Tech Note 923 - Resolving Excel Reporting Missing
Tech Note 923 - Resolving Excel Reporting Missing
All Tech Notes, Tech Alerts and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of Use for more information.
Topic#: 002738
Created: February 2013
Introduction
When configuring ActiveFactory Reporting website using the Configurator from the System Platform 2012 R2, you might encounter the
following warning message preventing the configuration from completing.
The Microsoft Excel Application component is missing additional configuration required for ActiveFactory Reporting.
This Tech Note shows how to resolve the issue so that you can continue configuring the ActiveFactory Reporting component successfully.
Application Versions
file:///C|/inetpub/wwwroot/t002738/t002738.htm[2/15/2013 2:41:43 PM]
Resolving Issue: The Microsoft Excel Application component is missing additional configuration required for ActiveFactory Reporting
Note: This Tech Note assumes that you are familiar with the above products. If you have any questions about Microsoft Excel, please
contact Microsoft technical support at www.microsoft.com.
Procedure
1. From the Start Menu, click Run.
3. In the Component Services window, expand Component Services/Computers/My Computer and then DCOM Config.
4. Locate Microsoft Excel Application, then right click the component and click Properties.
5. In the Microsoft Excel Application Properties dialog, click the Identity tab and make sure The Interactive user option is
selected.
8. Populate the Historian Data Source and Historian Configuration fields, then click Configure.
The ActiveFactory Reporting configuration should now finish successfully (Figure 6 below).
Tech Notes are published occasionally by Wonderware Technical Support. Publisher: Invensys Systems, Inc., 26561 Rancho Parkway South, Lake Forest, CA 92630. There is also
technical information on our software products at Wonderware Technical Support.
Back to top