Product Data Sheet Rosemount 5900s Radar Level Gauge en 104522
Product Data Sheet Rosemount 5900s Radar Level Gauge en 104522
00813-0100-5900, Rev CC
November 2021
■ Get highest certified custody transfer accuracy of 0,5 mm for precise monitoring of bulk liquid assets
■ Increase safety with third party certified IEC 61508 SIL 2 or SIL 3 capability
■ Enable independent back-up level measurement and overfill prevention with innovative 2-in-1 functionality
■ Benefit from convenient and safe installation with 2-wire IS bus power supply
■ Include wired and/or wireless data transmission
■ Measure in all bulk storage tank types and products, ranging from liquefied gases, light products, crude oil and bitumen
Rosemount 5900S November 2021
The Rosemount 5900S is normally combined with high precision multi-spot temperature sensors. This enables accurate net volume
calculations according to API and other standards.
Contents
Improve safety and measurement accuracy.......................................................................................................................................2
Get complete level and inventory information...................................................................................................................................3
Ordering information........................................................................................................................................................................ 6
Specifications.................................................................................................................................................................................. 28
Product certifications...................................................................................................................................................................... 42
Dimensional drawings..................................................................................................................................................................... 55
2 Emerson.com/Rosemount
November 2021 Rosemount 5900S
C
J L
I
D
F
E
Emerson.com/Rosemount 3
Rosemount 5900S November 2021
The 2-in-1 solution enables real-time delta verification by configuring the transmitter to compare signals on both units.
The 2-in-1 solution uses only one tank opening, which reduces installation cost.
The still-pipe gauge uses the Low Loss H01 radar transmission mode. This mode focuses the microwave energy into the center of
the pipe, ensuring custody transfer accuracy also in old still pipes with rust and product deposits.
4 Emerson.com/Rosemount
November 2021 Rosemount 5900S
Emerson.com/Rosemount 5
Rosemount 5900S November 2021
Ordering information
Model codes
Model codes contain the details related to each product. Exact model codes will vary; an example of a typical model code is shown
in Figure 3.
Figure 3: Model Code Example
5900S P S F F I5 L 2 A 1 1P F S PF WE 0 Q4 WR3
1 2
6 Emerson.com/Rosemount
November 2021 Rosemount 5900S
Code Description
5900S Radar Level Gauge
Performance class
Code Description
P Premium: ±0.5 mm (0.020 in.) instrument accuracy
Code Description
3(1) Certified IEC 61508 SIL 3 capable
S(2) Certified IEC 61508 SIL 2 capable
F None. Ready for upgrade to Safety certification (SIS)
0 None
(1) Requires Redundancy code 2 and Rosemount 2410 with Safety certification (SIS) code 3.
(2) Requires Rosemount 2410 with either Analog output 4-20 mA or Relay output code 1 or 2.
Redundancy
Code Description
2 2-in-1: Dual independent radar level gauge electronics
F None. Ready for upgrade to 2-in-1
1 None. Single radar level gauge electronics
Emerson.com/Rosemount 7
Rosemount 5900S November 2021
Code Description
F Bus powered 2-wire FOUNDATION™ Fieldbus (IEC 61158)
Code Description
I1 ATEX Intrinsic Safety
I7 IECEx Intrinsic Safety
I5 FM-US Intrinsic Safety
I6 FM-Canada Intrinsic Safety
I2 INMETRO Intrinsic Safety (Brazil)
IP(1) KC Intrinsic Safety (South Korea)
IW CCOE/PESO Intrinsic Safety (India)
I4(2) Japan Intrinsic Safety
IM Technical Regulations Customs Union (EAC) Intrinsic Safety
NA None
(1) Requires Custody transfer type approval code R or 0.
(2) Not available with Cable entry/Conduit connections code E or M.
Code Description
R(1)(2) OIML R85 edition 2008
A(1)(3) CMI (Czech Republic)
B(1)(3) NMI (Australia)
C(3)(4) PTB Eich (Germany)
E(1)(3) TJA (Estonia)
G(1)(3) GUM (Poland)
I(1)(5) Ministero (Italy)
K(1)(3)(6) GOST (Kazakhstan)
L(5)(7) LNE (France)
M(1)(5) BMS (Belgium)
N(8)(9) NMi (The Netherlands)
O(1)(3) ONML (Algeria)
Q(1)(3) IPQ (Portugal)
S(1)(2)(6) GOST (Russia)
T(1)(3) ANM (Tunisia)
W(1)(3) METAS (Switzerland)
8 Emerson.com/Rosemount
November 2021 Rosemount 5900S
Code Description
Y(1)(3) Justervesenet (Norway)
0 None
(1) Requires integral display in Rosemount 2410 or Rosemount 2230 or Rosemount TankMaster.
(2) Requires Calibration certificate options code Q4 or QL.
(3) Requires Calibration certificate options code Q4.
(4) Requires integral display in Rosemount 2410 or Rosemount 2230 with Custody transfer approval code C or Rosemount TankMaster.
(5) Requires Calibration certificate options code S4.
(6) Requires Hazardous location certification code I1.
(7) Requires integral display in Rosemount 2410 or Rosemount 2230 with Custody transfer approval code L or Rosemount TankMaster.
(8) Requires integral display in Rosemount 2410 or Rosemount 2230 with Custody transfer approval code N or Rosemount TankMaster.
(9) Requires Calibration certificate options code S4 or SL.
Code Description
1 10 GHz FMCW radar technology
2 10 GHz FMCW radar technology for US/Russian installation
Housing
Code Description
A Standard enclosure, polyurethane-covered aluminum. IP 66/67
Code Description
1 ½ - 14 NPT, female thread. (1 plug included)
2 M20 x 1.5 adapters, female thread. (2 adapters and 1 plug included)
G Metal cable glands (½ - 14 NPT). Minimum temperature -20 °C (-4 °F). ATEX/IECEx Exe approved.
(2 glands and 1 plug included)
E eurofast® male connector (1 plug included)
M minifast® male connector (1 plug included)
Antenna
Code Description
1P Parabolic antenna
Antenna size
Code Description
F 20 in./DN 500, Ø=440 mm (17.3 in.)
Emerson.com/Rosemount 9
Rosemount 5900S November 2021
Antenna material
Code Description
S SST AISI 316L/EN 1.4436
Tank seal
Code Description
PF PTFE with FEP fluoropolymer O-ring
PK PTFE with Kalrez® perfluoroelastomer O-ring
Tank connection
Code Description
WE Welded installation
CL Clamped/threaded installation
Antenna options
Code Description
0 None
V(1) Proof test verification reflector
(1) Not available with Options code U1.
Additional options
Safety certificate
Requires Safety certification (SIS) code 3 or S.
Code Description
QT IEC 61508 certificate and FMEDA-data (printed copy)
Calibration certificate
Code Description
Q4 Calibration certificate (tank height up to 30 m (100 ft), printed copy)
QL Calibration certificate 40 m (tank height up to 40 m (130 ft), printed copy)
S4 Witnessed calibration certificate (tank height up to 30 m (100 ft), witnessed by factory selected accredited third
party)
SL Witnessed calibration certificate 40 m (witnessed by factory selected accredited third party)
10 Emerson.com/Rosemount
November 2021 Rosemount 5900S
Code Description
Q8 Antenna material traceability certification per EN 10204 3.1
Code Description
U1(1) TÜV/DIBt WHG approval for overfill protection
U2 SVTI approval for overfill protection (Switzerland)
(1) Requires one or more relay outputs in the Rosemount 2410 Tank Hub.
Tag plate
Code Description
ST Engraved SST tag plate (tag shall be submitted with order)
Code Description
WR3 3-year limited warranty
WR5 5-year limited warranty
Emerson.com/Rosemount 11
Rosemount 5900S November 2021
Code Description
5900S Radar Level Gauge
Performance class
Code Description
P Premium: ±0.5 mm (0.020 in.) instrument accuracy
Code Description
3(1) Certified IEC 61508 SIL 3 capable
S(2) Certified IEC 61508 SIL 2 capable
F None. Ready for upgrade to Safety certification (SIS)
0 None
(1) Requires Redundancy code 2 and Rosemount 2410 with Safety certification (SIS) code 3.
(2) Requires Rosemount 2410 with either Analog output 4-20 mA or Relay output code 1 or 2.
Redundancy
Code Description
2 2-in-1: Dual independent radar level gauge electronics
F None. Ready for upgrade to 2-in-1
1 None. Single radar level gauge electronics
12 Emerson.com/Rosemount
November 2021 Rosemount 5900S
Code Description
F Bus powered 2-wire FOUNDATION™ Fieldbus (IEC 61158)
Code Description
I1 ATEX Intrinsic Safety
I7 IECEx Intrinsic Safety
I5 FM-US Intrinsic Safety
I6 FM-Canada Intrinsic Safety
I2 INMETRO Intrinsic Safety (Brazil)
IP(1) KC Intrinsic Safety (South Korea)
IW CCOE/PESO Intrinsic Safety (India)
I4(2) Japan Intrinsic Safety
IM Technical Regulations Customs Union (EAC) Intrinsic Safety
NA None
(1) Requires Custody transfer type approval code R or 0.
(2) Not available with Cable entry/Conduit connections code E or M.
Code Description
R(1)(2) OIML R85 edition 2008
A(1)(2) CMI (Czech Republic)
B(1)(2) NMI (Australia)
C(2)(3) PTB Eich (Germany)
E(1)(2) TJA (Estonia)
G(1)(2) GUM (Poland)
I(1)(4) Ministero (Italy)
K(1)(2)(5) GOST (Kazakhstan)
L(4)(6) LNE (France)
M(1)(4) BMS (Belgium)
N(4)(7) NMi (The Netherlands)
O(1)(2) ONML (Algeria)
Q(1)(2) IPQ (Portugal)
S(1)(2)(5) GOST (Russia)
T(1)(2) ANM (Tunisia)
W(1)(2) METAS (Switzerland)
Emerson.com/Rosemount 13
Rosemount 5900S November 2021
Code Description
Y(1)(2) Justervesenet (Norway)
0 None
(1) Requires integral display in Rosemount 2410 or Rosemount 2230 or Rosemount TankMaster.
(2) Requires Calibration certificate options code Q4.
(3) Requires integral display in Rosemount 2410 or Rosemount 2230 with Custody transfer approval code C or Rosemount TankMaster.
(4) Requires Calibration certificate options code S4.
(5) Requires Hazardous location certification code I1.
(6) Requires integral display in Rosemount 2410 or Rosemount 2230 with Custody transfer approval code L or Rosemount TankMaster.
(7) Requires integral display in Rosemount 2410 or Rosemount 2230 with Custody transfer approval code N or Rosemount TankMaster.
Code Description
1 10 GHz FMCW radar technology
2 10 GHz FMCW radar technology for US/Russian installation
Housing
Code Description
A Standard enclosure, polyurethane-covered aluminum. IP 66/67
Code Description
1 ½ - 14 NPT, female thread. (1 plug included)
2 M20 x 1.5 adapters, female thread. (2 adapters and 1 plug included)
G Metal cable glands (½ - 14 NPT). Minimum temperature -20 °C (-4 °F). ATEX/IECEx Exe approved.
(2 glands and 1 plug included)
E eurofast® male connector (1 plug included)
M minifast® male connector (1 plug included)
Antenna
Code Description
1H Horn antenna
Antenna size
Code Description
8 8 in. / DN 200, Ø=175 mm (6.9 in.)
Antenna material
Code Description
S SST AISI 316/316L and SST EN 1.4401/1.4404
14 Emerson.com/Rosemount
November 2021 Rosemount 5900S
Tank seal
Code Description
PV PTFE with Viton® fluoroelastomer O-ring
Tank connection
Code Description
ANSI Hole Pattern (SST AISI 316/316 L) – Flat Face
8A 8 in. Class 150
8Z 8 in. Class 150, inclined 4 degrees
EN Hole Pattern (SST EN 1.4401/1.4404) – Flat Face
LA DN 200/PN 10
LZ DN 200/PN 10, inclined 4 degrees
Antenna options
Code Description
0 None
Additional options
Safety certificate
Requires Safety certification (SIS) code 3 or S.
Code Description
QT IEC 61508 certificate and FMEDA-data (printed copy)
Calibration certificate
Code Description
Q4 Calibration certificate (printed copy)
S4 Witnessed calibration certificate (witnessed by factory selected accredited third party)
Code Description
Q8 Antenna material traceability certification per EN 10204 3.1
Emerson.com/Rosemount 15
Rosemount 5900S November 2021
Code Description
U1(1) TÜV/DIBt WHG approval for overfill protection
U2 SVTI approval for overfill protection (Switzerland)
(1) Requires one or more relay outputs in the Rosemount 2410 Tank Hub.
Tag plate
Code Description
ST Engraved SST tag plate (tag shall be submitted with order)
Code Description
WR3 3-year limited warranty
WR5 5-year limited warranty
16 Emerson.com/Rosemount
November 2021 Rosemount 5900S
Code Description
5900S Radar Level Gauge
Performance class
Code Description
P Premium: ±0.5 mm (0.020 in.) instrument accuracy
Code Description
3(1) Certified IEC 61508 SIL 3 capable
S(2) Certified IEC 61508 SIL 2 capable
F None. Ready for upgrade to Safety certification (SIS)
0 None
(1) Requires Redundancy code 2 and Rosemount 2410 with Safety certification (SIS) code 3.
(2) Requires Rosemount 2410 with either Analog output 4-20 mA or Relay output code 1 or 2.
Redundancy
Code Description
2 2-in-1: Dual independent radar level gauge electronics
F None. Ready for upgrade to 2-in-1
1 None. Single radar level gauge electronics
Emerson.com/Rosemount 17
Rosemount 5900S November 2021
Code Description
F Bus powered 2-wire FOUNDATION™ Fieldbus (IEC 61158)
Code Description
I1 ATEX Intrinsic Safety
I7 IECEx Intrinsic Safety
I5 FM-US Intrinsic Safety
I6 FM-Canada Intrinsic Safety
I2 INMETRO Intrinsic Safety (Brazil)
IP(1) KC Intrinsic Safety (South Korea)
IW CCOE/PESO Intrinsic Safety (India)
I4(2) Japan Intrinsic Safety
IM Technical Regulations Customs Union (EAC) Intrinsic Safety
NA None
(1) Requires Custody transfer type approval code R or 0.
(2) Not available with Cable entry/Conduit connections code E or M.
Code Description
R(1)(2) OIML R85 edition 2008
A(1)(3) CMI (Czech Republic)
B(1)(3) NMI (Australia)
C(3)(4) PTB Eich (Germany)
E(1)(3) TJA (Estonia)
G(1)(3) GUM (Poland)
I(1)(5) Ministero (Italy)
K(1)(3)(6) GOST (Kazakhstan)
L(5)(7) LNE (France)
M(1)(5) BMS (Belgium)
N(8)(9) NMi (The Netherlands)
O(1)(3) ONML (Algeria)
Q(1)(3) IPQ (Portugal)
S(1)(2)(6) GOST (Russia)
T(1)(3) ANM (Tunisia)
W(1)(3) METAS (Switzerland)
18 Emerson.com/Rosemount
November 2021 Rosemount 5900S
Code Description
Y(1)(3) Justervesenet (Norway)
0 None
(1) Requires integral display in Rosemount 2410 or Rosemount 2230 or Rosemount TankMaster.
(2) Requires Calibration certificate options code Q4 or QL.
(3) Requires Calibration certificate options code Q4.
(4) Requires integral display in Rosemount 2410 or Rosemount 2230 with Custody transfer approval code C or Rosemount TankMaster.
(5) Requires Calibration certificate options code S4.
(6) Requires Hazardous location certification code I1.
(7) Requires integral display in Rosemount 2410 or Rosemount 2230 with Custody transfer approval code L or Rosemount TankMaster.
(8) Requires integral display in Rosemount 2410 or Rosemount 2230 with Custody transfer approval code N or Rosemount TankMaster.
(9) Requires Calibration certificate options code S4 or SL.
Code Description
1 10 GHz FMCW radar technology
2 10 GHz FMCW radar technology for US/Russian installation
Housing
Code Description
A Standard enclosure, polyurethane-covered aluminum. IP 66/67
Code Description
1 ½ - 14 NPT, female thread. (1 plug included)
2 M20 x 1.5 adapters, female thread. (2 adapters and 1 plug included)
G Metal cable glands (½ - 14 NPT). Minimum temperature -20 °C (-4 °F). ATEX/IECEx Exe approved.
(2 glands and 1 plug included)
E eurofast® male connector (1 plug included)
M minifast® male connector (1 plug included)
Antenna
Code Description
1A Still-pipe array antenna
Antenna size
Code Description
5 5 in./DN 125, Ø=120 mm (4.7 in.)
6 6 in./DN 150, Ø=145 mm (5.7 in.)
Emerson.com/Rosemount 19
Rosemount 5900S November 2021
Code Description
8 8 in./DN 200, Ø=189 mm (7.4 in.)
A 10 in./DN 250, Ø=243 mm (9.8 in.)
B 12 in./DN 300, Ø=293 mm (11.8 in.)
Antenna material
Code Description
S SST (AISI 316L / EN 1.4404) and PPS (polyphenylene sulfide)
Tank seal
Code Description
FF Fixed flange installation with fluorosilicone O-ring
HH Integrated hatch installation with fluorosilicone O-ring (direct access to pipe with hand gauge)
Tank connection
Code Description
ANSI Hole Pattern (SST AISI 316/316 L) – Flat Face
5A 5 in. Class 150
6A 6 in. Class 150
8A 8 in. Class 150
AA 10 in. Class 150
BA 12 in. Class 150
EN Hole Pattern (SST EN 1.4404) – Flat Face
KA DN 150 PN 16
LA DN 200 PN 10
MB DN 250 PN 16
Antenna options
Code Description
0 None
C Clamp flange in galvanized steel (for still-pipes without a flange). Available for 6, 8 , 10, and 12 in. tank connections.
V(1)(2)(3) Proof test verification reflector (size equal to Tank connection)
(1) Requires Antenna size code 6, 8, A, or B.
(2) Not available with Options code U1.
(3) Requires Custody transfer type approval code 0 or R.
20 Emerson.com/Rosemount
November 2021 Rosemount 5900S
Additional options
Safety certificate
Requires Safety certification (SIS) code 3 or S.
Code Description
QT IEC 61508 certificate and FMEDA-data (printed copy)
Calibration certificate
Code Description
Q4 Calibration certificate (tank height up to 30 m (100 ft), printed copy)
QL Calibration certificate 40 m (tank height up to 40 m (130 ft), printed copy)
S4 Witnessed calibration certificate (tank height up to 30 m (100 ft), witnessed by factory selected accredited third
party)
SL Witnessed calibration certificate 40 m (witnessed by factory selected accredited third party)
Code Description
Q8 Antenna material traceability certification per EN 10204 3.1
Code Description
U1(1) TÜV/DIBt WHG approval for overfill protection
U2 SVTI approval for overfill protection (Switzerland)
(1) Requires one or more relay outputs in the Rosemount 2410 Tank Hub.
Tag plate
Code Description
ST Engraved SST tag plate (tag shall be submitted with order)
Code Description
WR3 3-year limited warranty
WR5 5-year limited warranty
Emerson.com/Rosemount 21
Rosemount 5900S November 2021
Code Description
5900S Radar Level Gauge
Performance class
Code Description
P Premium: ±0.5 mm (0.020 in.) instrument accuracy
Code Description
3(1) Certified IEC 61508 SIL 3 capable
S(2) Certified IEC 61508 SIL 2 capable
F None. Ready for upgrade to Safety certification (SIS)
0 None
(1) Requires Redundancy code 2 and Rosemount 2410 with Safety certification (SIS) code 3.
(2) Requires Rosemount 2410 with either Analog output 4-20 mA or Relay output code 1 or 2.
22 Emerson.com/Rosemount
November 2021 Rosemount 5900S
Redundancy
Code Description
2 2-in-1: Dual independent radar level gauge electronics
F None. Ready for upgrade to 2-in-1
1 None. Single radar level gauge electronics
Code Description
F Bus powered 2-wire FOUNDATION™ Fieldbus (IEC 61158)
Code Description
I1 ATEX Intrinsic Safety
I7 IECEx Intrinsic Safety
I5 FM-US Intrinsic Safety
I6 FM-Canada Intrinsic Safety
I2 INMETRO Intrinsic Safety (Brazil)
IP(1) KC Intrinsic Safety (South Korea)
IW CCOE/PESO Intrinsic Safety (India)
I4(2) Japan Intrinsic Safety
IM Technical Regulations Customs Union (EAC) Intrinsic Safety
NA None
(1) Requires Custody transfer type approval code R or 0.
(2) Not available with Cable entry/Conduit connections code E or M.
Code Description
R(1)(2) OIML R85 edition 2008
A(1)(3) CMI (Czech Republic)
B(1)(3) NMI (Australia)
C(3)(4) PTB Eich (Germany)
E(1)(3) TJA (Estonia)
G(1)(3) GUM (Poland)
I(1)(5) Ministero (Italy)
K(1)(3)(6) GOST (Kazakhstan)
L(5)(7) LNE (France)
M(1)(5) BMS (Belgium)
Emerson.com/Rosemount 23
Rosemount 5900S November 2021
Code Description
N(8)(9) NMi (The Netherlands)
O(1)(3) ONML (Algeria)
Q(1)(3) IPQ (Portugal)
S(1)(2)(6) GOST (Russia)
T(1)(3) ANM (Tunisia)
W(1)(3) METAS (Switzerland)
Y(1)(3) Justervesenet (Norway)
0 None
(1) Requires integral display in Rosemount 2410 or Rosemount 2230 or Rosemount TankMaster.
(2) Requires Calibration certificate options code Q4 or QL.
(3) Requires Calibration certificate options code Q4.
(4) Requires integral display in Rosemount 2410 or Rosemount 2230 with Custody transfer approval code C or Rosemount TankMaster.
(5) Requires Calibration certificate options code S4.
(6) Requires Hazardous location certification code I1.
(7) Requires integral display in Rosemount 2410 or Rosemount 2230 with Custody transfer approval code L or Rosemount TankMaster.
(8) Requires integral display in Rosemount 2410 or Rosemount 2230 with Custody transfer approval code N or Rosemount TankMaster.
(9) Requires Calibration certificate options code S4 or SL.
Code Description
1 10 GHz FMCW radar technology
2 10 GHz FMCW radar technology for US/Russian installation
Housing
Code Description
A Standard enclosure, polyurethane-covered aluminum. IP 66/67
Code Description
1 ½ - 14 NPT, female thread. (1 plug included)
2 M20 x 1.5 adapters, female thread. (2 adapters and 1 plug included)
G Metal cable glands (½ - 14 NPT). Minimum temperature -20 °C (-4 °F). ATEX/IECEx Exe approved.
(2 glands and 1 plug included)
E eurofast® male connector (1 plug included)
M minifast® male connector (1 plug included)
24 Emerson.com/Rosemount
November 2021 Rosemount 5900S
Antenna
Code Description
G1 LPG/LNG (liquefied gas) still-pipe antenna (with integrated ball-valve, without pressure transmitter)
G2(1) LPG/LNG (liquefied gas) still-pipe antenna (with integrated ball-valve and pressure transmitter)
G4(1)(2) LPG/LNG (liquefied gas) still-pipe antenna (with integrated ball-valve and dual pressure transmitters)
(1) Requires Hazardous location certification code I1, I2, I5, I6, I7, IP, I4, or IM.
(2) Requires Redundancy code 2.
Related information
Rosemount 5900S with LPG/LNG antenna
Antenna size
Code Description
A 4 in. Schedule 10, Ø=107 mm (4.2 in.)
B 4 in. Schedule 40, Ø=101 mm (4.0 in.)
D DN 100, Ø=99 mm (3.9 in.)
Antenna material
Code Description
S SST AISI 316/316L and SST EN1.4401/1.4404
Tank seal
Code Description
PT PTFE sealing
Tank connection
Code Description
ANSI Flanges (SST AISI 316/316 L) – Raised Face
1B(1)(2)(3) 1.5 in. Class 300
2A(1)(2)(3) 2 in. Class 150
2B(1)(2)(3) 2 in. Class 300
3A(1)(2)(3) 3 in. Class 150
3B(1)(2)(3) 3 in. Class 300
4A 4 in. Class 150
4B 4 in. Class 300
6A 6 in. Class 150
6B 6 in. Class 300
8A 8 in. Class 150
8B 8 in. Class 300
Emerson.com/Rosemount 25
Rosemount 5900S November 2021
Code Description
EN Hole Pattern (SST EN 1.4404 ) – Raised Face B1
NA DN 100 PN40
OA DN 150 PN40
PA DN 200 PN25
PB DN 200 PN40
(1) Requires Antenna size code A.
(2) Requires Custody transfer type approval code R or 0.
(3) Not available with Safety certification (SIS) code 3.
Antenna options
Code Description
V Measurement verification kit with 1 verification pin and 1 pipe end deflector kit
Additional options
Safety certificate
Requires Safety certification (SIS) code 3 or S.
Code Description
QT IEC 61508 certificate and FMEDA-data (printed copy)
Calibration certificate
Code Description
Q4 Calibration certificate (tank height up to 30 m (100 ft), printed copy)
QL Calibration certificate 40 m (tank height up to 40 m (130 ft), printed copy)
S4 Witnessed calibration certificate (tank height up to 30 m (100 ft), witnessed by factory selected accredited third
party)
SL Witnessed calibration certificate 40 m (witnessed by factory selected accredited third party)
Code Description
Q8 Antenna material traceability certification per EN 10204 3.1
Code Description
U1(1) TÜV/DIBt WHG approval for overfill protection
U2 SVTI approval for overfill protection (Switzerland)
(1) Requires one or more relay outputs in the Rosemount 2410 Tank Hub.
26 Emerson.com/Rosemount
November 2021 Rosemount 5900S
Tag plate
Code Description
ST Engraved SST tag plate (tag shall be submitted with order)
Code Description
P1 Antenna hydrostatic pressure testing
Code Description
WR3 3-year limited warranty
WR5 5-year limited warranty
Emerson.com/Rosemount 27
Rosemount 5900S November 2021
Specifications
General
Instrument accuracy
Rosemount 5900S standard version ± 0.5 mm (0.020 in.)
Rosemount 5900S 2-in-1 version ± 0.5 mm (0.020 in.)(1)
Instrument accuracy is under reference conditions. Reference conditions are: Measurement in test bench at Rosemount Tank Radar
AB in Mölnlycke Sweden. Test bench is calibrated minimum yearly by an accredited laboratory: RISE Research Institutes of Sweden.
Measuring range is up to 40 m (130 ft). Ambient temperature and humidity is close to constant during tests. Total uncertainty in
test bench is below 0.15 mm (0.006 in.).
Temperature stability
Typically < ± 0.5 mm (0.020 in.) in -40 to +70 °C (-40 to +158 °F)
Fieldbus (standard)
FOUNDATION™ Fieldbus FISCO (Tankbus)
Update time
New measurement every 0.3 s
Repeatability
0.2 mm (0.008 in.)
Installation considerations
See Rosemount 5900S Reference Manual
Measurement principle
The FMCW-method (Frequency Modulated Continuous Wave) means that the transmitted radar signal has a linear frequency
variation around 10 GHz. The reflection from the liquid surface has a slightly different frequency compared with the signal
transmitted from the antenna when the reflection is received. The difference in frequency is directly proportional to the distance
between the antenna and the liquid surface, and thereby also the liquid level. This technology enables a very accurate and stable
measured value.
28 Emerson.com/Rosemount
November 2021 Rosemount 5900S
A. Frequency, f (GHz)
B. Time, t (s)
Communication/Display/Configuration
Configuration tools
Rosemount TankMaster WinSetup, Field Communicator
Emerson.com/Rosemount 29
Rosemount 5900S November 2021
™
FOUNDATION Fieldbus characteristics
Polarity sensitive
No
Device capacitance/inductance
See Product certifications.
Links
Maximum 40
Instantiation
Yes
30 Emerson.com/Rosemount
November 2021 Rosemount 5900S
Advanced diagnostics
Software, memory/database, electronics, internal communication, simulation, level correction, level measurement, ambient
temperature, vapor pressure/temperature correction, LPG verification pin, and manual measurement values.
Emerson.com/Rosemount 31
Rosemount 5900S November 2021
Electric
Tankbus cabling
0.5-1.5 mm2 (AWG 22-16), twisted shielded pairs
Power supply
FISCO: 9.0 - 17.5 VDC polarity insensitive (for example from Rosemount 2410 Tank Hub)
Entity: 9.0 - 30.0 VDC polarity insensitive
32 Emerson.com/Rosemount
November 2021 Rosemount 5900S
Mechanical
Total weight
Table 2: Weight of Transmitter Head
Antennas
The Rosemount 5900S antennas have a drip-off design which for some versions also include inclined polished PTFE surfaces.
Condensation on the antenna is minimized, and the radar signal remains strong. This results in maintenance free operation, high
accuracy and reliability. There is always a suitable antenna for every tank type, tank opening and application:
■ Parabolic
■ Horn
■ Still-pipe array
■ LPG/LNG
Emerson.com/Rosemount 33
Rosemount 5900S November 2021
Transmitter head
The same transmitter head is used for all Rosemount 5900S antenna types, minimizing spare part requirements:
■ The dual compartment transmitter housing, with electronics and cabling separated, can be replaced without opening the tank
■ It is protected against lightning, moisture/rain, and has a surface protection against sulphur and salt spray atmospheres
■ Electronics consists of one or two encapsulated units. The 2-in-1 solution has duplicate, galvanically isolated electronic units in
the same housing
■ No need for re-calibration
34 Emerson.com/Rosemount
November 2021 Rosemount 5900S
Environment
Storage temperature
-50 to +85 °C (-58 to +185 °F)
Humidity
0-100% relative humidity
Ingress protection
IP 66/67 and NEMA® 4X
Vibration resistance
IEC 60770-1 level 1 and IACS UR E10 test 7
Telecommunication
Compliance with:
■ FCC 15B Class A, and 15C
■ RED (EU directive 2014/53/EU) ETSI EN 302372; EN 50371
■ IC (RSS210-5)
Electromagnetic compatibility
■ EMC (EU directive 2014/30/EU) EN 61326-1; EN 61326-3-1
■ OIML R85:2008
Emerson.com/Rosemount 35
Rosemount 5900S November 2021
Wiring
Separated or common
Separation
Galvanically separated gauge electronics, and shared antenna
Wiring
■ Additional separate 2-wire cable for alarm or
■ A single cable incorporating two 2-wire cables (alarm and level)
36 Emerson.com/Rosemount
November 2021 Rosemount 5900S
Measuring range
0.8 to 40 m (2.6 to 130 ft) below flange(2)
Possibility to measure 0.5 to 50 m (1.6 to 164 ft). Accuracy may be reduced. For longer measuring range, consult your local
representative.
Pressure range
Clamped/threaded: -0.2 to 0.2 bar (-2.9 to 2.9 psig)
Welded: -0.2 to 10 bar (-2.9 to 145 psig)
Antenna dimension
440 mm (17 in.)
Emerson.com/Rosemount 37
Rosemount 5900S November 2021
Measuring range
0.8 to 20 m (2.6 to 65 ft) below flange.
Possibility to measure 0.5 to 30 m (1.6 to 100 ft). Accuracy may be reduced. For longer measuring range, consult your local
representative.
Pressure range
-0.2 to 2 bar (-2.9 to 29 psig)
Antenna dimension
175 mm (7 in.)
Nozzle diameter
Minimum 200 mm (8 in.)
Tank connection
The flange can be horizontal or 4° inclined for installation close to the tank wall.
The horizontal flange is used when highest accuracy and reliability is required. The 4° inclined version can be used to maintain high
accuracy when the gauge is installed close to the tank wall.
38 Emerson.com/Rosemount
November 2021 Rosemount 5900S
Measuring range
0.8 to 40 m (2.6 to 130 ft) below flange(3)
The minimum range can be extended to 0.5 m (1.6 ft) with slightly reduced accuracy. For longer measuring range, consult your
local representative.
Pressure range
Fixed version: -0.2 to 2 bar (-2.9 to 29 psig) at 20 °C (68 °F).
Hinged hatch version: -0.2 to 0.5 bar (-2.9 to 7.2 psig) for 5 to 8-in. pipes.
-0.2 to 0.25 bar (-2.9 to 3.6 psig) for 10 and 12-in. pipes.
Still-pipe dimensions
5-, 6-, 8-, 10- or 12 in.
Tank connection
5 in. hole pattern according to ANSI 5 in. Class 150
6 in. hole pattern according to ANSI 6 in. Class 150 / DN 150 PN 16
8 in. hole pattern according to ANSI 8 in. Class 150 / DN 200 PN 10
10 in. hole pattern according to ANSI 10 in. Class 150 / DN 250 PN 16
12 in. hole pattern according to ANSI 12 in. Class 150
Emerson.com/Rosemount 39
Rosemount 5900S November 2021
Measuring range
1.2 to 40 m (3.9 to 130 ft) below flange(4)
Possibility to measure 0.8 to 60 m (2.6 to 200 ft). Accuracy may be reduced. For longer measuring range, consult your local
representative.
Pressure range
-1 to 25 bar (-14.5 to 365 psig).
Note! Flanges may have higher pressure rating than 25 bar, but maximum tank pressure is still 25 bar.
Pressure seal
The pressure seal includes a double-block function, consisting of a PTFE seal and a fire-proof ball valve. A pressure sensor enables
correction due to vapor for best measurement performance.
40 Emerson.com/Rosemount
November 2021 Rosemount 5900S
Verification possibility
A patented reference device function enables measurement verification with the tank in service. A verification pin mounted in a
still-pipe hole, and a deflection plate with a verification ring at the lower still-pipe end provide reference echoes at fixed pre-defined
distances.
Emerson.com/Rosemount 41
Rosemount 5900S November 2021
Product certifications
Rev 7.28
Telecommunication compliance
FCC
This device complies with Part 15C of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not
cause interference, and (2) this device must accept any interference received, including interference that may cause undesired
operation.
Certificate: K8C5900
IC
This device complies with RSS210-7.
Certificate: 2827A-5900
CE-mark
The product complies with applicable EU directives (EMC, ATEX, LVD, and RED). Based on the low emitted effects from the gauges
(below 0.1 mW) compared to limits given by the Rec. 1999/519/EC, no additional measures are needed.
42 Emerson.com/Rosemount
November 2021 Rosemount 5900S
North America
Ui (Vmax) Ii (lmax) Pi Ci Li
Entity parameters 30 V 300 mA 1.3 W 1.1 nF 1.5 µH
FISCO parameters 17.5V 380 mA 5.32 W 1.1 nF 1.5 µH
When option n=Tank Seal O-ring Type Min/Max Process Temperature Range
PV or QV Viton -15°C to +180°C
PK, FK, HK or QK Kalrez -20°C to +230°C
PE or QE EPDM -40°C to +110°C
PB or QB BUNA-N -35°C to +90°C
PM, FF, HH or QM FVMQ -60°C to +155°C
PF or QF FEP -60°C to +180°C
Emerson.com/Rosemount 43
Rosemount 5900S November 2021
Ui (Vmax) Ii (lmax) Pi Ci Li
Entity parameters 30 V 300 mA 1.3 W 1.1 nF 1.5 µH
FISCO parameters 17.5V 380 mA 5.32 W 1.1 nF 1.5 µH
When option n=Tank Seal O-ring Type Min/Max Process Temperature Range
PV or QV Viton -15°C to +180°C
PK, FK, HK or QK Kalrez -20°C to +230°C
PE or QE EPDM -40°C to +110°C
PB or QB BUNA-N -35°C to +90°C
PM, FF, HH or QM FVMQ -60°C to +155°C
PF or QF FEP -60°C to +180°C
44 Emerson.com/Rosemount
November 2021 Rosemount 5900S
Europe
Ui (Vmax) Ii (lmax) Pi Ci Li
Entity parameters 30 V 300 mA 1.3 W 1.1 nF 1.5 µH
FISCO parameters 17.5V 380 mA 5.32 W 1.1 nF 1.5 µH
When option n=Tank Seal O-ring Type Min/Max Process Temperature Range
PV or QV Viton -15°C to +180°C
PK, FK, HK or QK Kalrez -20°C to +230°C
PE or QE EPDM -40°C to +110°C
PB or QB BUNA-N -35°C to +90°C
PM, FF, HH or QM FVMQ -60°C to +155°C
PF or QF FEP -60°C to +180°C
Emerson.com/Rosemount 45
Rosemount 5900S November 2021
International
Ui (Vmax) Ii (lmax) Pi Ci Li
Entity parameters 30 V 300 mA 1.3 W 1.1 nF 1.5 µH
FISCO parameters 17.5V 380 mA 5.32 W 1.1 nF 1.5 µH
When option n=Tank Seal O-ring Type Min/Max Process Temperature Range
PV or QV Viton -15°C to +180°C
PK, FK, HK or QK Kalrez -20°C to +230°C
PE or QE EPDM -40°C to +110°C
PB or QB BUNA-N -35°C to +90°C
PM, FF, HH or QM FVMQ -60°C to +155°C
PF or QF FEP -60°C to +180°C
46 Emerson.com/Rosemount
November 2021 Rosemount 5900S
Brazil
Ui (Vmax) Ii (lmax) Pi Ci Li
Entity parameters 30 V 300 mA 1.3 W 1.1 nF 1.5 µH
FISCO parameters 17.5V 380 mA 5.32 W 1.1 nF 1.5 µH
China
Ui (Vmax) Ii (lmax) Pi Ci Li
Entity parameters 30 V 300 mA 1.3 W 1.1 nF 1.5 µH
FISCO parameters 17.5V 380 mA 5.32 W 1.1 nF 1.5 µH
Emerson.com/Rosemount 47
Rosemount 5900S November 2021
Ui (Vmax) Ii (lmax) Pi Ci Li
Entity parameters 30 V 300 mA 1.3 W 1.1 nF 1.5 µH
FISCO parameters 17.5V 380 mA 5.32 W 1.1 nF 1.5 µH
Ex
TR CU 012/2011 “On safety of equipment intended for use in explosive atmospheres”
Japan
Ui (Vmax) Ii (lmax) Pi Ci Li
FISCO parameters 17.5V 380 mA 5.32 W 1.1 nF 1.5 µH
Entity parameters 30 V 300 mA 1.3 W 1.1 nF 1.5 µH
48 Emerson.com/Rosemount
November 2021 Rosemount 5900S
Republic of Korea
Ui (Vmax) Ii (lmax) Pi Ci Li
Entity parameters 30 V 300 mA 1.3 W 1.1 nF 1.5 µH
FISCO parameters 17.5V 380 mA 5.32 W 1.1 nF 1.5 µH
India
India Ex Certification
Certificate P463068/1
Ui (Vmax) Ii (lmax) Pi Ci Li
Entity parameters 30 V 300 mA 1.3 W 1.1 nF 1.5 µH
FISCO parameters 17.5V 380 mA 5.32 W 1.1 nF 1.5 µH
Intrinsic Safety
Certificate 20-11-28736/Q20-11-001012
Markings Same as IECEx (I7)
Emerson.com/Rosemount 49
Rosemount 5900S November 2021
Additional certifications
S Functional Safety
50 Emerson.com/Rosemount
November 2021 Rosemount 5900S
Certificate No 5/1/7
Standards Regulation 60: National Measurement Regulations 1999
Bulgaria 18.10.5106.1
Institute of
Metrology
Certificate 2012-L134
Certificate 558-02-01_01-15-2
Certificate 0111-CS-C022-10
Certificate PTB-1.5-4058175
Certificate IND/13/12/191
Emerson.com/Rosemount 51
Rosemount 5900S November 2021
Certificate P12_101.12_31
Certificate 393-7_0-01-2088
Certificate R85/2008-A-SE1-2021.01
52 Emerson.com/Rosemount
November 2021 Rosemount 5900S
North America
IE USA FISCO
Certificate FM16US0231X
Standards FM Class 3600 – 2011, FM Class 3610 – 2010, FM Class 3611 – 2004, FM Class 3810 – 2005
Markings IS CL I, DIV 1, GP A, B, C, D when connected per Rosemount drawing 02051-1009 (-50°C ≤ Ta ≤ +60°C); Type 4x
Certificate 2041384
Standards CSA Std. C22.2 No. 142 - M1987, CSA Std. C22.2 No. 213 - M1987, CSA Std. C22.2 No. 157 - 92, ANSI/ISA
12.27.01 – 2003, CAN/CSA-E60079-0:07, CAN/CSA-E60079-11:02
Markings Intrinsically safe for Class I, Division 1, Groups A, B, C, and D when connected in accordance with Rosemount
drawing 02051-1008. Ex ia IIC T3C. Single Seal. Enclosure Type 4X
Europe
IA ATEX FISCO
Certificate Baseefa08ATEX0129X
Standards EN60079-0:2012+A11:2013, EN60079-11:2012
Markings II 1 G Ex ia IIC T4 Ga (-60°C ≤ Ta ≤ +60°C)
Ui Ii Pi Ci Li
FISCO parameters 17.5V 380 mA 5.32 W 0 µF 0 mH
Emerson.com/Rosemount 53
Rosemount 5900S November 2021
International
IG IECEx FISCO
Certificate IECExBAS08.0045X
Standards IEC60079-0:2011, IEC60079-11:2011
Markings Ex ia IIC T4 Ga (-60°C ≤ Ta ≤ +60°C)
Ui Ii Pi Ci Li
FISCO parameters 17.5V 380 mA 5.32 W 0 nF 0 µH
54 Emerson.com/Rosemount
November 2021 Rosemount 5900S
Dimensional drawings
Figure 5: Dimensions of Rosemount 5900S with Parabolic Antenna
226 (8.9) 177 (7.0)
244 (9.6)
297 (11.7)
170 (6.7)
440 (17.3)
Emerson.com/Rosemount 55
Rosemount 5900S November 2021
224 (8.8)
332 (13.1)
M32
350 (13.8)
Ø 175 (6.9)
A. Flange Inclined 4°
Dimensions are in millimeters (inches).
56 Emerson.com/Rosemount
November 2021 Rosemount 5900S
224 (9.6)
290 (11.4)
B
Emerson.com/Rosemount 57
Rosemount 5900S November 2021
244 (9.6)
A
58 Emerson.com/Rosemount
November 2021 Rosemount 5900S
Emerson.com/Rosemount 59
00813-0100-5900
Rev. CC