Festo
Festo
I/O terminal
Design The terminals for 8 inputs and 8 outputs are combined in a basic unit. In addition,
distributor terminals are provided for 0 V and 24 V for the supply of sensors and
actuators. The base unit can be clipped onto top-hat rails. All contact points and the
current supply are linked to the 24-pin plug. The I/O terminal is connected to the
control cabinet by means of an I/O cable, which is not part of the scope of delivery
(Order No. 34031).
Function The I/O terminal provides 8 inputs and 8 outputs on screw terminals. 24 LEDs are
available for status display to indicate the status of the I/Os.
Number of terminals 0 V 22
Number of terminals 24 V 12
PIN 1 O0
PIN 2 O1
PIN 3 O2
PIN 4 O3
PIN 5 O4
PIN 6 O5
PIN 7 O6
PIN 8 O7
PIN 9 24 VA
PIN 10 24 VA
PIN 11 0 VA
PIN 12 0 VA
PIN 13 I0
PIN 14 I1
PIN 15 I2
PIN 16 I3
PIN 17 I4
PIN 18 I5
PIN 19 I6
PIN 20 I7
PIN 21 24 VB
PIN 22 24 VB
PIN 23 0 VB
PIN 24 0 VB
Pin assignment
Note The inputs of the I/O terminal can be switched for the connection of either positive
switching (PNP) or negative switching (NPN) sensors via two slide switches.
Design A relay and an electronic current limiter have been integrated on a circuit board. The
circuit board can be fitted via the attachments on the reverse side. Electrical
connection is effected via screw terminals.
Function The device limits the surge current to a maximum of 2A the moment it is switched
on. Otherwise, the module operates in the same way as a relay.
Note This module must only be used to operate consuming devices with a maximum static
current requirement of 1A. The current limiting effect must not be used for the
continuous current limiting of a consuming device.
24V
SPS
0V 0V
IN 24V OUT 0V
0V
Connection diagram
Control voltage 24 V DC
Current 1.0 A
Current limitation 2W
Description Pressure gauges are used to measure and indicate pressure values at pneumatic
control systems.
Pressure gauges may not be loaded to more than ¾ of their full scale value during
continuous operation.
Materials information
connecting thread Brass
housing ABS
viewing window PS
Function Piping of process engineering systems is quick, reliable and leak-proof using the
piping and push-fit connector system. The individual components of the piping
system are:
Straight piping sections
available in different lengths Order No. 304518
Blanking plug Order No. 170704
Push-in T-connector (see above) Order No. 170702
Push-in L-connector 90° (see above) Order No. 690590
Push-in L-connector 90° (see above) Order No. 170701
Hand lever valve (see above.) Order No. 170703
Design The piping system consists of pipes and push-fit connectors made of plastic.
Operating characteristics
Cold water system 20 °C/10 bar
Hot water system 65 °C/7 bar
Central heating system 82 °C/4 bar
Second seal
Plug-in mark
Dismantling:
– Unscrew the screw cap until a narrow gap is created and the two arrows snap
into the opposite position. Press back and hold the retaining element using your
fingers or with the help of releasing tool. The pre-fitted piping can now be pulled
out.
Typical areas of application Recirculating pump for water, antifreeze compounds in heating systems for
motor vehicles, boats, caravans, etc.
Recirculating pump for fresh water cooling in vehicles.
All-purpose pump for applications where self-priming is not required.
Mounting instructions These pumps are standard intake centrifugal pumps and must be filled with the
pumping medium prior to commissioning.
These pumps must not be operated dry. A brief period of dry operation does not
damage the pump. Please note that if the pump is operated dry for more than
30 minutes, it will be rendered unusable. If run dry, a noise will become audible.
Important: This pump must always operate in the specified direction of rotation.
The pumps are designed for continuous operation and voltage fluctuations of ±20%.
They must not be used for waste water containing coarse dirt particles.
The pumps can be installed in any working position – horizontal or vertical. In order
to avoid the formation of air pockets, the pump outlet should be turned upwards in
the case of horizontal mounting or aligned so that it is positioned at the upper side
of the pump.
Design The pump is held within a clamping ring and is mounted onto a profile plate using
two screws and T-head nuts.
Note When in operation, note the polarity of the voltage applies. The cable connections
are colour coded:
Operating voltage Positive terminal red
Negative terminal black
O-ring EPDM
Magnet: Ferrite
Connection 20 mm (¾“)
Push-in connection for piping diameter, external 15 mm
Temperature range
Fluidt 40°C – 100°C
Environment 40°C – 70°C
Power 26 W
Dimensions:
Length 170 mm
Width 62 mm
Height 75 mm
Weight 0.53 Kg
Pressure and performance Pressure (bar) Delivery rate (l/min) Current at 24 V (A)
0.1 26 1.1
Symbol
Function The 2/2-way solenoid valve is a direct controlled valve. If electrical current is not
flowing through the coil, the valve is closed by spring power. There is no pilot
pressure necessary to open the valve.
Functional principle
In normal position the armature with seal is pressed from spring power on the valve
seat.
The medium reinforces the seal effect. Engaging the selenoid coil the armature is
lifted from the valve seat whereby it is released. The medium is possible to flow
unchecked from P to A. Deactivating the selenoid coil the clip presses on the
armature whereby the valve is locked.
Design The 2/2-way solenoid valve is mounted with plug connectors into the piping.
Assembly position The assembly position of the valve is in any direction, preferably vertical position.
Electrical connection Plug vanes to DIN 43650 A for a connector socket Type 2508.
Note For a firm attachment, a pipe clamp may be fitted in front and behind the valve.
Connection G 1/2
Power consumption 8W
Kv-Value (water, +20°C) 1,2 m3/h (measurement 1 bar valve input free
outlet
Protection class IP 54
Weight 0,415 kg
Subject to change
1 24 V (black)
2 Ground (black)
3 PE (gn/ge)
2
9 10 11 12 13 14 15
1... 8
Function The analogue terminal is an optimised terminal strip for the connection of analogue
sensors and actuators to a control unit (PLC, EasyPortDA, Simu-Box etc.) via 15 pin
Sub-D interfaces. A 15-pin cable (not included) with a core cross-section of 0.25 mm2
connects the analogue terminal parallel to the control unit. 4 analogue input signals
and 2 analogue output signals can be connected.
Number of pins 15
Dimensions
Length 45 mm
Width 65 mm
Height 42 mm
The function of the terminals is described in general in the allocation list and subject
to the function scope of the industrial controller.
Therefore please observe the notes regarding the connection procedure of the
controller.
OUT VO1 1
VO2 2
AGNDO 3
IN II2 4
II1 5
AGNDI 6
VI2 7
VI1 8
OUT IO2 9
IO1 10
IN II4 12
II3 13
VI4 14
VI3 15
U = Voltage
I = Current
E = Input
A = Output
GND = Earth
Function The Maxi-1Q-4-30 controller is a motor controller with speed adjustment for 24V DC
motors. It ensures the reliable switching on and off of motors.
In the off status, the dynamic braking is active. The IxR amplification can be adjusted
by means of a bridge between GND and terminal 3 (amplification 1) or terminal 4
(amplification 2).
+VCD GRD
Anschlussbelegung 0V +VCD
Start
R+ Ref. 10V
Externe potentiometer 10 k.
A2 n-setpoint
Speed setpoint adjustment
R- Ref. 0V
A1 Start
0V Earth
4 IxR amplification 2
3 IxR amplification 1
+ Supply voltage
1 Motor (+)
Motor connection
2 Motor (-)
- Earth
Speed 0V – V CC adjustable
Function The transparent liquid flowing-in in the direction of the arrow adopts a centrifugal
motion via the rotating body in the measuring chamber and directed onto the light-
weight, three-vane rotor. The speed of the rotor is proportional to flow and is sensed
contactlessly via the built-in optoelectronic infrared system (diode and photo
transistor).
The integral amplifier supplies a steady square-wave signal, whereby the signal level
is dependent on the applied supply voltage (8 – 24V DC). Thanks to the special
configuration of the rotor, any potential gas bubbles in the liquid (trapped air) are
not dispersed, but are transported with the liquid.
All sensor housing components in contact with media are made of polyvinylidene
fluoride (PVDF).
Design The flow sensor is to be fitted into piping with the help of adapters.
Note Design in use: B.S.P. (British Standard Pipe Thread = Abbreviation for
British pipe thread)
Note The polarity of the applied voltage is to be observed during operation. The cable
connections are colour coded:
Operating voltage Positive terminal white
Negative terminal green
Output signal Square wave signal brown
Electrical design
Current consumption 18 – 30 mA
Materials:
all components in contact with media PVDF
Seals Viton
Dimensions
Length 47 mm
Connecting thread G ½“
Sensor
Dimensions for B.S.P (British Standard Pipe Thread = Abbreviation for British pipe
thread) and N.P.T. (National Standard Taper Pipe Thread = American tapered pipe
thread.) design
A 12.7 mm
L 47 mm
D ½“
d 13 mm
Pressure sensor
Function The pressure measurement transducer uses ceramic measurement cell as sensor.
The electronics transduces the measured signal into output signals of 0…10 V.
Because of its robust design, this sensor is for use in rough industry environment as
well.
The maximum process temperature range must not exceed 100 °C.
Protection class IP 65
Process connection G½
Parts in contact with measured substance Ceramic, stainless steel, NBR-sealing ring
Temperature ranges
Process temperature (at max.
environment temperature of 50°C) -25 °C..+100 °C
Storage temperature -40 °C..+85 °C
permissible environment temperature -25 °C..85 °C
compensated temperature range -10 °C..55 °C
Temperature influence
on zero point ‹0,25 % f.E./10 K
on range ‹0,15 % f.E./10 K
Power supply
nominal voltage 24 V DC
voltage range 11 V DC..40 V DC
max. permissible voltage supply 40 V DC
Signal output
2-wire technology 4..20 mA
3-wire technology 0..20 mA or 0..10 V
Response time ‹ 3 ms
Load RLmax
Usup ply 11
0,02
Load at signal output 0..10 V › 2,5 kΩ
Subject to change
Subject to change
Technical diagram
Electrical connections
Function The round tank has a capacity of 3 l (effective operating capacity) and can be used
for liquids and solids.
The tank cover is provided with several holes with threaded connection for inflow
and for sensors. Holes not required are provided with a blanking plug.
A connector d40 is fitted at the lower end of the container for discharge.
Design The container is attached laterally to a profile column via brackets, using screws and
T-head screws and is then mounted to the profile plate.
Different design variants with different profile feet can be used within MPS-PA.
Tank, round
Function The operational principle of a capacitive proximity sensor is based on the evaluation
of a change in capacitance of a capacitor in an RC resonant circuit. If a material
approaches the proximity sensor, the capacitance of the capacitor increases. This
leads to a change in vibration response of the RC circuit which is then evaluated. The
change in capacitance depends mainly on the distance, dimensions and the
dielectric constants of the respective materials.
The proximity sensor has a PNP output, i.e. the signal line is switched to a positive
potential in the switched status. The switch is designed in the form of a normally
open contact. The connection of the load is effected between proximity sensor signal
output and earth.
A yellow light emitting diode (LED) indicates the switching status and the green light
emitting diode (LED) the ready status. The sensitivity of the sensor can be
individually adapted with the help of a small adjusting screw.
Design The capacity proximity sensor can be fitted in a mounting bracket using two locking
nuts. The proximity sensor is of cylindrical design and has an M 18x1 thread.
Note The polarity of the applied voltage is to be monitored during operation. The cable
connections are colour coded.
Parameter Value
Operating voltage
1 Positive terminal Brown
3 Negative terminal Blue
Connection diagram
Protection class IP 65
Materials
Front cap PTFE
Housing Brass, nickel-plated
Displays
Supply voltage LED Green
Switching element „ON“ LED Yellow
Weight 55 g
Dimensions
Function The device consists of a vertically arranged tapered glass tube opening at the top,
through which the fluid to be measured flows. A conical float within the tube is lifted
by the flow of liquid and kept afloat, if equilibrium exists between the downwards
directed weight of the float on the one hand and the upwards directed force of flow
and buoyancy force on the other.
The volumetric flow can be read off via an externally fitted scale and the float level
marking. Bevelled notches on the float cause the float to rotate and prevent any
jamming.
Design The flow meter downstream of the flow sensor is fitted with a metering tube made of
Trogamid –T, which is suitable for use with neutral or aggressive media. The
threaded connectors moulded at the ends of the meter tube are used to receive
valve fittings. O-rings embedded at the front ensure a reliable seal between the
meter tube and valve fitting without generating radial forces which could cause the
tube to burst.
The graduated scale printed on the meter tube is adjusted according to the
respective flow medium and indicates the flow volume in l/h or m³/h. Moulded
dovetailed groovess are provided to fit nominal value pointers, limit value and signal
devices.
Note The use of float flow sensors is limited to the measurement of small to medium
volumetric flow of low viscosity liquids without solid particles or of gas flow at low
pressures
Technical drawing 4
Materials
Meter tube Trogamid-T
Connecting piece PVC-U
Dimensions
Internal diameter x length 20 mm x 208 mm (L4)
Weight 0.12 Kg
Within a certain range the output signal is proportional to the signal duration of the
ultrasonic pulse.
The object to be detected can be of different materials. Neither shape or colour, nor
liquid or powdery condition, have any or only a minimal effect on detection. In the
case of an object with a smooth, even surface, the surface must be aligned vertically
to the ultrasonic beam.
In its factory condition, the output signal increases with growing distance between
sensor and the object to be measured.
Protection class IP 67
Weight Max. 67 g
Idle current I0 50 mA
Measuring range
programmed 48 – 270 mm
factory setting 50 – 300 mm
Characteristic curve
programmed Falling
factory setting Rising
Installation
Free spaces
Keep free space within distance "x" around the sound cone clear of interfering
objects. Angular misalignment of 3 applies for smooth surfaces.
Switching range
(Vendor settings)
Connection
Pin assignment:
1 24V (brown)
2 n. c.
3 0V (blue)
4 Analogue output (black)
f
U
Function The measuring transducer converts the measured value of the flow sensor into a
voltage within a range of 0 to 10 V. It is operated using a DC voltage of 24 V.
It can be plugged into the basic terminal block and simply removed using this again
by pulling out.
Current consumption 12 mA
Input
Square-wave frequency generator 0 – 1kHz
Signal level 6VSS – 30VSS
Peak time 3s
Output
Output signal 0 – 10 V
Output load 2k
Colour Grey
Note regarding The basic terminal block has a lateral inscription plate. It is equipped with
basic terminal block 2-wire terminals. Front wiring; connections: CAGE CLAMP connection
Degree of contamination 3
Nominal current 10 A
Weight 21.028 g
Colour Grey
Height 28 mm/1.1 in
Width 22 mm/0.866 in
Depth 50 mm/1.97 in