm Ø 525 405 455 350 305
12 mm Ø 700 540 605 465 385 UNDER 3.00 m. 7
16 mm Ø 870 670 755 580 480 JOIST, BEAMS & GIRDER SOFFITS 3.00 m. TO 6.00 m. 14
20 mm Ø 1045 805 905 700 575 OVER 6.00 m. 21
25 mm Ø 1395 1075 1205 930 765 UNDER 3.00 m. 4
28 mm Ø 1570 1210 1360 1050 860 ONE-WAY FLOOR SLABS 3.00 m. TO 6.00 m. 7
32 mm Ø 1770 1360 1535 1180 970 OVER 6.00 m. 10
. PROTECTION AND CURING OF CONCRETE

CONCRETE SURFACES SHALL BE PROTECTED FROM HARMFUL EFFECTS OF SUN, WIND AND RUNNING WATER AND
SHALL BE KEPT DAMP FOR AT LEAST 7 DAYS.

REPUBLIC ACT 9266, : ARTICLE 2 SEC. 25(4)


CADD BY: REVISION: DATE:
ENGINEER: PROJECT TITLE: PROJECT OWNER: SHEET CONTENT: SHEET NO.:

Namaya Construction DRAWING AND SPECIFICATIONS DULY SIGNED, STAMP OR SEALED AS INSTRUMENT OF SERVICE
ARE THE PROPERTIES AND DOCUMENTS OF THE ARCHITECT WHETHER THE OBJECT FOR WHICH THEY ARE

PROPOSED BUNGALOW RESIDENTIAL BUILDING MR. MACREEN ATENDIDO


S002
MADE IS AXECUTED OR NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON, WITHOUT THE WRITTEN
CENSENT OF THE ARCHITECT OR AUTHOR OF SAID DOCUMENTS TO DUPLICATE OR TO MAKE COPIES OF
CONSTRUCTION | DESIGNING | CONSULTANT
SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR OTHER PROJECTS OR BUILDING, WHETHER
EXECUTED PARTLY OR INCLUDED.

LOCATION:
PRC: PTR: C.T.C NO.: HOME ADDRESS:
PARAS ST., MAMBANGNAN, SAN LEONARDO, NUEVA ECIJA, 3102 GENERAL NOTES
SAN LEONARDO, NUEVA ECIJA PRESIDENTIAL DECREE

8 28
0960 550 2523 | 0947 879 2832
VALIDITY: DATE ISSUED: DATE ISSUED:
[email protected] "PROTECTION AND INTELLECTUAL PROPERTY" NOVEMBER 14, 1972
POBLACION, SAN LEONARDO, NUEVA ECIJA, 3102
DATE APPROVED:
WORKS OF ART, ARCHITECT MODELS AND DESIGNS ARE CREATIVE WORK
TIN: PLACE: PLACE ISSUED:
DATE: JANUARY 5, 2024 (FRIDAY) AND CONSIDERED OR PART OF THE INTELLECTUAL PROPERTY OF THE AUTHOR DULY PROTECTED UNDER
PRESIDENTIAL DECREE 49.
3. STRUCTURAL STEEL 7. FINISHES
(19) COMPLY WITH AISC CODE AND SPECIFICATION FOR BEARING, ADEQUACY OF TEMPORARY CONNECTIONS AND ALIGNMENT. FLOORING - PLAIN CEMENT FINISH
(1) ALL STRUCTURAL MILL SECTIONS, AND BUILT-UP PLATE SECTIONS SHALL BE CONSTRUCTED IN ACCORDANCE WITH AISC LATEST COLUMN - PAINT FINISH
"SPECIFICATION FOR DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS" (20) CONTRACTOR SHALL FURNISH COMPLETE ERECTION DRAWINGS FOR THE PROPER IDENTIFICATION AND ASSEMBLY OF THE
BUILDING COMPONENTS. THESE DRAWINGS WILL SHOW ANCHOR BOLTS SETTING. PRIMARY SECONDARY, AND ROOF FRAMING, 8. ROOFING
(2) STEEL PLATES, SHAPES, BARS, AND METAL FABRICATIONS ARE ASTM A-36 UNLESS NOTED OTHERWISE. AND NECESSARY INSTALLATION DETAILS. SUBMIT SHOP DRAWINGS FOR APPROVAL BEFORE FABRICATION.
TRUSSES - 2 S- 50 x 50 x 6mm
(3) SCHEDULE OF BOLTS/NUTS/WASHERS. (21) THE STEEL SUBCONTRACTOR SHALL COMPLY WITH THE LATEST AISC CODE OF STANDARD PRACTICE. STRUTS - 2 S- 50 x 50 x 6mm
BOLTS TYPE/GRADE NUTS ROOFING - PRE- PAINTED LONG SPAN ROOFING SHEET
ASTM A307 GRADE A ASTM A563 (22)THE STEEL SUBCONTRACTOR SHALL DETERMINE THE ERECTION SEQUENCE FOR ALL STEEL WORKS. THE STEEL SUBCONTRACTORS
ASTM 325 (HIGH-STRENGTH BOLTS) TYPE 2 ASTM A563 SHALL ALSO COORDINATE WITH OTHER TRADES AND SITE CONDITIONS IN DETERMINING THE PROPER STEEL ERECTION SEQUENCE
ASTM 490 (QUENCHED AND TEMPERED ALLOY) TYPE 2 ASTM A563 SEQUENCE SO AS NOT TO DAMAGE WORK PERFORMED BY OTHER TRADES AND/OR PREVIOUSLY ERECTED STEEL MEMBERS. 9. PAINTING WORKS

BOLTS WASHERS REMARKS (23)WORK POINTS, MEMBER LENGTH AND/OR ERECTION SEQUENCE SHALL BE ADJUSTED BY THE STEEL SUBCONTRACTOR TO PAINTINGS SHALL BE DONE IN WARM WEATHER CLIMATE. COLOR COMBINATION SHALL BE APPROVED MIXTURE BY THE
ASTM A307 ASTM F436 MINIMIZE THE EFFECT OF THE TEMPERATURE CHANGES AND DIFFERENTIAL TEMPERATURE EFFECTS. TEMPERATURE EFFECTS (SUCH ARCHITECT/CONTRACTOR AND THE OWNER. IT SHALL BE DONE WITH THE USE OF BOYSEN PAINT PRODUCTS OR APPROVED EQUAL.
ASTM 325 (HIGH-STRENGTH BOLTS) ASTM F436 AS EXPOSED TO STRONG SUN ONE ONE SIDE OF THE BUILDING). MEETING AISC ACCEPTABLE MILL STANDARD AND ERECTION
TOLERANCES. 10. CLEANING OF JOB SITE
ASTM 490 (QUENCHED AND TEMPERED ALLOY) ASTM F436 Ø25 mm AND ABOVE
NOTES: A490 BOLTS SHOULD NOT BE HOT-DIPPED GALVANIZED (24)ALL STRUCTURAL STEEL SHALL CONFORM TO ASTM-A36, F =248 MPa (PSi). UPON COMPLETION OF THE WORK THE PREMISES SHALL BE KEPT COMPLETELY CLEAN FROM ANY ACCUMULATED OF
LOOSE MATERIALS
(1) HOLE SIZE FOR ANCHOR BOLTS (25)FABRICATION SHALL SUBMIT SHOP DRAWING FOR APPROVAL BY THE ENGINEER AND OWNER PRIOR TO FABRICATION.

BOLT SIZE Ø (mm.) HOLE SIZE Ø (mm.) 4. FOOTINGS


19 TO 25 INCL DIAM 8
OVER 25 TO 50 INCL DIAM 12 (1) SAFE BEARING CAPACITY (SBC) USED IN THE DESIGN = 162 kPa FOR DEAD PLUS LIVE LOAD WHICH CAN BE INCREASED TO 215
OVER 50 DIAM 25 kPa IF TOTAL DESIGN LOADS INCLUDE WIND OR SEISMIC FORCES AT A MINIMUM DEPTH OF 2.0m FROM THE NATURAL GRADE
SWEDGE TYPE DIAM 19 LINE,AS REFERRED TO THE REPORT BY ENGR. BONIFACIO T. DELA PENA.

(2) UNFINISHED BOTLS SHALL CONFORM TO ASTM A-307 GRADE A. HIGH STRENGTH BOLTS SHALL CONFORM TO ASTM A325 OR (2) FOOTING SHALL REST ON 100mm THK GRAVEL BASE COURSE COMPACTED TO 95 MAXIMUM DENSITY.
ASTM A490 AS NOTED. USE 16mm DIAMETER A325 BOLTS FOR ALL BEAM TO BEAM, BEAM TO GIRDER/COLUMN, GIRDER TO
COLUMN BOLTED CONNECTION. USE TWO BOLTS MIN. UNLESS NOTED OTHERWISE. (3) BACKFILL SHALL BE PLACE IN 150mm LAYERS AND EACH LAYER SHALL BE COMPACTED TO A MINIMUM OF 95 MAXIMUM
DENSITY, SHALL BE FREE FROM DETRIMENTAL AMOUNTS OF ORGANIC MATERIAL & NO ROCK OR SIMILAR IRREDUCIBLE MATERIAL
(3) ALL HIGH STRENGTH BOLTS A325 OR A490 SHALL BE SLIP CRITICAL (A325-SC OR A490-SC CLASS A) UNLESS NOTED W/ A MAXIMUM DIMENSION GREATER THAN 300mm BE BURIED OR PLACED IN FILLS.
OTHERWISE. THE INSTALLATION OF HIGH STRENGTH BOLTS SHALL CONFORM TO THE LATEST EDITION OF AISC SPECIFICATION FOR
STRUCTURAL JOINT USING ASTM A325 OR A490 BOLTS. WHERE NON SLIP CRITICAL BOLTS ARE SPECIFIED. THESE BOLTS SHALL (4) ALL EXCAVATIONS, BACKFILLING AND COMPACTION SHALL BE INSPECTED AND APPROVED BY THE CONTRACTING OFFICER.
ONLY BE TIGHTENED TO A SNUG TIGHT CONDITION.
(5) THE CONTRACTOR SHALL VERIFY THE ACTUAL SOIL CONDITION BEFORE CONSTRUCTION OR AFTER FOOTING EXCAVATION IS
(4) BOLT HOLE IN STEEL SHALL BE 1.6 mm LARGER IN DIAMETER THAN THE DIAMETER OF BOLT USED FOR SLIP CRITICAL DONE TO CHECK THE GEOTECHNICAL REPORTS RECOMMENDED BEARING CAPACITY, IF ANY.
CONNECTIONS CONSTRUCTION OR SHORT SLOTTED HOLES FOR NON-SLIP CRITICAL CONNECTION AS NOTED, UNLESS OTHERWISE
SPECIFIED. (6) NO FOOTING SHALL REST ON FILL.

(5) ELECTRODES FOR WELDING: ASTM 233 E-70XX SERIES COMPLY WITH AWS D1.1 CODE REQUIREMENTS. (7) MINIMUM CONCRETE PROTECTION FOR REINFORCEMENT SHALL BE 75mm FOR CONCRETE DEPOSITED AGAINST THE GROUND.

(6) FLAME CUTTING AND WELDING SHALL BE DONE IN ACCORDANCE WITH THE LATEST "STANDARD CODE FOR WELDING IN BUILDING (8) CONTRACTOR TO PROVIDE FOR DE3-WATERING OF EXCAVATIONS FROM EITHER SURFACE WATER, GROUND WATER OR SEEPAGE.
OF THE AMERICAN WELDING SOCIETY".
(9) CONTRACTOR SHALL PROVIDE FOR DESIGN AND INSTALLATION OF ALL CRIBBING, SHEATHING AND SHORING REQUIRED TO SAFETY
(7) ALL BUTT WELDS SHALL BE FULL PENETRATION AND SHALL PROPERLY BACK-SHIPPED OR GOUGED, BACK-UP PLATES SHALL BE RETAIN THE EARTH BANKS.
PROVIDED AS REQUIRED.
(10) ALL EXCAVATIONS SHALL BE PROPERLY BACKFILLED. DO NOT PLACE BACKFILL BEHIND RETAINING WALLS BEFORE WALLS HAVE
(8) GRIND ALL EXPOSED WELDS SMOOTH, EXCEPT FILLET WELDS. ATTAINED FULL STRENGTH. CONTRACTOR SHALL BRACE OR PROTECT ALL BUILDING AND PIT WALLS BELOW GRADE FROM LATERAL
LOADS UNTIL ATTACHING FLOORS ARE COMPLETELY IN PLACE AND HAVE ATTAINED FULL STRENGTH. CONTRACTOR SHALL
(9) WELD LENGTH CALLED FOR ON PLANS ARE THE NET EFFECTIVE LENGTH REQUIRED. FILLET WELD SIZE ARE THE WIDTH OF THE PROVIDE FOR DESIGN, PERMITS AND INSTALLATION OF SUCH BRACING.
HORIZONTAL OR VERTICAL LEG. WHERE LENGTH OF WELD IS NOT SHOWN IT SHALL NE FULL LENGTH OF JOINTS. WELDING
ELECTRODES TO BE E70XX UNLESS NOTED OTHERWISE. (11) FOOTINGS SHALL BE PLACED AND ESTIMATED ACCORDING TO DEPTH SHOWN ON DRAWINGS. SHOULD SOIL ENCOUNTERED AT
THERE DEPTH NOT BE APPROVED BY THE FOUNDATION ENGINEER, FOOTING ELEVATIONS WILL BE ALTERED AS REQUIRED.
(10) ALL LEVEL WELDS ARE FULL PENETRATION, UNLESS NOTED OTHERWISE, SIZE ALL FILLET WELDS PER AWS WHERE NOT SHOWN
WITH WELD SIZE PROVIDE MIN. WELD SIZE TO DEVELOP TENSION OR SHEAR CAPACITY OF THE SMALLER MEMBER OF PIECES (12) FOOTING BACKFILL AND UTILITY TRENCH BACKFILL WITHIN BUILDING AREA SHALL BE MECHANICALLY COMPACTED IN LAYERS, IN
BEING CONNECTED (4.76 mm MIN.) ACCORDANCE WITH SOIL REPORT. FLOODING WILL NOT BE PERMITTED.

(11) THE CONTRACTOR SHALL PROVIDE MINIMUM 10 mm. CONCRETE COVER AROUND ALL STEEL MEMBERS/ COMPONENTS (WF, TS, 5. MASONRY WORKS
PLATES, BOLTS, ETC.) ADJACENT TO SOIL.
CONCRETE HOLLOW BLOCKS, UNLESS OTHERWISE SPECIFIED SHALL BE 150MM THICK. FOR EXTERIOR WALLS AND 100MM THICK.
(12) WELDED CONNECTIONS BETWEEN MEMBERS OF MOMENT FRAMES SHALL BE TESTED BY NON-DESTRUCTIVE METHOD.
DOWELS SHALL ADOPT DIAMETER 10MM AT 600MM O.C. BOTHWAYS.
(13) APPLY TT-P-645 SHOP PAINT FOR ALL FABRICATIONS.
6. SLAB
(14) SHOP PAINTING FOR STRUCTURAL STEEL SHALL BE RUST INHIBITIVE PRIMER WITH MINIMUM D.F.T 2.0 MILS.
FOR TWO-WAY SLABS, BARS ALONG THE SHORTER SPAN SHALL BE PLACED BELOW THOSE ALONG THE LONGER SPAN AT MID SPAN AND
(15) WELDED CONNECTIONS BETWEEN MEMBERS OF MOMENT FRAMES SHALL BE TESTED BY NON-DESTRUCTIVE METHOD. OVER THE LONGER SPAN AT SECTIONS NEAR SUPPORT (COLUMN LINE). UNLESS OTHERWISE INDICATED, BAR SPACING ALONG COLUMN
STRIP CAN BE APPROXIMATELY 1-1/3 TIMES OF THE MIDDLE STRIP BUT IN NO CASE GREATER THAN 2-1/3 TIMES THE SLAB THICKNESS.
(16) APPLY TT-P-645 SHOP PAINT FOR ALL FABRICATIONS.
PROVIDE EXTRA DIAGONAL REINFORCEMENT AT CORNER SLAB, I.E. WHERETO ADJACENT DISCONTINUOUS SLAB MEET.
(17) SHOP PAINTING FOR STRUCTURAL STEEL SHALL BE RUST INHIBITIVE PRIMER WITH MINIMUM D.F.T 2.0 MILS

(18) TOUCH-UP PAINTING: APPLY PAINT TO EXPOSED AREAS IN MANNER SATISFACTORY TO THE ENGINEER WITH SAME MATERIAL AS
SHOP PAINT.

REPUBLIC ACT 9266, : ARTICLE 2 SEC. 25(4)


CADD BY: REVISION: DATE:
ENGINEER: PROJECT TITLE: PROJECT OWNER: SHEET CONTENT: SHEET NO.:

Namaya Construction DRAWING AND SPECIFICATIONS DULY SIGNED, STAMP OR SEALED AS INSTRUMENT OF SERVICE
ARE THE PROPERTIES AND DOCUMENTS OF THE ARCHITECT WHETHER THE OBJECT FOR WHICH THEY ARE

PROPOSED BUNGALOW RESIDENTIAL BUILDING MR. MACREEN ATENDIDO


S003
MADE IS AXECUTED OR NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON, WITHOUT THE WRITTEN
CENSENT OF THE ARCHITECT OR AUTHOR OF SAID DOCUMENTS TO DUPLICATE OR TO MAKE COPIES OF
CONSTRUCTION | DESIGNING | CONSULTANT
SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR OTHER PROJECTS OR BUILDING, WHETHER
EXECUTED PARTLY OR INCLUDED.

LOCATION:
PRC: PTR: C.T.C NO.: HOME ADDRESS:
PARAS ST., MAMBANGNAN, SAN LEONARDO, NUEVA ECIJA, 3102 GENERAL NOTES
SAN LEONARDO, NUEVA ECIJA PRESIDENTIAL DECREE

9 28
0960 550 2523 | 0947 879 2832
VALIDITY: DATE ISSUED: DATE ISSUED:
[email protected] "PROTECTION AND INTELLECTUAL PROPERTY" NOVEMBER 14, 1972
POBLACION, SAN LEONARDO, NUEVA ECIJA, 3102
DATE APPROVED:
WORKS OF ART, ARCHITECT MODELS AND DESIGNS ARE CREATIVE WORK
TIN: PLACE: PLACE ISSUED:
DATE: JANUARY 5, 2024 (FRIDAY) AND CONSIDERED OR PART OF THE INTELLECTUAL PROPERTY OF THE AUTHOR DULY PROTECTED UNDER
PRESIDENTIAL DECREE 49.
1 2 3 1 2 3

6100 6100
3050 3050 3050 3050

A F1-C1 SB1 F1-C3 TB1 F1-C1


A B3 B3
TB1

S1

4500
4500

TB1 TB1 TB1 B1 S1 B1 B1

B1

2" LOWER
S1 B1
S1

B B B3 B4

10500
F1-C1 SB1 F1-C4 TB1 F1-C3
10500

TB1

3000
3000

TB1 TB1 TB1 B1 S1 B1 STB1

C F1-C1 SB1 F1-C2 TB1 F1-C1


C B1 B1
TB1 S2

3000
3000

B1
TB1 TB1 TB1 B2 B1 S1 B1

B1

D F1-C1 SB1 F1-C4 TB1 F2-C1


D
CB1 S2 CB1
TB1

B1

S004 FOUNDATION PLAN S004 2ND FLOOR FRAMING PLAN


1 2 SCALE 1:100 SI 2 2 SCALE 1:100 SI

REPUBLIC ACT 9266, : ARTICLE 2 SEC. 25(4)


CADD BY: REVISION: DATE:
ENGINEER: PROJECT TITLE: PROJECT OWNER: SHEET CONTENT: SHEET NO.:

Namaya Construction DRAWING AND SPECIFICATIONS DULY SIGNED, STAMP OR SEALED AS INSTRUMENT OF SERVICE
ARE THE PROPERTIES AND DOCUMENTS OF THE ARCHITECT WHETHER THE OBJECT FOR WHICH THEY ARE

PROPOSED BUNGALOW RESIDENTIAL BUILDING MR. MACREEN ATENDIDO


S004
MADE IS AXECUTED OR NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON, WITHOUT THE WRITTEN
CENSENT OF THE ARCHITECT OR AUTHOR OF SAID DOCUMENTS TO DUPLICATE OR TO MAKE COPIES OF
CONSTRUCTION | DESIGNING | CONSULTANT
SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR OTHER PROJECTS OR BUILDING, WHETHER
EXECUTED PARTLY OR INCLUDED. FOUNDATION PLAN
LOCATION:
PRC: PTR: C.T.C NO.: HOME ADDRESS:
PARAS ST., MAMBANGNAN, SAN LEONARDO, NUEVA ECIJA, 3102
SAN LEONARDO, NUEVA ECIJA PRESIDENTIAL DECREE 2ND FLOOR FRAMING PLAN

10 28
0960 550 2523 | 0947 879 2832
VALIDITY: DATE ISSUED: DATE ISSUED:
[email protected] "PROTECTION AND INTELLECTUAL PROPERTY" NOVEMBER 14, 1972
POBLACION, SAN LEONARDO, NUEVA ECIJA, 3102
DATE APPROVED:
WORKS OF ART, ARCHITECT MODELS AND DESIGNS ARE CREATIVE WORK
TIN: PLACE: PLACE ISSUED:
DATE: JANUARY 5, 2024 (FRIDAY) AND CONSIDERED OR PART OF THE INTELLECTUAL PROPERTY OF THE AUTHOR DULY PROTECTED UNDER
PRESIDENTIAL DECREE 49.
1 2 3

6100
3050 3050

A RB1 RB1
ST1
4500

RB1 RB1 RB1

RB1

RB1

B RB1 RB1
ST1
10500
3000

RB1 RB1 RB1

C RB1 RB1
ST1
3000

RB1 RB1 RB1

D RB1 RB1 ST1


CRB1 CRB1

RB1

2'' x 4" x 1.20 mm C-PURLINS SPACE @ 0.60 m W/ CLIP ANGLE


3
BAR 2" x 2" x 16"
S005 ROOF BEAM FRAMING PLAN
1 2 SCALE 1:100 SI
S005 UPPER ROOF FRAMING PLAN
2 2 SCALE 1:100 SI

REPUBLIC ACT 9266, : ARTICLE 2 SEC. 25(4)


CADD BY: REVISION: DATE:
ENGINEER: PROJECT TITLE: PROJECT OWNER: SHEET CONTENT: SHEET NO.:

Namaya Construction DRAWING AND SPECIFICATIONS DULY SIGNED, STAMP OR SEALED AS INSTRUMENT OF SERVICE
ARE THE PROPERTIES AND DOCUMENTS OF THE ARCHITECT WHETHER THE OBJECT FOR WHICH THEY ARE

PROPOSED BUNGALOW RESIDENTIAL BUILDING MR. MACREEN ATENDIDO


S005
MADE IS AXECUTED OR NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON, WITHOUT THE WRITTEN
CENSENT OF THE ARCHITECT OR AUTHOR OF SAID DOCUMENTS TO DUPLICATE OR TO MAKE COPIES OF
CONSTRUCTION | DESIGNING | CONSULTANT
SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR OTHER PROJECTS OR BUILDING, WHETHER
EXECUTED PARTLY OR INCLUDED. ROOF BEAM FRAMING PLAN
LOCATION:
PRC: PTR: C.T.C NO.: HOME ADDRESS:
PARAS ST., MAMBANGNAN, SAN LEONARDO, NUEVA ECIJA, 3102
SAN LEONARDO, NUEVA ECIJA PRESIDENTIAL DECREE UPPER ROOF FRAMING PLAN

11 28
0960 550 2523 | 0947 879 2832
VALIDITY: DATE ISSUED: DATE ISSUED:
[email protected] "PROTECTION AND INTELLECTUAL PROPERTY" NOVEMBER 14, 1972
POBLACION, SAN LEONARDO, NUEVA ECIJA, 3102
DATE APPROVED:
WORKS OF ART, ARCHITECT MODELS AND DESIGNS ARE CREATIVE WORK
TIN: PLACE: PLACE ISSUED:
DATE: JANUARY 5, 2024 (FRIDAY) AND CONSIDERED OR PART OF THE INTELLECTUAL PROPERTY OF THE AUTHOR DULY PROTECTED UNDER
PRESIDENTIAL DECREE 49.
3
403

2144
1302
ST2

817 1000 1000


2817
S006 ST 1
ST2 2 3 SCALE 1:40 SI

ST2

395
1

1390
2'' x 4" x 1.20 mm C-PURLINS SPACE @ 0.60 m W/ CLIP ANGLE
3
BAR 2" x 2" x 16 "

1000 1000 901


S006 LOWER ROOF FRAMING PLAN
1 3 SCALE 1:100 SI
2901

S006 ST 2
3 3 SCALE 1:40 SI

REPUBLIC ACT 9266, : ARTICLE 2 SEC. 25(4)


CADD BY: REVISION: DATE:
ENGINEER: PROJECT TITLE: PROJECT OWNER: SHEET CONTENT: SHEET NO.:

Namaya Construction DRAWING AND SPECIFICATIONS DULY SIGNED, STAMP OR SEALED AS INSTRUMENT OF SERVICE
ARE THE PROPERTIES AND DOCUMENTS OF THE ARCHITECT WHETHER THE OBJECT FOR WHICH THEY ARE

PROPOSED BUNGALOW RESIDENTIAL BUILDING MR. MACREEN ATENDIDO


S006
MADE IS AXECUTED OR NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON, WITHOUT THE WRITTEN
CENSENT OF THE ARCHITECT OR AUTHOR OF SAID DOCUMENTS TO DUPLICATE OR TO MAKE COPIES OF
CONSTRUCTION | DESIGNING | CONSULTANT
SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR OTHER PROJECTS OR BUILDING, WHETHER LOWER ROOF FRAMING PLAN
EXECUTED PARTLY OR INCLUDED.

LOCATION:
PRC: PTR: C.T.C NO.: HOME ADDRESS:
PARAS ST., MAMBANGNAN, SAN LEONARDO, NUEVA ECIJA, 3102 STEEL TRUSS 1 DETAIL
SAN LEONARDO, NUEVA ECIJA PRESIDENTIAL DECREE

12 28
0960 550 2523 | 0947 879 2832 STEEL TRUSS 2 DETAIL
VALIDITY: DATE ISSUED: DATE ISSUED:
[email protected] "PROTECTION AND INTELLECTUAL PROPERTY" NOVEMBER 14, 1972
POBLACION, SAN LEONARDO, NUEVA ECIJA, 3102
DATE APPROVED:
WORKS OF ART, ARCHITECT MODELS AND DESIGNS ARE CREATIVE WORK
TIN: PLACE: PLACE ISSUED:
DATE: JANUARY 5, 2024 (FRIDAY) AND CONSIDERED OR PART OF THE INTELLECTUAL PROPERTY OF THE AUTHOR DULY PROTECTED UNDER
PRESIDENTIAL DECREE 49.
2" X 4" X 1.2mm THK C-PURLINS
SPACE @ 600 MM O.C.

2" X 2" X 41 mm THK WELDED


ANGLE BARS MAIN TRUSS GA 26 PRE-PAINTED
BOX TYPE G.I SHEET FLASHING
0.6 mm THK PRE PAINTED
RIB TYPE ROOF
3/16 X 2 BAR STOPPER
12mm Ø SAG ROD GA 26 PRE-PAINTED
BOX TYPE G.I SHEET FLASHING
AA TEK SCREW 3"
75 MM Ø DOWNSPOUT
CHB WALL

TOP OF ROOF BEAM


BEAM (SEE DETAIL) BEAM (SEE DETAIL)

COLUMN COLUMN COLUMN COLUMN


CHB WALL CHB WALL CHB WALL CHB WALL

GA 26 PRE-PAINTED BOX TYPE GUTTER

S007 TYPICAL STEEL TRUSS DETAILS


1 2 SCALE 1:70 SI

CL EXTERIOR COLUMN CL INTERIOR CL INTERIOR


COLUMN COLUMN
L1 L2 L3

TOP BARS 0.3L1 OR 0.3L2 TOP BARS 0.3L2 OR 0.3L3 0.3L2 OR 0.3L3
0.3 L1 0.3 L1
SPLICE ZONE (TYP.) GREATER SPLICE ZONE (TYP.) GREATER GREATER
CONCRETE COLUMN
CONTINUOUS CONTINUOUS
TOP BARS TOP BARS
EXTRA BAR EXTRA BAR
EXTRA BAR EXTRA BAR
TOP BARS TOP BARS
TOP BARS TOP BARS

EXTRA BOT BARS EXTRA BOT BARS


SIDE BARS
CONTINUOUS FOR SIZE AND SPACING CONTINUOUS
BOTTOM BARS OF STIRRUPS, SEE RC BOTTOM BARS
BEAM SCHEDULE
1 1 1 1 1
8 L1 8 L1 8 L2 8 L2 8 L3

DISCONTINUOUS END BOTTOM BARS BOTTOM BARS


CONCRETE COLUMN SPLICE ZONE (TYP.) CONCRETE COLUMN SPLICE ZONE (TYP.)
CONTINUOUS END CONTINUOUS END
S007 TYPICAL BEAM DETAILS
2 2 SCALE NTS

REPUBLIC ACT 9266, : ARTICLE 2 SEC. 25(4)


CADD BY: REVISION: DATE:
ENGINEER: PROJECT TITLE: PROJECT OWNER: SHEET CONTENT: SHEET NO.:

Namaya Construction DRAWING AND SPECIFICATIONS DULY SIGNED, STAMP OR SEALED AS INSTRUMENT OF SERVICE
ARE THE PROPERTIES AND DOCUMENTS OF THE ARCHITECT WHETHER THE OBJECT FOR WHICH THEY ARE

PROPOSED BUNGALOW RESIDENTIAL BUILDING MR. MACREEN ATENDIDO


S007
MADE IS AXECUTED OR NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON, WITHOUT THE WRITTEN
CENSENT OF THE ARCHITECT OR AUTHOR OF SAID DOCUMENTS TO DUPLICATE OR TO MAKE COPIES OF
CONSTRUCTION | DESIGNING | CONSULTANT
SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR OTHER PROJECTS OR BUILDING, WHETHER
EXECUTED PARTLY OR INCLUDED. TYPICAL STEEL TRUSS DETAILS
LOCATION:
PRC: PTR: C.T.C NO.: HOME ADDRESS:
PARAS ST., MAMBANGNAN, SAN LEONARDO, NUEVA ECIJA, 3102
SAN LEONARDO, NUEVA ECIJA PRESIDENTIAL DECREE TYPICAL BEAM DETAILS

13 28
0960 550 2523 | 0947 879 2832
VALIDITY: DATE ISSUED: DATE ISSUED:
[email protected] "PROTECTION AND INTELLECTUAL PROPERTY" NOVEMBER 14, 1972
POBLACION, SAN LEONARDO, NUEVA ECIJA, 3102
DATE APPROVED:
WORKS OF ART, ARCHITECT MODELS AND DESIGNS ARE CREATIVE WORK
TIN: PLACE: PLACE ISSUED:
DATE: JANUARY 5, 2024 (FRIDAY) AND CONSIDERED OR PART OF THE INTELLECTUAL PROPERTY OF THE AUTHOR DULY PROTECTED UNDER
PRESIDENTIAL DECREE 49.
DIMENSION REBARS SECTION
MARKS LEFT SUPPORT MID SPAN SUPPORT RIGHT SUPPORT SIDE BARS STIRRUPS 10mmØ REMARKS
b x d (mm) LEFT MID RIGHT
TOP BOTTOM TOP BOTTOM TOP BOTTOM

SB1 200 x 200 2-12mmØ 2-12mmØ 2-12mmØ 2-12mmØ 2-12mmØ 2-12mmØ 2-12mmØ 3 @ 50mm, 5 @ 100mm, 150mmO.C. MAX

TB1 200 x 300 2-16mmØ 2-16mmØ 2-16mmØ 2-16mmØ 2-16mmØ 2-16mmØ 2-16mmØ 3 @ 50mm, 5 @ 100mm, 150mmO.C. MAX

B1 200 x 300 4-16mmØ 2-16mmØ 2-16mmØ 4-16mmØ 4-16mmØ 2-16mmØ 2-16mmØ 3 @ 50mm, 5 @ 100mm, 150mmO.C. MAX

B2 200 x 350 4-16mmØ 2-16mmØ 2-16mmØ 4-16mmØ 4-16mmØ 2-16mmØ 2-16mmØ 6 @ 50mm, 5 @ 100mm, 150mmO.C. MAX

B3 250 x 400 5-16mmØ 2-16mmØ 2-16mmØ 5-16mmØ 5-16mmØ 2-16mmØ 2-16mmØ 7 @ 50mm, 5 @ 100mm, 150mmO.C. MAX

B4 300 x 400 5-16mmØ 2-16mmØ 2-16mmØ 5-16mmØ 5-16mmØ 2-16mmØ 2-16mmØ 7 @ 50mm, 5 @ 100mm, 150mmO.C. MAX

CB1 300 x 400 4-16mmØ 2-16mmØ 2-16mmØ 2-16mmØ 2-16mmØ 2-16mmØ 2-16mmØ 7 @ 50mm, 5 @ 100mm, 150mmO.C. MAX CANTILEVER

RB1 200 x 300 2-16mmØ 2-16mmØ 2-16mmØ 2-16mmØ 2-16mmØ 2-16mmØ 2-16mmØ 5 @ 50mm, 5 @ 100mm, 150mmO.C. MAX

CRB1 300 x 400 4-16mmØ 2-16mmØ 2-16mmØ 2-16mmØ 2-16mmØ 2-16mmØ 2-16mmØ 7 @ 50mm, 5 @ 100mm, 150mmO.C. MAX CANTILEVER

STB1 250 x 400 4-16mmØ 2-16mmØ 2-16mmØ 4-16mmØ 4-16mmØ 2-16mmØ 2-16mmØ 7 @ 50mm, 5 @ 100mm, 150mmO.C. MAX

S008 SCHEDULE OF R.C. BEAMS


1 1 SCALE 1:30 SI

REPUBLIC ACT 9266, : ARTICLE 2 SEC. 25(4)


CADD BY: REVISION: DATE:
ENGINEER: PROJECT TITLE: PROJECT OWNER: SHEET CONTENT: SHEET NO.:

Namaya Construction DRAWING AND SPECIFICATIONS DULY SIGNED, STAMP OR SEALED AS INSTRUMENT OF SERVICE
ARE THE PROPERTIES AND DOCUMENTS OF THE ARCHITECT WHETHER THE OBJECT FOR WHICH THEY ARE

PROPOSED BUNGALOW RESIDENTIAL BUILDING MR. MACREEN ATENDIDO


S008
MADE IS AXECUTED OR NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON, WITHOUT THE WRITTEN
CENSENT OF THE ARCHITECT OR AUTHOR OF SAID DOCUMENTS TO DUPLICATE OR TO MAKE COPIES OF
CONSTRUCTION | DESIGNING | CONSULTANT
SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR OTHER PROJECTS OR BUILDING, WHETHER
EXECUTED PARTLY OR INCLUDED.

LOCATION:
PRC: PTR: C.T.C NO.: HOME ADDRESS:
PARAS ST., MAMBANGNAN, SAN LEONARDO, NUEVA ECIJA, 3102 SCHEDULE OF R.C. BEAMS
SAN LEONARDO, NUEVA ECIJA PRESIDENTIAL DECREE

14 28
0960 550 2523 | 0947 879 2832
VALIDITY: DATE ISSUED: DATE ISSUED:
[email protected] "PROTECTION AND INTELLECTUAL PROPERTY" NOVEMBER 14, 1972
POBLACION, SAN LEONARDO, NUEVA ECIJA, 3102
DATE APPROVED:
WORKS OF ART, ARCHITECT MODELS AND DESIGNS ARE CREATIVE WORK
TIN: PLACE: PLACE ISSUED:
DATE: JANUARY 5, 2024 (FRIDAY) AND CONSIDERED OR PART OF THE INTELLECTUAL PROPERTY OF THE AUTHOR DULY PROTECTED UNDER
PRESIDENTIAL DECREE 49.
LENGTH WIDTH THICKNESS DEPTH GRAVEL
MARK C1 C2 C3 C4 MARK X Y DETAILS
(mm) (mm) (mm) (mm) THK

FOUNDATION TO
2/F

DIMENSION F1 1700 1700 300 1500 15-16mmØ 15-16mmØ 75 mm THK


250 x 350 300 x 350 300 x 350 300 x 350
(mm)
VERTICAL
6-16mmØ 6-16mmØ 8-16mmØ 10-16mmØ
BARS
LATERAL TIES 10mmØ 10mmØ 10mmØ 10mmØ

3@50mm, 3@50mm, 3@50mm, 3@50mm,


SPACING 5@100mm, REST 5@100mm, REST 5@100mm, REST 5@100mm, REST
@150mm @150mm @150mm @150mm

F2 1800 1800 350 1500 16-16mmØ 16-16mmØ 75 mm THK


2/F TO ROOF
BEAM

DIMENSION
200 x 300 300 x 350 200 x 300 300 x 350
(mm)
VERTICAL
6-16mmØ 6-16mmØ 6-16mmØ 8-16mmØ
BARS S009 SCHEDULE OF R.C. FOOTINGS
LATERAL TIES 10mmØ 10mmØ 10mmØ 10mmØ 2 3 SCALE 1:40 SI

3@50mm, 3@50mm, 3@50mm, 3@50mm,


SPACING 5@100mm, REST 5@100mm, REST 5@100mm, REST 5@100mm, REST CL
@150mm @150mm @150mm @150mm

1350
TOP OF THE ROOF BEAM

S009 SCHEDULE OF R.C. COLUMNS


1 3 SCALE 1:20 SI 3000

SPLICE ZONE (TYP.)


VERTICAL BARS
H/4

H
SPLICE ZONE (TYP.)
SECOND FINISH FLOOR LINE

FOOTING, COLUMN AND BEAM CONNECTION


CONCRETE

S009
H/3
3000

3 3 SCALE 1:100 SI
H

FINISH FLOOR LINE


VARIES

SEE THE SPACING SCHEDULE PER


CONCRETE BED COLUMN
400

100
50

GRAVEL BED
REPUBLIC ACT 9266, : ARTICLE 2 SEC. 25(4)
CADD BY: REVISION: DATE:
ENGINEER: PROJECT TITLE: PROJECT OWNER: SHEET CONTENT: SHEET NO.:

Namaya Construction DRAWING AND SPECIFICATIONS DULY SIGNED, STAMP OR SEALED AS INSTRUMENT OF SERVICE
ARE THE PROPERTIES AND DOCUMENTS OF THE ARCHITECT WHETHER THE OBJECT FOR WHICH THEY ARE

PROPOSED BUNGALOW RESIDENTIAL BUILDING MR. MACREEN ATENDIDO


S009
MADE IS AXECUTED OR NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON, WITHOUT THE WRITTEN
CENSENT OF THE ARCHITECT OR AUTHOR OF SAID DOCUMENTS TO DUPLICATE OR TO MAKE COPIES OF
CONSTRUCTION | DESIGNING | CONSULTANT
SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR OTHER PROJECTS OR BUILDING, WHETHER SCHEDULE OF R.C. COLUMN
EXECUTED PARTLY OR INCLUDED.

LOCATION:
PRC: PTR: C.T.C NO.: HOME ADDRESS:
PARAS ST., MAMBANGNAN, SAN LEONARDO, NUEVA ECIJA, 3102 SCHEDULE OF R.C. FOOTING
SAN LEONARDO, NUEVA ECIJA PRESIDENTIAL DECREE

15 28
0960 550 2523 | 0947 879 2832 FOOTING, COLUMN AND BEAM CONECTION
VALIDITY: DATE ISSUED: DATE ISSUED:
[email protected] "PROTECTION AND INTELLECTUAL PROPERTY" NOVEMBER 14, 1972
POBLACION, SAN LEONARDO, NUEVA ECIJA, 3102
DATE APPROVED:
WORKS OF ART, ARCHITECT MODELS AND DESIGNS ARE CREATIVE WORK
TIN: PLACE: PLACE ISSUED:
DATE: JANUARY 5, 2024 (FRIDAY) AND CONSIDERED OR PART OF THE INTELLECTUAL PROPERTY OF THE AUTHOR DULY PROTECTED UNDER
PRESIDENTIAL DECREE 49.
R.C. SLAB SCHEDULE
SHORT SPAN LONG SPAN
MARK THINKNESS STEEL DECK THK REMARKS
BENT BARS TEMP BARS STRAIGHT BARS BENT BARS TEMP BARS STRAIGHT BARS

S1 125 12mmØ @125mm 10mmØ @ 300mm 10mmØ @125mm 12mmØ @125mm 10mmØ @ 300mm 10mmØ @125mm 1mm TWO WAY

S2 125 12mmØ @125mm 10mmØ @125mm 10mmØ @ 300mm 10mmØ @125mm 1mm ONE WAY

12 mm Ø CONT BEND BARS @


MIDDLE STRIP ALONG SHORT SPAN
DIRECTION SPACED @125 mm O.C

10 mm Ø TEMP BARS 12 mm Ø CONT BEND BARS @

L/4
SPACED @ 300 mm O.C MIDDLE STRIP ALONG LONG SPAN
12 mm Ø CONT BEND BARS
ALONG LONG SPAN DIRECTION SPACED @150 mm O.C
SPACED @150 mm O.C ALONG
DIRECTION
SHORT SPAN DIRECTION

LONG SPAN DIRECTION

LONG SPAN DIRECTION


10 mm Ø TEMP BARS @ COLUMN

L/2
STRIP ALONG LONG SPAN
DIRECTION SPACED @ 300 mm O.C
SHORT SPAN DIRECTION

L/4
10 mm Ø TEMP BARS @ COLUMN
STRIP ALONG SHORT SPAN
DIRECTION SPACED @ 300 mm O.C
10 mm Ø STRAIGHT BARS @ COLUMN

S010 TYP SLAB DETAIL (ONE-WAY)(S2) STRIP


ALONG SHORT/LONG SPAN
DIRECTION 300 mm O.C
L/4 L/2 L/4
1 4 SCALE NTS
SHORT SPAN DIRECTION

SEE SCHEDULE S010 TYP SLAB DETAIL ( TWO-WAY )(S1)

100mm
FINISH FLOOR LINE
FINISH FLOOR LINE
2 4 SCALE NTS

300

STEEL WIRE MESH


200

0.100m
12mmØ RSB BOTHWAYS @300mm
O.C.

0.05m GRAVEL BEDDING 0.05m GRAVEL BEDDING


0.100m GRAVEL BEDDING

200 THK SAND FILLING

S010 DETAIL PLAN OF STAIR ON GRADE S010 SLAB ON GRADE DETAIL


3 4 SCALE NTS 4 4 SCALE NTS

REPUBLIC ACT 9266, : ARTICLE 2 SEC. 25(4)


CADD BY: REVISION: DATE:
ENGINEER: PROJECT TITLE: PROJECT OWNER: SHEET CONTENT: SHEET NO.:

Namaya Construction DRAWING AND SPECIFICATIONS DULY SIGNED, STAMP OR SEALED AS INSTRUMENT OF SERVICE
ARE THE PROPERTIES AND DOCUMENTS OF THE ARCHITECT WHETHER THE OBJECT FOR WHICH THEY ARE

PROPOSED BUNGALOW RESIDENTIAL BUILDING MR. MACREEN ATENDIDO


S010
MADE IS AXECUTED OR NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON, WITHOUT THE WRITTEN
CENSENT OF THE ARCHITECT OR AUTHOR OF SAID DOCUMENTS TO DUPLICATE OR TO MAKE COPIES OF TYPICAL SLAB DETAILS (ONE-WAY) (S2)
CONSTRUCTION | DESIGNING | CONSULTANT
SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR OTHER PROJECTS OR BUILDING, WHETHER
EXECUTED PARTLY OR INCLUDED. TYPICAL SLAB DETAIL (TWO-WAY)(S1)
LOCATION:
PRC: PTR: C.T.C NO.: HOME ADDRESS:
PARAS ST., MAMBANGNAN, SAN LEONARDO, NUEVA ECIJA, 3102
SAN LEONARDO, NUEVA ECIJA PRESIDENTIAL DECREE DETAIL PLAN OF STAIR ON GRADE

16 28
0960 550 2523 | 0947 879 2832
VALIDITY: DATE ISSUED: DATE ISSUED:
[email protected] "PROTECTION AND INTELLECTUAL PROPERTY" NOVEMBER 14, 1972 SLAB ON GRADE DETAIL
POBLACION, SAN LEONARDO, NUEVA ECIJA, 3102
DATE APPROVED:
WORKS OF ART, ARCHITECT MODELS AND DESIGNS ARE CREATIVE WORK
TIN: PLACE: PLACE ISSUED:
DATE: JANUARY 5, 2024 (FRIDAY) AND CONSIDERED OR PART OF THE INTELLECTUAL PROPERTY OF THE AUTHOR DULY PROTECTED UNDER
PRESIDENTIAL DECREE 49.
ROD SUSPENSION HANGER WITH
ADJUSTMENT SPRING DEPTH OF CEILING
12 mmØ NEGATIVE BARS @ 300mm TO REQUIRED DIMENSION
50 mm 12 mmØ TEMP. BARS @ 300mm O.C. 1200
O.C. B.W.
B.W. 400

1200

SLAB THK
400

400

400
BEAM DEPTH
1.0MM
STEEL DECK
DNSD-1/80,000 PSI

CONCRETE CONCRETE CONCRETE


BEAM BEAM BEAM

PRIMARY CHANNEL 1200


PREFORMED CLIP
S011 TYP. RC AND STEEL DECK CONNECTION 1200
2400

CEILING FURRING SECTION SPOT DETAIL


1 5 SCALE NTS FIBER CEMENT
CEILING BOARD

S011 ISOMETRIC CEILING DETAILS


'A' = COL STRIP MIDDLE STRIP 0.13 X 'B' 'B' = COL STRIP
4 5 SCALE NTS
0.25 L1 0.25 X 'A' 0.25 L1 0.25 L2 0.13 X 'B'
25mm CLEAR TOP BARS

T
ROD SUSPENSION HANGER 12mm x 38mm x 5m x 0.8mm
25mm CLEAR
BOTTOM BARS
LAP BOTTOM
WITH ADJUSTMENT SPRING THK.
BARS 150 mm MIN
AT 400mm O.C.
STD 180 HOOKS PLACE ALL COL STRIP REINFORCING WITHIN COL STRIP
EXCEPT STD 90 EXTERIOR SPAN = L1
HOOKS @ BEAMS INTERIOR SPAN = L2

TOP OF ROOF BEAM


1200 1200
BEAM BEAM
S011 TYPICAL SLAB SECTION (ONE WAY)

100
2 5 SCALE NTS METAL CARRYING CHANNEL (CEILING JOIST)
12mm x 38mm x 5m x 0.8mm THK.
AT 1200mm O.C.
METAL CARRYING CHANNEL (CEILING JOIST)
12mm x 38mm x 5m x 0.8mm THK.
0.13 X 'B'
AT 1200mm O.C.
'A' = COL STRIP MIDDLE STRIP 'B' = COL STRIP

0.25 L1 0.25 X 'A'

0.25 L1 0.25 L2 0.13 X 'B'


25mm CLEAR
TOP BARS S011 SECTION (CEILING)
T
BOTTOM BARS
25mm CLEAR
LAP BOTTOM
5 5 SCALE NTS
BARS 150 mm MIN
STD 180 HOOKS
EXCEPT STD 90
PLACE ALL COL STRIP REINFORCING WITHIN COL STRIP
HOOKS @ BEAMS
EXTERIOR SPAN = L1 INTERIOR SPAN = L2

S011 TYPICAL SLAB SECTION (TWO WAY)


3 5 SCALE NTS

REPUBLIC ACT 9266, : ARTICLE 2 SEC. 25(4)


CADD BY: REVISION: DATE:
ENGINEER: PROJECT TITLE: PROJECT OWNER: SHEET CONTENT: SHEET NO.:

Namaya Construction DRAWING AND SPECIFICATIONS DULY SIGNED, STAMP OR SEALED AS INSTRUMENT OF SERVICE
ARE THE PROPERTIES AND DOCUMENTS OF THE ARCHITECT WHETHER THE OBJECT FOR WHICH THEY ARE

PROPOSED BUNGALOW RESIDENTIAL BUILDING MR. MACREEN ATENDIDO


S011
MADE IS AXECUTED OR NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON, WITHOUT THE WRITTEN TYPICAL R.C. AND STEEL DECK CONNECTION
CENSENT OF THE ARCHITECT OR AUTHOR OF SAID DOCUMENTS TO DUPLICATE OR TO MAKE COPIES OF
CONSTRUCTION | DESIGNING | CONSULTANT
SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR OTHER PROJECTS OR BUILDING, WHETHER TYPICAL SLAB SECTION (ONE-WAY)
EXECUTED PARTLY OR INCLUDED.

LOCATION:
PRC: PTR: C.T.C NO.: HOME ADDRESS:
PARAS ST., MAMBANGNAN, SAN LEONARDO, NUEVA ECIJA, 3102 TYPICAL SLAB SECTION (TWO-WAY)
SAN LEONARDO, NUEVA ECIJA PRESIDENTIAL DECREE

17 28
0960 550 2523 | 0947 879 2832 ISOMETRIC CEILING DETAILS
VALIDITY: DATE ISSUED: DATE ISSUED:
[email protected] "PROTECTION AND INTELLECTUAL PROPERTY" NOVEMBER 14, 1972
POBLACION, SAN LEONARDO, NUEVA ECIJA, 3102
DATE APPROVED:
WORKS OF ART, ARCHITECT MODELS AND DESIGNS ARE CREATIVE WORK SECTION (CEILING)
TIN: PLACE: PLACE ISSUED:
DATE: JANUARY 5, 2024 (FRIDAY) AND CONSIDERED OR PART OF THE INTELLECTUAL PROPERTY OF THE AUTHOR DULY PROTECTED UNDER
PRESIDENTIAL DECREE 49.
12mmØ TOP BARS @ 150
12mmØ @ 150 mm O.C.
mm O.C.
12mmØ @ 150 mm O.C.
12mmØ RSB BOTHWAYS @ 150 mm

4 5 12mmØ
45
0
O.C.
12mmØ RSB BOTHWAYS @ 150 mm
10mmØ O.C.

200
WOOD HANDRAILINGS 300
10mmØ

12mmØ @ 150 mm O.C. 0


45 SC-1

150
C 12mmØ.
12mmØ.

S012 12mmØ RSB BOTHWAYS @ 200 mm


2 4 O.C.

200

200
1000 1000

S012 SECTION ELEVATION (LOWER)


S012 3 4 SCALE 1:50 SI
3 4

D DOWEL MATCH
WALL VERT. BARS

S012 STAIR PLAN


1 4 SCALE 1:50 SI

(DOWEL)
DIAMETER
12mmØ @ 150 mm O.C.

30 BAR
10mmØ
950 B1 45 Ld.
0 10mmØ
12mmØ (TYP.)
200

300 FLR. LEVEL


12mmØ @ 150 mm O.C.
45 12mmØ @ 150 mm O.C.
0

250
150

12mmØ TOP BARS @ 150


mm O.C.
12mmØ RSB BOTHWAYS @ 150 mm
O.C.
L/4 12mmØ RSB BOTHWAYS @ 150 mm
12mmØ BOT. BARS
O.C.
@ 225mm O.C.
SB SB 400 200

SC-1 S012 WALL FTG. INTERIOR WALLS


4 4 SCALE NTS

SCHEDULE OF WALL
MARK DETAIL

4" CHB w/ 10mmØ V tica ba s spcd. @ v 0.60m & 10mmØ H iz nta ba s spcd. @ v 3- a s
INTERIOR WALLS
S012 SECTION ELEVATION (UPPER) CHB

2 4 SCALE 1:50 SI
5" CHB w/ 10mmØ V tica ba s spcd. @ v 0.60m & 10mmØ H iz nta ba s spcd. @ v 3- a s
EXTERIOR WALLS
CHB

REPUBLIC ACT 9266, : ARTICLE 2 SEC. 25(4)


CADD BY: REVISION: DATE:
ENGINEER: PROJECT TITLE: PROJECT OWNER: SHEET CONTENT: SHEET NO.:

Namaya Construction DRAWING AND SPECIFICATIONS DULY SIGNED, STAMP OR SEALED AS INSTRUMENT OF SERVICE
ARE THE PROPERTIES AND DOCUMENTS OF THE ARCHITECT WHETHER THE OBJECT FOR WHICH THEY ARE

PROPOSED BUNGALOW RESIDENTIAL BUILDING MR. MACREEN ATENDIDO


S012
MADE IS AXECUTED OR NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON, WITHOUT THE WRITTEN
CENSENT OF THE ARCHITECT OR AUTHOR OF SAID DOCUMENTS TO DUPLICATE OR TO MAKE COPIES OF STAIR PLAN
CONSTRUCTION | DESIGNING | CONSULTANT
SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR OTHER PROJECTS OR BUILDING, WHETHER
EXECUTED PARTLY OR INCLUDED. SECTION ELEVATION (LOWER)
LOCATION:
PRC: PTR: C.T.C NO.: HOME ADDRESS:
PARAS ST., MAMBANGNAN, SAN LEONARDO, NUEVA ECIJA, 3102
SAN LEONARDO, NUEVA ECIJA PRESIDENTIAL DECREE SECTION ELEVATION (UPPER)

18 28
0960 550 2523 | 0947 879 2832
VALIDITY: DATE ISSUED: DATE ISSUED:
[email protected] "PROTECTION AND INTELLECTUAL PROPERTY" NOVEMBER 14, 1972 WALL FOOTING INTERIOR WALLS
POBLACION, SAN LEONARDO, NUEVA ECIJA, 3102
DATE APPROVED:
WORKS OF ART, ARCHITECT MODELS AND DESIGNS ARE CREATIVE WORK
TIN: PLACE: PLACE ISSUED:
DATE: JANUARY 5, 2024 (FRIDAY) AND CONSIDERED OR PART OF THE INTELLECTUAL PROPERTY OF THE AUTHOR DULY PROTECTED UNDER
PRESIDENTIAL DECREE 49.

You might also like