Project Document Title Doc. No. Rev.
Sheet
TEST REPORT ON FENCING DESIGN - 0 1
1. SCOPE OF DESIGN
This calculation report refers to the Analysis and Design of Aluminium Fencing
2. CODE OF PRATICE
In accordance with the following AMERICAN STANDARD codes, Analysis and Designs were performed
as per
ASCE 07-05 - American Society of Civil Engineers, Minimum design loads for building and
Other structures.
-Specification of Aluminum Structures: Load and Resistance Factor Design
STAAD V8i SS5 - Version 20.07.10.41
3. REFERENCES
Input drawings:
TEST PROBLEM
4. MATERIALS
Aluminium alloy - 6061-T6
5. GEOMETRIC MODEL:
Project Document Title Doc. No. Rev. Sheet
TEST REPORT ON FENCING DESIGN - 0 2
ANNEXURE-I
(PRIMARY LOAD CALCULATIONS)
(Excel prints shall be taken in A4 size)
PROJECT Fencing DOCUMENT. NO. DATE DESIGNED DATE
CLINET Test REVISION DATE CHECKED DATE
0
CL. NO. Load calculation for Fencing REFERENCES
1.0 Dimensional Data
Length of panel = 3.00 m
Height of panel = 0.95 m
Member type = Flat sided
2.0 Live Load
Minmimum live load for handrails (concentrated) = 0.89 kN (any direction)
3.0 Wind Load
Basic Wind Speed , Vb = 45 m/s (for Dubai)
Importance factor = 1
Exposure category = B
Topographic factor = 1
Wind directionality factor = 0.85
Velocity pressure at 10m ht = 0.76 kN/m2
Velocity pressure exposure coefficient at 10m ht = 0.72
Force coeffficient for flat sided members = 1.60
Design pressure on members = 1.21 kN/m2
Wind load on 50mm side = 0.06 kN/m
Wind load on 25mm side = 0.03 kN/m
Project Document Title Doc. No. Rev. Sheet
TEST REPORT ON FENCING DESIGN - 0 3
ANNEXURE-II
(MEMBER DESIGN OUTPUT)
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref
By Date10-May-18 Chd
Client File Fence design.std Date/Time 10-May-2018 21:53
Utilization Ratio
Beam Analysis Design Actual Allowable Ratio Clause L/C Ax Iz Iy Ix
Property Property Ratio Ratio (Act./Allow.) (mm2) (mm4) (mm4) (mm4)
1 4.00X2.00RECTX.104WALL
4.00X2.00RECTX.104WALL
0.300 1.000 0.300 774.192 1.05E+6 353E+3 816E+3
2 4.00X2.00RECTX.104WALL
4.00X2.00RECTX.104WALL
0.232 1.000 0.232 774.192 1.05E+6 353E+3 816E+3
3 4.00X2.00RECTX.104WALL
4.00X2.00RECTX.104WALL
0.161 1.000 0.161 774.192 1.05E+6 353E+3 816E+3
4 4.00X2.00RECTX.104WALL
4.00X2.00RECTX.104WALL
0.090 1.000 0.090 774.192 1.05E+6 353E+3 816E+3
5 4.00X2.00RECTX.104WALL
4.00X2.00RECTX.104WALL
0.029 1.000 0.029 774.192 1.05E+6 353E+3 816E+3
6 4.00X2.00RECTX.104WALL
4.00X2.00RECTX.104WALL
0.072 1.000 0.072 774.192 1.05E+6 353E+3 816E+3
7 4.00X2.00RECTX.104WALL
4.00X2.00RECTX.104WALL
0.045 1.000 0.045 774.192 1.05E+6 353E+3 816E+3
8 4.00X2.00RECTX.104WALL
4.00X2.00RECTX.104WALL
0.023 1.000 0.023 774.192 1.05E+6 353E+3 816E+3
9 4.00X2.00RECTX.104WALL
4.00X2.00RECTX.104WALL
0.008 1.000 0.008 774.192 1.05E+6 353E+3 816E+3
10 4.00X2.00RECTX.104WALL
4.00X2.00RECTX.104WALL
0.000 1.000 0.000 774.192 1.05E+6 353E+3 816E+3
11 2.00X1.00RECTX.104WALL
2.00X1.00RECTX.104WALL
0.124 1.000 0.124 374.838 119E+3 38.5E+3 89.5E+3
12 2.00X1.00RECTX.104WALL
2.00X1.00RECTX.104WALL
0.124 1.000 0.124 374.838 119E+3 38.5E+3 89.5E+3
13 2.00X1.00RECTX.104WALL
2.00X1.00RECTX.104WALL
0.124 1.000 0.124 374.838 119E+3 38.5E+3 89.5E+3
14 2.00X1.00RECTX.104WALL
2.00X1.00RECTX.104WALL
0.124 1.000 0.124 374.838 119E+3 38.5E+3 89.5E+3
Print Time/Date: 11/05/2018 00:52 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 1 of 1
Project Document Title Doc. No. Rev. Sheet
TEST REPORT ON FENCING DESIGN - 0 4
ANNEXURE-III
(CONNECTION CHECKS)
PROJECT Fencing DOCUMENT. NO. DATE DESIGNED DATE
CLINET Test REVISION DATE CHECKED DATE
0
CL. NO. Connection design REFERENCES
1.0 Post Base anchor connection
Maximum Moment at base = 0.83 kNm
Maximum shear at base = 0.89 kN
Thickness of bottom plate = 8 mm
Width of plate in bending direction = 150 mm
Length of plate = 200 mm
Yield strength of plate = 240 Mpa
Thickness required for base plate = 10 mm> 8 (Revise thickness)
Tension in anchor bolt = 4.165 kN Assuming 25mm edge distance
Dia of bolt = 8 (assuming NA on other 2 bolts
Strength of bolt due to yielding 28.95 kN
Embedment depth = 100.00
Strength of bolt due to bond failure = 4.27 kN (sleeve not included
for simplicity)
(minimum edge distances are assumed so that concrete failure does not govern)
Weld b/w post and baseplate =
Size of weld = 2 mm
Width of tube = 100
Length of tube = 50
Moment of inertia of weld = 589167
Maximum bending moment at base =
Actual stress in weld (due to moment) = 70.6931 Mpa
Actual stress in weld (due to shear) = 2.96667 Mpa
= 0.9 Fy
Allowable strength of weld = 148.5 (tension) 0.6 Fexx
= 99 (shear) Fexx= 165 Mpa
Combined check = 0.51 < 1 OK
2.0 Horizontal tube connection
Dia of rivet = 5 mm (assuming 3/16in rivet
Shear resistance of rivet = 0.93 kN (from catalogue)
Total shear resistance of connection = 1.86 kN
Maximum shear at connection = 0.072 kN
=
=
=