BQ Trade Code
BQ Trade Code
Clearing
Clearing General x Clear the site where directed by the Item
Engineer within the boundaries as shown in
Engineers drawing no. of all trees
(irrespective of tree girth), vegetation,
crops, loose vegetable matter, rubbish and
fencing and including grubbing up stumps
and tree roots and then removing from site
and fill up and level the original ground
level with earth to all voids, holes arising
out of the removal of tree stumps and
roots
Earthwork
Earthwork Exc&Fill Earth x Bulk excavation (inclusive cut and fill) to m3
the required platform levels, all as per
Engineer's drawing and fill in the excavated
materials to areas of filling and compact to
the required platform level all within the
boundary of the site including forming of
slopes all as per Engineer's drawing no.
Pile Bore Test Load 1.2m dia x Carry out preliminary load test for 1200mm No.
11310kN x 2 diameter bore pile utilising maintained load
test to 2.0 times of working load inclusive
load cell, strain gauge, extensometer etc.;
all as per Structural & Civil Engineer's
requirement and specification, and
subsequent PDA test as per instruction
(PDA test measured separately) (WL =
11310kN x 2.0)
Pile Bore Test PDA x dia Carry out PDA test (Piling Driving Analysis) No.
stress wave and particle velocity
measurement and data processing
complete with report for each test to be
submitted to Structural & Engineer
including mobilisation, subsequent
demobilisation and removal of all
equipment uopn completion
Pile Bore Test PI x dia Provide integrity testing of piles including No.
all necessary equipment, labour, etc and
perform single and shock test on various
diameter bored piles (Notes: Select from
piles not tested by PDA test)
Pile Bore Test Sonic x dia Provide and asemble a set of 4 numbers of No.
50mm dia.G.I pipes attached to
reinforcement with full length and carry
out cross sonic logging test on the following
bored piles. Rates including Grade 30 non-
shrink grout into G.I pipes
Pile Bore Bore Earth x dia Bore vertical holes from reduce level m
through whatever soil strata, including
whatever hard materials, get out and
remove surplus bored material from site
including temporary casing
Pile Bore Bore Rock x dia Extra over for bore only vertical holes for m
chiselling through rock including temporary
casing
Pile Bore Conc G? x Ready mixed reinforced vibrated concrete m3
Grade ? as described
Pile Bore Rebar T? High tensile steel bar reinforcement as kg
described
Pile Bore Steel Case x dia Steel Casing m
Pile PC Sq Pile Sq ? X ?m Precast Concrete Square Pile
Pile PC Sq Mob x Mobilisation, transporting, handling and Item
assembling piling frame, plant, equipment
and tools on and about site and their
subsequent removal from the site upon
completion of the Works
RC SUP Supper Drain 200 x 75mm Extra over for forming 200mm (W) x 75mm m
(D) scupper drain; including all necessary
formwork and finished in good
workmanship; complete all to Structural &
Civil Engineer's approval (Provisional)
RC SUP PC Pump Sump 1.2x1.2x1m Extra over for construct and complete of No.
precast concrete pump sump overall size
1200mm (L) x 1200mm (W) x 1000mm (D);
inclusive of all necessary excavation, lean
concrete, concrete, formwork and
reinforcement works; complete all to
Structural & Civil Engineer's approval; all as
per Structural & Civil Engineer's drawing
(Provisional)
RC SUP RC Sump Pit 1x1x0.6m Extra over for construct and complete of No.
reinforced concrete sump pit overall size
1000mm (L) x 1000mm (W) x 600mm (D);
inclusive of all necessary excavation,
concrete, formwork and reinforcement
works; complete all to Structural & Civil
Engineer's approval (Provisional)
RC SUP Opening 4" x 8" Extra Over for forming opening 4" x 8" No.
rebate including all necessary formwork
RC SUP Opening 0.6x0.6m Extra over for temporary boxing to form No.
oepning overall size 600mm x 600mm wide
RC SUP Opening 0.15 dia EXTRA OVER for forming 150mm diameter No.
holes to receive pipe sleeve; including all
necessary formwork (Provisional)
RC SUP Seal Lift Gap x Allow an item for sealing in the installed lift Item
door jamb with all necessary concrete,
reinforcement and formwork all to
Engineer's Approval and to achieve
minimum two hours fire rating
RC SUP Trimmer Bar x Allow an item for the trimmer bar to all Item
the opening for the shear wall,
reinforced concrete wall and non-load
bearing wall all as per Structural and Civil
Engineers's instruction
RC SUP Seal M&E Svs x Allow an item for sealing in slabs and walls Item
after the M&E services works installed with
all necessary concrete, reinforcement and
formwork all to Engineer's approval and to
achieve minimum two hours fire rating
RC SUP Seal M&E Svs x Allow an item for sealing in the installed lift Item
door jamb with all necessary concrete
reinforcement and formwork all to
Engineer's Approval and to achieve
minimum two hours fire rating
RC SUP Weep Hole 0.15m dia 150mm diameter UPVC Class B ware pipes No.
as weep holes at every 1.5m centre to
centre longitudinally and 1.5m centre to
centre vertically; built into wall with
approved end of 100g/m2 geotextile
wrapped surround with aggregates; all as
per Structural and Civil Engineer's detailed
drawing No. SNA001086/C/B7/RD/DT/01
RC SUP Subsoil Pipe 0.15m dia Supply and install 150mm diameter PVC m
Class B perforated sub-soil pipe and
300mm diameter aggregate wrapped
around with fabric membrane as filter
materials; all as per Structural and Civil
Engineer's drawing (Provisional)
RC SUP Trimmer Bar x Allow an item for the trimmer bar to all the Item
opening for the shear wall, reinforced
concrete wall and non-load bearing wall all
as per Engineer's instruction
Metal Works
Metal Works Cat Ladder 0.5x4.8m Supply and install stainless steel cat ladder No.
overall size 500mm x 4800mm high
(average) inclusive of all necessary fixing
accessories and fittings; complete all to
Architect's satisfaction and approval
Metal Works Alu Cover 0.6x0.6m Supply and install aluminium cover overall No.
size 600mm x 600mm wide inclusive of all
necessary fixing accessories and fittings;
complete all to Architect's satisfaction and
approval
Metal Works MS/SS Str Rail 0.9m High Supply and install staircase railing overall m
height 900mm; ….
Metal Works MS/SS Wall Rail 0.9m High Supply and install other MS/ Stainless Steel m
railing; ….
Metal Works Column Guard x Supply and install mild steel angle plate as No.
column guard; overall size 50mm x 50mm x
4mm thick 600mm long painted with
Enamel paint to specification as
described; including all necessary fixing
accessories; all as per Architect's detail
drawing
Metal Works Stage 2.0m High Construct and complete stage overall size Item
4000mm (L) x 2000mm (W) x 2000mm (H)
inclusive of all necessary installation, fixing,
painting, accessories and associated works,
all as per Architect's drawing
Metal Works Steel Grating x Supply and install light duty/ heavy No.
duty zinc galvanised steel grating/ hot dip
glavanised mild steel grating with….
Metal Works Rubbish Trap x Supply and install mild steel rubbish trap; No.
complete with mild steel grille of 12
diameter at 50 centre to centre all welded
together; including all necessary
accessories and fittings; all as per
Engineer's detailed drawing inclusive of all
necessary painting work
Metal Works Iron Steps x Construct and complete galvanised iron No.
steps at spacing 300mm c/c as shown in
the drawings with all necessary painting
work to Engineer's approval
Brickwork Sand Brick ?mm thk Sand bricks as described; in cement and m2
sand (1:3) mortar ditto
Brickwork DPC ?mm Bituminous felt damp-proof course as m
described; well lapped at joints on and
including 19mm bed of cement and sand
(1:3) mortar coated with hot bitumen
Brickwork Tie Rebar T? Supply and installation of tie bar to wall no.
and column
Blockwork
Blockwork AAC Block ?mm thk AAC light weight block wall m2
Blockwork Conc Block ?mm thk Concrete block wall m2
Blockwork Ventilation ?mm thk Precast Concrete ventilation block m2
Plastering
Plastering Ext/ Int ?mm thk Plastering; in cement and sand (1:3) with m2
approved plasticiser as described; finished
smooth with a wood trowel
Plastering Ext/ Int ?mm thk Plastering; in cement and sand (1:6) with m2
approved plasticiser applied in two coats;
finished smooth with a steel trowel
Plastering Ext/ Int ?mm thk Cement and sand mortar (1:3) rendering m2
finished with a steel towel as described
Skimcoat
Skimcoat Ext/ Int Wall & ?mm Lafarge-Quick Skim 388 or other approved m2
Column equivalent; trowelled smooth; applied
strictly in accordance with the
manufacturer's instructions; including
preparing and levelling substrate surface by
grinding or otherwise to receive the skim
coating
Screeding Angle Fillet x Angle fillet in cement and sand (1:3) lay m
along beam and wall/ floor joints to receive
waterproofing membrane including
necessary formwork
Screeding Str Landing ?mm thk Paving; in cement and sand (1:3); finishes m2
smooth with a steel trowel
Screeding Str Tread 350x?mm Ditto to 350mm wide stair tread m
thk
Screeding Str Riser 200x?mm Ditto to 200mm wide stair riser m
thk
Screeding Str Nose Bck 75x?mm thk Screeding in cement and sand (1:3) m
trowelled smooth to receive step nosing
tiles
Screeding Str Nose Tile 75x?mm thk Supply and installation of nosing tile m
Alu & Glass Ceiling Acess ?x?mm Aluminium ceiling access panel No.
Alu & Glass Ceiling Acess ?x?mm/ Extra over for the opening to alum ceiling No.
?mm dia panel
FRP Door
FRP Door Louvres D? ?x?m Supply, delivery and install composite No.
louvres blades with anti-vermin wire
netting fixed inside; including supports,
fixing accessories, complete with approved
material, approved friction stays and
complete all necessary ironmongery and
accessories; packing around and into
frames with cement mortar and sealing
joints around edges of frames with
approved silicone sealant and fixed
complete in position all in accordance to
manufacturer's details and Architect's
drawings and schedule of materials
Timber Door
Timber Door Metal Frame ?x?m Supply, delivery and install metal door No.
frame with 1.2mm thick hot dip
galvanished framed with architrave
inclusive of 102mm x 76mm x 2mm thick
stainless steel hinges and galvaneal finish
painting all to manufacturer's details
(inclusive 3 Nos. 12mm diameter steel bar
if necessary)
Timber Door Timber Frame ?x?m Supply, delivery and install timber door No.
frame…
Timber Door Hlw D? ?x?m Wrot and frame pressure-treated Group B No.
timber "skeleton frame" hollow core flush
doors and panels; faced both sides with
4.8mm-5.2mm thick plywood and
laminated both sides; all as per Architect's
drawing
Timber Door Hlw WP D? ?x?m Ditto. and internal side with 4.8mm - No.
5.2mm thick waterproof plywood and
laminated both sides; all as per Architect's
drawing
Timber Door Louvres D? ?x?m Wrot and frame pressure-treated klin dried No.
hardwood Belau timber fixed louvred door,
all as per Architect's detail drawings and
approval
Timber Door Slide WP D? ?x?m Timber sliding door; complete with No.
selected veneered lamination and all
necessary ironmongery and accessories; all
as per Architect's detailed drawing
Timber Door Slide Pelm D? ?x?m To supply and install approved "Nyatoh" No.
pelmet finished with varnish for sliding
timber door; all as per Architect's approval
and detailed drawing
Ceiling Gyp Opening 0.15m dia Extra Over for forming 150mm diameter No.
opening for downlight fittings including all
necessary extra framing and trimming
(position to be adjusted on site)
(Provisional)
Ceiling Gyp Access 0.6x0.6m Extra Over for forming 600mm x 600mm No.
access panel including all necessary extra
framing and trimming (position to be
adjusted on site) (Provisional)
Ceiling Plas Panel 9mm thk 9mm Thick plaster ceiling m2
board as described or other approved
equivalent; ….
Ceiling MR Plas Panel 9mm thk 9mm Thick moisture resistance m2
plaster ceiling board as described or other
approved equivalent; ….
Ceiling Plas Access 0.6x0.6m Extra Over for forming 600mm x 600mm No.
access panel including all necessary extra
framing and trimming (position to be
adjusted on site) (Provisional)
Ceiling 2hr FR/ Grid 0.6x0.6m Extra Over for forming 600mm x 600mm No.
Acess access panel including all necessary extra
framing and trimming (position to be
adjusted on site) (Provisional)
Paint Ext Silicone Paint x Prepare and apply externally silicone paint m2
Paint Int
Paint Int Emulsion x Prepare and apply internally "Jotun" paint m/ m2
system comprising one coat of Basecoat
Sealer "low VOC modified acrylic sealer"
and two finishing coats of Jotaplast Max
"Low Voc acrylic paint or approved
equivalent paint of approved colour;
applied strictly in accordance with the
manufacturer's specification and
instructions
Paint Int Gloss Enamel x Knot, prime, stop and apply one undercoat m/ m2
and two finishing coats of 'Jotun Gloss
Finish' or approved equivalent synthetic
gloss enamel paint on woodwork
Paint Int Gloss Enamel x Prepare and apply "Jotun" paint system m2
comprising one coat of Jotamatt "alkyd
undercoat" and two finishing coats of
Gardex Gloss/ Semi Gloss "fungus resisting
alkyd paint" or approved equivalent of
approved colours as described to metal
surfaces; applied strictly in accordance with
the manufacturer's specification and
instructions
Tiling
Tiling Screeding ? mm thick Screeding to receive floor tiles m/m2
Tiling Str Step Nosing 300x75x8mm Supply and lay 300mm x 75mm x 8mm m/m2
thick (average) Niro step nosing tile or
other approved equivalent to Architect's
selection; …
Tiling Flr 300x300x8m Supply and lay 300mm x 300mm x 8mm m/m2
(Code/Supply m thick (average) Niro matt homogenous tile
rate) or other approved equivalent to Architect's
E.g. Flr T1a or selection
Flr S67.15/m2
Stone
Stone Screeding ? mm thick Screeding to receive marble flooring m/ m2
Stone Flr ?x? mm Supply and lay selected 600mm x 600mm m2
(Code/Supply marble or other approved equivalent to
rate) Architect's selection; lay with Mapei or
E.g. Flr T1a or Davco or approved equivalent high
Flr S67.15/m2 performance cementitious adhesive
conform to Class C2Te in compliance with
ISO 130007-1 standard onto 20mm thick
(average) in waterproofed cement and
Stone Plastering ? mm thick Plastering to receive wall mable m/ m2
Stone Wall ?x? mm Supply and lay 600mm x 600mm marble or m2
(Code/Supply other approved equivalent to Architect's
rate) selection; lay with Mapei or Davco or
E.g. Wall T1a or approved equivalent high performance
Wall S67.15/m2 cementitious adhesive conform to Class
C2Te in compliance with ISO 130007-1
standard into 13mm thick (average) in
waterproofed cement and sand (1:3)
Sanitary
Sanitary Ware x Sanitary Ware: SORENTO FORTE No.
BBSRTWC8319-UF one piece water closet
Sanitary Ware x Sanitary Ware: SORENTO BBSRTWB1411 No.
counter top basin
Sanitary Ware x Sanitary Ware: SORENTO BBCL905 ceramic No.
wall hung disabled basin single pre-
punched taphole
Sanitary Ware x Sanitary Ware: SORENTO BBCKS1050 No.
stainless steel single bowl single drainer
kitchen sink complete with stainless steel
top waste, plug and chain and bottle trap
or other approved equivalent
Sanitary Shower Screen ??x?? Supply and install shower screen No.
comprising 2 fixed glass panel with 1
frameless swing door in 10mm thick
tempered glass
Counter Top Acrylic ??x??x?? Construct and complete 600mm x 900mm No.
height counter top complete with …..
ACRYLIC BOARD finishes to top and side of
counter top …..
Waterproof
Waterproof IDROCRETE x Prepare and dose "Mapei" IDROCRETE WP, m3
pore - blocking hydrophobic waterproofing
admixture …
Waterproof MAPELASTIC x Supply and apply 1 layer of MAPEI m2
MAPELASTIC FOUNDATION in 2 coats at
1.7kg/m2/coat waterproofing membrane;
…
Waterproof MAPEFILL 318 300mm 300mm high skirting with top tucked and m
sealed into and including groove in
concrete or brickwork and bottom dressed
over and complete with MAPEFILL 318 non-
shrink mortar as angle fillet
Waterproof Fosroc Nitoprf 200x50mm Extra Over for 200mm x 50mm deep m
scupper drain
Waterproof Fosroc Nitoprf 150mm dia Extra Over for working around the 150m No.
diameter rain water down pipe
Waterproof Waterstop V- x To supply and install SIKA-WATERBAR V- m
20L 20L water stop …
Waterproof Waterstop x Supply and lay one (1) layer of Volclay m
Rx101 Waterstop-RX 101 swellable waterstop to
all the proper prepared construction
joint, all in accordance with manufacturer's
instruction
Flr Hardener
Flr Hardener MAPETOP SP 4kg/m2 To supply and lay "Mapei" MAPETOP SP m2
non-metalic surface harderner or other
equal and approved equivalent material;
applied at rate 4kg/m2 laid monolithically
trowelled to be desired finish and cure with
"Mapei" MAPECURE SP curing compound
as described; all scope of work done strictly
by approved applicator in accordance with
manufacturer's printed instrcutions and
recommendations
Conc Imprint
Conc Imprint Base Conc 30mm thk Supply and lay selected tecture concrete m2
finish as describe and to Architect's
selection; …
Conc Imprint Fin Conc 4-5mm thk Supply and lay 4-5mm thick selected m2
Texture concrete finish (Seamless Texture
Concrete Imprint)
Epoxy Flr
Epoxy Flr Deckrete SF 0.3mm thk To supply and apply 1 layer of Deckrete SF m2
or other approved equivalent solvent free
epoxy color coating at 0.3mm thick onto
cement render surface; all in accordance
to manufacturer's specification and
instruction
Post Tension
Post Tension Beam/ Slab x ? ? m2 (Area) Design, fee and paid post tensioning Item
kg/m2 system to slab; including anchorage
devices, ducts, bar chair, grouting, tendon
support bar for profiling, patching back,
tensioning strictly to the required effective
force as described in Structural and Civil
Engineer's drawing (Cont'd)
Vinyl Flr
Vinyl Flr Screed Backing ?mm thk Supply and lay Ardex CL11 or other m2
approved equivalent self-levelling
underlayment screed including primer all in
accordance to manufacturer's specification
and instruction
Vinyl Flr Flr 3mm thk Supply and lay 3mm thick (min) vinyl m2
(Code/Supply flooring; laid to floor with acrylic adhesive
rate) as described inclusive of heat welding rod
E.g. Flr T1a or all seams and joint in welding rod of
Flr S51.00/m2 matching; contrast in colour and pattern to
be selected and approved by the Architect;
all in accordance to manufacturer's
specification and instruction
Timber Flr
Timber Flr Screed Backing ?mm thk Supply and lay screed including primer all in m2
accordance to manufacturer's specification
and instruction
Timber Flr Flr x Approved timber flooring to architect's m2
(Code/Supply specification; …
rate)
E.g. Flr T1a or
Flr S215.05/m2
Carpet Flr
Carpet Flr Screed Backing ?mm thk Supply and lay screed including primer all in m2
accordance to manufacturer's specification
and instruction
Carpet Flr Flr x Approved carpet flooring to architect's m2
(Code/Supply specification; complete with selected
rate) rubber underlay to architect's approval; …
E.g. Flr T1a or
Flr S215.05/m2
Sewerage
Sewerage Excavation 1.0 - 1.5m Excavate trench all material for depth m
exceeding 1.00m but not exceeding 1.50m
for the purpose of laying 300mm diameter
sewer pipe works.
Sewerage Manhole Cover 840x 840x Supply and install 840mm x 840mm x No.
20mm thk 20mm thick approved hinged heavy duty
ductile iron manhole cover and frame to
B.S.497 …
Sewerage Local Fees x Allow an item for paying all relevant fees to Item
Local Authorities to get approval for laying
pipes and upon completion of the
sewerage works; including inspection
associated therewith
Drain PC
Drain PC Excavation ?-?m Excavate trench all material for precast m
concrete drain
Drain PC Backfill ? w X ? thk Selected and approved aggregate of size m
20mm as described spread, levelled and
well compacted including selected and
approved backfilling material well
compacted to finish ground level as shown
in the drawing no.
Drain PC Pipe Culvert D5 0.6m Supply and lay precast reinforced concrete m
pipe culvert (Type D5) HUME Class 'Z' or
equivalent product complaying to BS556 as
described; …
Drain Earth
Drain Earth Excavation ?-?m Excavate trench all material for precast m
concrete drain
Drain Earth Backfill ? w X ? thk Selected and approved aggregate of size m
20mm as described spread, levelled and
well compacted including selected and
approved backfilling material well
compacted to finish ground level as shown
in the drawing no.
Drain Subsoil
Drain Subsoil Excavation ?-?m Excavate trench all material for precast m
concrete drain
Drain Subsoil Backfill ? w X ? thk Selected and approved aggregate of size m
20mm as described spread, levelled and
well compacted including selected and
approved backfilling material well
compacted to finish ground level as shown
in the drawing no.
Landscape Root Barrier x Provide 18” height tree root barrier using No.
polyethalene with deflector root for
Lagerstromea florirunda and Salix
BAbylonica ( hujan-hujan) as per Architect’s
drawing no
Retaining Wall
Roof
Roof