Lube Oil
Paper Machine
CJC™ Application Study
CUSTOMER
Application Study Norske Canada, Elk Falls Division in Campbell
written by: River, BC, Canada.
Rick Klassen
THE SYSTEM
Klassen Hydraulics Inc. Machine type:
Canada Paper machine bowser lube system.
Oil type: 12,000 litres of Chevron CLARITY 220
2004 ISO VG220.
THE PROBLEM
Poor oil quality led to a reduction in the bearing
life expectancy. Initial ISO code was 22/21/18
(2/5/15 μm); target cleanliness level was set at
19/16/13. Water ingress was also a problem,
though they already had a vacuum dehydrator
installed to help dry the oil.
THE SOLUTION
CJC™ Fine Filter HDU 2*27/108 GP, Norske Canada
A CJC™ Fine Filter HDU 2*27/108 GP-EPT
was selected to bring the oil down to the target
cleanliness level. This unit was fitted with a
GP-33-4 pump at a flow of 3,200 litres/hour. We OIL ANALYSIS
chose a CJC™ Filter Insert BLA 27/27 for its
ability to handle excessive water concentration.
Particle Count vs Time
THE TEST 30,000
Oil samples were taken prior to installation, and 2 Micron
sent to the laboratory for analysis. Samples 25,000
5 Micron
Particles in 1 ml
were then taken at regular intervals, and the re- 20,000
sults compared.
15,000
THE RESULT 10,000
The sample results show a dramatic improve-
ment in the first three months; particulate levels 5,000
15 Micron
dropped to 18/17/14 as the oil quality improved.
The subsequent months show a more gradual im- 0
Mar-16 Jun-05 Apr-05 Jun-22
provement, highlighting CJC’s ability to actually 2003 2003 2004 2004
clean the inside surfaces of the lube oil system
(valves, hoses, etc.) by circulating clean oil. The
most recent laboratory results indicated an ISO THE RESULT
code of 16/14/11, roughly 1/100th of the initial
particle count. Sample Mar-16 Jun-05 Apr-05 Jun-22
Date 2003 2003 2004 2004
ISO Code 22/21/18 18/17/14 18/16/13 16/14/11
ASIN5062-UK C.C.JENSEN A/S
Paper & Pulp Løvholmen 13 DK-5700 Svendborg Denmark
23.03.2000 Phone: +45 6321 2014 Fax: +45 6222 4615
[email protected] www.cjc.dk