0% found this document useful (0 votes)
51 views7 pages

Annexure C

This document contains calculations for across wind bending moments in the x and y directions of a building located in Mumbai. It provides structural dimensions and parameters used in the calculations including height, breadth, time periods, wind speeds, and load factors. The results determine the design peak base bending moments of 40136.26 kNm in the x direction and 60681.58 kNm in the y direction. It also includes a table with story-wise wind loads.

Uploaded by

Jai Thakkar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
51 views7 pages

Annexure C

This document contains calculations for across wind bending moments in the x and y directions of a building located in Mumbai. It provides structural dimensions and parameters used in the calculations including height, breadth, time periods, wind speeds, and load factors. The results determine the design peak base bending moments of 40136.26 kNm in the x direction and 60681.58 kNm in the y direction. It also includes a table with story-wise wind loads.

Uploaded by

Jai Thakkar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

ANNEXURE-C

ACROSS WIND CALCULATIONS

SUBMITTED BY
JW CONSULTANTS LLP
SAI RADHE, OFFICE NO.201,
2ND FOOR, 100 KENNEDY ROAD,
BEHIND HOTEL LE MERIDIEN,
PUNE-411001

Page 1 of 7
CONTENTS

1 ACROSS WIND CALCULATIONS IN X DIRECTION 3


2 ACROSS WIND CALCULATIONS IN Y DIRECTION 5

Page 2 of 7
1. ACROSS WIND IN X DIRECTION

THE ACROSS WIND DESIGN PEAK BASE BENDING MOMENT IN X DIRECTION (MCX)

Total height of main structure of the building in


H 64.9
= meters above Ground level = m
B = Breadth of a structure in the horizontal plane normal to wind direction = 27.125 m
Maximum base dimension of building in meters
D 54.20
= In a direction parallel to the applied wind force. = m
Time period of building /structure in along wind direction
Tx 1.984
= (1ST dispalced Mode) = Sec
fax = l/T = 0.504 Cyc/Sec
Peak factor for resonant response
gh 3.87390607
= √[2ln(3600Xfax)] =
Damping Coefficient
β 0.02
= Bolted Steel/RCC Structure =
probability factor(risk coefficient)
k1 1
= =
terrain roughness and height factor
k2 0.727
= =
topography factor
k3 1
= =
importance factor for cyclonic region
k4 1
= All other structures =
Vb = Regional wind basic speed, for Mumbai = 39 m/s
Design Hourly mean wind speed at height z
Vhd = 28.353
Vhd = Vb k1 k2 k3 k4 = m/s
wind pressure at height z
ph = 482.335565
0.60 Vhd2 = N/m2
k = a mode shape power exponent = 1
Vhd/fcb = Vhd/fcb = 2.07381943
Ih,i = Turbulence intensity at height 2/3rd h in terrain category i = 0.18987918

Page 3 of 7
Category 3
Cfs = force spectrum coefficient (fig. 10/11- IS 875(Part 3:2015)) 0.0009
= 40136257 Nm
Mcx The across wind design peak base bending moment
= 40136.257 kNm
Fz,H = across wind load distribution on building = 28.587009

Page 4 of 7
1. ACROSS WIND IN Y DIRECTION

THE ACROSS WIND DESIGN PEAK BASE BENDING MOMENT IN Y DIRECTION (MCY)

Total height of main structure of the building in


H = 64.9
= meters above Ground level m
B = Breadth of a structure in the horizontal plane normal to wind direction = 54.2 m
Maximum base dimension of building in meters
D = 27.125
= In a direction parallel to the applied wind force. m
Time period of building /structure in along wind direction
Ty = 1.578
= (2ND dispalced Mode) Sec
fay = l/T = 0.634 Cyc/Sec
Peak factor for resonant response
gh = 3.93256428
= √[2ln(3600Xfay)]
Damping Coefficient
β = 0.02
= Bolted Steel/RCC Structure
probability factor(risk coefficient)
k1 = 1
=
terrain roughness and height factor
k2 = 0.727
=
topography factor
k3 = 1
=
importance factor for cyclonic region
k4 = 1
= All other structures
Vb = Regional wind basic speed, for Mumbai = 39 m/s
Design Hourly mean wind speed at height z
Vhd = = 28.353
Vhd = Vb k1 k2 k3 k4 m/s
wind pressure at height z
pz = = 482.335565
0.60 Vhd2 N/m2
k = a mode shape power exponent = 1
Vhd/fcb = Vhd/fcb = 0.82548033
Ih,i = Turbulence intensity at height 2/3rd h in terrain category i = 0.18987918

Page 5 of 7
Category 3
Cfs = force spectrum coefficient = 0.0005
= 60681582.1 Nm
Mcy = The across wind design peak base bending moment
= 60681.5821 kNm
Fz,H = across wind load distribution on building = 43.2203975

Tx 1.984
Ty 1.578
Vb 39
h 64.900
Cf 1.25
Dx 54.20
Dy 27.13
β 0.02
Mcx 40136.26
Mcy 60681.58

Page 6 of 7
Cum
Story Height Height AWYX AWXY
Height
TERRACE 2.95 2.95 64.900 42.166 63.750
21 2.95 2.95 61.950 80.498 121.705
20 2.95 2.95 59.000 76.665 115.909
19 2.95 2.95 56.050 72.832 110.114
18REFUGE 2.95 2.95 53.100 68.999 104.318
17 2.95 2.95 50.150 65.165 98.523
16 2.95 2.95 47.200 61.332 92.727
15 2.95 2.95 44.250 57.499 86.932
14 2.95 2.95 41.300 53.666 81.136
13REFUGE 2.95 2.95 38.350 49.832 75.341
12 2.95 2.95 35.400 45.999 69.546
11 2.95 2.95 32.450 42.166 63.750
10 2.95 2.95 29.500 38.333 57.955
9 2.95 2.95 26.550 34.499 52.159
8 REFUGE 2.95 2.95 23.600 30.666 46.364
7 2.95 2.95 20.650 26.833 40.568
6 2.95 2.95 17.700 23.000 34.773
5 2.95 2.95 14.750 19.166 28.977
4 2.95 2.95 11.800 15.333 23.182
3 2.95 2.95 8.850 11.500 17.386
2 2.95 2.95 5.900 7.667 11.591
1 2.95 2.95 2.950 3.833 5.795