Brake - Control - 2 TKE
Brake - Control - 2 TKE
Operating Manual
Brake control 2
OPERATING MANUAL
Printer’s imprint
Printed in Germany
The right of reprint or reproduction, even in the case of only partly exploitation, is subject to
express, written permission of THYSSENKRUPP AUFZUGSWERKE GmbH.
Any reproduction, copying or storing in data processing machines in any form or by any
means without prior permission of THYSSENKRUPP AUFZUGSWERKE GmbH is
regarded as infringement of the current Copyright Act and will be prosecuted. Technical
modifications for reasons of improvement of the brake control or for reasons of improving
the safety standard are subject to decisions of THYSSENKRUPP AUFZUGSWERKE
GmbH without prior notice.
Preface
We are pleased that you decided to purchase a quality product from THYSSENKRUPP
Aufzugswerke GmbH.
This operating manual assists you in getting familiar with the connecting control for brake
magnets of lift drives – referred to as brake control below – and with its intended
possibilities of use. Important information concerning safety and hazards help you to safely
use the brake control as intended. The brake control is subject to technical alterations.
Table of contents :
1. Safety
1.1 Explanation of symbols used 6
1.2 General safety information 7
7. Maintenance
7.1 Replacing of brake control 2 21
8. Annex
8.1 Declaration of conformity 22
The following pictographs and designations are used in this operating manual:
Danger
This symbol draws attention to an extreme danger to
life or risk of injury to persons. Disregard of warning
means danger to life !
Danger
This symbol draws attention to an immediate
impending danger to life or risk of injury to persons
caused by electric current.
Warning notices must always be observed !
Warning
This smbol draws attention to an impending danger.
Disregard can cause injury to persons or extensive
damage to property.
Warning notices must always be observed!
Note
This symbol draws attention to important information
and instructions for operation. Disregard can lead to
damages, hazards or failures.
Inspection
This symbol draws attention to inspection sequence.
These inspection notices must be observed in any
case. Disregard can lead to injury to persons or
damage to property.
Organizational measures
The owner or the installer must provide the necessary personal protective
gear. All existing safety devices must be checked regularly in accordance
with the maintenance plan.
Use as intended
The brake control is designed in accordance with the state of the art and the
recognized safety regulations. The brake control shall only
• be used for its intended purpose
• be used only if safe operation is ensured
The brake control shall exclusively be used for connecting magnetic brakes
of lift drives. Any other use or any use exceeding the scope of the above
definitions is regarded as use outside of the intended purpose.
THYSSENKRUPP AUFZUGSWERKE cannot be hold liable for any damages
resulting from this and for any damages which are caused by any errors of
procedure.
Use within the scope of its intended purpose also comprises
• observance of all information of the operating manual
• fulfilment of the instructions applying to putting into service, installation
description and inspection and repair work.
In the case of incorrect adjustment and use there will be danger to life for the
user or third parties resp. impairment of the component or material property.
Failures which possibly impair the correct functioning are to be eliminated
immediately.
Fig. 1
Brake control 2 is designed for activating brake magnets of lift drives at low
rated currents of 0.25 – 1.25A
Configuration
Brake control 2 consists of control board, mains filter and terminals.
The components are mounted on a steel elbow and have a plexiglass cover
as a safety precaution against contacting current-carrying elements.
Mode of operation
A semi-controlled rectifier bridge generates the DC voltage for the brake
magnets. The rectifier bridge is controlled via phase control component.
A free-wheeling diode and a varistor suppressor circuit are provided at the
output of the rectifier bridge.
For compliance with the required EMC limit values an integrated mains filter
is used.
Information
• Immediately document the damage noticed (drawing, photograph,
description of damage).
• Send the respective documents immediately to ThyssenKrupp
Aufzugswerke GmbH.
Unpacking
Information
• Dispose packing equipment in accordance with environmental
standards or make it available for further use.
• Special transport aids and transport contrivances shall not be sent
back to THYSSENKRUPP AUFZUGSWERKE GMBH but remain at
the customer.
Intermediate storage
• If the assembly is not mounted directly after delivery, carefully store it at
a sheltered place and see to it that it is provided with a humidity-proof
covering.
• Do not store the assembly in the open air. Parts without surface coating
lack long-time preservation. Oxidized connections and contacts impair
the correct functioning of the device.
Environmental conditions
Information
Storage: the ambient temperature during storage is assumed to be
maintained between 0 °C to + 50°C.
Maximum relative humidity of air shall not exceed 90 % (no moisture or
icing)
Operation: the ambient temperature at the final site of the machine shall
be maintained between 0 °C to + 50 °C and the relative humidity of air
shall not exceed 70 % (no moisture, no icing).
4.1 Mounting
Dimensions- fastenings:
103
85
6
30
Drilled holes Ø
43
10
120
174
180
Fig. 2
How to connect
Attention: Before you start connecting the brake control, read the safety
information of chapter 1.2, in particular section „Use of brake control and
possible hazards“.
16 22 10 4 20 L N PE
Fig. 3
Examples of connection see figures 4 and 5
Mains filter
Mains filter
disconnection.
Position of jumpers X3/X5, LED H1/H3 and visible type fuse E1 on board
X3
H3 3
2
H1 1 321
X5
20
E1 10
22
16
Fig. 6
Installation instructions
Wiring has to be changed as described below if brake control 2 is to replace older braking
current supplies (BSV):
Note: position and function of the terminals described below see examples of
connection in fig. 4 and 5.
Installation instruction:
For installation instruction see chapter 5
(The assembly is factory-assessed)
See examples of connection for pole-changing (fig. 4) and variable-speed motors (fig.5).
73765 Neuhausen a. d. F.
Deutschland
Tel.: +49 7158/12-0
Fax: +49 7158/12-2585
E-Mail: [email protected]