Ribbon Cable connector Compliant with MIL Standard

HIF3B Series

■Features
1. Product Compliant with MIL Standard
HIF3B series has been developed as a product compliant with MIL
standard, and used for wide applications.

2. UL Approval Product
HIF3B series connectors are UL approved.

3. Mechanism to Prevent Mis-insertion


This connector is equipped with the mechanism to prevent Mis-
Nov.1.2021 Copyright 2021 HIROSE ELECTRIC CO., LTD. All Rights Reserved.

insertion as follows.
1 The system provides the convex area to insert the guide-key on the
pin header side, and to guide it in combination with the socket
convex area (MIL standard).
2 The system embeds and guides the polarizing key in the socket holes.

4. Applicable Cable 28 AWG (IDC type)


The applicable cable is UL2651 28 AWG flat cable
(7cores./0.127mm, jacket dia. 0.9±0.1mm).

■Product Specifications
Current rating : Operating Temperature Range : Storage Temperature Range :
IDC : 1A 28 AWG Crimp : 32, 36 AWG : 1A Other : 3A –55 to +85ç (Note 1) –10 to +60ç (Note 2)
Rating
Voltage rating : Operating Moisture Range : Storage Humidity Range :
200V 40 to 80% 40 to 70% (Note 2)

Item Specification Condition


1. Insulation Resistance 1000Mø min. 500V DC
2. Withstanding voltage No flashover or insulation breakdown. 650V AC/1 minute
3. Contact Resistance 15mø max. 0.1A
4. Vibration No electrical discontinuity of 1μs or more Frequency : 10 to 55 Hz, single amplitude of 0.75 mm, 2 hours in each of the 3 directions.
5. Humidity (Steady state) Insulation resistance : 1000Mø min. 96 hours at temperature of 40ç and humidity of 90% to 95%
(-55ç : 30 minutes ➝ 15 to 35ç : 5 minutes max.
6. Temperature Cycle No damage, cracks, or parts looseness.
125ç : 30 minutes ➝ 15 to 35ç : 5 minutes max.) 5 cycles
7. Durability (Mating/un-mating) Contact resistance : 15mø max. 500 cycles
Solder bath : 260ç for 10 seconds
8. Resistance to Soldering heat No deformation of components affecting performance.
Manual soldering : 360ç for 5 seconds
Note 1 : Includes temperature rise caused by current flow.
Note 2 : The term "storage" refers to products stored for long period of time prior to mounting and use. Operating Temperature Range and
Humidity range covers non conducting condition of installed connectors in storage, shipment or during transportation.
Note 3 : Information contained in this catalog represents general requirements for this Series. Contact us for the drawings and specifications for a
specific part number shown.
Note 4 : Please note that there is a risk of deforming the lock when an excessive load is applied to the inside.

■Material / Finish
Part Material Finish Remarks
Insulator PBT Black UL94V-0
Socket Contact Beryllium copper Connection area Gold plated –––––––
Pin header contact Brass Selective Gold plated –––––––

B15
HIF3B Series●Ribbon Cable connector Compliant with MIL Standard

■Product Number Structure


Refer to the chart below when determining the product specifications from the product number.
Please select from the product numbers listed in this catalog when placing orders.

●Socket

HIF 3B - * D - 2.54 R
q w e r t y

q Series Name : HIF


w Series No. : 3B, 3BA, 3BB (50, 60, 64 contacts only)
e Number of contacts : 6,10,14,16, 20, 26, 30, 34, 40, 50, 60, 64
r Contact alignment : D : Double
Nov.1.2021 Copyright 2021 HIROSE ELECTRIC CO., LTD. All Rights Reserved.

t Contact pitch : 2.54mm


y Connection type
R : ID type

●Pin Header

HIF 3B - * P A - 2.54 DS
q w e r t y u

q Series Name : HIF


w Series No. :
3B : (14 contacts not included) 3BC : (10 contacts only)
3BA, 3BB : (50, 60, 64 contacts only) 3BD : (10 contacts only)
e Number of contacts : 6,10,14,16, 20, 26, 30, 34, 40, 50, 60, 64
r P : Pin header
t A : Selective gold plated
y Contact pitch : 2.54mm
u Contact style
DS : Right angle type
DSA : Straight type

B16
HIF3B Series●Ribbon Cable connector Compliant with MIL Standard

■Socket (With guide to prevent mis-insertion)


Nov.1.2021 Copyright 2021 HIROSE ELECTRIC CO., LTD. All Rights Reserved.

Body Protector Clamp

Note1, Note2 : The number of polarizing keys and polarizing keyways changes according to products. Refer to the list as shown below.
Note3 : The 50, 60 and 64 contact connector contain two types of polarizing guides. Use the products, referring to Notes 1 and 2.
Note4 : The 6 contact has no polarizing mark.

Unit : mm
Polarizing Guide Polarizing Keyway
Part No. HRS No. No. of Contacts A B C D RoHS
(Note 1) (Note 2)
HIF3BA- 6D-2.54R(63) 610-0032-3 63 6 12.19 5.08 6.35 7.72 None
HIF3BA-10D-2.54R(63) 610-0021-7 63 10 17.27 10.16 11.43 12.8
One on left side
★ HIF3BA-14D-2.54R(63) 610-0022-0 63 14 22.35 15.24 16.51 17.88
★ HIF3BA-16D-2.54R(63) 610-0023-2 63 16 24.89 17.78 19.05 20.42
★ HIF3BA-20D-2.54R(63) 610-0024-5 63 20 29.97 22.86 24.13 25.5 One at center
★ HIF3BA-26D-2.54R(63) 610-0025-8 63 26 37.59 30.48 31.75 33.12
★ HIF3BA-30D-2.54R(63) 610-0026-0 63 30 42.67 35.56 36.83 38.2
YES
★ HIF3BA-34D-2.54R(63) 610-0027-3 63 34 47.75 40.64 41.91 43.28
★ HIF3BA-40D-2.54R(63) 610-0028-6 63 40 55.37 48.26 49.53 50.9 One on right and
★ HIF3BA-50D-2.54R(63) 610-0029-9 63 50 68.07 60.96 62.23 63.6 One on right and left sides, resp. left sides, resp.
★ HIF3BB-50D-2.54R(63) 610-0041-4 63 50 68.07 60.96 62.23 63.6 One at center
★ HIF3BA-60D-2.54R(63) 610-0030-8 63 60 80.77 73.66 74.93 76.3 One on right and left sides, resp.
★ HIF3BB-60D-2.54R(63) 610-0042-7 63 60 80.77 73.66 74.93 76.3 One at center
★ HIF3BA-64D-2.54R(63) 610-0031-0 63 64 85.85 78.74 80.01 81.38 One on right and left sides, resp.
★ HIF3BB-64D-2.54R(63) 610-0043-0 63 64 85.85 78.74 80.01 81.38 One at center
The products marked with ★ comply with MIL standard.

B17
HIF3B Series●Ribbon Cable connector Compliant with MIL Standard

■Socket
Nov.1.2021 Copyright 2021 HIROSE ELECTRIC CO., LTD. All Rights Reserved.

Body Protector Clamp

Note1 : The number of polarizing keys and polarizing keyways changes according to products. For details, refer to the list as shown below.
Note2 : The 6 contact has no polarizing mark.

Unit : mm
Polarizing Guide
Part No. HRS No. No. of Contacts A B C D RoHS
(Note 1)
HIF3B- 6D-2.54R(63) 610-0012-6 63 6 12.19 5.08 6.35 7.72 None
★ HIF3B-10D-2.54R(63) 610-0001-0 63 10 17.27 10.16 11.43 12.80
One on left side
★ HIF3B-14D-2.54R(63) 610-0002-2 63 14 22.35 15.24 16.51 17.88
★ HIF3B-16D-2.54R(63) 610-0003-5 63 16 24.89 17.78 19.05 20.42
★ HIF3B-20D-2.54R(63) 610-0004-8 63 20 29.97 22.86 24.13 25.50
★ HIF3B-26D-2.54R(63) 610-0005-0 63 26 37.59 30.48 31.75 33.12 YES
★ HIF3B-30D-2.54R(63) 610-0006-3 63 30 42.67 35.56 36.83 38.2 One on right and
★ HIF3B-34D-2.54R(63) 610-0007-6 63 34 47.75 40.64 41.91 43.28 left sides, resp.
★ HIF3B-40D-2.54R(63) 610-0008-9 63 40 55.37 48.26 49.53 50.90
★ HIF3B-50D-2.54R(63) 610-0009-1 63 50 68.07 60.96 62.23 63.6
★ HIF3B-60D-2.54R(63) 610-0010-0 63 60 80.77 73.66 74.93 76.3
★ HIF3B-64D-2.54R(63) 610-0011-3 63 64 85.85 78.74 80.01 81.38
The products marked with ★ comply with MIL standard.

B18
HIF3B Series●Ribbon Cable connector Compliant with MIL Standard

■Four Wall Angle Through hole


Nov.1.2021 Copyright 2021 HIROSE ELECTRIC CO., LTD. All Rights Reserved.

BPCB mounting pattern

Note 1, Note 2 : The number of polarizing slot and key installed positions
changes according to products. Refer to the list as shown below.
Note 3 : The spacer moves to the right according to the number of
contacts.
Note 4 : The 10, 50, 60 and 64 contact connectors contain two types of
■n=number of contacts polarizing slots.
Use products, referring to (Note 1) (Note 2).

Unit : mm
Polarizing Slot Polarizing Key Install
Part No. HRS No. No. of Contacts A B C D E F RoHS
(Note 1) (Note 2)
★ HIF3BA-10PA-2.54DS(63) 610-0091-2 63 10 32.0 17.5 10.16
28.14
MAX51.1 21.8 27.9 None One on right side
28.14
HIF3BD-10PA-2.54DS(63) 610-0171-0 63 10 32.0 17.5 10.16 MAX51.1 21.8 27.9 None
★ HIF3BA-14PA-2.54DS(63) 610-0092-5 63 14 37.1 22.6 15.24
33.24
MAX56.2 26.9 33.0 One on right side
★ HIF3BA-16PA-2.54DS(63) 610-0093-8 63 16 39.6 25.1 17.78
35.74
MAX58.7 29.5 35.5
★ HIF3BA-20PA-2.54DS(63) 610-0094-0 63 20 44.7 30.2 22.86
40.84
MAX63.8 34.5 40.6
One at center
★ HIF3BA-26PA-2.54DS(63) 610-0095-3 63 26 52.3 37.8 30.48
48.44
MAX71.4 42.2 48.3
★ HIF3BA-30PA-2.54DS(63) 610-0096-6 63 30 57.4 42.9 35.56
53.54
MAX76.5 47.2 53.3
YES
★ HIF3BA-34PA-2.54DS(63) 610-0097-9 63 34 62.5 48.0 40.64
58.64
MAX81.6 52.3 58.4
★ HIF3BA-40PA-2.54DS(63) 610-0098-1 63 40 70.1 55.6 48.26
66.24
59.9 66.0
MAX89.2 One on right and
★ HIF3BA-50PA-2.54DS(63) 610-0099-4 63 50 82.8 68.3 60.96
78.94
MAX101.9 72.6 78.7 One on right and left sides, resp. left sides, resp.
★ HIF3BB-50PA-2.54DS(63) 610-0131-5 63 50 82.8 68.3 60.96
78.94
MAX101.9 72.6 78.7 One at center
★ HIF3BA-60PA-2.54DS(63) 610-0100-1 63 60 95.5 81.0 73.66
91.64
MAX114.6 85.3 91.4 One on right and left sides, resp.
★ HIF3BB-60PA-2.54DS(63) 610-0132-8 63 60 95.5 81.0 73.66
91.64
MAX114.6 85.3 91.4 One at center
★ HIF3BA-64PA-2.54DS(63) 610-0101-4 63 64 100.6 86.1 78.74
96.74
MAX119.7 90.4 96.5 One on right and left sides, resp.
★ HIF3BB-64PA-2.54DS(63) 610-0133-0 63 64 100.6 86.1 78.74
96.74
MAX119.7 90.4 96.5 One at center
The products marked with ★ comply with MIL standard.

B19
HIF3B Series●Ribbon Cable connector Compliant with MIL Standard

■Four-Wall Straight Through hole


Nov.1.2021 Copyright 2021 HIROSE ELECTRIC CO., LTD. All Rights Reserved.

BPCB mounting pattern

Note 1, Note 2 : The number of polarizing slot and key installed positions
changes according to products. Refer to the list as shown below.
Note 3 : The spacer moves to the right according to the number of
contacts.
■n=number of contacts Note 4 : The 10, 50, 60 and 64 contact connectors contain two types of
polarizing slots.
Use products, confirming (Note 1) (Note 2).
Note 5 : The 6 contact has no polarity mark.

Unit : mm
Polarizing Slot Polarizing Key Install
Part No. HRS No. No. of Contacts A B C D E F RoHS
(Note 1) (Note 2)
★ HIF3-6PA-2.54DSA(71) 562-0503-9 71 6 26.92 12.42 05.08
23.06
MAX46.02 16.7 22.82 One at center None
28.14
HIF3BA-10PA-2.54DSA(63) 610-0111-8 63 10 32.0 17.5 10.16 MAX51.1 21.8 27.9 None One on right side
★ HIF3BD-10PA-2.54DSA(63) 610-0181-3 63 10 32.0 17.5 10.16
28.14
MAX51.1 21.8 27.9 None
★ HIF3BA-14PA-2.54DSA(63) 610-0112-0 63 14 37.1 22.6 15.24
33.24
MAX56.2 26.9 33.0 One on right side
★ HIF3BA-16PA-2.54DSA(63) 610-0113-3 63 16 39.6 25.1 17.78
35.74
MAX58.7 29.5 35.5
★ HIF3BA-20PA-2.54DSA(63) 610-0114-6 63 20 44.7 30.2 22.86
40.84
MAX63.8 34.5 40.6
One at center
★ HIF3BA-26PA-2.54DSA(63) 610-0115-9 63 26 52.3 37.8 30.48
48.44
MAX71.4 42.2 48.3
★ HIF3BA-30PA-2.54DSA(63) 610-0116-1 63 30 57.4 42.9 35.56
53.54
MAX76.5 47.2 53.3
YES
★ HIF3BA-34PA-2.54DSA(63) 610-0117-4 63 34 62.5 48.0 40.64
58.64
MAX81.6 52.3 58.4
★ HIF3BA-40PA-2.54DSA(63) 610-0118-7 63 40 70.1 55.6 48.26
66.24
59.9 66.0
MAX89.2 One on right and
★ HIF3BA-50PA-2.54DSA(63) 610-0119-0 63 50 82.8 68.3 60.96
78.94
MAX101.9 72.6 78.7 One on right and left sides, resp. left sides, resp.
★ HIF3BB-50PA-2.54DSA(63) 610-0141-9 63 50 82.8 68.3 60.96
78.94
MAX101.9 72.6 78.7 One at center
★ HIF3BA-60PA-2.54DSA(63) 610-0120-9 63 60 95.5 81.0 73.66
91.64
MAX114.6 85.3 91.4 One on right and left sides, resp.
★ HIF3BB-60PA-2.54DSA(63) 610-0142-1 63 60 95.5 81.0 73.66
91.64
MAX114.6 85.3 91.4 One at center
★ HIF3BA-64PA-2.54DSA(63) 610-0121-1 63 64 100.6 86.1 78.74
96.74
MAX119.7 90.4 96.5 One on right and left sides, resp.
★ HIF3BB-64PA-2.54DSA(63) 610-0143-4 63 64 100.6 86.1 78.74
96.74
MAX119.7 90.4 96.5 One at center
The products marked with ★ comply with MIL standard.

B20
HIF3B Series●Ribbon Cable connector Compliant with MIL Standard

■Three Wall Angle Type


Nov.1.2021 Copyright 2021 HIROSE ELECTRIC CO., LTD. All Rights Reserved.

BPCB mounting pattern

Note 1, Note 2 : The number of polarizing slot and key installed positions
changes according to products. Refer to the list as shown below.
Note 3 : The spacer moves according to the number of contacts.
Note 4 : The 10 contact connector consists of two types.
Use products, confirming (Note 1) (Note 2).
■n=number of contacts

Unit : mm
Polarizing Slot Polarizing Key Install
Part No. HRS No. No. of Contacts A B C D E F RoHS
(Note 1) (Note 2)
★ HIF3BD-10PA-2.54DS(63) 610-0051-8 63 10 32.0 17.5 10.16
28.14
MAX51.1 21.8 27.9 None One on right side
28.14
HIF3BC-10PA-2.54DS(63) 610-0151-2 63 10 32.0 17.5 10.16 MAX51.1 21.8 27.9 None
★ HIF3BD-16PA-2.54DS(63) 610-0052-0 63 16 39.6 25.1 17.78
35.74
MAX58.7 29.5 35.5
★ HIF3BD-20PA-2.54DS(63) 610-0053-3 63 20 44.7 30.2 22.86
40.84
MAX63.8 34.5 40.6
★ HIF3BD-26PA-2.54DS(63) 610-0054-6 63 26 52.3 37.8 30.48
48.44
MAX71.4 42.2 48.3 One at center
★ HIF3BD-30PA-2.54DS(63) 610-0055-9 63 30 57.4 42.9 35.56
53.54
47.2 53.3 YES
MAX76.5 One on right and
★ HIF3BD-34PA-2.54DS(63) 610-0056-1 63 34 62.5 48.0 40.64
58.64
MAX81.6 52.3 58.4 left sides, resp.
★ HIF3BD-40PA-2.54DS(63) 610-0057-4 63 40 70.1 55.6 48.26
66.24
MAX89.2 59.9 66.0
★ HIF3BD-50PA-2.54DS(63) 610-0058-7 63 50 82.8 68.3 60.96
78.94
MAX101.9 72.6 78.7
★ HIF3BD-60PA-2.54DS(63) 610-0059-0 63 60 95.5 81.0 73.66
91.64
MAX114.6 85.3 91.4 One on right and left sides, resp.
★ HIF3BD-64PA-2.54DS(63) 610-0060-9 63 64 100.6 86.1 78.74
96.74
MAX119.7 90.4 96.5
The products marked with ★ comply with MIL standard.

B21
HIF3B Series●Ribbon Cable connector Compliant with MIL Standard

■Four Wall Straight Through hole


[Flux Blister Prevention Type]
Nov.1.2021 Copyright 2021 HIROSE ELECTRIC CO., LTD. All Rights Reserved.

BPCB mounting pattern

Note1 : The number of polarizing slot and key installed positions changes
according to products. Refer to the list as shown below.

■n=number of contacts

Unit : mm

Part No. HRS No. No. of Contacts A B C D E F Polarizing Slot Polarizing Key Install RoHS

★ HIF3CA-10PA-2.54DSA(63) 610-0701-1 63 10 32.0 17.5 10.16


28.14
MAX51.1 21.8 27.9 None One on right side
28.14
HIF3CD-10PA-2.54DSA(63) 610-0722-1 63 10 32.0 17.5 10.16 MAX51.1 21.8 27.9 None
★ HIF3CA-16PA-2.54DSA(63) 610-0703-7 63 16 39.6 25.1 17.78
35.74
MAX58.7 29.5 35.5
★ HIF3CA-20PA-2.54DSA(63) 610-0704-0 63 20 44.7 30.2 22.86
40.84
MAX63.8 34.5 40.6
★ HIF3CA-26PA-2.54DSA(63) 610-0705-2 63 26 52.3 37.8 30.48
48.44
MAX71.4 42.2 48.3 One at center
★ HIF3CA-30PA-2.54DSA(63) 610-0706-5 63 30 57.4 42.9 35.56
53.54
MAX76.5 47.2 53.3 YES
★ HIF3CA-34PA-2.54DSA(63) 610-0707-8 63 34 62.5 48.0 40.64
58.64
52.3 58.4
MAX81.6 One on right and
★ HIF3CA-40PA-2.54DSA(63) 610-0708-0 63 40 70.1 55.6 48.26
66.24
MAX89.2 59.9 66.0 left sides, resp.
★ HIF3CA-50PA-2.54DSA(63) 610-0709-3 63 50 82.8 68.3 60.96
78.94
MAX101.9 72.6 78.7 One on right and left sides, resp.
★ HIF3CB-50PA-2.54DSA(63) 610-0721-9 63 50 82.8 68.3 60.96
78.94
MAX101.9 72.6 78.7
★ HIF3CB-60PA-2.54DSA(63) 610-0723-4 63 60 95.5 81.0 73.66
91.64
MAX114.6 85.3 91.4 One at center
★ HIF3CB-64PA-2.54DSA(63) 610-0724-7 63 64 100.6 86.1 78.74
96.74
MAX119.7 90.4 96.5
The products marked with ★ comply with MIL standard.

B22
HIF3B Series●Ribbon Cable connector Compliant with MIL Standard

BPolarizing Key

HIF3B-GK
562-0601-8
Nov.1.2021 Copyright 2021 HIROSE ELECTRIC CO., LTD. All Rights Reserved.

HIF3-GPIN(A) HIF3BA-GPIN

Note1 : One unit of this Note1 : One unit of this


product is a set of five product is a set of five
pieces in conjunction pieces in conjunction
with a runner. The with a runner. The
unit for sale is defined unit for sale is defined
one pack containing one pack containing
20 pieces. 20 pieces.
Note2 : This product is Note2 : This product is
applicable to HIF3A- applicable to the
*D2.54R, HIF3C- HIF3BA-*D2.54R
*D2.54C and product.
HIF3BA-*D2.54C
products.

Part No. HRS No. Material Remarks RoHS Part No. HRS No. Material Remarks RoHS
HIF3-GPIN(A) 562-0126-6 Poly acetal (white) A set of 5 pieces YES HIF3BA-GPIN 612-0500-2 Poly acetal (white) A set of 5 pieces YES

B23
HIF3B Series●Ribbon Cable connector Compliant with MIL Standard

BLock
●Low Profile Lock Pin Header ●F Type Lock Pin Header

Lock G Lock F
Part Number : HIF3BAG-**PA-2.54DSA(63) Part Number : HIF3BAG-**PA-2.54DSA(63)

27.3
21.5
Nov.1.2021 Copyright 2021 HIROSE ELECTRIC CO., LTD. All Rights Reserved.

●Low profile type, and used for lock ejection. ●Locking range more reduced than conventional lock type.
Connector height is reduced. Even if connectors are aligned laterally, the mounting
Since no connector clamp is needed on the cable side, space is reduced.
this is used without turning back on the cable side. Take Note : The clamp must be replaced for HIF3A socket type
care about this point. 60 contacts only. Take care about this point.

B24
HIF3B Series●Ribbon Cable connector Compliant with MIL Standard

■Socket for Crimping


Nov.1.2021 Copyright 2021 HIROSE ELECTRIC CO., LTD. All Rights Reserved.

Unit : mm
Part No. HRS No. No. of Contacts A B Polarizing Guide RoHS
HIF3BA-10D-2.54C(63) 610-1041-0 63 10 17.25 10.16
HIF3BA-14D-2.54C(63) 610-1051-3 63 14 22.35 15.24
HIF3BA-16D-2.54C(63) 610-1042-2 63 16 24.8 17.78
HIF3BA-20D-2.54C(63) 610-1043-5 63 20 29.95 22.86
One at center
HIF3BA-26D-2.54C(63) 610-1044-8 63 26 37.55 30.48
HIF3BA-30D-2.54C(63) 610-1045-0 63 30 42.63 35.56
HIF3BA-34D-2.54C(63) 610-1046-3 63 34 47.75 40.64
YES
HIF3BA-40D-2.54C(63) 610-1047-6 63 40 55.35 48.26
HIF3BA-50D-2.54C(63) 610-1048-9 63 One right and left side, resp.
50 68.04 60.96
HIF3BB-50D-2.54C(63) 610-1061-7 63 One at center
HIF3BA-60D-2.54C(63) 610-1049-1 63 One right and left side, resp.
60 80.77 73.66
HIF3BB-60D-2.54C(63) 610-1062-0 63 One at center
HIF3BA-64D-2.54C(63) 610-1064-5 63 One right and left side, resp.
64 85.85 78.74
HIF3BB-64D-2.54C(63) 610-1063-2 63 One at center
Note : Some variations may differ from those in above figures.

B25
HIF3B Series●Ribbon Cable connector Compliant with MIL Standard

■Cover Case for Crimping socket


Nov.1.2021 Copyright 2021 HIROSE ELECTRIC CO., LTD. All Rights Reserved.

Unit : mm
Part No. HRS No. No. of Contacts A B C D E RoHS
HIF3-20CV(72) 562-0201-0 72 20 24.5 18.0 12.0 30.5 29.95
HIF3-26CV(72) 562-0202-2 72 26 30.2 20.0 14.0 32.0 37.55
HIF3-30CV(72) 562-0203-5 72 30 32.2 22.0 16.0 33.0 42.63
HIF3-34CV(72) 562-0204-8 72 34 34.2 24.0 18.0 33.5 47.75 YES
HIF3-40CV(72) 562-0205-0 72 40 36.2 26.0 20.0 35.5 55.35
HIF3-50CV(72) 562-0206-3 72 50 39.2 29.0 23.0 38.0 68.04
HIF3-60CV(72) 562-0207-6 72 60 42.2 32.0 26.0 40.5 80.77
Note 1 : The type F lock pin header cannot be used for a mating member.
Note 2 : Note that the product cannot be used with AWG #20.
Applicable jacket diameters are as described below.

20 contacts : 1.7mm diameter MAX


26 to 40 contacts : 1.6mm diameter MAX
50 to 60 contacts : 1.4mm diameter MAX

B26
HIF3B Series●Ribbon Cable connector Compliant with MIL Standard

BContact (Crimping Contact for Socket)


Nov.1.2021 Copyright 2021 HIROSE ELECTRIC CO., LTD. All Rights Reserved.

B27
HIF3B Series●Ribbon Cable connector Compliant with MIL Standard

BTools
●Crimping Tool

Part No. HRS No.


HIF3-T2226HC 550-0063-8

Manual Crimping Tool HIF3-T2226HC


Nov.1.2021 Copyright 2021 HIROSE ELECTRIC CO., LTD. All Rights Reserved.

●Automatic Crimping Tool (Type : CM-105C)

Part No. HRS No.


CM-105C 901-0001-0

●Contact Extraction Tools How to use the extraction tool

(1) How to extract contacts (2) How to adjust the lance (raise)

As shown in Figure 1, where the In order to re-insert the contact


extraction tool is inserted in the lance removed from the insulated case,
fixed slot on the insulated case, slightly raise the contact lance area using the
pull the cable, and the contact can be tool A, and re-insert the contact, as
removed. shown in Figure 2.

Part No. HRS No.


HIF1-PO 550-0049-7
Figure 1

B28
HIF3B Series●Ribbon Cable connector Compliant with MIL Standard

BSocket Side (Crimping) Assembling Procedures


(1) As shown in Figure 1, peel the applicable cable (AWG#20 to #26) jacket, and connect it using crimping jig HIF3-TA2022HC,
HIF3-TA2226HC, or HIF3-TA2426HC. In this case, insert the cable so as to hit the contact cable stripper position as shown
Figure 2.
(2) After connection as shown Figure 2, check the contact direction, and insert the contact as shown Figures 3 and 4. Slightly pull
the cable, and check whether the contact lance position is firmly fixed to the insulation case, as shown in the area (A).

Note1 : For handling procedures for special crimping tools, refer to the "Handling Instruction Manual".
Note2 : Wire strip length : Refer to crimp condition sheet.