0% found this document useful (0 votes)
112 views4 pages

CROUZET - M3 - FBD Connection Guide

This document provides guidelines for connecting CROUZET M3 PLCs to HMI devices using RS-232 serial communication. It includes recommended HMI settings for the PLC connection as well as details on device addressing, wiring diagrams, and notes.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
112 views4 pages

CROUZET - M3 - FBD Connection Guide

This document provides guidelines for connecting CROUZET M3 PLCs to HMI devices using RS-232 serial communication. It includes recommended HMI settings for the PLC connection as well as details on device addressing, wiring diagrams, and notes.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

PLC Connection Guide

CROUZET M3 (FBD)

HMI Setting:
Parameters Recommended Options Notes
PLC type CROUZET M3 (FBD)
PLC I/F RS232
Baud rate 115200
Data bits 7
Parity Even
Stop bits 1
PLC sta. no. 1
*Support communications between HMI and PLC in pass-through mode
*Set LW-9903 to 2 to enhance the speed of download/upload PLC program in
pass-through mode

Device Address:
Bit/Word Device type Format Range Memo
B I DD 1 ~ 99 Input
B SLI_Bit DDh 10 ~ 24f Serial link input
B SLO_Bit DDh 250 ~ 48f Serial link output (read only)
B State D 1 State in PLC (read only)
W AI DD 1 ~ 99 Analogy input (default: 1 ~ 4)
W SL_IN DD 1 ~ 24 Serial link input
W SL_OUT DD 25 ~ 48 Serial link output (read only)
W Time D 1~6 Time & Day*
W Order D 1 Command** (write only)
W ID_Table DD 1 ~ 22
* address 1: second, address 2 : minute, address 3 : hour , address 4 : day, address 5 :
month, address 6 : year. The value range for “Year” is 0~99, entering “0” represents year
2000, entering “99” represents year 2099.
** run mode write 2, stop mode write 1.
PLC Connection Guide

Wiring Diagram:
CROUZET M3: RS-232 9P D-Sub (Diagram 1 ~ Diagram 4)
Diagram 1
cMT Series cMT3071 / cMT3072 / cMT3090 / cMT3103 / cMT3151

eMT Series eMT3070 / eMT3105 / eMT3120 / eMT3150

MT-iE MT8070iE / MT6070iE / MT8100iE / MT8121iE / MT8150iE /


MT8071iE / MT6071iE / MT8072iE / MT6072iE / MT8073iE /
MT8101iE / MT8102iE / MT8103iE

MT-XE MT8121XE / MT8150XE / MT8090XE / MT8092XE

MT-iP MT6103iP / MT8102iP

HMI PLC
COM1 RS232
RS232 9P D-Sub
9P Female (Extension cable)

Rx 2 2 TX
Tx 3 3 RX
GND 5 5 GND
RTS 7 4 DTR
PLC Connection Guide

Diagram 2
cMT Series cMT-SVR / cMT-G01 / cMT-G02 / cMT-HDM / cMT-FHD

mTV mTV

HMI PLC
COM1 RS232
RS232 9P D-Sub
9P Female (Extension cable)

Rx 2 2 TX
Tx 3 3 RX
GND 5 5 GND
0V External Power Supply
+5V External Power supply 4 DTR

Diagram 3
MT-iE MT8050iE / MT8053iE

MT-iP MT6051iP / MT8051iP

HMI PLC
COM1 RS232
RS232 9P D-Sub
9P Female (Extension cable)

Rx 9 2 TX
Tx 6 3 RX
GND 5 5 GND
TX+ 4 4 DTR
PLC Connection Guide

Diagram 4
MT-iP MT6071iP / MT8071iP

HMI PLC
COM1 RS232
RS232 9P D-Sub
9P Female (Extension cable)

Rx 9 2 TX
Tx 6 3 RX
GND 5 5 GND
RTS 7 4 DTR

(3m serial link cable)


Note: Please use 3m serial link cable
(Accessories from Millenium 3) and extension
cable (as shown) to communicate with HMI
series.

You might also like