Data Sheet - MP10 Probe System
Data Sheet - MP10 Probe System
H-2000-2262-02-D
Shank
35° OMP
(optical
module Optical centre line
70° probe)
OMM OMI
Each system component is fully described on its own separate Data sheet - please see Parts list on back page.
Performance envelope - probes with 35° or 70° output
The MP10 has a full 360° transmission envelope over the Natural reflective surfaces within the machine may
ranges shown below. increase the signal transmission range.
The probe system should be positioned such that the optimum Coolant residue accumulating on the OMP LED's
range can be achieved over the full travel of the machine axis. and OMM/OMI window, will have a detrimental effect
The OMP and OMM/OMI may deviate from the optical centre line, on transmission performance.
provided opposing light cones always overlap with transmitters
Wipe clean as often as is necessary to maintain
and receivers mutually in each others field of view (eye to eye).
unrestricted transmission.
MP10 35° output probe with OMM MP10 35° output probe with OMI
60° OMI
OMM 60°
45°
45°
30°
30°
Optical centre line 15° 1(3.
3)
Optical centre line 1(3.3)
15° 0° 2 (6
2 (6.5) .5)
0° 15°
3 (9.8) 3 (9
30° 45° .8)
60° 45° 60°
75° 4 (13.1)
30° 15°
90° 5 (16.4) 75° 60° 45° 30°
15° 30° 90° 15°
6 (19.6) 45° 60° 6 (19.6) 3 (9.8) 0°
5 (16.4)
0°
2 (6.5)
4 (13.1) 15°
3 (9.8) 15° 1 (3.3)
30°
2 (6.5)
1 (3.3) 30°
35° OMP
45°
35° OMP
Switch-on/off range Operating range Range metres (feet) Switch-on/off range Operating range
The OMP must be The OMP must be The OMP must be The OMP must be
SWITCH ON/OFF
within 3 m (9.8 ft) within 6 m (19.6 ft) within 3 m (9.8 ft) within 3 m (9.8 ft)
of the OMM. of the OMM. OPERATING of the OMI. of the OMI.
MP10 70° output probe with OMM MP10 70° output probe with OMI
OMM
OMI
1(3.3)
60° 2 (6.5)
3 (9.8)
45° 4 (13.1) 60° 1(3.
3)
5 (16.4) 2 (6
45° .5)
30° 6 (19.6)
30° 3 (9
Optical centre line 60° .8)
Optical centre line
15° 15° 60°
45° 45°
30° 15° 0° 30° 15° 30°
15°
45° 15° 0°
15° 30°
45°
60° 15°
60°
30° 30°
75° 75°
90° 45°
45°
90° 3 (9.8) 60°
.6) 2 (6.5)
(19 6.4) 60° 1 (3.3)
6 )
(1 3.1 .8)
5 (1
4 (9 .5)
3 (6 .3)
2 (3
1 70° OMP
70° OMP
System operation Probe features
Prior to probe operation it is imperative to ensure that Stylus on-centre adjustment
the program selected to 'drive' the probe has been verified. Standard Optional
Incorrect programming could result in damage to the Translation screw adjusters Stylus on-centre adjustment
machine, workpiece and probe system. with Ø8 mm ball
The battery powered MP10 has two modes of operation. For applications where
1. Stand-by mode the stylus stem must be
To conserve battery life the probe is held in the stand-by parallel with the
mode, until the CNC control sends a start signal via the spindle centre line
OMM or OMI, to the OMP receiving diodes (Rx).
The start signal switches the probe to the operating mode.
2. Operating mode
During the operating mode, probe signals are transmitted
through 360° from the OMP transmitting LED's (Tx), to the
OMM or OMI for onward transmission to the CNC control. OMP
Optical module probe
PROBE SWITCH-ON
The probe is switched-on by one of the following options. Battery Transmitting LED
1. Manual start (6 x Tx)
(system with OMM + MI 12 only) Probe status LED
Initiated by pressing the MI 12 manual start button. (1 x red - green) Probe setting
+ options switch
2. Machine start (factory set to this option) Receiving diode
(system with OMM + MI 12 or system with OMI) (3 x Rx) - Selects switch-off mode
and switch-off time delay
Initiated by an M code generated by the program.
3. Auto start Probe head
(system with OMM + MI 12 or system with OMI)
Initiated by auto start signal sent every second. Stylus spring Weak link
PROBE SWITCH-OFF pressure adjustment
(optional)
The probe is switched-off by one of the following options.
1. Optical-on / timer-out (factory set to this option)
A timer automatically returns the probe to stand-by if the
probe has not been used for 33 seconds or 134 seconds Stylus
(factory set to 134 seconds).
2. Optical-on / optical-off
A second start signal is generated by a software M code,
which switches the probe off after 5 seconds or 9 seconds Shank manufacturing details
(factory set to 9 seconds).
6 (0.24) GAUGE
LINE
4.5 (0.18)
PROBE STATUS LED Ø20.10 (0.791) 4.3 (0.17)
The probe status LED gives a visual indication of the Ø20.02 (0.788)
probe state (triggered or seated). It also indicates 0.8 32
when the battery has become unuseable. Two holes
LED colour Probe status M8 x 1.25 thro.
equi-spaced
Flashing green Stylus seated
into bore Ø25.0 (0.984)
Flashing red Stylus deflected Ø24.8 (0.976)
Not convex
0.8 32
17.5°
Ø6 17.5°
(0.24)
21.5
(0.85) See Data sheet
V flange taper shank
taper shanks
Stylus 70° OMP 70° OMP 69.8 (2.75) to suit machine.
H-2000-2011
50 (1.96) long 46.4 (1.82) 35° OMP 67.9 (2.67) (available from Renishaw)
for dimensions
Other length 35° OMP Add 1.4 (0.06) if the A A
styli may be used 48.8 (1.92) ball is used GAUGE LINE
dimensions mm (in)
Renishaw plc T +44 (0)1453 524524
New Mills, Wotton-under-Edge, F +44 (0)1453 524901
Gloucestershire GL12 8JR E [email protected]
United Kingdom www.renishaw.com
Parts List - Please quote the Part no. when ordering equipment
Type Part No. Description
MP10 kit A-2033-1101 MP10 35° probe + battery, stylus, OMM, mounting bracket, MI 12 interface unit and tool kit.
MP10 kit A-2033-1102 MP10 70° probe + battery, stylus, OMM, mounting bracket, MI 12 interface unit and tool kit.
MP10 kit A-2115-0024 MP10 35° probe + battery, stylus, OMI, mounting bracket and tool kit.
MP10 kit A-2115-0025 MP10 70° probe + battery, stylus, OMI, mounting bracket and tool kit.
MP10 A-2033-1099 MP10 35° probe + battery, weak link stem, centre ball and tool kit - factory set to time out.
MP10 A-2033-1100 MP10 70° probe + battery, weak link stem, centre ball and tool kit - factory set to time out.
MP10 A-2033-1115 MP10 35° probe + battery, weak link stem, centre ball and tool kit - factory set to optical off.
MP10 A-2033-1116 MP10 70° probe + battery, weak link stem, centre ball and tool kit - factory set to optical off.
Stylus A-5000-3709 PS3-1C stylus Ø6 ball x 50mm long with ceramic shaft.
Weak link kit A-2085-0068 Kit comprising: two stylus weak link stems, spanner and instruction sheet.
Weak link stem M-2085-0069 Stylus weak link stem.
Spanner P-TL09-0003 Spanner for weak link stem.
Battery P-BT03-0001 PP3 9 V alkaline battery.
Styli — See Brochure H-1000-3200 Styli and accessories.
Shank — See Data Sheet H-2000-2011 Taper shanks.
OMM — See Data Sheet H-2000-2275 Optical module machine.
MI 12 — See Data Sheet H-2000-2195 MI 12 interface unit.
OMI — See Data Sheet H-2000-2285 Optical machine interface (alternative to OMM + MI 12).
PSU3 — See Data Sheet H-2000-2200 PSU3 power supply unit (optional).
Software — See Data Sheet H-2000-2289 Probe software for machine tools.