0% found this document useful (0 votes)
15 views

First Page

This document provides a concrete mix design report for a C20/25 class concrete to be used in the Sibiu Motorway By-Pass project in Romania. The report details the aggregates, cement, water, and additives to be used. Three trial mixes were tested with cement contents adjusted by +/- 7%. All mixes met the required workability. Compressive strength tests at 7 and 28 days confirmed the base mix design of 400 kg/m3 cement satisfied the C20/25 class requirements. Mix design (C) was selected as compatible with concreting operations.

Uploaded by

Alexe Florea
Copyright
© © All Rights Reserved
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
15 views

First Page

This document provides a concrete mix design report for a C20/25 class concrete to be used in the Sibiu Motorway By-Pass project in Romania. The report details the aggregates, cement, water, and additives to be used. Three trial mixes were tested with cement contents adjusted by +/- 7%. All mixes met the required workability. Compressive strength tests at 7 and 28 days confirmed the base mix design of 400 kg/m3 cement satisfied the C20/25 class requirements. Mix design (C) was selected as compatible with concreting operations.

Uploaded by

Alexe Florea
Copyright
© © All Rights Reserved
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 6

SUCURSALA SIBIU

TODINI SPA
CAPITALE SOCIALE
Euro 31.705.620 i.v.
00142 ROMA
VIA DEL SERAFICO 200
TEL 06/519951
FAX 06/5043427
Internet : www.todini.it
E-MAIL: [email protected]
SIBIU MOTORWAY BY-PASS
TRIB. ROMA: 10720/87
CCIAA ROMA 644647 CONTRACT B.P. 02
C.F. 08105460581
P.I. 01959721000

TODINI SPA
Sucursala Sibiu CONCRETE MIX DESIGN
Str. Stefan Cel Mare, nr. 195
550321 SIBIU, ROMANIA C20/25
Tel. +40 269 230225 - 230235
Fax +40 269 245829
[email protected]
LABORATORY MIX
Cod Unic R15470787
Reg. Com. J32/1151/30.07.2004 REPORT

Concrete Class: C20/25


Ø max aggregates = 31 mm
Cement type: II A-S 32.5R
Cement content = 400 kg/m3
Water/Cement Ratio = 0.5
Pag 1 din 4

C 04/10/2005 LAB MIX


B
A
Date Description Compiled (ME) Verified (QAM) Approved (PM)
Pag 2 din 4

TABLE OF CONTENTS

SUBJECT

1.0 GENERAL

2.0 AGGREGATES

3.0 CEMENT

4.0 WATER

5.0 ADDITIVE

6.0 MIX DESIGNS DETAILS

7.0 CONCLUSION

APPENDICES

1.0 Determinations to establish the concrete composition

2.0 Aggregate test results

3.0 Cement declaration of conformity

4.0 Compressive strength test results


Pag 3 din 4

1.0 GENERAL

Scope of this report is to assess and define, trough the evaluation of the results, a concrete mix
which satisfy the requirements given in Contract Specification and “Cod de practica pentru
executarea lucrarilor din beton si beton armat” indicativ NE 012-99.

The study is based on the results obtained during the concrete trial mixes carried out in the Site
Laboratory in 01/09/2005 and 06/09/2005.

2.0 AGGREGATES

The proposed aggregates to be used in concrete production are the following:


a) Coarse aggregate: Gravel
(2 classes: 7÷16, 16÷31)
b) Fine aggregates: Fine and Coarse Sand
(2 classes: 3÷7, 0÷3)

The source of gravel aggregates is the approved quarry of AVRIG.


(Reference approval letter 3813/SO/1340/UP/0389 dated 27.05.2004)

Grading and specific gravity test results are collected in appendix 2.0.

3.0 CEMENT

The cement used is the following:


Cement complying with SR EN 197-1 type II A-S 32.5 R.

The source of cement is the approved factory of HOLCIM - ALESD


(Reference approval letter 3813/SO/1340/UP/0159 dated 06.03.2004).

Cement certificates “DECLARATIE DE CONFORMITATE” of supplier are enclosed in


appendix 3.0

4.0 WATER

The water used in the mix design and for concrete production is potable water and therefore
tests are not required (ref. STAS 790-84).

5.0 ADDITIVE
Pag 4 din 4

The admixtures used are the following:

Plastifiant BV3M

6.0 MIX DESIGNS DETAILS

6.1 General

The mix design can be found in appendix 1.0.

6.2 Workability

All the mixes showed workability that complies with the limits of class T4 (120  20 mm)

Mix Reference Slump (mm)


29 - Reteta de baza 140
29 + 7% kg cement 130
29 – 7% kg cement 140

6.3 Compressive strength

7 days
Serial Average
Average
Mix number I II III IV V VI Density
N/mm2
cubes g/cm3
29-C20/25
Reteta de baza 847 23.1 22.7 22.9 23.6 23.1 25.3 23.5 2442
29-C20/25
+7% kg cement 856 25.8 25.6 26.2 26.9 25.3 26.2 26.0 2441
29-C20/25
-7% kg cement 848 21.5 21.8 22.7 23.1 20.9 21.5 21.9 2433

28 days
Serial Average
Average
Mix number I II III IV V VI Density
N/mm2
cubes g/cm3
29-C20/25
Reteta de baza 847 34.7 34.2 34.7 33.3 35.1 34.7 34.5 2429
29-C20/25
+7% kg cement 856 38.0 41.5 41.8 38.7 39.1 39.5 39.8 2431
29-C20/25
-7% kg cement 848 33.8 33.8 32.4 33.8 33.3 33.8 33.5 2399

Tests results are collected in appendix 5.0


Pag 5 din 4

7.0 CONCLUSION

For concrete class C20/25 the mixes 28 are compatible with the concreting operation and with
the requirements of NE 012-99.

Variant (C) is the chosen mix design.