PLC Questions and Answers
PLC Questions and Answers
Learn Instrumentation and Control Engineering. Inst Tools covers topics of Industrial
Instrumentation, PLC, DCS, SCADA, Field Instruments, Analyzers and so on.
https://instrumentationtools.com
om
s .c
ol
To
i on
at
nt
me
ru
st
In
a) Bill Gates
b) Dick Morley
c) Bill Landis
d) Tod Cunningham
a) General Motors
b) Allen Bradley
c) Square D
d) Modicon
InstrumentationTools.com
Instrumentation Tools
Learn Instrumentation and Control Engineering. Inst Tools covers topics of Industrial
Instrumentation, PLC, DCS, SCADA, Field Instruments, Analyzers and so on.
https://instrumentationtools.com
b) A temperature sensor is used to adjust the room temperature and maintain it at a set point.
c) A user starts the bottle filling machine, places the bottle on the conveyor belt to fill it with the
required liquid.
om
.c
d) The luggage system at the airport.
s
e) A factory that makes red pens and has no human employees.
ol
Answer : To
i on
at
nt
me
ru
st
4. The part that monitors the inputs and makes decisions in a PLC is the CPU.
In
a. True
b. False
a. Motor
b. Light
c. Valve
d. Sensor
a. Siemens
b. Mitsubishi
InstrumentationTools.com
Instrumentation Tools
Learn Instrumentation and Control Engineering. Inst Tools covers topics of Industrial
Instrumentation, PLC, DCS, SCADA, Field Instruments, Analyzers and so on.
https://instrumentationtools.com
c. Microsoft
d. ABB
a. Analog output
b. Digital output
om
.c
c. Analog input
s
d. Digital input
ol
8. In a PLC “I” is used for output and “Q” is used for input
To
on
a. True
i
b. False
at
a. True
st
b. False
In
10. To increase the number of inputs and outputs of the PLC, one can use expansion
modules.
a. True
b. False
InstrumentationTools.com
Instrumentation Tools
Learn Instrumentation and Control Engineering. Inst Tools covers topics of Industrial
Instrumentation, PLC, DCS, SCADA, Field Instruments, Analyzers and so on.
https://instrumentationtools.com
a. True
b. False
om
.c
a) The PLC rung output [-( )-] is a discrete output instruction or bit in memory.
s
b) Each rung of the ladder logic represents a logical statement executed in software – inputs on
ol
the right and outputs on the left.
To
c) Input and output instructions in ladder logic do not directly represent the switches and
on
actuators.
i
d) PLC input instructions are logical symbols associated with voltage at the input module
at
terminals.
nt
a) Ladder logic is a PLC graphical programming technique introduced in the last 10 years.
ru
b) A ladder logic program is hard to analyze because it is totally different when compared with
st
c) The number of ladder logic virtual relays and input and output instructions is limited
only by memory size.
d) The number of contacts for a mechanical relay is limited to number of coils on the relay.
a) The status of each input can be checked from one location and outputs can be forced on and
off.
b) All symbols in the RLL represent actual components and contacts present in the control
system.
d) Input (-| |-) and output (- ( ) -) instruction symbols in the ladder logic represent only data
values stored in PLC memory.
a) If a problem in a PLC module occurs, the module can be changed in a matter of minutes
InstrumentationTools.com
Instrumentation Tools
Learn Instrumentation and Control Engineering. Inst Tools covers topics of Industrial
Instrumentation, PLC, DCS, SCADA, Field Instruments, Analyzers and so on.
https://instrumentationtools.com
c) The physical wires between the input and output field devices and the PLC input and output
modules are the only signal wires required in the PLC system.
d) The cost and size of PLCs have increased significantly in the last 10 years.
om
17. Which of the following statements about a single pole double throw relay is NOT
.c
true?
s
a) It is called an SPDT type of relay.
ol
b) It has one common contact. To
on
c) It has two positions (NC and NO).
i
18. Which of the following statements about a single pole double throw relay is true?
nt
me
a) Insulators are used in the armature to isolate the electrical switching contacts from the rest of
the relay components.
ru
b) The NC contact and the pole are in contact when the relay is off.
st
In
c) NC contact symbol has the same two parallel lines with a line across them to indicate closed
contacts.
d) The right power rail is positive or the high side of the source, and the left power rail is
the power return or ground.
20. The _____ is moved toward the relay electromagnet when the relay is on.
a) Armature
b) Coil
InstrumentationTools.com
Instrumentation Tools
Learn Instrumentation and Control Engineering. Inst Tools covers topics of Industrial
Instrumentation, PLC, DCS, SCADA, Field Instruments, Analyzers and so on.
https://instrumentationtools.com
c) NO contact
d) NC contact
om
a) There is an electrical path through the NO contacts
.c
b) There is an electrical path through the NC contacts
s
ol
c) Neither the NO or the NC contacts have an electrical path
To
d) Both the NO and the NC contacts have an electrical path
on
22. Which of the following RLL applications is not normally performed in early
i
automation systems?
at
om
s .c
ol
To
i on
a) AC output modules
at
c) Both a and b
ru
d) Neither a or b
st
26. What one item in the output module circuit above should be changed to make it
In
correct.
InstrumentationTools.com
Instrumentation Tools
Learn Instrumentation and Control Engineering. Inst Tools covers topics of Industrial
Instrumentation, PLC, DCS, SCADA, Field Instruments, Analyzers and so on.
https://instrumentationtools.com
27. What one item in the input module circuit above should be changed to make it
correct.
om
a) The battery polarity
.c
b) Input module should be sinking
s
ol
c) Field device should be sinking
To
d) Current flow direction
on
28. When _____ contacts are actuated, they disrupt the power supply through them.
i
at
c. both a. and b.
ru
29. The type of memory which is fast and temporarily stores the data which are
immediately required for use is called as______.
a. HDD
b. ROM
c. RAM
d. SSD
30. How is the speed of operation of conventional relay system as compared to digital
controllers?
a. very slow
b. very fast
c. same
d. almost similar
InstrumentationTools.com
Instrumentation Tools
Learn Instrumentation and Control Engineering. Inst Tools covers topics of Industrial
Instrumentation, PLC, DCS, SCADA, Field Instruments, Analyzers and so on.
https://instrumentationtools.com
31. The capability of convention relay systems for complex operations is ____ that of the
PLCs .
a. poor than
b. excellent than
c. as good as
om
d. unpredictable as
.c
32. How is the noise immunity of PLCs to electrical noises as compared to that of
s
conventional relay controllers?
ol
a. poor To
on
b. excellent
i
d. unpredictable
nt
me
a. Programming
st
b. Installation
In
c. Commissioning
a. only programmed
b. only reprogrammed
a. machine tools
1. Relay coils
2. Solenoids
3. Indicators
om
.c
4. Motors
s
5. Lamps
ol
6. Alarms To
on
Select correct option
i
37. Which of the following cannot be an input that is given to the PLC?
In
a. Manual switches
b. Relays c. Sensors
PLCs are highly reliable, easily programmable, Small and Inexpensive, PLCs can be designed
with the communication capabilities so they can converse with the local or remote computer,
They can sustain in robust environment less maintenance.
InstrumentationTools.com
Instrumentation Tools
Learn Instrumentation and Control Engineering. Inst Tools covers topics of Industrial
Instrumentation, PLC, DCS, SCADA, Field Instruments, Analyzers and so on.
https://instrumentationtools.com
The general language program consists of Ladder Diagrams. Relay logic control scheme is
represented in Ladder diagrams. Alternative languages uses Boolean representation of these
control schemes as base of the computer representation.
CPU is the brain of the system and consists of Microprocessor: To carryout arithematic and
logical operations Memory: The area in the CPU in which the information is stored and reterived
Power Supply: The electrical supply that converts the ac voltage to various DC operating
om
voltages.
.c
5. Explain what is SCAN in PLC ?
s
ol
The sequential operation of the controller that goes through the ladder diagram from top to
bottom of the ladder. In this process it updates all the outputs corresponding to the inputs.
To
SCAN takes place from left to right of each rung. Usually SCAN time is in milliseconds and it is
on
a continuous process.
i
Programmable Logic Controllers (PLCs) have basic architecture compared to normal general
nt
purpose computers. A normal computer can be converted to PLCs by providing a way that the
me
computer can able to receive information or signal from the field devices such as push buttons,
switches and valve positions. Computer requires a some software to process the information
ru
obtained from the input to generate an output which decide whether to close or open the valve
position in the process side.
st
In
Some of the important features and characteristics that distinguish between the general
purpose computers and Programmable Logic Controllers
PLCs are designed to operate under industrial environments (PLCs have to operate under wide
range of temperature conditions, humidity and other environmental conditions). They are least
affected by the electrical noise and are inherent to electrical noise
Programming in PLCs is through Relay Ladder Logic or other easily learned language. PLCs
comes with program language built in its memory. PLCs do not contain input and output devices
such as keyboards, mouse, monitor, CD drives and other hard disks. It is in simple a self
contained box with communication ports and set of terminals for input and output devices.
Unlike computers which performs numerous tasks simultaneously, PLCs execute a single
program in an orderly and sequential manner from first instruction to the last instruction
PLCs have been designed for installation and maintenance by plant electricians. Programming
in PLCs is simple (Relay Ladder Programming), it does not include any advanced code.
Troubleshooting is simpler and many PLCs are designed to include fault details and written fault
details on display screen.
InstrumentationTools.com
Instrumentation Tools
Learn Instrumentation and Control Engineering. Inst Tools covers topics of Industrial
Instrumentation, PLC, DCS, SCADA, Field Instruments, Analyzers and so on.
https://instrumentationtools.com
Higher Reliability:
Once the program written and tested it can be easily downloaded into other PLC’s memory. It
requires lesser and simpler wiring compared to conventional hard wired circuits employed.
Hence reliability of the system increases significantly with PLCs.
More Flexibility:
om
.c
It is easier to create a new program module or change an existing program in PLC compared to
hard wired circuitry system. These software program modules can be changed whenever
s
required. Use can modify the programs in the field and if required, security can be enhanced by
ol
hardware interlocks such as key locks and software features such as passwords
To
Lower Cost:
on
PLCs were originally designed to replace relay control logic which is not economical and
i
complex especially for large control circuits. With PLCs the cost savings have been so
at
significant that the relay control becomes uneconomical except for some power applications.
Generally if the application consists of more than half a dozen control relays, PLCs are least
nt
expensive to install
me
Communication Capability:
ru
Communication capability of PLC with the other controllers and computers in the system is one
st
of the main advantages compared to relay control circuit. Functions such as Supervisory
In
control, data acquisition from the field, monitoring devices and process parameters associated
with the field and downloading and uploading of programs can be easily possible with the PLC
compared to hardwired circuits
Faster Response:
PLCs are designed for high speed and for the real time applications.Response time for PLCs
are much smaller compared to relay logic circuits. The programmable controllers operates in
real time i.e, an event taking carrying out at field will result in execution of operation of output
Easy to Troubleshoot:
PLCs have inbuilt diagnostics and override functions that helps the user to easily trance the
software and hardware errors.
Programmable Logic Controllers (PLCs) are the micro processor controller devices situated at
the remote sites of the plant or at the field of the process systems. PLCs purpose is to monitor
the process parameters located at the field and adjust the outputs based on the inputs received
InstrumentationTools.com
Instrumentation Tools
Learn Instrumentation and Control Engineering. Inst Tools covers topics of Industrial
Instrumentation, PLC, DCS, SCADA, Field Instruments, Analyzers and so on.
https://instrumentationtools.com
by the PLCs. PLCs will operate on any systems which will have input field devices that are On-
Off type (discrete or digital ) or analog input devices. Similarly it will operate on the field devices
which will be discrete or analog output type.
In simple words, Hence PLC acts as interface between the input and output devices at the
process side of the industries. It monitors the inputs receive from the input devices and takes
necessary output control functions by executing the programs stored in its memory.
The term Logic is used in Programmable Logic Controllers because all the program inside the
om
PLC will be of Logic programming (eg: Ladder diagrams ).
.c
In industrial applications hard wired relay logics were replaced by Programmable Logic
s
Controllers due to its reliablity, simplicity, low cost, easier programming and many other
ol
functions.
To
i on
at
nt
me
ru
st
In
InstrumentationTools.com
Powered by TCPDF (www.tcpdf.org)