Calculation of Height of The Siphon System

The document summarizes the calculation of pressure losses for a pumping system transporting water. It details the system requirements of transporting 1200 l/s of water through 150 meters of 1050mm diameter piping. It then lists the pressure losses associated with different pipe fittings such as elbows, tees, valves, and changes in pipe diameter. The total pressure loss is calculated to be 0.398 meters.

Uploaded by

Hsein Wang
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
179 views

Calculation of Height of The Siphon System

The document summarizes the calculation of pressure losses for a pumping system transporting water. It details the system requirements of transporting 1200 l/s of water through 150 meters of 1050mm diameter piping. It then lists the pressure losses associated with different pipe fittings such as elbows, tees, valves, and changes in pipe diameter. The total pressure loss is calculated to be 0.398 meters.

Uploaded by

Hsein Wang
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 2

Pumping System Calculation for : Pandan I Pumping Station Project Ref:

Calcs by: Thomas Thein Date: 7-Aug-07 Checked by: Date:


System details
Pumped Fluid Water
Kinematic Viscosity 0.000000784 m2/s at 32 deg C
Required duty flow 1200.00 l/s
Pumps Running 1
Pipe Details Main
Header
Pumps Contributing 1
Flow in Section l/s 1200 0 0 0
Length of Section m 150 0
Internal Diameter mm 1050
Flow velocity m/s 1.39 0.00 0.00 0.00
Velocity Head m 0.098 0.000 0.000 0.000
Roughness ks, mm 1.50
Pipework Friction Loss m 0.30 0.00 0.000 0.000
Fitting details K-value No Loss No Loss No Loss No Loss No Loss No Loss
Entry
Sharp edged 0.50 0.000 0.000 0.000 0.000 0.000 0.000
Re-entrant 0.80 0.000 0.000 0.000 0.000 0.000 0.000
Rounded 0.25 0.000 0.000 0.000 0.000 0.000 0.000
Bellmouthed 0.05 1 0.005 0.000 0.000 0.000 0.000 0.000

Bends
Elbow (R/D < 1) 22.5 deg 0.20 0.000 0.000 0.000 0.000 0.000 0.000
45 deg 0.40 0.000 0.000 0.000 0.000 0.000 0.000
90 deg 1.00 0.000 0.000 0.000 0.000 0.000 0.000
Short Radius (R/D = 1 - 2) 22.5 deg 0.15 0.000 0.000 0.000 0.000 0.000 0.000
45 deg 0.30 2 0.059 0.000 0.000 0.000 0.000 0.000
90 deg 0.75 0.000 0.000 0.000 0.000 0.000 0.000
Long Radius (R/D = 2 - 7) 22.5 deg 0.10 0.000 0.000 0.000 0.000 0.000 0.000
45 deg 0.20 0.000 0.000 0.000 0.000 0.000 0.000
90 deg 0.40 0.000 0.000 0.000 0.000 0.000 0.000
Swept Bend (R/D = 8 - 50) 22.5 deg 0.05 0.000 0.000 0.000 0.000 0.000 0.000
45 deg 0.10 0.000 0.000 0.000 0.000 0.000 0.000
90 deg 0.20 0.000 0.000 0.000 0.000 0.000 0.000
Mitred Elbow
22.5 deg 2 piece 0.15 0.000 0.000 0.000 0.000 0.000 0.000
30 deg 2 piece 0.20 0.000 0.000 0.000 0.000 0.000 0.000
45 deg 2 piece 0.30 0.000 0.000 0.000 0.000 0.000 0.000
60 deg 2 piece 0.65 0.000 0.000 0.000 0.000 0.000 0.000
60 deg 3 piece 0.25 0.000 0.000 0.000 0.000 0.000 0.000
90 deg 2 piece 1.25 0.000 0.000 0.000 0.000 0.000 0.000
90 deg 3 piece 0.50 0.000 0.000 0.000 0.000 0.000 0.000
90 deg 4 piece 0.30 0.000 0.000 0.000 0.000 0.000 0.000
Sudden Enlargements
Inlet : Outlet 4:5 0.15 0.000 0.000 0.000 0.000 0.000 0.000
3:4 0.20 0.000 0.000 0.000 0.000 0.000
2:3 0.35 0.000 0.000 0.000 0.000 0.000 0.000
1:2 0.60 1 0.059 0.000 0.000 0.000 0.000 0.000
1:3 0.80 0.000 0.000 0.000 0.000 0.000 0.000
>1:5 1.00 0.000 0.000 0.000 0.000 0.000 0.000
Sudden Contractions
Inlet : Outlet 5:4 0.15 0.000 0.000 0.000 0.000 0.000 0.000
4:3 0.20 0.000 0.000 0.000 0.000 0.000 0.000
3:2 0.30 0.000 0.000 0.000 0.000 0.000 0.000
2:1 0.35 0.000 0.000 0.000 0.000 0.000 0.000
3:1 0.45 0.000 0.000 0.000 0.000 0.000 0.000
>5:1 0.50 0.000 0.000 0.000 0.000 0.000 0.000
Commercial Tapers
Flow to small end 0.10 0.000 0.000 0.000 0.000 0.000 0.000
Flow to Large End
Inlet : Outlet 4:5 0.10 0.000 0.000 0.000 0.000 0.000 0.000
3:4 0.10 0.000 0.000 0.000 0.000 0.000 0.000
2:3 0.15 0.000 0.000 0.000 0.000 0.000 0.000
1:2 0.45 0.000 0.000 0.000 0.000 0.000
Tees
Through Flow 0.05 0.000 0.000 0.000 0.000 0.000 0.000
Flow to/from Branch Sharp 1.20 0.000 0.000 0.000 0.000 0.000 0.000
Flow to/from Branch Swept 0.80 0.000 0.000 0.000 0.000 0.000 0.000
Angle Branch
Through Flow 0.35 0.000 0.000 0.000 0.000 0.000 0.000
Flow to/from Branch 30 deg 0.40 0.000 0.000 0.000 0.000 0.000 0.000
Flow to/from Branch 45 deg 0.60 0.000 0.000 0.000 0.000 0.000 0.000
Flow to/from Branch 90 deg 0.80 0.000 0.000 0.000 0.000 0.000 0.000
Exit
Sudden 1.00 0.000 0.000 0.000 0.000 0.000 0.000
Bellmouth 0.20 0.000 0.000 0.000 0.000 0.000 0.000
Valves
Gate Valve Open 0.12 0.000 0.000 0.000 0.000 0.000 0.000
25% closed 1.00 0.000 0.000 0.000 0.000 0.000 0.000
50% closed 6.00 0.000 0.000 0.000 0.000 0.000 0.000
Globe Valve Open 10.00 0.000 0.000 0.000 0.000 0.000 0.000
Air vent valve Open 5.00 0.000 0.000 0.000 0.000 0.000 0.000
Butterfly Valve Open 0.80 0.000 0.000 0.000 0.000 0.000 0.000
Diaphragm Valve Open 2.00 0.000 0.000 0.000 0.000 0.000 0.000
Ball valve Open 0.00 0.000 0.000 0.000 0.000 0.000 0.000
Non-return Valves
Swing Check 1.50 0.000 0.000 0.000 0.000 0.000 0.000
Reflux valve 1.00 0.000 0.000 0.000 0.000 0.000 0.000
Wafer Check 1.00 0.000 0.000 0.000 0.000 0.000 0.000
Specials
Orifice 9.96 0.000 0.000 0.000 0.000 0.000 0.000
Nozzle 2.00 0 0.000 0.000 0.000 0.000 0.000 0.000
Flowmeter 5.00 0.000 0.000 0.000 0.000 0.000 0.000
0.000 0.000 0.000 0.000 0.000 0.000
0.000 0.000 0.000 0.000 0.000 0.000
0.000 0.000 0.000 0.000 0.000 0.000
0.000 0.000 0.000 0.000 0.000 0.000
0.000 0.000 0.000 0.000 0.000 0.000

Fittings Loss 0.122 0.000 0.000 0.000 0.000 0.000

Total Section Losses 0.425 0.000 0.000 0.000 0.000 0.000


Total System Loss 0.42 m
Calculation of height of Siphon System
Velocity Head Loss Hv = 0.10 m
Vapour Pressure Pv = 0.4798 m
Friction Loss in Pipeline Hp = 0.42 m
(at 32 Degree C)
Atmospheric Pressure Patm = 10.133 m
Therefore highest point
The required height of
Siphon System h= Patm-(Pv+1.5Hv+Hp) L= 150
resrvoir h
h= 9.08 m
Actually use 75 % to 80% of calculated value

h= 6.81 m pump discharge


The height of the siphon system is 6.81 meter from high water level.