B11 Manual V1 1
B11 Manual V1 1
Dual Networks
Alarm System
Printed in China
C 2014 Chuango Security. All Rights Reserved. OI: B11-UM-EN-V1.1 User Manual
Table of Contents
Control Panel Layout ------------------------------------------------------------ 03~04 Answering Alarm Phone Call to Start Remote Control ----------------------------- 41
Preparation before Use --------------------------------------------------------- 05~06 Remote Control by Calling Fixed Phone Number----------------------------------- 42
01 02
Control Panel Layout Rear Side
MIC Tamper Switch Speaker
Front Side
GSM Network LED
Esc
Up/Down
Backup Batteries
Enter
03 04
Preparation before Use Insert a SIM Card
This step can be ignored if GSM function is not applied.
Power on Insert a SIM card into the card slot according to the mark and lock it.
1. Plug the output connector of AC adapter into the adapter Jack of control panel.
2. Plug the AC adapter into a wall outlet.
Note: A GSM SIM card with normal functions (calling, answering, SMS and caller display) is
required. If use App to control the alarm system through GPRS network, it is recommended
Connect PSTN Land Line to activate a GPRS plan to save expense.
B11 is a PSTN & GSM dual networks alarm system, If there is an alarm, it will auto dial Insert the SIM card only after the control panel is switched off. Then, switch on the control
panel so as to search signals.
pre-stored phone numbers though landline, or dial through GSM network when
If no SIM card is inserted, the control panel can only send alarm notification by calls through
landline is unavailable.
land line and users cannot remote control the control panel through App. However, other
functions are not affected.
1. Connect the smaller connector of provided telephone cable to the 2
PSTN land line interface at the back side of the panel.
2. Connect the other end of the telephone cable to the signal output
provided by PSTN land line operator.
05 06
Disarm
Control Panel Operation
Input user code (Default: 1234) or
admin code (Default: 123456) first,
Alarm Control then press the [Disarm ] button,
Arm (Away Arm) the system enters disarm state when
Press the [Arm ] button on the one beep is heard and the disarm
control panel, the system enters Arm LED Indicator lights on.
state when one beep is heard and the
arm LED Indicator lights on.
07 08
Access Control System Voice Memo
The control panel has a RFID reader for Press the [Record Voice Memo ] button for 3 seconds to record 10 seconds voice
unlocking the electronic door lock by disarming message. The Play Voice Memo circle will be flashing to remind you. Users can touch
the system. Just place the RFID tag close to the the center of circle to listen to the voice memo. The LED indicator blacks out when the
RFID reader, the blue LED indicator flashes voice memo has been played. Replay by touching it again.The latest voice memo will
once. cover the former message.
The system is disarmed and the electronic door
lock is opened (If connected).
1 2
The control panel has a built-in communication module. If the PSTN land line is
connected or SIM card is connected properly, and the credit is enough, you can use
the panel to make calls.
(System will auto dial through land line first, or dial through GSM network when land
line is unavailable ).
When the control panel is in disarm or home mode state, press [Call ] button, input
Function Setting
the phone number and press [Call ] button again, the line will get through.
If you input wrong numbers, press [Esc] button and input again. Press [Esc] button to
cancel dialing or press [Call ] button to end a conversation.
Note: If control panel is connected with extension line, 0# or 9# need to be added in front of
the phone number when making phone calls. if the land line is unavailable, system will switch
to GSM network, user can make phone calls by inputting phone number directly without 0# or Input the admin code (Default: 123456), and then press [Enter] to enter setting menu.
9#. Up Enter Confirm
Down Esc Back to last step
09 10
Arm
Security Alarm Function
Press the [Arm ] button, the system enters
arm state when one beep is heard and the
arm LED on the control panel is on.
Test Accessories
Our accessories can work only with our control panels, can not work with other brands.
Note: If Exit Delay is activated, all zones except
the 24-hour zone will enter arm state after the
Remote Control
set delay time.
RC-80 remote control is dainty and delicate, easy to carry. It can be attached to your
key ring, or just put into your pockets or purses.When you are about to exit or entry
the house, you can use it to arm or disarm the system. In case of emergency, just press
Disarm
the [SOS] button, the alarm will be activated immediately.
Press the [Disarm ] button on the remote
control, the system enters disarm state when
Appearance
two beeps are heard and the disarm LED on
the control panel is on.
LED Status Indicator When alarm is activated, the siren will hoot.
Arm Press the [Disarm ] button, the system is
disarmed . But the LED indicator of triggered
Disarm
Stay zone keeps flashing for further checking.
Press [Disarm ] button again, the alarming
Panic
zone indicator goes out.
11 12
Mute Operation Door/Window Contact
When arm or disarm the system, the siren will The door/window contact can be installed on doors, windows, and any other objects that
beep accordingly. can open and close. The sensor transmits signals to the control panel when a magnet
If siren beep is not needed, please operate as mounted near the sensor is moved away. External input for wired accessory is available at
follows: the N/C interface. The tamper protection ensures that sabotage attempts to move the
Press [Stay ] button on the remote control contact will result in an alarm activation.
Note: If wireless strobe sirens are used, they will not sound either.
LED Indication
LED Meaning
PCB Layout
AA 1.5V LR6
Tamper switch
13 14
Test Pet-Immune PIR Motion Detector
1. Press the back cover and slide down to remove the back cover. The detector adopts digital dual-core fuzzy logic control processing technology and
2. Remove the insulating strip. The contact works immediately. intelligent analysis algorithm, effective resolution of interfering signal and human
3. Press the [Arm ] button on the remote control. The system switches to the arm movement signal, preventing false alarm. It features automatic temperature
status. Separate the transmitter and magnet. The LED is on and the panel alarms. It compensation and resistance to flow technology, adapting to environmental and
indicates that the sensor works properly. temperature change. It can detect human movement within the 8-meter cone space,
suitable for halls, hallways, etc. The detector features pet immunity for small animals
Note: There are triangle marks on the side of the transmitter and magnet. Make sure the up to 25kgs.
triangle marks face each other and within the range of 1 cm.
Appearance
LED Indication
Blinks continuously: Under self-testing state.
Blinks once: Intruder is detected.
Blinks twice: 3 minutes testing is finished, enters power saving mode.
Blinks once per 3 seconds: Low battery indication, LCD shows: Sensor 1-50(Sensor
Name) low battery, please change the batteries immediately.
PCB Layout
AA 1.5V LR6
AA 1.5V LR6
place spacers under the transmitter
Note: If the detector is disassembled,
and magnet. Do not apply the contact
system will sound immediately,and
to a rolling shutter. Purchase dedicated
LCD shows "Sensor 1-50(Sensor
contacts for rolling shutters when
Name) Sensor Tamper".
necessary.
Infrared sensor Zone setting
15 16
Working Mode Test
No human movement
Note: After the detector is in the sleeping state, within 3 minutes
ensure no human movement within 3 minutes;
otherwise, the detector remains sleeping. Switch from
sleep to arm.
In the sleeping state, it is recommended that
you leave the room after arming the system.
Ensure no human movement in 3 minutes.
Then, go into the room, the system alarms
immediately.
Note: The testing mode sustains for 3 minutes. Then, the LED blinks twice, indicating the
detector is in the power saving mode.
17 18
Installation 3. Testing
Press the test button on the back of the detector, walk in the detection scope and watch
1. Choose installation place
the LED indication to make sure the detector is working.
It is recommended to mount it at the height of 2m from the ground. (For installation
notices, please see page 21-22)
2m
4. Adjust the bracket angle
Adjust the bracket angle to achieve the best detection effect.
Ground
Note: If pet-immune function is used, please do not adjust the angle up or down, but keep it
parallel with the wall.
Detection Scope
0m 2m 4m 6m 8m
2m
Side view
19 20
Installation Notices 3. Avoid facing to glass windows or doors
Pay attention to the following during installation: Strong light interferes with detection
sensitivity. In addition, complicated
1. Mount the detector to a location close to the entry or exit
situations, such as traffic flow, stream of
The detector aims at preventing intrusion. Detecting human movement at the entry or
people, also should be avoided.
exit is critical for security.
21 22
LCD Display Contents SMS
Disarm
Arm or Disarm
SMS
System Status Display content Home Arm
Alarm
Line Disconnect
SOS
AC Power Failure
Alarm
Host Low Battery Linecut
GPRS Connected Alarm
Stand-by Sensor 1-50(Sensor Name) Panel Tamper
Low Battery Alarm
Alarm
NO SIM CARD Wired Sensor
GPRS Connecting Sensor1-50(SensorName)
GPRS Disconnected SensorTamper
Remote Arm
Remote Disarm
23 24
LCD Display Menu Date
Date And
Date Format
Time
When LCD is activated, input the admin code (Default: 123456), and then press [Enter]
Time
to enter setting menu.
Entry Delay <000S>
Entry Exit
Main Menu Sub Menu 1 Sub Menu 2 Sub Menu 3
Delay
Exit Delay <000S>
Alarm Number1-6
Add Phone
Number Backlight
CMS Number1-2 Time
Phone
<20S>
Numbers
Alarm Number1-6
Del Phone Auto Arm Time
Number <00:00:00>
CMS Number1-2 Auto Arm/
Disarm Auto Disarm Time
Add
Remote & System <00:00:00>
ALL Settings
Keypad Delete
Remote (01-10)
Edit Welcome
Add
ALL
RFID Tag Delete Linecut On
RFID (01-50)
Alarm Off
Edit Name RFID (01-50)
Add Keypad On
ALL Tones Off
Delete
Accessories Sensor (01-50)
Input 6 Digits
Admin Code
<Default Code 123456>
Sensor (01-50)
Wireless
Edit Sensor Type Access Input 4 Digits
Sensors User Code
(Normal Sensor, 24 Hour Code <Default Code 1234>
Edit
Sensor, Delay Sensor,
Input 4 Digits
Home Sensor) Duress Code
<Default Code 1111>
Edit Sensor Name
Test Mode
25 26
Ringing Times
Settings
Alarm Message Record When LCD is activated, input the admin code (Default: 123456), and then press [Enter]
to enter setting menu.
Siren On/Off <On/Off>
Wired Siren
Important: The default language of this alarm system is English, you can change in the
Arm/Disarm Tone <On/Off>
[Language] menu of [System Setting].
Reset
Delete Alarm Phone Number
History
1 Log on the menu, choose “Phone Numbers”, press [Enter].
2
Press [ ] or [ ] , choose “Delete Phone Number”, press [Enter].
3
Press [ ] or [ ] , choose “Alarm Number1~6”, press [Enter].
4
Delete the alarm phone numbers in order, press [Enter] again.
Note: If user wants to set CMS center phone number, please refer to “Connect to CMS Center”.
27 28
2. Add/Delete/Edit Accessories Delete
The control panel only receives signal from accessories after they are connected to the If user wants to delete the added RFID cards or tags, please choose “Delete” in step 3
control panel. as above and press [Enter]. Then choose to delete all or specific RFID cards or tags,
press [Enter] again.
31 32
Exit Delay Timed Disarm
Exit delay is set to leave time for user to exit before the system is armed. 1
Log on the menu, press [ ] or [ ] , choose “System Settings”, press [Enter] for
1 Log on the menu, press [ ] or [ ] , choose “System Settings”, press [Enter]. confirmation.
2 Press [ ] or [ ] , choose “Entry Exit Delay”, press [Enter]. 2 Press [ ] or [ ] , choose “Auto Arm/Disarm”, press [Enter].
3 Press [ ] or [ ] , choose “Exit Delay”, press [Enter]. 3 Press [ ] or [ ] , choose “Auto Disarm Time”, press [Enter].
4 Input time for exit delay; press [Enter] for confirmation. 4 Input exact time for disarming; press [Enter].
Exit delay time is calculated on seconds; default is 0 second (off ); setup range is 0-999
seconds. Edit Greeting Message
When greeting message is set; turn on the alarm system or activate the touch keyboard;
Note: Once delay time is set, when arm the system, one beep will be heard every second to the greeting message will be shown on LCD display.
remind the user to leave , the reminding rhythm will speed up in the last 15 seconds.
1 Log on the menu, press [ ] or [ ] , choose “System Settings”, press [Enter].
2 Press [ ] or [ ] , choose “Edit Welcome”, press [Enter] to define the greeting message.
Backlight Time [ ] means to delete, [ ] means to space, [ ] means to move backward, [ ] means
to move forward.
User can set standby time of the backlight on the blue LCD display accordingly.
1 Log on the menu, press [ ] or [ ] , choose “System Settings”, press [Enter].
2 Press [ ] or [ ] , choose “Backlight Time”, press [Enter]. Line Cut Alarm
3 Input time for backlight time; press [Enter]. When linecut alarm function is on, the control panel will alarm once the PSTN land line
Backlight time is calculated on seconds; default is 20 seconds; setup range is 01-99 is cut or pulled out even if the built-in siren was set to mute..
seconds.
Turn On/Off Linecut Alarm
1 Log on the menu, press [ ] or [ ] , choose “System Settings”, press [Enter].
Timed Arm / Disarm
2 Press [ ] or [ ] , choose “Linecut Alarm”, press [Enter].
User can set timed arm and disarm according to daily schedule to avoid repeated 3 Press [ ] or [ ] , choose “On” or “Off”, press [Enter].
operation.
“On” is to turn on the linecut alarm; “Off” is to turn off the linecut alarm.
Timed Arm Default setting is “On”, the linecut alarm is on.
1 Log on the menu, press [ ] or [ ] , choose “System Settings”, press [Enter].
2 Press [ ] or [ ] , choose “Auto Arm/Disarm”, press [Enter]. Keypad Tone
3 Press [ ] or [ ] , choose “Auto Arm Time”, press [Enter]. User can turn on/off keypad tone accordingly.
4
Input exact time for arming; press [Enter].
Turn On/Off Keypad Tone
1 Log on the menu, press [ ] or [ ] , choose “System Settings”, press [Enter].
2 Press [ ] or [ ] , choose “Keypad Tone”, press [Enter].
3 Press [ ] or [ ] , choose “On” or “Off”, press [Enter].
“On” is to turn on the keypad tone; “Off” is to turn off the keypad tone. Default setting
is “On”, keypad tone is on.
33 34
Access Code Ringing Times for Remote Phone Control
All the alarm panels are with default user code, admin code and duress code. Please After the set ringing times, user can make system settings from remote calling, such as
change all codes before using and keep your codes secret. arming/disarming the system.
1 Log on the menu, press [ ] or [ ] , choose “System Settings”, press [Enter].
Admin Code
2 Press [ ] or [ ] , choose “Ringing Times”, press [Enter].
With admin code, user can arm and disarm, make system settings as well as reset codes 3 Input 5~9 for ringing times, press [Enter].
etc. Default setting is 5 times.
1 Log on the menu, press [ ] or [ ] , choose “System Settings”, press [Enter].
2 Press [ ] or [ ] , choose “Access Code”, press [Enter].
Alarm Message
3 Press [ ] or [ ] , choose “Admin Code”, press [Enter].
User can leave a 10-second voice message when control panel makes call to user's
4 LCD display will show “Input 6 Digits”, then input 6 digits for code, press [Enter].
stored phone number, voice recording will be repeatedly played to notify the intrusion.
(Default Admin Code: 123456)
5 Input the new admin code, press [Enter]. Record Alarm Message
1 Log on the menu, press [ ] or [ ] , choose “System Settings”, press[Enter].
User Code
2 Press [ ] or [ ] , choose “Alarm Message”, press [Enter].
With user code, user can set arm, home mode and disarm the alarm system.
3 Press [ ] or [ ] , choose “Record”, press [Enter].
1 Log on the menu, press [ ] or [ ] , choose “System Settings”, press [Enter].
4 LCD display will show “Record 10s Voice” to remind you of the 10 seconds voice
2 Press [ ] or [ ] , choose “Access Code”, press [Enter].
recording, press [Enter].
3 Press [ ] or [ ] , choose “User Code”, press [Enter].
5 Start voice recording for 10s until the system stops automatically, or press [Enter] to
4 LCD display will show “Input 4 Digits”, then input 4 digits for code, press [Enter].
stop recording.
(Default User Code: 1234)
5 Input the new user code, press [Enter].
Siren Setup
Duress Code Users can turn on/off wired siren, wireless siren, built-in siren as arm/disarm beep and
In case of emergency, when user is violently requested to disarm the system, it's set siren ringing time.
recommended to use the duress code to disarm the alarm system. The panel will
Wired Siren
silently dial alarm telephone numbers stored.
Wired siren is connected to the control panel by wire.
1
Log on the menu, press [ ] or [ ] , choose “System Settings”, press [Enter].
2
Press [ ] or [ ] , choose “Access Code”, press [Enter]. Turn On/Off Wired Siren
3 Press [ ] or [ ] , choose “Duress Code”, press [Enter]. 1 Log on the menu, press [ ] or [ ] , choose “System Settings”, press [Enter].
4 LCD display will show “Input 4 Digits”, then input 4 digits for code, press [Enter]. 2 Press [ ] or [ ] , choose “Siren Setup”, press [Enter].
(Default Duress Code: 1111) 3 Press [ ] or [ ] , choose “Wired Siren”, press [Enter].
5 Input the new duress code, press [Enter]. 4 Press [ ] or [ ] , choose “Siren On/Off”, press [Enter].
5 Press [ ] or [ ] , choose “On” or “Off”, press [Enter].
“On” is to turn on the wired siren; “Off” is to turn off the wired siren.
Default setting is “On”; the wired siren is on.
35 36
Turn On/Off Arm/Disarm Beep for Wired Siren Built-in Siren
1 Log on the menu, press [ ] or [ ] , choose “System Settings”, press [Enter]. Built-in siren is the siren inside the control panel.
2 Press [ ] or [ ] , choose “Siren Setup”, press [Enter].
Turn On/Off Built-in Siren
3 Press [ ] or [ ] , choose “Wired Siren”, press [Enter].
1 Log on the menu, press [ ] or [ ] , choose “System Settings”, press [Enter].
4 Press [ ] or [ ] , choose “Arm/Disarm Beep”, press [Enter].
2 Press [ ] or [ ] , choose “Siren Setup”, press [Enter].
5 Press [ ] or [ ] , choose “On” or “Off”, press [Enter]
3 Press [ ] or [ ] , choose “Built-in Siren”, press [Enter].
“On” is to turn on arm/disarm beep for wired siren; “Off” is to turn off arm/disarm beep
4 Press [ ] or [ ] , choose Siren Siren On/Off, press [Enter].
for wired siren.
5 Press [ ] or [ ] , choose Off/Low/High, press [Enter]
Default setting is “On”; arm/disarm beep is on.
Choose "Low" or "High" to adjust the volume; "Off" is to turn off the built-in siren.
The default setting is "Low".
Wireless Siren
Wireless siren is connected to control panel through wireless connection. Turn On/Off Arm/Disarm Beep for Built-in Siren
1 Log on the menu, press [ ] or [ ] , choose “System Settings”, press [Enter].
Turn On/Off Wireless Siren
2 Press [ ] or [ ] , choose “Siren Setup”, press [Enter].
1 Log on the menu, press [ ] or [ ] , choose “System Settings”, press [Enter].
3 Press [ ] or [ ] , choose “Built-in Siren”, press [Enter].
2 Press [ ] or [ ] , choose “Siren Setup”, press [Enter].
4 Press [ ] or [ ] , choose “Arm/Disarm Beep”, press [Enter].
3 Press [ ] or [ ] , choose “Wireless Siren”, press [Enter].
5 Press [ ] or [ ] , choose “On” or “Off”, press [Enter]
4 Press [ ] or [ ] , choose “Siren On/Off”, press [Enter].
“On” is to turn on arm/disarm beep for built-in siren; “Off” is to turn off arm/disarm beep
5 Press [ ] or [ ] , choose “On” or “Off”, press [Enter]
for built-in siren. Default setting is “On”; arm/disarm beep is on.
“On” is to turn on the wireless siren; “Off” is to turn off the wireless siren.
Default setting is “On”; the wireless siren is on.
Set Ringing Time for All Sirens
Turn On/Off Arm/Disarm Beep for Wireless Siren 1 Log on the menu, press [ ] or [ ] , choose “System Settings”, press [Enter].
1 Log on the menu, press [ ] or [ ] , choose “System Settings”, press [Enter]. 2 Press [ ] or [ ] , choose “Siren Setup”, press [Enter].
2 Press [ ] or [ ] , choose “Siren Setup”, press [Enter]. 3 Press [ ] or [ ] , choose “Siren Alert Time”, press [Enter].
3 Press [ ] or [ ] , choose “Wireless Siren”, press [Enter]. 4 Input the ringing time, press [Enter].
4 Press [ ] or [ ] , choose “Arm/Disarm Beep”, press [Enter]. Siren ringing time is calculated as seconds, default setting is 300 seconds. If 0 second
5 Press [ ] or [ ] , choose “On” or “Off”, press [Enter] is set, siren will not ring.
“On” is to turn on arm/disarm beep for wireless siren; “Off” is to turn off arm/disarm
beep for wireless siren.
Default setting is “On”; arm/disarm beep is on.
37 38
User ID for CMS Connect to CMS
Please see details at Page 40: Connect to CMS
Please ignore this step if users don't need to connect to CMS center.
Upload Arm Report
When connected to CMS center, control panel will upload contact ID to CMS center
Please see details at Page 41: Connect to CMS
automatically once intrusion is detected.
Note: If user wants to check or edit the pre-stored phone no., enter “CMS Number1~2” to check or
If user forget the admin code and cannot setup the system, please contact local edit.
distributors.
39 40
Upload Arm/ Disarm Report to CMS Center Remote Control by Calling Telephone Number
When this function is enabled, all arm/disarm reports will be uploaded automatically to 1 Call the telephone number of alarm system. After getting through, input user code or
CMS center, so that CMS center can know the status of the alarm system. admin code, and press [#] to confirm.
1 After the User ID is set, press [ ] or [ ] to choose “Arm Upload” or “Disarm Upload”, 2 Users can choose the related instruction to make remote control operation. (See
press [Enter]. instruction table below). If there is no operation within 30 seconds, the system will
2 Press [ ] or [ ] , Choose “On”, press [Enter]. hang up.
3 When choosing “Off” during setup 2 , press [Enter], arm/ disarm report will not be
uploaded to CMS center. Remote Phone Control Instruction Table
Phone
Function Explanation
Contact ID Reports Buttons
Press [ ] Arm the system Arm succeed
Event Code Event Event Code Event
3401 Arm 1137 Control panel tamper alarm Press [ ] Disarm the system Disarm succeed
1401 Disarm 1144 Sensor tamper alarm Press [ ] Monitor on site Press [*] to prolong monitor time
1409 Disarm by RFID tag 1140 Normal zone alarm Press [ ] Turn on siren Deter the intruders
1132 PIR detector alarm 1133 24H zone alarm Siren stops ringing
Press [ ] Turn off siren
1131 Door contact alarm 1384 Sensor low battery
Press [ ] Turn on relay
1100 Emergency call 1302 Control panel low battery Available when relay is used
Press [ ] Turn off relay
1120 Duress alarm 1301 Control panel AC failure
3456 Home mode (part arm) Press [ ] To exit Remote Phone Control Or hang up the phone
41 42
SMS Operation Home Mode (Part Arm)
In home mode, detectors setting to home mode zone are in disarmed status; the other
detectors are still in armed status. That is, you can move freely in the home mode zone;
You can control the system by sending SMS commands to the SIM card No. SMS is
however, the rest areas are still being protected.
charged according to telecom operator.
Any phone number can send SMS to control the system by default, after you store
alarm phone numbers to the control panel, system accepts only the commands from 2
these numbers.
This is to disarm the system. In disarmed status, the detectors (except those accessories
in the 24-hour zone) will not trigger an alarm when detecting intrusion.
Monitor
This is to monitor the site remotely by call-back from the control panel.
0 After the control panel receives the SMS, it calls your phone number. Then, you can
answer the call and monitor (listen in) the site.
System disarmed.
3
Arm (Away Arm)
This is to arm the system. In armed status, the system will trigger an alarm when Recording Voice Memo
detecting intrusion. This is to record a 10-second voice memo by call-back from the control panel.
After the control panel receives the SMS, it calls your phone number. Answer the phone
and then you can start to record a 10-second voice memo. The control panel will hang
1 up phone after 10 seconds.
System armed. 4
43 44
App Operation Control through SMS
Any phone number can operate the system through APP by default, after you stored
alarm phone numbers on the control panel, system accepts only the commands from
This system can be controlled through SMS or GPRS interface on APP. If user choose these numbers.
SMS: for iPhone, the interface of sending SMS will display. For Android smart phones,
SMS will be directly sent to the number of the control panel without interface redirection. 1. Add accounts
Adding accounts enables you to bind the alarm systems to your smart phone. You can
Download and Install APP add more accounts to control several B11 alarm systems on one phone.
Search keywords “B11 alarm” in Apple Store or Google Play, downloads it for free.
① Enter [Accounts]
Tap B11 APP, choose [SMS], and then enters account management interface.
② Add account
Tap [ + ], input the SIM card number of the control panel on [Mobile Number], and then
tap [OK].
B11
45 46
2. Operations on main menu Control through GPRS Data
Tap the SIM card number of the control panel to enter the main menu, user can
APN Setting
perform disarm, arm, home arm, monitor and leave voice memo.
Some SIM cards need to set APN to open GPRS function. If the GPRS function of the
SIM card in B11 doesn’t work out. Do as follow:
Send 'APN' to the SIM card in the control panel; you’ll get a message back. Forward
and fill in related APN, username and password,, then send it back. You’ll get a
message 'OK' from the SIM card in the control panel to notify you that the setting is
successful. Turn off the panel and restart, then you can operate the APP via GPRS
freely.
For instance, for SIM card from Vodafone in Netherlands, there is no username and
password, leave it as it is. A message replied ’OK’, means the setup is successful.
APN:
User name:
Password:
APN:live.vodafone.com
User name:
Password:
Android phone: Tap [EDIT], press and hold the account number until the dialog box
appears, tap [OK] to confirm deletion.
OK
Note: The APN setting varies in different countries. Consult the local operator on how to set the
APN correctly.
47 48
1. Register 2. Operations on main menu
Registering account enables you to bind the alarm systems to your smart phone. Login to enter the main menu, user can perform disarm, arm, home arm, monitor and
leave voice memo.
① Enter login interface
Tap B11 APP, choose [GPRS], and then the login interface appears.
13211110000
******
3. Delete accounts
Press [ ] on the main menu after login, tap [OK] on the dialog box to confirm
② Register an account
deletion.
Tap [Register], input your mobile number , password, device ID, random code (SN code
on the back side of the panel), and then tap [OK].
Note: When register, please input user’s mobile number instead of the SIM card number of the
control panel. The device ID, random code are shown on the back side of the control panel,
please keep it properly for safety.
49 50
4. Refresh
Maintenance
Press [ ] to refresh the current system state.
The alarm system features unique and brilliant design and craftwork. Please use it with
caution. The following suggestions will help prolong the service life of the system.
2 Keep the product and accessories dry. Rainwater, moisture and liquids are likely to
contain minerals that will corrode electronic circuits.
3 Do not use or store the alarm system in dusty or dirty places; otherwise it may damage
the electronic components.
4 Do not expose the alarm system to high temperature. High temperatures can shorten
the life of electronic components, damage batteries, and cause melting and
5. Add family accounts deformation of plastic parts.
Press [ ] to enter the account management interface, and input family member’s
5 Do not store the alarm system in cold areas. Otherwise, when the temperature of the
mobile number as their login name, tag [OK]. The default password of family account is
alarm system rises to the normal level, moisture appears inside, damaging PCB.
123456, user can change it when login.
6 Test the alarm system regularly and perform troubleshooting in time.
The main account can add at most 5 family accounts. Family accounts can be deleted by
7 Check the built-in batteries of accessories regularly. If the batteries are low, replace with
tapping the [ ] on the right side in the accounts list.
new ones.
8 The alarm system requires uninterrupted power supply for working or standby.
Therefore, you need to connect the AC adapter to a reliable power outlet.
9 Avoid placing the control panel and sirens in bedrooms or offices, so as not to disturb
your rest or work.
10 It is recommended to cut off the power if the system is not used for long time.
11 If the alarm system is covered with dirt, wipe off the dirt with soft cloth or tissue. For
stains, apply diluted alkaline detergent to soft cloth, wring the cloth out and wipe the
product. Then, dry the product with dry absorbent cloth.
Please carefully read and strictly follow the previous suggestions. If the product remains
faulty, you can send it to the place of purchase or authorized maintenance center for
maintenance. We will provide help as soon as possible.
51 52
FAQ Specifications
53 54
DWC-102 Wireless Door/Window Contact
Disclaimer
Power Supply DC 1.5V (AA 1.5V LR6 Battery x 1 pc)
Static Current < 35uA Dear users:
Alarm Current < 10mA We have reviewed this manual thoroughly in order that it will be an easy to use guide
Transmitting Distance < 80m (in open area) to this product. All statements, technical information, recommendations in this manual
Radio Frequency 315MHz or 433.92MHz (±75KHz) are believed reliable, but the accuracy and completeness thereof are not guaranteed
Housing Material ABS plastic or warranted.
Operating temperature Temperature -10°C ~+ 55°C The specifications and information regarding the products in this document are
Power Supply DC 3V (AA 1.5V LR6 Battery x 2 pcs) out of the use or inability to use this document, even if the product has been advised
of the possibility of such damages.
Static Current < 90uA
Alarm Current < 9.5mA 8m/110°
Detection Scope < 25kgs
Pet Immunity < 80m (in open area)
Transmitting Distance 315MHz or 433.92MHz (±75KHz)
Radio Frequency ABS plastic
Housing Material Temperature -10°C ~+ 55°C
Operating Condition Relative humidity < 80% (non-condensing)
Detector Dimensions (L x W x H) 108 x 52 x 36.8 mm
Bracket Dimensions (L x W x H) 52 x 30 x 26.5 mm
55 56
B11
258x185mm 129x185mm
装订方式 胶粘 OI: B11-UM-EN-V1.0
注:
双面四色印刷64P