The MP10 probe system consists of an MP10 probe, OMM or OMI interface unit, and optional power supplies. The MP10 probe is used for workpiece setup and inspection on CNC machines. It features wide beam transmission up to 130 degrees and full 360 degree signal transmission with a range of up to 6 meters. The system provides repeatable probing accuracy of 1 micrometer. Key components include the probe, OMM/OMI interface units, and optional power supplies.

Uploaded by

Arjuna Gaming
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
48 views4 pages

Data Sheet - MP10 Probe System

The MP10 probe system consists of an MP10 probe, OMM or OMI interface unit, and optional power supplies. The MP10 probe is used for workpiece setup and inspection on CNC machines. It features wide beam transmission up to 130 degrees and full 360 degree signal transmission with a range of up to 6 meters. The system provides repeatable probing accuracy of 1 micrometer. Key components include the probe, OMM/OMI interface units, and optional power supplies.

Uploaded by

Arjuna Gaming
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Data sheet

H-2000-2262-02-D

MP10 probe system

OMM (optical module machine) + MI 12


MP10 probe with 35° or or OMI (optical machine interface)
MP10 probe with 70° output
VERTICAL

Shank

35° OMP
(optical
module Optical centre line
70° probe)
OMM OMI

HORIZONTAL MI 12 interface unit Optional Optional


or MI 12 board
Probe PSU3 PSU3
head power power
supply supply
Stylus unit unit
Weak link
Optional Workpiece

CNC machine CNC machine


control control

System components System features


MP10 probe Signal transmission
The MP10 probe is used for workpiece set-up and The MP10 is available with either 35° or 70° output and
inspection on CNC machining centres. features wide beam transmission - up to 130°.
Full 360° signal transmission and up to 6 m (19.6 ft) range.
OMM (optical module machine)
Infrared optical filters reduce interference to data
Transmits CNC messages to the probe and receives
transmission.
data signals for transmission to the MI 12 interface.
Battery life
MI 12 interface unit
A battery life of 140 hours continuous use or the
Processes signals between the OMM and the CNC
equivalent of 98 days at 5% usage is achievable.
machine control.
Probe repeatability
OMI (optical machine interface)
Repeatability, 1.0 µm (40 µin) is certified at
An alternative to the OMM + MI 12 interface,
480 mm/min (1.57 ft/min).
combining the functions of both OMM and MI 12
Probe switch-on
in one unit.
Probe switch-on is selectable between M code and
PSU3 power supply unit for MI 12 or OMI auto start.
Used when 24 V supply is not available from the
Probe, OMM and OMI sealing
machine. Sealed to IP68 and designed for the machine tool
Software for probe routines environment.
The MP10 is suitable for use with Renishaw Break protection
single and double touch probing cycles. A stylus weak link is included in each kit, to protect
the probe in the event of excessive stylus overtravel.

Each system component is fully described on its own separate Data sheet - please see Parts list on back page.
Performance envelope - probes with 35° or 70° output
The MP10 has a full 360° transmission envelope over the Natural reflective surfaces within the machine may
ranges shown below. increase the signal transmission range.
The probe system should be positioned such that the optimum Coolant residue accumulating on the OMP LED's
range can be achieved over the full travel of the machine axis. and OMM/OMI window, will have a detrimental effect
The OMP and OMM/OMI may deviate from the optical centre line, on transmission performance.
provided opposing light cones always overlap with transmitters
Wipe clean as often as is necessary to maintain
and receivers mutually in each others field of view (eye to eye).
unrestricted transmission.

MP10 35° output probe with OMM MP10 35° output probe with OMI
60° OMI
OMM 60°
45°
45°

30°
30°
Optical centre line 15° 1(3.
3)
Optical centre line 1(3.3)
15° 0° 2 (6
2 (6.5) .5)
0° 15°
3 (9.8) 3 (9
30° 45° .8)
60° 45° 60°
75° 4 (13.1)
30° 15°
90° 5 (16.4) 75° 60° 45° 30°
15° 30° 90° 15°
6 (19.6) 45° 60° 6 (19.6) 3 (9.8) 0°
5 (16.4)

2 (6.5)
4 (13.1) 15°
3 (9.8) 15° 1 (3.3)
30°
2 (6.5)
1 (3.3) 30°

35° OMP
45°
35° OMP

Switch-on/off range Operating range Range metres (feet) Switch-on/off range Operating range
The OMP must be The OMP must be The OMP must be The OMP must be
SWITCH ON/OFF
within 3 m (9.8 ft) within 6 m (19.6 ft) within 3 m (9.8 ft) within 3 m (9.8 ft)
of the OMM. of the OMM. OPERATING of the OMI. of the OMI.

MP10 70° output probe with OMM MP10 70° output probe with OMI
OMM
OMI

1(3.3)
60° 2 (6.5)
3 (9.8)
45° 4 (13.1) 60° 1(3.
3)
5 (16.4) 2 (6
45° .5)
30° 6 (19.6)
30° 3 (9
Optical centre line 60° .8)
Optical centre line
15° 15° 60°
45° 45°
30° 15° 0° 30° 15° 30°
15°
45° 15° 0°
15° 30°
45°
60° 15°
60°
30° 30°
75° 75°

90° 45°
45°
90° 3 (9.8) 60°
.6) 2 (6.5)
(19 6.4) 60° 1 (3.3)
6 )
(1 3.1 .8)
5 (1
4 (9 .5)
3 (6 .3)
2 (3
1 70° OMP
70° OMP
System operation Probe features
Prior to probe operation it is imperative to ensure that Stylus on-centre adjustment
the program selected to 'drive' the probe has been verified. Standard Optional
Incorrect programming could result in damage to the Translation screw adjusters Stylus on-centre adjustment
machine, workpiece and probe system. with Ø8 mm ball
The battery powered MP10 has two modes of operation. For applications where
1. Stand-by mode the stylus stem must be
To conserve battery life the probe is held in the stand-by parallel with the
mode, until the CNC control sends a start signal via the spindle centre line
OMM or OMI, to the OMP receiving diodes (Rx).
The start signal switches the probe to the operating mode.
2. Operating mode
During the operating mode, probe signals are transmitted
through 360° from the OMP transmitting LED's (Tx), to the
OMM or OMI for onward transmission to the CNC control. OMP
Optical module probe
PROBE SWITCH-ON
The probe is switched-on by one of the following options. Battery Transmitting LED
1. Manual start (6 x Tx)
(system with OMM + MI 12 only) Probe status LED
Initiated by pressing the MI 12 manual start button. (1 x red - green) Probe setting
+ options switch
2. Machine start (factory set to this option) Receiving diode
(system with OMM + MI 12 or system with OMI) (3 x Rx) - Selects switch-off mode
and switch-off time delay
Initiated by an M code generated by the program.
3. Auto start Probe head
(system with OMM + MI 12 or system with OMI)
Initiated by auto start signal sent every second. Stylus spring Weak link
PROBE SWITCH-OFF pressure adjustment
(optional)
The probe is switched-off by one of the following options.
1. Optical-on / timer-out (factory set to this option)
A timer automatically returns the probe to stand-by if the
probe has not been used for 33 seconds or 134 seconds Stylus
(factory set to 134 seconds).
2. Optical-on / optical-off
A second start signal is generated by a software M code,
which switches the probe off after 5 seconds or 9 seconds Shank manufacturing details
(factory set to 9 seconds).
6 (0.24) GAUGE
LINE
4.5 (0.18)
PROBE STATUS LED Ø20.10 (0.791) 4.3 (0.17)
The probe status LED gives a visual indication of the Ø20.02 (0.788)
probe state (triggered or seated). It also indicates 0.8 32
when the battery has become unuseable. Two holes
LED colour Probe status M8 x 1.25 thro.
equi-spaced
Flashing green Stylus seated
into bore Ø25.0 (0.984)
Flashing red Stylus deflected Ø24.8 (0.976)
Not convex
0.8 32

Constant red Battery dead


C 27.5
Battery dead - At this stage probe status is 0.05 C
forced open and the probe cycle will stop. 25.5
0.02 (1.08)
(1.00)
35° OMP shown Optical signal Alternative 70° or 35°
transmitters probe outputs Translational
Z Overtravel on-centre adjustment
Ø62 70°
8 (0.31) Ø48 22 (2.44) with adjusting plate
XY Overtravel (1.89) (0.87)
35° Pull stud
(not supplied by Renishaw)

17.5°

Ø6 17.5°
(0.24)
21.5
(0.85) See Data sheet
V flange taper shank
taper shanks
Stylus 70° OMP 70° OMP 69.8 (2.75) to suit machine.
H-2000-2011
50 (1.96) long 46.4 (1.82) 35° OMP 67.9 (2.67) (available from Renishaw)
for dimensions
Other length 35° OMP Add 1.4 (0.06) if the A A
styli may be used 48.8 (1.92) ball is used GAUGE LINE

dimensions mm (in)
Renishaw plc T +44 (0)1453 524524
New Mills, Wotton-under-Edge, F +44 (0)1453 524901
Gloucestershire GL12 8JR E [email protected]
United Kingdom www.renishaw.com

MP10 probe specification


Primary application Inspection probe
for machining centres
Stylus overtravel
limits Sense directions 5 way
Trigger force
Stylus length X Y 0.75 N / 75 gf (2.64 ozf)
using 50 mm (1.97 in) stylus
50 mm (1.96 in) low force direction Z 4.2 N / 420 gf (14.83 ozf)
X/Y Z
Trigger force
21.5 mm 8 mm X Y 1.4 N /140 gf (4.92 ozf)
using 50 mm (1.97 in) stylus
(0.84 in) (0.31 in) 21.5 mm high force direction Z 4.2 N / 420 gf (14.83 ozf)
(0.85 in)
Stylus length Overtravel X Y 17.5°
100 mm (3.93 in) Z 8 mm (0.31 in)
X/Y Z Sealing IPX8 (BS 5490, IEC 529)
36.5 mm 8 mm 1 atmosphere
Z
(1.44 in) (0.31 in) Repeatability, maximum 1.0 µm
17.5° 17.5°
2σ value in any direction 0.0000 4in
X/Y
Repeatability specification of 1.0 µm (0.00004 in) 2σ
for a test velocity of 480 mm/min (1.57 ft/min).
Battery life expectancy

5% USAGE - 72 min/day CONTINUOUS USE


Alkaline STAND-BY
OPTICAL ON OPTICAL ON OPTICAL ON OPTICAL ON
battery type LIFE OPTICAL OFF TIMER OFF OPTICAL OFF TIMER OFF
Duracell MN 1604 Minimum Minimum Minimum Minimum Minimum
or equivalent
365 days 98 days 80 days 140 hrs 110 hrs

Parts List - Please quote the Part no. when ordering equipment
Type Part No. Description

MP10 kit A-2033-1101 MP10 35° probe + battery, stylus, OMM, mounting bracket, MI 12 interface unit and tool kit.
MP10 kit A-2033-1102 MP10 70° probe + battery, stylus, OMM, mounting bracket, MI 12 interface unit and tool kit.
MP10 kit A-2115-0024 MP10 35° probe + battery, stylus, OMI, mounting bracket and tool kit.
MP10 kit A-2115-0025 MP10 70° probe + battery, stylus, OMI, mounting bracket and tool kit.
MP10 A-2033-1099 MP10 35° probe + battery, weak link stem, centre ball and tool kit - factory set to time out.
MP10 A-2033-1100 MP10 70° probe + battery, weak link stem, centre ball and tool kit - factory set to time out.
MP10 A-2033-1115 MP10 35° probe + battery, weak link stem, centre ball and tool kit - factory set to optical off.
MP10 A-2033-1116 MP10 70° probe + battery, weak link stem, centre ball and tool kit - factory set to optical off.
Stylus A-5000-3709 PS3-1C stylus Ø6 ball x 50mm long with ceramic shaft.
Weak link kit A-2085-0068 Kit comprising: two stylus weak link stems, spanner and instruction sheet.
Weak link stem M-2085-0069 Stylus weak link stem.
Spanner P-TL09-0003 Spanner for weak link stem.
Battery P-BT03-0001 PP3 9 V alkaline battery.
Styli — See Brochure H-1000-3200 Styli and accessories.
Shank — See Data Sheet H-2000-2011 Taper shanks.
OMM — See Data Sheet H-2000-2275 Optical module machine.
MI 12 — See Data Sheet H-2000-2195 MI 12 interface unit.
OMI — See Data Sheet H-2000-2285 Optical machine interface (alternative to OMM + MI 12).
PSU3 — See Data Sheet H-2000-2200 PSU3 power supply unit (optional).
Software — See Data Sheet H-2000-2289 Probe software for machine tools.

For worldwide contact details please visit our website at www.renishaw.com