You are on page 1/ 2

Consultant Employer Contractor

P OWER
POWERCON PLC

SODDO JUNCTION (DIMTU) - BILATE MILITARY TRAINING CENTER

Determining Liquid Limit, Plastic Limit, Plasticity Index and Calassification of Soil
Test Method : AASHTO T 89, T 90 & M 145

Coordinate E-395073 N-746696 Sample Taken From: 2m depth


Material Type: Foundation Date Sampled: 8/3/2023
Sampling Station: BH 1 Represented Section: BH 1
Visual Description: Dark Brown CLAYEY Soil Date Tested: 8/9/2023
Tested By: consultant Apparatus: Casagrande

LIQUID LIMIT PLASTIC LIMIT


Test No 1 2 3 4 1 2
Container No. 25 4 28 A-22 14
Number of blows 35 24 15
Wt. of Wet soil + con (g) 40.31 34.75 38.22 15.62 16.63
Wt. of Dry soil + con (g) 32.42 28.24 29.45 14.02 14.70
Wt. of container (g) 19.79 18.07 16.18 9.12 8.92
Wt. of water (g) 7.89 6.51 8.77 1.60 1.93
Wt. of Dry soil (g) 12.63 10.17 13.27 4.90 5.78
Moisture Content (%) 62.47 64.01 66.09 32.65 33.39
AVERAGE
PL 33.02
Moisture Content, %

LIQUID LIMIT (LL) : 64


PLASTIC LIMIT (PL) : 33
PLASTICITY INDEX (PI) : 31

67

Wt. Before washing (gm)= 688 66


Sieve sizes (mm) Wt. %
retained retained %pass 65
(gm)
2 8.0 1.2 99 64
0.425 16.0 2.3 97
0.075 78.0 11.3 85 63
pan

62
1 No of blows 10 100
AASHTO Classification : A-7-5
GI 31.0