0% found this document useful (0 votes)
185 views4 pages

FGW2 Weichai Genset WP2.3 Series 60HZ 15 50kwe LTP

The document summarizes specifications for the Weichai Power WPG15-WPG50 land-based generator set series. Key details include: - Models range from 19-63kVA and are powered by Weichai WP2.3 series engines from 14-44kWe. - Engines are 4-cylinder inline diesel units cooled by liquid and featuring electronic governing. - Alternators are brushless, self-excited units ranging from XN164D to XN184J frames with IP23 protection. - Dimensions and weights are provided for open and enclosed versions. - Warranties of 1 year prime and 2 years standby are offered.

Uploaded by

Mahmoud Koko
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
185 views4 pages

FGW2 Weichai Genset WP2.3 Series 60HZ 15 50kwe LTP

The document summarizes specifications for the Weichai Power WPG15-WPG50 land-based generator set series. Key details include: - Models range from 19-63kVA and are powered by Weichai WP2.3 series engines from 14-44kWe. - Engines are 4-cylinder inline diesel units cooled by liquid and featuring electronic governing. - Alternators are brushless, self-excited units ranging from XN164D to XN184J frames with IP23 protection. - Dimensions and weights are provided for open and enclosed versions. - Warranties of 1 year prime and 2 years standby are offered.

Uploaded by

Mahmoud Koko
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Land Based Genset- WP2.

3 Series
WPG15 / WPG25 / WPG35 / WPG40 / WPG50
19-63kVA,14-44kWe Prime

www.dinatek.ec

V.21A
Engine Alternator
◼ Weichai WP2.3 series, 4 cylinder, in-line 4 stroke, ◼ Brushless type, Screen protected, Revolving
radiator cooled engine field, Self excited alternator conforming to IS/IEC
◼ Well-designed air handling system with 60034-1
— Dry type, Replaceable paper element air cleaner ◼ Best in class efficiency
with restriction indicator ◼ Steel casing
— Air to air after cooling ◼ Compact design with sealed bearings for longer
— Optimized turbocharger for increased altitude life and lesser maintenance
capabilities ◼ IP23 standard protection level
— High efficiency, large heat area intercooler, reduce ◼ Impregnation on all wound components for
the air temperature after the intercooler better
◼ Fuel system with A1 class electronic governing mechanical strength
◼ Standard integral set-mounted radiator system,
designed and tested for 50°C ambient temperature
◼ First fill of lube oil and coolant
Control Module Specifications
◼ Electrical starter motor with soft start engagement The DSE6020 is an Auto Mains Failure Control
feature Module
◼ Intelligent fuel injection technology to start fast ◼ Back-lit LCD display
guarantee ◼ 3 Phase generator and 3 Phase Mains
◼ Battery charging alternator monitoring
◼ 1 x 12 V DC batteries ◼ Monitoring speed, frequency, voltage, current,
oil pressure, coolant temperature and fuel level
◼ Display warning, shutdown and engine status
information
◼ Hours counter provides accurate information for
monitoring and maintenance
Technical Data
Generator Set Specification
Model WPG15*16 WPG25*16 WPG35*16 WPG40*16 WPG50*16
Standby Rating kVA/kWe 19/15 31/25 44/35 50/40 63/50
Prime Rating kVA/kWe 18/14 28/22 40/32 45/36 55/44
Voltage V 440/254 440/254 440/254 440/254 440/254
Frequency Hz 60 60 60 60 60
Power Factor 1 or 0.8(lagging) 1 or 0.8(lagging) 0.8(lagging) 0.8(lagging) 0.8(lagging)
No. of Phases 1 or 3 1 or 3 3 3 3
Engine specification
Make Weichai / Baudouin
Model WP2.3D25E201 WP2.3D30E201 WP2.3D41E201 WP2.3D47E201 WP2.3D63E211
Rated Speed 1800 1800 1800 1800 1800
Prime Power 23 27 37 43 58
Cooling Liquid cooled Liquid cooled Liquid cooled Liquid cooled Liquid cooled
Governor Electronic Electronic Electronic Electronic Electronic
Aspiration NA NA T T TA
No. of cylinders 4,in-line 4,in-line 4,in-line 4,in-line 4,in-line
Bore (mm) x Stroke (mm) 89x92 89x92 89x92 89x92 89x92
Displacement (L) 2.3 2.3 2.3 2.3 2.3
Fuel consumption@75%(L/h) 3.5 5.5 8 9 11
Fuel consump. @100%(L/h) 4.6 7.3 10.6 12 14.6
Starting system 12VDC 12VDC 12VDC 12VDC 12VDC
Electrical Electrical Electrical Electrical Electrical
Total lub. system capacity (L) 9.5 9.5 9.5 9.5 9.5
Total coolant capacity (L) 8.2 8.2 9.4 9.4 15
Cooling fan airflow(m³/min) 55 55 55 55 120
Exhaust Temperature (°C) ≤700 ≤700 ≤650 ≤650 ≤650
Rec. Air flow @ PRP (m³/min) 58 58 58 58 127
Exhaust back pressure (mBar) ≤80 ≤80 ≤80 ≤80 ≤80
Radiator design temp.(℃) 50 50 50 50 50
Alternator specification
Make Weichai / Baudouin
Alternator Frame XN164D XN184E XN184H XN184H XN184J
Exciter Type Self-excitation Self-excitation Self-excitation Self-excitation Self-excitation
Enclosure IP23/IP21 IP23/IP21 IP23/IP21 IP23/IP21 IP23/IP21
Voltage regulation ≤±1% ≤±1% ≤±1% ≤±1% ≤±1%
Class of Insulation H H H H H
Winding Pitch 2/3 2/3 2/3 2/3 2/3
Rotor Single bearing Single bearing Single bearing Single bearing Single bearing
Remarks
Prime Rating: These ratings are applicable for supplying continuous electrical power (at variable load) in
the lieu of commercially purchased power. There is no limitation to the annual hours of operation and this
model can supply 10% overload power for 1 hour in 12 hours.
Standby Rating: These ratings are applicable for supplying continuous electrical power (at variable load) in
the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is
peak continuous tested (as defined in ISO 8528‐3).

Standard Reference Conditions


Note: Standard reference conditions 25℃(77℉)Air Inlet Temp, 100m(328 ft) A.S.L. 30% relative humidity.
Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869:
1998, Class A2.

Genset Dimensions (F: Open Series with fuel base tank / L: Silent Canopy Series)
Prime Rating Length Width Wet Weight Standard Fuel tank
Genset Mode Height C(mm)
(kVA) A(mm) B(mm) (kg) Capacity (L)
WPG15F16 18 2050 965 1470 750 55
WPG25F16 28 1400 780 1150 600 55
WPG35F16 40 1400 780 1150 600 55
WPG40F16 45 1470 780 1130 620 55
WPG50F16 55 1470 780 1130 650 55
WPG15L16 18 1900 720 1095 900 48
WPG25L16 28 1900 720 1095 900 48
WPG35L16 40 1900 720 1095 900 48
WPG40L16 45 1900 720 1095 900 48
WPG50L16 55 2200 880 1095 920 48

Open genset Enclosed genset

Sales Promises
Each and every unit is strictly factory tested.
Warranty time: Prime duty 1 year or 1000Hours. Stand-by duty 2 years or 1000 hours.
Service and parts are available from Weichai Power or distributors in your location.

Distributed By: Manufacturer: Weichai Heavy Machinery Co., Ltd


Address: 197 A, Fuzhou East Street, High-Tech
Development Zone, Weifang, China
www.dinatek.ec www.weichaihm.com