PWT Water Proof Scale Manual

This document is the user manual for a waterproof digital scale. It provides instructions on installation, operation, functions, and troubleshooting. The scale has multiple weighing units, adjustable speed and auto-off settings, upper and lower limit alarms, and single-point calibration. The manual covers unpacking, setup, battery replacement, key functions, unit conversion, tare, counting, and provides one year of warranty against defects excluding damage from misuse.

Uploaded by

TakaSensei
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
388 views

PWT Water Proof Scale Manual

This document is the user manual for a waterproof digital scale. It provides instructions on installation, operation, functions, and troubleshooting. The scale has multiple weighing units, adjustable speed and auto-off settings, upper and lower limit alarms, and single-point calibration. The manual covers unpacking, setup, battery replacement, key functions, unit conversion, tare, counting, and provides one year of warranty against defects excluding damage from misuse.

Uploaded by

TakaSensei
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

Waterproof Balance ( scale )

User’s Manual
Co n t e n t S
【1】Attention .......................................... 1
1.1 Conventional Attention
1 . 2 Attention before using
【2】Installation ....................................... 2
2.1 Scale ' s Installation
2 . 2 Battery Replacement
【3】Instruction ....................................... 2
3.1 Main Parameter
3 . 2 Power
【4】Display ............................................ 3
4.1 Panel Instruction
4 . 2 Definition of Key
【5】Operation ........................................ 4
【6】Function Settings ............................. 6
【7】Error Messages ................................ 7
【8】Detailed Models ............................. 7
【9】Warranty ......................................... 7
Thanks for using the waterproof balance (scale) of our company.
The high quality and reliability of the products will make you satisfied.
Through the use of the products you will be able to fully realize the high
quality and reliability of our products, and believete tahat our products
can fully meet your requirements. If you have any suggestions, please
free to contact us.

【1】A t t e n t i o n
1.1 Conventional Attention
1. In order to apply the balance (scale) correctly, please read the
instruction manual completely before using the scale so that you can
know clearly the performance and operation of product.

2. Keep the balence (scale) clean if the product will not be used for a
long time and recharge the battery once every three months. When
applying the product again a long time later,you must recharge the
battery at first.

3. The maintenance-free lead-acid batteries is installed in the product


,which life is due to how to use it ,so it is beyond the scope of the
warranty.
1.2 Attention Before Use
1. Place the balance (scale) on a clean,firm and plat surface of table
to avoid vibrations,heat sources,or rapid temperature changes.Adjust
the 4 leveling feet so that the bubble is centered in the circle.
Be sure the scale is level each time its location is changed.
2. Connect the AC adapter to the independent power supply for
avoiding interference form other power.
3. Do not put loads on the pan when you turn scale on.
4. Preheat the balance (scale) for 3-5 minutes before use.
5. For weighing accuracy, the center of gravity of object should be
placed in the center of and beyond the edge of pan.

W arnin g:D o n ' t be charging in the wa t e r

-1-
【2】I n s t a l l a t i on
2.1 Installation Body’S
1. Contents in Box
No. Name Unit Qty.
1 scale’s body pc 1
2 instruction manual pc 1
3 qualification pc 1
4 service manual pc 1
5 stainless steel pan pc 1
6 foam set 1

2 . Place the scale’s body on the surface of a firm and


horizontal table,adjust the feet to keep the scale stable
so that the bubble is centered in the circle .
3 . Put the pan onto the weighing platform before turning
the scale on, then enter weighing mode.

【3】 Instruction
3.1 Main Parameters
Accuracy : III
Model : (3000-30000)d
Nonlinearity : ≤0 . 0 1 % F . S
System Working Voltage: DC 5 V
Conversion Rate: 2 0 times / sec.(adjustable)
Internal Resolution: 1 million

3.2 Power
Input : AC 220 V
Output : AC 12 V 1 A

-2-
【4】Display
4.1 Cursor Indicator

STABLE kg
T
NET g

ZERO pcs

0
LowBat Hi Ok Lo Hold lb.oz lb AC

4.2 Definition of Keys

: press the key and weight displays to zero when load is


T
in the scope of tare weight. Net weight cursor is bright to
display net weight.in weighing mode , long press the key
for 3 seconds to turn on/off the function of animal scale.
0 : press the key and weight display zero when load is in
the scope of zero. Zero point cursor is bright to display
zero position . In weighing mode,long press the key for 3
seconds to convert units.
: In weighing mode , press the key to turn on/off the
function of alarm . Long press the key for 3 seconds
to set the function of alarm in weighing mode.
:press the key to turn scale on when power off.
press the key to display “off” and turn scale off when
power on .
press the key to enter function setting in weighing mode.

-3-
【5】Operation
5.1 Turn Scale On
When power off, press key,LED is all bright and count backward
from 999999 to 000000, then display model and voltage of
battery, enter weighing mode.
5.2 Unit Conversion
Long press 0 key for 3 seconds to convert the units of kg ,
g , lb , lb - oz , pcs.in weighing mode.
5.3 Animal weighing
Long press T key for 3 seconds to turn on/off animal weighing
mode.
5.4 Count
Long press T key for 3 seconds to display { SP = 5 },and } place
the samples, then press T key to select the sample number 5 ,
1 0 , 2 0 , 5 0 , 1 0 0 , 2 0 0 , 5 0 0,press 0 key to display the
sample number .
5.5 Upper and Lower Limit Settings
In weighing mode,turn on function of high and low limit,long press
key for 3 seconds , display { SET - Hi } , press 0 key to enter upper
limit settings: press T key to change number , press key to
move position , press 0 key , display { SET - LO } ; press 0 to
enter lower limit settings: press T key to change number , press
key to move position , press 0 key , display { SET - Li } ;
press 0 key to set and press 0 key , display { SET - CK } ,
press 0 key to enter stable mode settings : press T key to
select, stable alarm { Lim - St } or unstable alarm { Lim - uS } , press
0 key to set and display { Lim-BZ } ; press 0 key to enter buzzer
alarm settings: press T key to select, buzzer tweet { Lim - BZ }
or no buzzer tweet Lim - Mu } , press 0 key to set and return to
normal weighing mode.
-4-
5.6 Single-Point Calibration
In the mode of power off, press and hold T key, then press
key to display { CAL }. When no - load,press 0 key to calibrate
zero point,display { C-ZERO } first , and 1 second later automatic
display { SPAN },place 1/3 or 2/3 or full capacity weights , display
{ on1 } or { on2 } or { on3 } stable , then display { pass } and count
backward to the weighing mode.

【6】Function Settings
6.1 Using Function Settings
In weighing mode , press key to enter user function
settings : display { SPED - X }, then press key to set
weighing speed, { SPED - F } fast ,{ SPED - M } middle , { SPED - S }
slow. Press T key to display { AJ - X } and press to
set anti-shaking function,AJ 0- AJ 9 express that 0-9 d division are
locked,then press T key to display { APF - XX },press
key to set automatic power off time: { APF -0}- no power off,
{ APF -10}- 10 min . power off, { APF -20}- 20 min . power off,
{ APF -30}- 30 min . power off, { APF -60}- 60 min . power off.
Press T key to display { PS - XXX } and press key to
set power saving mode: { PS - on }- turn on power saving mode and
{ PS - off }- turn off power saving mode , then press T key to
display { Save - x } and press key to set save unit when turn
on: { Save - Y }- save the unit when turn on and { Save - N }- not save
the unit when turn on. Then press T key to return weighing
mode.

-5-
6.2 Units Settings
When counting backward before entering weighing mode , press
and hold 0 key to display { 1 1 1 1 1 0 },press key
to move and press T key to change figure,then press 0
key to set: 1 - on,0 - off.The units are from left to right: g,kg,lb,
lb - oz,pcs,nothing.

【7】Error Messages
Error Messages Solutions
Low voltage lamp flicker Recharge the Battery
Display B - Err Recharge the Battery
O - load Overload,loss weight
Exceed initial zero , modify settings
O - zero
or remove objects

【8】Detailed Modes
Capacity 3kg 6kg 15kg 30kg

Devision 0.5/1g 1/2g 2/5g 5/10g

-6-
【9】Warranty
Thank you for using our products . We shall supply
good service after sales and solve your problem on time
in the future.

During one year warranty period, repair or at it option ,


replace any component(s)that proves to be defective at no
charge exclude the artifical damage, in the meantime you
must show the invoice and valid warranty card of product to
our service center.

In the following situation , you must pay for the item :

1. The artifical damage;

2. The damage by nature and man made disaster;

3. The user ' s own disassembly or the other unauthorized


man ' s maintenance ;

4. The battery is consumable to not be in the scope of


warranty.