350W Single Output Switching Power Supply LRS-350 series
■ Description
LRS-350 series is a 350W single-output enclosed type power supply with 30mm of low profile design. Adopting
the input of 115VAC or 230VAC (select by switch), the entire series provides an output voltage line of 3.3V,
4.2V, 5V, 12V, 15V, 24V, 36V and 48V.
In addition to the high efficiency up to 89%, with the built-in long life fan LRS-350 can work under -25~
+70℃ with full load. Delivering an extremely low no load power consumption (less than 0.75W), it allows
the end system to easily meet the worldwide energy requirement. LRS-350 has the complete protection
functions and 5G anti-vibration capability; it is complied with the international safety regulations such as
UL60950-1. LRS-350 series serves as a high price-to-performance power supply solution for various
industrial applications.
■ Model Encoding
LRS - 350 - 3.3
Output voltage
Output power
Series name File Name:LRS-350-SPEC 2016-10-31
350W Single Output Switching Power Supply LRS-350 series
SPECIFICATION
MODEL LRS-350-3.3 LRS-350-4.2 LRS-350-5 LRS-350-12 LRS-350-15 LRS-350-24 LRS-350-36 LRS-350-48
DC VOLTAGE 3.3V 4.2V 5V 12V 15V 24V 36V 48V
RATED CURRENT 60A 60A 60A 29A 23.2A 14.6A 9.7A 7.3A
CURRENT RANGE 0 ~ 60A 0 ~ 60A 0 ~ 60A 0 ~ 29A 0 ~ 23.2A 0 ~ 14.6A 0 ~ 9.7A 0 ~ 7.3A
RATED POWER 198W 252W 300W 348W 348W 350.4W 349.2W 350.4W
RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 200mVp-p
OUTPUT VOLTAGE ADJ. RANGE 2.97 ~ 3.6V 3.6 ~ 4.4V 4.5 ~ 5.5V 10.2 ~ 13.8V 13.5 ~ 18V 21.6 ~ 28.8V 32.4 ~ 39.6V 43.2 ~ 52.8V
VOLTAGE TOLERANCE Note.3 ±4.0% ±4.0% ±3.0% ±1.5% ±1.0% ±1.0% ±1.0% ±1.0%
LINE REGULATION Note.4 ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
LOAD REGULATION Note.5 ±2.5% ±2.5% ±2.0% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5%
SETUP, RISE TIME 1500ms, 50ms/230VAC 1500ms,50ms/115VAC at full load
HOLD UP TIME (Typ.) 16ms/230VAC 12ms/115VAC at full load
VOLTAGE RANGE 90 ~ 132VAC / 180 ~ 264VAC by switch 240 ~ 370VDC (switch on 230VAC)
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 79.5% 81.5% 83.5% 85% 86% 88% 88.5% 89%
INPUT
AC CURRENT (Typ.) 6.8A/115VAC 3.4A/230VAC
INRUSH CURRENT (Typ.) 60A/115VAC 60A/230VAC
LEAKAGE CURRENT <2mA / 240VAC
110 ~ 140% rated output power
OVER LOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION 3.8 ~ 4.45V 4.6 ~ 5.4V 5.75 ~ 6.75V 13.8 ~ 16.2V 18 ~ 21V 28.8 ~ 33.6V 41.4 ~ 46.8V 55.2 ~ 64.8V
OVER VOLTAGE
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER TEMPERATURE Hiccup mode, recovers automatically after fault condition is removed
FAN ON/OFF CONTROL RTH3≧50℃ FAN ON, ≦40℃ FAN OFF
FUNCTION (Typ.)
WORKING TEMP. -25 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY 20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)
VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS UL60950-1 approved
SAFETY WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25℃/ 70% RH
MTBF 327.9K hrs min. MIL-HDBK-217F (25℃)
OTHERS DIMENSION 215*115*30mm (L*W*H)
PACKING 0.76Kg; 15pcs/12.4Kg/0.78CUFT
NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up
time.
7.The 150% peak load capability is built in for up to 1 second for 12~48V.LRS-350 will enter hiccup mode if the peak load is delivered
for over 1 second and will recover once it resumes to the rated current level(115VAC/230VAC).
8. The ambient temperature derating of 5℃/1000m is needed for operating altitude greater than 2000m(6500ft).
File Name:LRS-350-SPEC 2016-10-31
350W Single Output Switching Power Supply LRS-350 series
Block Diagram
115/230V(SW) RECTIFIERS fosc : 65KHz
& FAN
FILTER
FAN ON/OFF CONTROL
EMI POWER RECTIFIERS +V
I/P RECTIFIERS &
FILTER SWITCHING -V
FILTER
O.T.P.
FG O.V.P.
O.L.P. PWM
CONTROL DETECTION
CIRCUIT
Derating Curve Static Characteristics
100
100
90
80
180 ~ 264VAC
80 90 ~ 132VAC
60 70
LOAD (%)
LOAD (%)
60
40
50
20
40
-25 -20 -10 0 10 20 30 40 50 60 70 (HORIZONTAL) 90 95 100 105 110 115 120 125 132
180 190 200 210 220 230 240 250 264
AMBIENT TEMPERATURE (℃) INPUT VOLTAGE (VAC) 60Hz
File Name:LRS-350-SPEC 2016-10-31
350W Single Output Switching Power Supply LRS-350 series
Mechanical Specification Case No.207A Unit:mm
215
32.5 150
LED
+V
36.7
ADJ.
9
8
4-M4 L=3mm
7
9.5
115
6
50
135
5
47.45
4
3
8
32.5
1
16
15
32.5 150
Terminal Pin No. Assignment :
2
Pin No. Assignment Pin No. Assignment
12.8 6.9
30
Air flow 1 AC/L 4~6 DC OUTPUT -V
direction
12.5
2 AC/N 7~9 DC OUTPUT +V
6.5 6.5 4-M4(Both Sides) L=5mm 3 FG
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
File Name:LRS-350-SPEC 2016-10-31