Product Data Sheet

00813-0100-5900, Rev CC
November 2021

Rosemount™ 5900S Radar Level Gauge


High performance level measurement for tank gauging
systems

■ Get highest certified custody transfer accuracy of 0,5 mm for precise monitoring of bulk liquid assets
■ Increase safety with third party certified IEC 61508 SIL 2 or SIL 3 capability
■ Enable independent back-up level measurement and overfill prevention with innovative 2-in-1 functionality
■ Benefit from convenient and safe installation with 2-wire IS bus power supply
■ Include wired and/or wireless data transmission
■ Measure in all bulk storage tank types and products, ranging from liquefied gases, light products, crude oil and bitumen
Rosemount 5900S November 2021

Improve safety and measurement accuracy


Highest level precision for your bulk liquid storage tanks
The Rosemount 5900S radar gauge with its 0.5 mm instrument accuracy reduces level measurement uncertainty to a minimum. It
enhances your storage operation by providing:
■ Certified custody transfer accuracy according to OIML and other legal metrological authorities
■ Better inventory management
■ Reliable loss control data

The Rosemount 5900S is normally combined with high precision multi-spot temperature sensors. This enables accurate net volume
calculations according to API and other standards.

Make operations more efficient


■ No moving parts and no contact with the liquid gives increased reliability and fewer interruptions
■ Most Rosemount 5900S antenna types are installed with the tanks in operation
■ Emerson wireless solution can drastically reduce installation cost and give you access to remote tanks
■ The Rosemount 5900S gauge is available with antennas for all bulk liquid storage applications and tank types

Taking overfill safety to a higher level


■ Innovative 2-in-1 feature with two radar gauges in one housing for independent level and overfill measurement
■ SIL 2 and SIL 3 certified safety according to IEC 61508
■ Enables API 2350 compliant solutions

Contents
Improve safety and measurement accuracy.......................................................................................................................................2
Get complete level and inventory information...................................................................................................................................3
Ordering information........................................................................................................................................................................ 6
Specifications.................................................................................................................................................................................. 28
Product certifications...................................................................................................................................................................... 42
Dimensional drawings..................................................................................................................................................................... 55

2 Emerson.com/Rosemount
November 2021 Rosemount 5900S

Get complete level and inventory information


The Rosemount 5900S is a premium non-contact radar level gauge, suitable for tank terminals and refineries. It is integrated into a
high performance tank gauging system including average temperature measurement, free water level, pressure and API standard
net volumes. See also Rosemount Tank Gauging System Data Sheet (SDS).
Data is displayed locally and on a host computer or via the Rosemount TankMaster™ inventory software in the control room.
Figure 1: Tank Gauging System Overview
A
B G H K

C
J L
I
D
F
E

A. Rosemount TankMaster Inventory Management


B. Rosemount TankMaster Mobile Inventory Management
C. Modbus® RTU/TCP
D. Rosemount 2460 System Hub
E. Tankbus
F. Rosemount 2410 Tank Hub
G. Rosemount 2240S Multi-input Temperature Transmitter with Rosemount 765 Multiple Spot Temperature and Water Level Sensor
H. Rosemount 5900S Radar Level Gauge
I. Rosemount 2230 Graphical Field Display
J. Rosemount 3051S Pressure Transmitter
K. Rosemount 5900C Radar Level Gauge
L. Rosemount 644 Temperature Transmitter with Rosemount 65, 114C, or 214C Single Point Temperature Sensor

SIL safety functions


Rosemount 5900S is certified SIL 2 and SIL 3 capable for use in overfill prevention systems via outputs from the Rosemount 2410
Tank Hub connected to the gauge. The alarm signal can be connected to an Emergency Shut-down System (ESD)/Automatic
Overfill Prevention System (AOPS).
SIL 2 is achieved via the 4-20 mA output or via a safety relay. SIL 3 requires a Rosemount 5900S with the 2-in-1 option. The Safety
Instrumented System (SIS) functionality activates a separate alarm loop at a preset liquid level and triggers the safety relay or
analog output in the tank hub.

Emerson.com/Rosemount 3
Rosemount 5900S November 2021

2-in-1 gauge for cost-efficient level measurement redundancy


The Rosemount 5900S gauge can be delivered with two independent units in one housing. This unique 2-in-1 solution gives you
one primary and one backup level unit, or one level gauge plus an independent radar based High-High level alarm. It means that the
single Rosemount 5900S 2-in-1 can serve as a safety certified level device in two independent protection layers (i e BPCS and SIS).
Figure 2: Rosemount 5900S with Two Galvanically Separated Gauges within the Same Housing (2-in-1 Solution)

The 2-in-1 solution enables real-time delta verification by configuring the transmitter to compare signals on both units.
The 2-in-1 solution uses only one tank opening, which reduces installation cost.

Innovative antenna technology


The drip-off design with inclined polished PTFE surfaces on the antenna enables highest performance by reducing condensation
from product and water.

The still-pipe gauge uses the Low Loss H01 radar transmission mode. This mode focuses the microwave energy into the center of
the pipe, ensuring custody transfer accuracy also in old still pipes with rust and product deposits.

4 Emerson.com/Rosemount
November 2021 Rosemount 5900S

Access information when you need it with asset tags


Newly shipped devices include a unique QR code asset tag that enables you to access serialized information directly from the
device. With this capability, you can:
■ Access device drawings, diagrams, technical documentation, and troubleshooting information in your MyEmerson account
■ Improve mean time to repair and maintain efficiency
■ Ensure confidence that you have located the correct device
■ Eliminate the time-consuming process of locating and transcribing nameplates to view asset information

Emerson.com/Rosemount 5
Rosemount 5900S November 2021

Ordering information

Model codes
Model codes contain the details related to each product. Exact model codes will vary; an example of a typical model code is shown
in Figure 3.
Figure 3: Model Code Example
5900S P S F F I5 L 2 A 1 1P F S PF WE 0 Q4 WR3
1 2

1. Required model components (choices available on most)


2. Additional options (variety of features and functions that may be added to products)

6 Emerson.com/Rosemount
November 2021 Rosemount 5900S

Rosemount 5900S Radar Level Gauge with parabolic antenna


Rosemount 5900S with parabolic antenna is a premium non-contact radar level gauge. The
parabolic antenna is the first choice for installation on tanks with fixed roofs without a still-
pipe. It can be installed on existing manhole covers and close to the tank wall due to the
narrow radar beam and high signal to noise ratio. In certain cases, it can be used on tanks
with floating roofs to measure the distance down to a target plate on the floating roof.
■ Measures all products ranging from light products to heavy fuel oil, bitumen and asphalt
■ Antenna design gives extreme tolerance to product build-up and condensation
■ Custody transfer accuracy according to OIML R85:2008
■ Certified SIL 2 and SIL 3 capable according to IEC 61508
■ 2-in-1 functionality available for redundant level measurement
■ Communicates via a 2-wire, low voltage Tankbus for easy and safe installation
■ Installation normally with tank in service

VIEW PRODUCT >

Required model components


Model

Code Description
5900S Radar Level Gauge

Performance class

Code Description
P Premium: ±0.5 mm (0.020 in.) instrument accuracy

Safety certification (SIS)

Code Description
3(1) Certified IEC 61508 SIL 3 capable
S(2) Certified IEC 61508 SIL 2 capable
F None. Ready for upgrade to Safety certification (SIS)
0 None
(1) Requires Redundancy code 2 and Rosemount 2410 with Safety certification (SIS) code 3.
(2) Requires Rosemount 2410 with either Analog output 4-20 mA or Relay output code 1 or 2.

Redundancy

Code Description
2 2-in-1: Dual independent radar level gauge electronics
F None. Ready for upgrade to 2-in-1
1 None. Single radar level gauge electronics

Emerson.com/Rosemount 7
Rosemount 5900S November 2021

Tankbus: Power and communication

Code Description
F Bus powered 2-wire FOUNDATION™ Fieldbus (IEC 61158)

Hazardous location certification

Code Description
I1 ATEX Intrinsic Safety
I7 IECEx Intrinsic Safety
I5 FM-US Intrinsic Safety
I6 FM-Canada Intrinsic Safety
I2 INMETRO Intrinsic Safety (Brazil)
IP(1) KC Intrinsic Safety (South Korea)
IW CCOE/PESO Intrinsic Safety (India)
I4(2) Japan Intrinsic Safety
IM Technical Regulations Customs Union (EAC) Intrinsic Safety
NA None
(1) Requires Custody transfer type approval code R or 0.
(2) Not available with Cable entry/Conduit connections code E or M.

Custody transfer type approval


Requires the same Custody transfer type approval code for both the Rosemount 2410 and the Rosemount 5900S.

Code Description
R(1)(2) OIML R85 edition 2008
A(1)(3) CMI (Czech Republic)
B(1)(3) NMI (Australia)
C(3)(4) PTB Eich (Germany)
E(1)(3) TJA (Estonia)
G(1)(3) GUM (Poland)
I(1)(5) Ministero (Italy)
K(1)(3)(6) GOST (Kazakhstan)
L(5)(7) LNE (France)
M(1)(5) BMS (Belgium)
N(8)(9) NMi (The Netherlands)
O(1)(3) ONML (Algeria)
Q(1)(3) IPQ (Portugal)
S(1)(2)(6) GOST (Russia)
T(1)(3) ANM (Tunisia)
W(1)(3) METAS (Switzerland)

8 Emerson.com/Rosemount
November 2021 Rosemount 5900S

Code Description
Y(1)(3) Justervesenet (Norway)
0 None
(1) Requires integral display in Rosemount 2410 or Rosemount 2230 or Rosemount TankMaster.
(2) Requires Calibration certificate options code Q4 or QL.
(3) Requires Calibration certificate options code Q4.
(4) Requires integral display in Rosemount 2410 or Rosemount 2230 with Custody transfer approval code C or Rosemount TankMaster.
(5) Requires Calibration certificate options code S4.
(6) Requires Hazardous location certification code I1.
(7) Requires integral display in Rosemount 2410 or Rosemount 2230 with Custody transfer approval code L or Rosemount TankMaster.
(8) Requires integral display in Rosemount 2410 or Rosemount 2230 with Custody transfer approval code N or Rosemount TankMaster.
(9) Requires Calibration certificate options code S4 or SL.

Level measurement method

Code Description
1 10 GHz FMCW radar technology
2 10 GHz FMCW radar technology for US/Russian installation

Housing

Code Description
A Standard enclosure, polyurethane-covered aluminum. IP 66/67

Cable entry/Conduit connections

Code Description
1 ½ - 14 NPT, female thread. (1 plug included)
2 M20 x 1.5 adapters, female thread. (2 adapters and 1 plug included)
G Metal cable glands (½ - 14 NPT). Minimum temperature -20 °C (-4 °F). ATEX/IECEx Exe approved.
(2 glands and 1 plug included)
E eurofast® male connector (1 plug included)
M minifast® male connector (1 plug included)

Antenna

Code Description
1P Parabolic antenna

Antenna size

Code Description
F 20 in./DN 500, Ø=440 mm (17.3 in.)

Emerson.com/Rosemount 9
Rosemount 5900S November 2021

Antenna material

Code Description
S SST AISI 316L/EN 1.4436

Tank seal

Code Description
PF PTFE with FEP fluoropolymer O-ring
PK PTFE with Kalrez® perfluoroelastomer O-ring

Tank connection

Code Description
WE Welded installation
CL Clamped/threaded installation

Antenna options

Code Description
0 None
V(1) Proof test verification reflector
(1) Not available with Options code U1.

Additional options
Safety certificate
Requires Safety certification (SIS) code 3 or S.

Code Description
QT IEC 61508 certificate and FMEDA-data (printed copy)

Calibration certificate

Code Description
Q4 Calibration certificate (tank height up to 30 m (100 ft), printed copy)
QL Calibration certificate 40 m (tank height up to 40 m (130 ft), printed copy)
S4 Witnessed calibration certificate (tank height up to 30 m (100 ft), witnessed by factory selected accredited third
party)
SL Witnessed calibration certificate 40 m (witnessed by factory selected accredited third party)

10 Emerson.com/Rosemount
November 2021 Rosemount 5900S

Material traceability certificate


Not available for transmitter head sparepart.

Code Description
Q8 Antenna material traceability certification per EN 10204 3.1

Overfill protection approval

Code Description
U1(1) TÜV/DIBt WHG approval for overfill protection
U2 SVTI approval for overfill protection (Switzerland)
(1) Requires one or more relay outputs in the Rosemount 2410 Tank Hub.

Tag plate

Code Description
ST Engraved SST tag plate (tag shall be submitted with order)

Extended product warranty


Rosemount extended warranties have a limited warranty of three or five years from date of shipment.

Code Description
WR3 3-year limited warranty
WR5 5-year limited warranty

Emerson.com/Rosemount 11
Rosemount 5900S November 2021

Rosemount 5900S Radar Level Gauge with horn antenna


Rosemount 5900S with horn antenna is a non-contact radar level gauge. It is designed for easy
installation on fixed roofs tanks, with smaller nozzles, down to 200 mm (8 in.).
■ Measures on a variety of products except asphalt or similar for which the parabolic antenna is
recommended
■ Custody transfer accuracy according to OIML R85:2008
■ Certified SIL 2 and SIL 3 capable according to IEC 61508
■ 2-in-1 functionality available for redundant level measurement
■ Communicates via a 2-wire, low voltage Tankbus for easy and safe installation
■ Installation normally with tank in service

VIEW PRODUCT >

Required model components


Model

Code Description
5900S Radar Level Gauge

Performance class

Code Description
P Premium: ±0.5 mm (0.020 in.) instrument accuracy

Safety certification (SIS)

Code Description
3(1) Certified IEC 61508 SIL 3 capable
S(2) Certified IEC 61508 SIL 2 capable
F None. Ready for upgrade to Safety certification (SIS)
0 None
(1) Requires Redundancy code 2 and Rosemount 2410 with Safety certification (SIS) code 3.
(2) Requires Rosemount 2410 with either Analog output 4-20 mA or Relay output code 1 or 2.

Redundancy

Code Description
2 2-in-1: Dual independent radar level gauge electronics
F None. Ready for upgrade to 2-in-1
1 None. Single radar level gauge electronics

12 Emerson.com/Rosemount
November 2021 Rosemount 5900S

Tankbus: Power and communication

Code Description
F Bus powered 2-wire FOUNDATION™ Fieldbus (IEC 61158)

Hazardous location certification

Code Description
I1 ATEX Intrinsic Safety
I7 IECEx Intrinsic Safety
I5 FM-US Intrinsic Safety
I6 FM-Canada Intrinsic Safety
I2 INMETRO Intrinsic Safety (Brazil)
IP(1) KC Intrinsic Safety (South Korea)
IW CCOE/PESO Intrinsic Safety (India)
I4(2) Japan Intrinsic Safety
IM Technical Regulations Customs Union (EAC) Intrinsic Safety
NA None
(1) Requires Custody transfer type approval code R or 0.
(2) Not available with Cable entry/Conduit connections code E or M.

Custody transfer type approval


Requires the same Custody transfer type approval code for both the Rosemount 2410 and the Rosemount 5900S.

Code Description
R(1)(2) OIML R85 edition 2008
A(1)(2) CMI (Czech Republic)
B(1)(2) NMI (Australia)
C(2)(3) PTB Eich (Germany)
E(1)(2) TJA (Estonia)
G(1)(2) GUM (Poland)
I(1)(4) Ministero (Italy)
K(1)(2)(5) GOST (Kazakhstan)
L(4)(6) LNE (France)
M(1)(4) BMS (Belgium)
N(4)(7) NMi (The Netherlands)
O(1)(2) ONML (Algeria)
Q(1)(2) IPQ (Portugal)
S(1)(2)(5) GOST (Russia)
T(1)(2) ANM (Tunisia)
W(1)(2) METAS (Switzerland)

Emerson.com/Rosemount 13
Rosemount 5900S November 2021

Code Description
Y(1)(2) Justervesenet (Norway)
0 None
(1) Requires integral display in Rosemount 2410 or Rosemount 2230 or Rosemount TankMaster.
(2) Requires Calibration certificate options code Q4.
(3) Requires integral display in Rosemount 2410 or Rosemount 2230 with Custody transfer approval code C or Rosemount TankMaster.
(4) Requires Calibration certificate options code S4.
(5) Requires Hazardous location certification code I1.
(6) Requires integral display in Rosemount 2410 or Rosemount 2230 with Custody transfer approval code L or Rosemount TankMaster.
(7) Requires integral display in Rosemount 2410 or Rosemount 2230 with Custody transfer approval code N or Rosemount TankMaster.

Level measurement method

Code Description
1 10 GHz FMCW radar technology
2 10 GHz FMCW radar technology for US/Russian installation

Housing

Code Description
A Standard enclosure, polyurethane-covered aluminum. IP 66/67

Cable entry/Conduit connections

Code Description
1 ½ - 14 NPT, female thread. (1 plug included)
2 M20 x 1.5 adapters, female thread. (2 adapters and 1 plug included)
G Metal cable glands (½ - 14 NPT). Minimum temperature -20 °C (-4 °F). ATEX/IECEx Exe approved.
(2 glands and 1 plug included)
E eurofast® male connector (1 plug included)
M minifast® male connector (1 plug included)

Antenna

Code Description
1H Horn antenna

Antenna size

Code Description
8 8 in. / DN 200, Ø=175 mm (6.9 in.)

Antenna material

Code Description
S SST AISI 316/316L and SST EN 1.4401/1.4404

14 Emerson.com/Rosemount
November 2021 Rosemount 5900S

Tank seal

Code Description
PV PTFE with Viton® fluoroelastomer O-ring

Tank connection

Code Description
ANSI Hole Pattern (SST AISI 316/316 L) – Flat Face
8A 8 in. Class 150
8Z 8 in. Class 150, inclined 4 degrees
EN Hole Pattern (SST EN 1.4401/1.4404) – Flat Face
LA DN 200/PN 10
LZ DN 200/PN 10, inclined 4 degrees

Antenna options

Code Description
0 None

Additional options
Safety certificate
Requires Safety certification (SIS) code 3 or S.

Code Description
QT IEC 61508 certificate and FMEDA-data (printed copy)

Calibration certificate

Code Description
Q4 Calibration certificate (printed copy)
S4 Witnessed calibration certificate (witnessed by factory selected accredited third party)

Material traceability certificate


Not available for transmitter head sparepart.

Code Description
Q8 Antenna material traceability certification per EN 10204 3.1

Emerson.com/Rosemount 15
Rosemount 5900S November 2021

Overfill protection approval

Code Description
U1(1) TÜV/DIBt WHG approval for overfill protection
U2 SVTI approval for overfill protection (Switzerland)
(1) Requires one or more relay outputs in the Rosemount 2410 Tank Hub.

Tag plate

Code Description
ST Engraved SST tag plate (tag shall be submitted with order)

Extended product warranty


Rosemount extended warranties have a limited warranty of three or five years from date of shipment.

Code Description
WR3 3-year limited warranty
WR5 5-year limited warranty

16 Emerson.com/Rosemount
November 2021 Rosemount 5900S

Rosemount 5900S Radar Level Gauge with still-pipe array antenna


The Rosemount 5900S with array antenna is a premium non-contact radar level gauge for
still-pipe measurement. It is available in two versions, fixed and hinged hatch. Typical
applications are crude oil tanks with floating roofs and gasoline/product tanks with or
without inner floating roofs.
■ Suitable for crude oil, gasoline or similar products. For Methanol please consult factory.
■ Custody transfer accuracy according to OIML R85:2008
■ Certified SIL 2 and SIL 3 capable according to IEC 61508
■ 2-in-1 functionality available for redundant level measurement
■ Tolerant against rust and product deposits inside the pipe, using Low Loss mode
■ Communicates via a 2-wire, low voltage Tankbus for easy and safe installation
■ Hinged hatch version enables easier product sampling and hand-dips
■ Installation normally with tank in service

VIEW PRODUCT >

Required model components


Model

Code Description
5900S Radar Level Gauge

Performance class

Code Description
P Premium: ±0.5 mm (0.020 in.) instrument accuracy

Safety certification (SIS)

Code Description
3(1) Certified IEC 61508 SIL 3 capable
S(2) Certified IEC 61508 SIL 2 capable
F None. Ready for upgrade to Safety certification (SIS)
0 None
(1) Requires Redundancy code 2 and Rosemount 2410 with Safety certification (SIS) code 3.
(2) Requires Rosemount 2410 with either Analog output 4-20 mA or Relay output code 1 or 2.

Redundancy

Code Description
2 2-in-1: Dual independent radar level gauge electronics
F None. Ready for upgrade to 2-in-1
1 None. Single radar level gauge electronics

Emerson.com/Rosemount 17
Rosemount 5900S November 2021

Tankbus: Power and communication

Code Description
F Bus powered 2-wire FOUNDATION™ Fieldbus (IEC 61158)

Hazardous location certification

Code Description
I1 ATEX Intrinsic Safety
I7 IECEx Intrinsic Safety
I5 FM-US Intrinsic Safety
I6 FM-Canada Intrinsic Safety
I2 INMETRO Intrinsic Safety (Brazil)
IP(1) KC Intrinsic Safety (South Korea)
IW CCOE/PESO Intrinsic Safety (India)
I4(2) Japan Intrinsic Safety
IM Technical Regulations Customs Union (EAC) Intrinsic Safety
NA None
(1) Requires Custody transfer type approval code R or 0.
(2) Not available with Cable entry/Conduit connections code E or M.

Custody transfer type approval


Requires the same Custody transfer type approval code for both the Rosemount 2410 and the Rosemount 5900S.

Code Description
R(1)(2) OIML R85 edition 2008
A(1)(3) CMI (Czech Republic)
B(1)(3) NMI (Australia)
C(3)(4) PTB Eich (Germany)
E(1)(3) TJA (Estonia)
G(1)(3) GUM (Poland)
I(1)(5) Ministero (Italy)
K(1)(3)(6) GOST (Kazakhstan)
L(5)(7) LNE (France)
M(1)(5) BMS (Belgium)
N(8)(9) NMi (The Netherlands)
O(1)(3) ONML (Algeria)
Q(1)(3) IPQ (Portugal)
S(1)(2)(6) GOST (Russia)
T(1)(3) ANM (Tunisia)
W(1)(3) METAS (Switzerland)

18 Emerson.com/Rosemount
November 2021 Rosemount 5900S

Code Description
Y(1)(3) Justervesenet (Norway)
0 None
(1) Requires integral display in Rosemount 2410 or Rosemount 2230 or Rosemount TankMaster.
(2) Requires Calibration certificate options code Q4 or QL.
(3) Requires Calibration certificate options code Q4.
(4) Requires integral display in Rosemount 2410 or Rosemount 2230 with Custody transfer approval code C or Rosemount TankMaster.
(5) Requires Calibration certificate options code S4.
(6) Requires Hazardous location certification code I1.
(7) Requires integral display in Rosemount 2410 or Rosemount 2230 with Custody transfer approval code L or Rosemount TankMaster.
(8) Requires integral display in Rosemount 2410 or Rosemount 2230 with Custody transfer approval code N or Rosemount TankMaster.
(9) Requires Calibration certificate options code S4 or SL.

Level measurement method

Code Description
1 10 GHz FMCW radar technology
2 10 GHz FMCW radar technology for US/Russian installation

Housing

Code Description
A Standard enclosure, polyurethane-covered aluminum. IP 66/67

Cable entry/Conduit connections

Code Description
1 ½ - 14 NPT, female thread. (1 plug included)
2 M20 x 1.5 adapters, female thread. (2 adapters and 1 plug included)
G Metal cable glands (½ - 14 NPT). Minimum temperature -20 °C (-4 °F). ATEX/IECEx Exe approved.
(2 glands and 1 plug included)
E eurofast® male connector (1 plug included)
M minifast® male connector (1 plug included)

Antenna

Code Description
1A Still-pipe array antenna

Antenna size

Code Description
5 5 in./DN 125, Ø=120 mm (4.7 in.)
6 6 in./DN 150, Ø=145 mm (5.7 in.)

Emerson.com/Rosemount 19
Rosemount 5900S November 2021

Code Description
8 8 in./DN 200, Ø=189 mm (7.4 in.)
A 10 in./DN 250, Ø=243 mm (9.8 in.)
B 12 in./DN 300, Ø=293 mm (11.8 in.)

Antenna material

Code Description
S SST (AISI 316L / EN 1.4404) and PPS (polyphenylene sulfide)

Tank seal

Code Description
FF Fixed flange installation with fluorosilicone O-ring
HH Integrated hatch installation with fluorosilicone O-ring (direct access to pipe with hand gauge)

Tank connection

Code Description
ANSI Hole Pattern (SST AISI 316/316 L) – Flat Face
5A 5 in. Class 150
6A 6 in. Class 150
8A 8 in. Class 150
AA 10 in. Class 150
BA 12 in. Class 150
EN Hole Pattern (SST EN 1.4404) – Flat Face
KA DN 150 PN 16
LA DN 200 PN 10
MB DN 250 PN 16

Antenna options

Code Description
0 None
C Clamp flange in galvanized steel (for still-pipes without a flange). Available for 6, 8 , 10, and 12 in. tank connections.
V(1)(2)(3) Proof test verification reflector (size equal to Tank connection)
(1) Requires Antenna size code 6, 8, A, or B.
(2) Not available with Options code U1.
(3) Requires Custody transfer type approval code 0 or R.

20 Emerson.com/Rosemount
November 2021 Rosemount 5900S

Additional options
Safety certificate
Requires Safety certification (SIS) code 3 or S.

Code Description
QT IEC 61508 certificate and FMEDA-data (printed copy)

Calibration certificate

Code Description
Q4 Calibration certificate (tank height up to 30 m (100 ft), printed copy)
QL Calibration certificate 40 m (tank height up to 40 m (130 ft), printed copy)
S4 Witnessed calibration certificate (tank height up to 30 m (100 ft), witnessed by factory selected accredited third
party)
SL Witnessed calibration certificate 40 m (witnessed by factory selected accredited third party)

Material traceability certificate


Not available for transmitter head sparepart.

Code Description
Q8 Antenna material traceability certification per EN 10204 3.1

Overfill protection approval

Code Description
U1(1) TÜV/DIBt WHG approval for overfill protection
U2 SVTI approval for overfill protection (Switzerland)
(1) Requires one or more relay outputs in the Rosemount 2410 Tank Hub.

Tag plate

Code Description
ST Engraved SST tag plate (tag shall be submitted with order)

Extended product warranty


Rosemount extended warranties have a limited warranty of three or five years from date of shipment.

Code Description
WR3 3-year limited warranty
WR5 5-year limited warranty

Emerson.com/Rosemount 21
Rosemount 5900S November 2021

Rosemount 5900S Radar Level Gauge with LPG/LNG antenna


The Rosemount 5900S with LPG/LNG antenna is a premium non-contact radar level gauge for
measurement on pressurized or cryogenic liquefied gas. Radar signals are transmitted inside the still-pipe
which enables the gauge to have a sufficiently strong echo even under turbulent conditions, such as a
boiling surface.
■ Custody transfer accuracy according to OIML R85:2008
■ Certified SIL 2 and SIL 3 capable according to IEC 61508
■ 2-in-1 functionality available for redundant level measurement
■ Reference device function enables measurement verification with the tank in service
■ Communicates via a 2-wire, low voltage Tankbus for easy and safe installation
■ Built-in pressure sensor for vapor compensation gives best measurement performance
■ Integrated ball valve

VIEW PRODUCT >

Required model components


Model

Code Description
5900S Radar Level Gauge

Performance class

Code Description
P Premium: ±0.5 mm (0.020 in.) instrument accuracy

Safety certification (SIS)

Code Description
3(1) Certified IEC 61508 SIL 3 capable
S(2) Certified IEC 61508 SIL 2 capable
F None. Ready for upgrade to Safety certification (SIS)
0 None
(1) Requires Redundancy code 2 and Rosemount 2410 with Safety certification (SIS) code 3.
(2) Requires Rosemount 2410 with either Analog output 4-20 mA or Relay output code 1 or 2.

22 Emerson.com/Rosemount
November 2021 Rosemount 5900S

Redundancy

Code Description
2 2-in-1: Dual independent radar level gauge electronics
F None. Ready for upgrade to 2-in-1
1 None. Single radar level gauge electronics

Tankbus: Power and communication

Code Description
F Bus powered 2-wire FOUNDATION™ Fieldbus (IEC 61158)

Hazardous location certification

Code Description
I1 ATEX Intrinsic Safety
I7 IECEx Intrinsic Safety
I5 FM-US Intrinsic Safety
I6 FM-Canada Intrinsic Safety
I2 INMETRO Intrinsic Safety (Brazil)
IP(1) KC Intrinsic Safety (South Korea)
IW CCOE/PESO Intrinsic Safety (India)
I4(2) Japan Intrinsic Safety
IM Technical Regulations Customs Union (EAC) Intrinsic Safety
NA None
(1) Requires Custody transfer type approval code R or 0.
(2) Not available with Cable entry/Conduit connections code E or M.

Custody transfer type approval


Requires the same Custody transfer type approval code for both the Rosemount 2410 and the Rosemount 5900S.

Code Description
R(1)(2) OIML R85 edition 2008
A(1)(3) CMI (Czech Republic)
B(1)(3) NMI (Australia)
C(3)(4) PTB Eich (Germany)
E(1)(3) TJA (Estonia)
G(1)(3) GUM (Poland)
I(1)(5) Ministero (Italy)
K(1)(3)(6) GOST (Kazakhstan)
L(5)(7) LNE (France)
M(1)(5) BMS (Belgium)

Emerson.com/Rosemount 23
Rosemount 5900S November 2021

Code Description
N(8)(9) NMi (The Netherlands)
O(1)(3) ONML (Algeria)
Q(1)(3) IPQ (Portugal)
S(1)(2)(6) GOST (Russia)
T(1)(3) ANM (Tunisia)
W(1)(3) METAS (Switzerland)
Y(1)(3) Justervesenet (Norway)
0 None
(1) Requires integral display in Rosemount 2410 or Rosemount 2230 or Rosemount TankMaster.
(2) Requires Calibration certificate options code Q4 or QL.
(3) Requires Calibration certificate options code Q4.
(4) Requires integral display in Rosemount 2410 or Rosemount 2230 with Custody transfer approval code C or Rosemount TankMaster.
(5) Requires Calibration certificate options code S4.
(6) Requires Hazardous location certification code I1.
(7) Requires integral display in Rosemount 2410 or Rosemount 2230 with Custody transfer approval code L or Rosemount TankMaster.
(8) Requires integral display in Rosemount 2410 or Rosemount 2230 with Custody transfer approval code N or Rosemount TankMaster.
(9) Requires Calibration certificate options code S4 or SL.

Level measurement method

Code Description
1 10 GHz FMCW radar technology
2 10 GHz FMCW radar technology for US/Russian installation

Housing

Code Description
A Standard enclosure, polyurethane-covered aluminum. IP 66/67

Cable entry/Conduit connections

Code Description
1 ½ - 14 NPT, female thread. (1 plug included)
2 M20 x 1.5 adapters, female thread. (2 adapters and 1 plug included)
G Metal cable glands (½ - 14 NPT). Minimum temperature -20 °C (-4 °F). ATEX/IECEx Exe approved.
(2 glands and 1 plug included)
E eurofast® male connector (1 plug included)
M minifast® male connector (1 plug included)

24 Emerson.com/Rosemount
November 2021 Rosemount 5900S

Antenna

Code Description
G1 LPG/LNG (liquefied gas) still-pipe antenna (with integrated ball-valve, without pressure transmitter)
G2(1) LPG/LNG (liquefied gas) still-pipe antenna (with integrated ball-valve and pressure transmitter)
G4(1)(2) LPG/LNG (liquefied gas) still-pipe antenna (with integrated ball-valve and dual pressure transmitters)
(1) Requires Hazardous location certification code I1, I2, I5, I6, I7, IP, I4, or IM.
(2) Requires Redundancy code 2.

Related information
Rosemount 5900S with LPG/LNG antenna

Antenna size

Code Description
A 4 in. Schedule 10, Ø=107 mm (4.2 in.)
B 4 in. Schedule 40, Ø=101 mm (4.0 in.)
D DN 100, Ø=99 mm (3.9 in.)

Antenna material

Code Description
S SST AISI 316/316L and SST EN1.4401/1.4404

Tank seal

Code Description
PT PTFE sealing

Tank connection

Code Description
ANSI Flanges (SST AISI 316/316 L) – Raised Face
1B(1)(2)(3) 1.5 in. Class 300
2A(1)(2)(3) 2 in. Class 150
2B(1)(2)(3) 2 in. Class 300
3A(1)(2)(3) 3 in. Class 150
3B(1)(2)(3) 3 in. Class 300
4A 4 in. Class 150
4B 4 in. Class 300
6A 6 in. Class 150
6B 6 in. Class 300
8A 8 in. Class 150
8B 8 in. Class 300

Emerson.com/Rosemount 25
Rosemount 5900S November 2021

Code Description
EN Hole Pattern (SST EN 1.4404 ) – Raised Face B1
NA DN 100 PN40
OA DN 150 PN40
PA DN 200 PN25
PB DN 200 PN40
(1) Requires Antenna size code A.
(2) Requires Custody transfer type approval code R or 0.
(3) Not available with Safety certification (SIS) code 3.

Antenna options

Code Description
V Measurement verification kit with 1 verification pin and 1 pipe end deflector kit

Additional options
Safety certificate
Requires Safety certification (SIS) code 3 or S.

Code Description
QT IEC 61508 certificate and FMEDA-data (printed copy)

Calibration certificate

Code Description
Q4 Calibration certificate (tank height up to 30 m (100 ft), printed copy)
QL Calibration certificate 40 m (tank height up to 40 m (130 ft), printed copy)
S4 Witnessed calibration certificate (tank height up to 30 m (100 ft), witnessed by factory selected accredited third
party)
SL Witnessed calibration certificate 40 m (witnessed by factory selected accredited third party)

Material traceability certificate


Not available for transmitter head sparepart.

Code Description
Q8 Antenna material traceability certification per EN 10204 3.1

Overfill protection approval

Code Description
U1(1) TÜV/DIBt WHG approval for overfill protection
U2 SVTI approval for overfill protection (Switzerland)
(1) Requires one or more relay outputs in the Rosemount 2410 Tank Hub.

26 Emerson.com/Rosemount
November 2021 Rosemount 5900S

Tag plate

Code Description
ST Engraved SST tag plate (tag shall be submitted with order)

Hydrostatic pressure test

Code Description
P1 Antenna hydrostatic pressure testing

Extended product warranty


Rosemount extended warranties have a limited warranty of three or five years from date of shipment.

Code Description
WR3 3-year limited warranty
WR5 5-year limited warranty

Emerson.com/Rosemount 27
Rosemount 5900S November 2021

Specifications
General

Instrument accuracy
Rosemount 5900S standard version ± 0.5 mm (0.020 in.)
Rosemount 5900S 2-in-1 version ± 0.5 mm (0.020 in.)(1)

Instrument accuracy is under reference conditions. Reference conditions are: Measurement in test bench at Rosemount Tank Radar
AB in Mölnlycke Sweden. Test bench is calibrated minimum yearly by an accredited laboratory: RISE Research Institutes of Sweden.
Measuring range is up to 40 m (130 ft). Ambient temperature and humidity is close to constant during tests. Total uncertainty in
test bench is below 0.15 mm (0.006 in.).

Temperature stability
Typically < ± 0.5 mm (0.020 in.) in -40 to +70 °C (-40 to +158 °F)

Fieldbus (standard)
FOUNDATION™ Fieldbus FISCO (Tankbus)

Update time
New measurement every 0.3 s

Repeatability
0.2 mm (0.008 in.)

Maximum level rate


Up to 200 mm/s

Metrology sealing possibility


Yes

Installation considerations
See Rosemount 5900S Reference Manual

Measurement principle
The FMCW-method (Frequency Modulated Continuous Wave) means that the transmitted radar signal has a linear frequency
variation around 10 GHz. The reflection from the liquid surface has a slightly different frequency compared with the signal
transmitted from the antenna when the reflection is received. The difference in frequency is directly proportional to the distance
between the antenna and the liquid surface, and thereby also the liquid level. This technology enables a very accurate and stable
measured value.

(1) Some level offset may be expected on the secondary unit.

28 Emerson.com/Rosemount
November 2021 Rosemount 5900S

Figure 4: Principle of FMCW Technology


$

A. Frequency, f (GHz)
B. Time, t (s)

Communication/Display/Configuration

Output variables and units


■ Level, and ullage: meter, centimeter, millimeter, feet, or inch
■ Level rate: meter/second, meter/hour, feet/second, feet/hour, inch/minute
■ Signal strength: mV

Configuration tools
Rosemount TankMaster WinSetup, Field Communicator

Emerson.com/Rosemount 29
Rosemount 5900S November 2021


FOUNDATION Fieldbus characteristics
Polarity sensitive
No

Quiescent current draw


51 mA

Lift-off minimum voltage


9.0 VDC

Device capacitance/inductance
See Product certifications.

Class (Basic or Link Master)


Link Master (LAS)

Number of available VCRs


Maximum 20, including one fixed

Links
Maximum 40

Minimum slot time/maximum response delay/minimum intermessage delay


8/5/8

Blocks and Execution time


Table 1: Execution Time

Block Execution time


1 Resource block N/A
5 Transducer blocks (Level, Register, Adv_Config, Volume, and LPG) N/A
6 Analog Input (AI) 10 ms
2 Analog Output (AO) 10 ms
1 Proportional/Integral/Derivate (PID) 15 ms
1 Signal Characterizer (SGCR) 10 ms
1 Integrator (INT) 10 ms
1 Arithmetic (ARTH) 10 ms
1 Input Selector (ISEL) 10 ms
1 Control Selector (CS) 10 ms
1 Output Splitter (OS) 10 ms

For more information, see the FOUNDATION Fieldbus Blocks Manual.

Instantiation
Yes

Conforming FOUNDATION Fieldbus


ITK 6

30 Emerson.com/Rosemount
November 2021 Rosemount 5900S

Field Diagnostics support


Yes

Action support wizards


Restart measurement, write protect device, factory reset - measurement configuration, start/stop device simulation, set as surface,
reset statistics, change all modes, register/remove false echo, refresh echo peaks, pin verification, change vapor pressure, change
vapor temperature.

Advanced diagnostics
Software, memory/database, electronics, internal communication, simulation, level correction, level measurement, ambient
temperature, vapor pressure/temperature correction, LPG verification pin, and manual measurement values.

Emerson.com/Rosemount 31
Rosemount 5900S November 2021

Electric

Tankbus cabling
0.5-1.5 mm2 (AWG 22-16), twisted shielded pairs

Power supply
FISCO: 9.0 - 17.5 VDC polarity insensitive (for example from Rosemount 2410 Tank Hub)
Entity: 9.0 - 30.0 VDC polarity insensitive

Bus current draw


50 mA (100 mA for the 2-in-1 version)

Microwave output power


< 1 mW

Built-in Tankbus terminator


Yes (to be connected if required)

Daisy chain possibility


Yes

32 Emerson.com/Rosemount
November 2021 Rosemount 5900S

Mechanical

Housing material & surface treatment


Polyurethane-coated die-cast aluminum

Cable entry (connection/glands)


Two ½ - 14 NPT entries for cable glands or conduits. One metal plug to seal any unused port is enclosed in the transmitter delivery.
Optional:
■ M20 x 1.5 conduit/cable adapter
■ Cable glands in metal (½ - 14 NPT)
■ 4-pin male eurofast connector or A size Mini 4-pin male minifast connector

Total weight
Table 2: Weight of Transmitter Head

Transmitter head Weight


Rosemount 5900S single version 5.1 kg (11.2 lbs)
Rosemount 5900S 2-in-1 version 5.4 kg (11.9 lbs)

Table 3: Weight With Antenna

Transmitter head with antenna Weight


Rosemount 5900S with horn antenna Appr. 12 kg (26 lbs)
Rosemount 5900S with parabolic antenna Appr. 17 kg (37 lbs)
Rosemount 5900S with still-pipe array antenna Appr. 13.5-24 kg (30-53 lbs)
Rosemount 5900S with LPG/LNG antenna, 6-in. 150 psi Appr. 30 kg (66 lbs)
Rosemount 5900S with LPG/LNG antenna, 6-in. 300 psi Appr. 40 kg (88 lbs)

Antennas
The Rosemount 5900S antennas have a drip-off design which for some versions also include inclined polished PTFE surfaces.
Condensation on the antenna is minimized, and the radar signal remains strong. This results in maintenance free operation, high
accuracy and reliability. There is always a suitable antenna for every tank type, tank opening and application:
■ Parabolic
■ Horn
■ Still-pipe array
■ LPG/LNG

Emerson.com/Rosemount 33
Rosemount 5900S November 2021

Transmitter head
The same transmitter head is used for all Rosemount 5900S antenna types, minimizing spare part requirements:
■ The dual compartment transmitter housing, with electronics and cabling separated, can be replaced without opening the tank
■ It is protected against lightning, moisture/rain, and has a surface protection against sulphur and salt spray atmospheres
■ Electronics consists of one or two encapsulated units. The 2-in-1 solution has duplicate, galvanically isolated electronic units in
the same housing
■ No need for re-calibration

34 Emerson.com/Rosemount
November 2021 Rosemount 5900S

Environment

Ambient operating temperature


-40 to +70 °C (-40 to +158 °F). Minimum start-up temperature is -50 °C (-58 °F)

Storage temperature
-50 to +85 °C (-58 to +185 °F)

Humidity
0-100% relative humidity

Ingress protection
IP 66/67 and NEMA® 4X

Vibration resistance
IEC 60770-1 level 1 and IACS UR E10 test 7

Telecommunication
Compliance with:
■ FCC 15B Class A, and 15C
■ RED (EU directive 2014/53/EU) ETSI EN 302372; EN 50371
■ IC (RSS210-5)

Electromagnetic compatibility
■ EMC (EU directive 2014/30/EU) EN 61326-1; EN 61326-3-1
■ OIML R85:2008

Transient / built-in lightning protection


According to IEC 61000-4-5, level 2 kV line to ground. Complies with IEEE 587 Category B transient protection and IEEE 472 surge
protection.

Low Voltage Directive (LVD)


LVD (EU directive 2014/35/EU) EN/IEC 61010-1

Emerson.com/Rosemount 35
Rosemount 5900S November 2021

Rosemount 5900S SIL 2 version (SIS option code S)

Rosemount 5900S 2-in-1 version


Separation
Galvanically separated gauge electronics, and shared antenna for the two units

Wiring
Separated or common

Tank hub connection


■ Connection of both units to one hub, or
■ Separate connection of units to two different hubs

Built-in Tankbus terminator


Single Tankbus connection: Yes (to be connected if required).
Dual Tankbus connection: Possible to terminate the primary Tankbus.

Daisy chain possibility


Yes

Rosemount 5900S SIL 3 version (SIS option code 3)


Measuring range
1.2 to 30 m (3.9 to 100 ft) below flange.

Separation
Galvanically separated gauge electronics, and shared antenna

Built-in Tankbus terminator


No

Daisy chain possibility


Yes

Electric properties for intrinsically safe alarm signal


12.5 VDC, 1-2 mA for normal condition (no alarm)

Wiring
■ Additional separate 2-wire cable for alarm or
■ A single cable incorporating two 2-wire cables (alarm and level)

For cable specification, see Cable entry (connection/glands)

36 Emerson.com/Rosemount
November 2021 Rosemount 5900S

Rosemount 5900S with parabolic antenna


Operating temperature in tank
Maximum +180 °C (+356 °F) with FEP O-ring, or +230 °C (+445 °F) with Kalrez® O-ring

Measuring range
0.8 to 40 m (2.6 to 130 ft) below flange(2)
Possibility to measure 0.5 to 50 m (1.6 to 164 ft). Accuracy may be reduced. For longer measuring range, consult your local
representative.

Pressure range
Clamped/threaded: -0.2 to 0.2 bar (-2.9 to 2.9 psig)
Welded: -0.2 to 10 bar (-2.9 to 145 psig)

Material exposed to tank atmosphere


Antenna: Material corresponds to AISI 316/316L and EN 1.4401 /1.4404
Sealing: PTFE
O-ring: FEP, or Kalrez®

Antenna dimension
440 mm (17 in.)

Manway size and installation


500 mm (20-in.) opening.
The parabolic antenna is installed on the manway cover by using the flange ball. It is designed for easy adjustment of the antenna
inclination and orientation within the specified limits.
The flexible flange ball can be installed on both horizontal or inclined manways without any special arrangements.

(2) Local regulations and applicable certificates must be observed.

Emerson.com/Rosemount 37
Rosemount 5900S November 2021

Rosemount 5900S with horn antenna


Operating temperature in tank
Maximum +180 °C (+356 °F)

Measuring range
0.8 to 20 m (2.6 to 65 ft) below flange.
Possibility to measure 0.5 to 30 m (1.6 to 100 ft). Accuracy may be reduced. For longer measuring range, consult your local
representative.

Pressure range
-0.2 to 2 bar (-2.9 to 29 psig)

Material exposed to tank atmosphere


Antenna and flange: Material corresponds to AISI 316/316L and EN 1.4401 /1.4404
Sealing: PTFE
O-ring: Viton®

Antenna dimension
175 mm (7 in.)

Nozzle diameter
Minimum 200 mm (8 in.)

Tank connection
The flange can be horizontal or 4° inclined for installation close to the tank wall.
The horizontal flange is used when highest accuracy and reliability is required. The 4° inclined version can be used to maintain high
accuracy when the gauge is installed close to the tank wall.

38 Emerson.com/Rosemount
November 2021 Rosemount 5900S

Rosemount 5900S with still-pipe array antenna


Operating temperature in tank
-40 to 120 °C (-40 to 248 °F)

Measuring range
0.8 to 40 m (2.6 to 130 ft) below flange(3)
The minimum range can be extended to 0.5 m (1.6 ft) with slightly reduced accuracy. For longer measuring range, consult your
local representative.

Pressure range
Fixed version: -0.2 to 2 bar (-2.9 to 29 psig) at 20 °C (68 °F).
Hinged hatch version: -0.2 to 0.5 bar (-2.9 to 7.2 psig) for 5 to 8-in. pipes.
-0.2 to 0.25 bar (-2.9 to 3.6 psig) for 10 and 12-in. pipes.

Material exposed to tank atmosphere


Antenna: Polyphenylenesulphide (PPS)
Sealing: PTFE
O-ring: FMVQ
Flange: Material corresponds to AISI 316/316L and EN 1.4401 /1.4404

Still-pipe dimensions
5-, 6-, 8-, 10- or 12 in.

Tank connection
5 in. hole pattern according to ANSI 5 in. Class 150
6 in. hole pattern according to ANSI 6 in. Class 150 / DN 150 PN 16
8 in. hole pattern according to ANSI 8 in. Class 150 / DN 200 PN 10
10 in. hole pattern according to ANSI 10 in. Class 150 / DN 250 PN 16
12 in. hole pattern according to ANSI 12 in. Class 150

Low Loss Mode


To get the accuracy, required for custody transfer bulk liquid storage applications, the antenna uses Low Loss Mode technology,
invented for Rosemount Tank Gauging products, to transmit radar waves in the still-pipe center.
This virtually eliminates signal and accuracy degradation due to rust and product deposits inside the still-pipe.

(3) Local regulations and applicable certificates must be observed.

Emerson.com/Rosemount 39
Rosemount 5900S November 2021

Rosemount 5900S with LPG/LNG antenna


Operating temperature at ball valve
-55 to 90 °C (-67 to 194 °F)

Operating temperature in tank


-170 to 90 °C (-274 to 194 °F)

Measuring range
1.2 to 40 m (3.9 to 130 ft) below flange(4)
Possibility to measure 0.8 to 60 m (2.6 to 200 ft). Accuracy may be reduced. For longer measuring range, consult your local
representative.

Pressure range
-1 to 25 bar (-14.5 to 365 psig).
Note! Flanges may have higher pressure rating than 25 bar, but maximum tank pressure is still 25 bar.

Pressure sensor (option)


Rosemount 2051, pressure sensor range 0-55 bar. For other pressure range contact factory. Rosemount 2051 is available with
various hazardous location certifications, see Product certifications.
For more information see the Rosemount 2051 Product Data Sheet.

Material exposed to tank atmosphere


Antenna and flange: Material corresponds to AISI 316/316L and EN 1.4401 /1.4404
Sealing: PTFE

Still-pipe dimension compatibility


Antenna choices for 4-in. sch. 10, 4-in. sch 40, or 100 mm (99 mm inner diameter) still-pipe dimensions

Flange size and rating


1.5 in. Class 300
2 in. Class 150/300
3 in. Class 150/300
4 in. Class 150/300
6 in. Class 150/300
8 in. Class 150/300
DN 100 PN40
DN 150 PN40
DN 200 PN25
DN 200 PN40

Pressure seal
The pressure seal includes a double-block function, consisting of a PTFE seal and a fire-proof ball valve. A pressure sensor enables
correction due to vapor for best measurement performance.

(4) Local regulations and applicable certificates must be observed.

40 Emerson.com/Rosemount
November 2021 Rosemount 5900S

Verification possibility
A patented reference device function enables measurement verification with the tank in service. A verification pin mounted in a
still-pipe hole, and a deflection plate with a verification ring at the lower still-pipe end provide reference echoes at fixed pre-defined
distances.

Emerson.com/Rosemount 41
Rosemount 5900S November 2021

Product certifications
Rev 7.28

European directive information


The most recent revision of the EU Declaration of Conformity can be found at Emerson.com/Rosemount.

Ordinary Location Certification


As standard, the transmitter has been examined and tested to determine that the design meets the basic electrical, mechanical,
and fire protection requirements by a nationally recognized test laboratory (NRTL) as accredited by the Federal Occupational Safety
and Health Administration (OSHA). Complies with FM 3810:2005 and CSA: C22.2 No. 1010.1.

Telecommunication compliance

FCC
This device complies with Part 15C of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not
cause interference, and (2) this device must accept any interference received, including interference that may cause undesired
operation.
Certificate: K8C5900

IC
This device complies with RSS210-7.
Certificate: 2827A-5900

Radio Equipment Directive (RED)


This device complies with ETSI EN 302 372 and EN 62479. EU directive 2014/53/EU. The device shall be installed according to
requrements ETSI EN 302372.

CE-mark
The product complies with applicable EU directives (EMC, ATEX, LVD, and RED). Based on the low emitted effects from the gauges
(below 0.1 mW) compared to limits given by the Rec. 1999/519/EC, no additional measures are needed.

Installing Equipment in North America


The US National Electrical Code® (NEC) and the Canadian Electrical Code (CEC) permit the use of Division marked equipment in
Zones and Zone marked equipment in Divisions.
The markings must be suitable for the area classification, gas, and temperature class. This information is clearly defined in the
respective codes.

42 Emerson.com/Rosemount
November 2021 Rosemount 5900S

North America

I5 USA Intrinsic Safety


Certificate FM 17US0030X
Standards FM Class 3600:2018, FM Class 3610:2018, FM Class 3810:2005, ANSI/ISA 61010-1:2004, ANSI/NEMA
250:2003, ANSI/IEC 60529:2004, ANSI/UL 60079-0:2013 Ed 6, ANSI/UL 60079-11:2014 Ed 6.3, ANSI/UL
60079-26:2017 Ed 3
Markings IS/I,II,III/1/ABCDEFG/T4
DIP/II,III/1/EFG/T5
CL 1 ZN 0 AEx ia IIC T4 Ga
CL 1 ZN 0/1 AEx ib IIC T4 Ga/Gb
Ta = -50°C to 80°C - 9240040-917;
Type 4X; IP66; IP67

Ui (Vmax) Ii (lmax) Pi Ci Li
Entity parameters 30 V 300 mA 1.3 W 1.1 nF 1.5 µH
FISCO parameters 17.5V 380 mA 5.32 W 1.1 nF 1.5 µH

Specific Conditions for Safe Use (X):


1. The enclosure contains aluminum and is considered to present a potential risk of ignition by impact or friction. When
installed as EPL Ga, care must be taken during installation and use to prevent impact or friction.
2. Non-metallic surfaces and the surface of the painted housing may, under certain extreme conditions, generate an ignition-
capable level of electrostatic. Appropriate measures must be taken to prevent electrostatic discharge.
3. Using the box provided on the nameplate, the User shall permanently mark the type of protection chosen for the specific
installation. Once the type of protection has been marked it shall not be changed.
4. When installed as Ex ib Ga/Gb, the partition wall materials separating EPL Ga from EPL Gb are constructed of different
materials depending on the antenna option. Please refer to Control Drawing D9240040-917 for the material type of each
antenna. The material shall not be subject to environmental conditions which might adversely affect the partition wall.
5. Maximum Process Temperatures are as follows:

When option n=Tank Seal O-ring Type Min/Max Process Temperature Range
PV or QV Viton -15°C to +180°C
PK, FK, HK or QK Kalrez -20°C to +230°C
PE or QE EPDM -40°C to +110°C
PB or QB BUNA-N -35°C to +90°C
PM, FF, HH or QM FVMQ -60°C to +155°C
PF or QF FEP -60°C to +180°C

Emerson.com/Rosemount 43
Rosemount 5900S November 2021

I6 Canada Intrinsic Safety


Certificate FM17CA0016X
Standards CSA-C22.2 No. 25-2017
CSA-C22.2 No. 94-M91:1991 (R2011)
CSA-C22.2 No. 1010-1:2004 (R2009)
CSA-C22.2 No. 60529:2016
CSA-C22.2 No. 60079-0:2015
CSA-C22.2 No. 60079-11:2014
CSA-C22.2 No. 60079-26:2016
Markings IS/I,II,III/1/ABCDEFG/T4
Ex ia IIC T4 Ga
Ex ib IIC T4 Ga/Gb
DIP/II,III/1/EFG/T5
Ta = -50°C to 80°C
9240040-917
Type 4X; IP66; IP67

Ui (Vmax) Ii (lmax) Pi Ci Li
Entity parameters 30 V 300 mA 1.3 W 1.1 nF 1.5 µH
FISCO parameters 17.5V 380 mA 5.32 W 1.1 nF 1.5 µH

Specific Conditions for Safe Use (X):


1. The enclosure contains aluminum and is considered to present a potential risk of ignition by impact or friction. When
installed as EPL Ga, care must be taken during installation and use to prevent impact or friction.
2. Non-metallic surfaces and the surface of the painted housing may, under certain extreme conditions, generate an ignition-
capable level of electrostatic. Appropriate measures must be taken to prevent electrostatic discharge.
3. Using the box provided on the nameplate, the User shall permanently mark the type of protection chosen for the specific
installation. Once the type of protection has been marked it shall not be changed.
4. When installed as Ex ib Ga/Gb, the partition wall materials separating EPL Ga from EPL Gb are constructed of different
materials depending on the antenna option. Please refer to Control Drawing D9240040-917 for the material type of each
antenna. The material shall not be subject to environmental conditions which might adversely affect the partition wall.
5. Maximum Process Temperatures are as follows:

When option n=Tank Seal O-ring Type Min/Max Process Temperature Range
PV or QV Viton -15°C to +180°C
PK, FK, HK or QK Kalrez -20°C to +230°C
PE or QE EPDM -40°C to +110°C
PB or QB BUNA-N -35°C to +90°C
PM, FF, HH or QM FVMQ -60°C to +155°C
PF or QF FEP -60°C to +180°C

44 Emerson.com/Rosemount
November 2021 Rosemount 5900S

Europe

I1 ATEX Intrinsic Safety


Certificate FM09ATEX0057X
Standards EN IEC 60079-0:2018, EN 60079-11:2012, EN 60079-26:2015, EN 60529:1991+A1(2000)+A2(2013)
Markings
II 1 G Ex ia IIC T4 Ga
II 1/2 G Ex ib IIC T4 Ga/Gb
Ta = -50°C to 80°C; IP66, IP67

Ui (Vmax) Ii (lmax) Pi Ci Li
Entity parameters 30 V 300 mA 1.3 W 1.1 nF 1.5 µH
FISCO parameters 17.5V 380 mA 5.32 W 1.1 nF 1.5 µH

Specific Conditions for Safe Use (X):


1. The enclosure contains aluminum and is considered to present a potential risk of ignition by impact or friction. When
installed as EPL Ga, care must be taken during installation and use to prevent impact or friction.
2. Non-metallic surfaces and the surface of the painted housing may, under certain extreme conditions, generate an ignition-
capable level of electrostatic. Appropriate measures must be taken to prevent electrostatic discharge.
3. Using the box provided on the nameplate, the User shall permanently mark the type of protection chosen for the specific
installation. Once the type of protection has been marked it shall not be changed.
4. When installed as Ex ib Ga/Gb, the partition wall materials separating EPL Ga from EPL Gb are constructed of different
materials depending on the antenna option. Please refer to Control Drawing D9240040-917 for the material type of each
antenna. The material shall not be subject to environmental conditions which might adversely affect the partition wall.
5. Maximum Process Temperatures are as follows:

When option n=Tank Seal O-ring Type Min/Max Process Temperature Range
PV or QV Viton -15°C to +180°C
PK, FK, HK or QK Kalrez -20°C to +230°C
PE or QE EPDM -40°C to +110°C
PB or QB BUNA-N -35°C to +90°C
PM, FF, HH or QM FVMQ -60°C to +155°C
PF or QF FEP -60°C to +180°C

Emerson.com/Rosemount 45
Rosemount 5900S November 2021

International

I7 IECEx Intrinsic Safety


Certificate IECEx FMG 09.0009X
Standards IEC 60079-0:2017, IEC 60079-11:2011, IEC 60079-26:2014
Markings Ex ia IIC T4 Ga
Ex ib IIC T4 Ga/Gb
Ta = -50°C to +80°C; IP66, IP67

Ui (Vmax) Ii (lmax) Pi Ci Li
Entity parameters 30 V 300 mA 1.3 W 1.1 nF 1.5 µH
FISCO parameters 17.5V 380 mA 5.32 W 1.1 nF 1.5 µH

Specific Conditions for Safe Use (X):


1. The enclosure contains aluminum and is considered to present a potential risk of ignition by impact or friction. When
installed as EPL Ga, care must be taken during installation and use to prevent impact or friction.
2. Non-metallic surfaces and the surface of the painted housing may, under certain extreme conditions, generate an ignition-
capable level of electrostatic. Appropriate measures must be taken to prevent electrostatic discharge.
3. Using the box provided on the nameplate, the User shall permanently mark the type of protection chosen for the specific
installation. Once the type of protection has been marked it shall not be changed.
4. When installed as Ex ib Ga/Gb, the partition wall materials separating EPL Ga from EPL Gb are constructed of different
materials depending on the antenna option. Please refer to Control Drawing D9240040-917 for the material type of each
antenna. The material shall not be subject to environmental conditions which might adversely affect the partition wall.
5. Maximum Process Temperatures are as follows:

When option n=Tank Seal O-ring Type Min/Max Process Temperature Range
PV or QV Viton -15°C to +180°C
PK, FK, HK or QK Kalrez -20°C to +230°C
PE or QE EPDM -40°C to +110°C
PB or QB BUNA-N -35°C to +90°C
PM, FF, HH or QM FVMQ -60°C to +155°C
PF or QF FEP -60°C to +180°C

46 Emerson.com/Rosemount
November 2021 Rosemount 5900S

Brazil

I2 INMETRO Intrinsic Safety


Certificate UL-BR 17.0982X
Standards ABNT NBR IEC 60079-0:2020, 60079-11:2013, 60079-26:2016
Markings Ex ia IIC T4 Ga
Ex ib IIC T4 Ga/Gb
Tamb: -50 °C to + 80 °C
IP66/IP67

Ui (Vmax) Ii (lmax) Pi Ci Li
Entity parameters 30 V 300 mA 1.3 W 1.1 nF 1.5 µH
FISCO parameters 17.5V 380 mA 5.32 W 1.1 nF 1.5 µH

Special Conditions for Safe Use (X):


1. See certificate for special conditions.

China

I3 China Intrinsic Safety


Certificate GYJ21.1117X
Standards GB 3836.1 - 2010, GB 3836.4 - 2010, GB 3836.20 - 2010
Markings Ex ia IIC T4 Ga
Ex ib IIC T4 Ga/Gb

Ui (Vmax) Ii (lmax) Pi Ci Li
Entity parameters 30 V 300 mA 1.3 W 1.1 nF 1.5 µH
FISCO parameters 17.5V 380 mA 5.32 W 1.1 nF 1.5 µH

Special Conditions for Safe Use (X):


1. See certificate for special conditions.

Emerson.com/Rosemount 47
Rosemount 5900S November 2021

Technical Regulations Customs Union (EAC)


TR CU 020/2011 “Electromagnetic Compatibility of Technical Products”
TR CU 032/2013 “On safety of equipment and vessels under pressure”

Certificate ЕАЭC RU С-US.АД07.В.00770/19

IM EAC Intrinsic Safety


Certificate ЕАЭС RU C-SE.AA87.B.00528/20
Markings 0 Ex ia IIC T4 Ga X
Ga/Gb Ex ib IIC T4 X
Tamb: -50 °C to + 80 °C
IP66/IP67

Ui (Vmax) Ii (lmax) Pi Ci Li
Entity parameters 30 V 300 mA 1.3 W 1.1 nF 1.5 µH
FISCO parameters 17.5V 380 mA 5.32 W 1.1 nF 1.5 µH

Special Conditions for Safe Use (X):


1. See certificate for special conditions.

Ex
TR CU 012/2011 “On safety of equipment intended for use in explosive atmospheres”

Japan

I4 Japan Intrinsic Safety


Certificate CML 17JPN2301X
Markings Ex ia IIC T4 Ga
Ex ib IIC T4 Ga/Gb
-50 °C ≤ Ta ≤ +80 °C

Ui (Vmax) Ii (lmax) Pi Ci Li
FISCO parameters 17.5V 380 mA 5.32 W 1.1 nF 1.5 µH
Entity parameters 30 V 300 mA 1.3 W 1.1 nF 1.5 µH

Special Conditions for Safe Use (X):


1. See certificate for special conditions.

48 Emerson.com/Rosemount
November 2021 Rosemount 5900S

Republic of Korea

IP Korea Intrinsic Safety


Certificate 14-KB4BO-0573X
Markings Ex ia IIC T4 Ga
Ex ib IIC T4 Ga/Gb
(-50 °C ≤ Ta ≤ +80 °C)

Ui (Vmax) Ii (lmax) Pi Ci Li
Entity parameters 30 V 300 mA 1.3 W 1.1 nF 1.5 µH
FISCO parameters 17.5V 380 mA 5.32 W 1.1 nF 1.5 µH

Special Conditions for Safe Use (X):


1. See certificate for special conditions.

India

India Ex Certification
Certificate P463068/1

Ui (Vmax) Ii (lmax) Pi Ci Li
Entity parameters 30 V 300 mA 1.3 W 1.1 nF 1.5 µH
FISCO parameters 17.5V 380 mA 5.32 W 1.1 nF 1.5 µH

Special Conditions for Safe Use (X):


1. See certificate for special conditions.

United Arab Emirates

Intrinsic Safety
Certificate 20-11-28736/Q20-11-001012
Markings Same as IECEx (I7)

Emerson.com/Rosemount 49
Rosemount 5900S November 2021

Additional certifications

Functional Safety Certification (SIS)


3 Functional Safety

Certificate ROS 1312032 C001


SIL 3 2-in-1 (1oo2) option (SIS-relays)
Standards IEC 61508:2010 Parts 1-7

S Functional Safety

Certificate ROS 1312032 C004


SIL 2 1-in-1 (1oo1) option, with 4-20mA or K1/K2 relay
Standards IEC 61508:2010 Parts 1-7
Certificate ROS 1312032 C005
SIL 2 2-in-1 (1oo1) option, with 4-20mA or K1/K2 relay
Standards IEC 61508:2010 Parts 1-7

Germany WHG Certification (DIBt)


Certificate Z-65.16-500

Belgium Overfill Certification (Vlarem)


Certificate 99/H031/13072201

50 Emerson.com/Rosemount
November 2021 Rosemount 5900S

Custody Transfer Certifications


Australia Custody Transfer

Certificate No 5/1/7
Standards Regulation 60: National Measurement Regulations 1999

Belgium Custody Transfer

BMS Certificate NR. P6.0.014.02-B-16

Bulgaria Custody Transfer

Bulgaria 18.10.5106.1
Institute of
Metrology

China Custody Transfer


CPA Pattern Approval

Certificate 2012-L134

Croatia Custody Transfer

Certificate 558-02-01_01-15-2

Czech Republic Custody Transfer

Certificate 0111-CS-C022-10

Estonia Custody Transfer

Certificate TJA 6.13-3_15.09.11

France Custody Transfer

Certificate No. LNE-24609

Germany Custody Transfer

Certificate PTB-1.5-4058175

India Custody Transfer

Certificate IND/13/12/191

Indonesia Custody Transfer

Certificate DITJEN MIGAS CT approval 26.10.2010

Italy Custody Transfer

Certificate 65234 (Raptor system)

Kazakhstan Custody Transfer


GOST Pattern Approval:

Certificate KZ.02.02.06177-2018 No.14983 (5900)


KZ.02.02.04018-2014 No.10790 (System)

Emerson.com/Rosemount 51
Rosemount 5900S November 2021

Malaysia Custody Transfer

Certificate ATS 09-11

Netherlands Custody Transfer

NMI Certificate TC8934R1

Norway Custody Transfer

Certificate No. N-11-7146

Poland Custody Transfer

Certificate ZT-7 2013

Portugal Custody Transfer

Certificate P12_101.12_31

Russia Custody Transfer


GOST Pattern Approval:

Certificate SE.C.29.639.A No. 66902 (5900)

Serbia Custody Transfer

Certificate 393-7_0-01-2088

South Africa Custody Transfer

Certificate SAEx S11-065

Switzerland Custody Transfer

Certificate Zulassungszertifikat CH-L-11127-01

OIML Custody Transfer

Certificate R85/2008-A-SE1-2021.01

52 Emerson.com/Rosemount
November 2021 Rosemount 5900S

Product Certifications Rosemount 2051


Extract from Rosemount 2051 Product Certifications Rev: 1.13

North America
IE USA FISCO

Certificate FM16US0231X
Standards FM Class 3600 – 2011, FM Class 3610 – 2010, FM Class 3611 – 2004, FM Class 3810 – 2005
Markings IS CL I, DIV 1, GP A, B, C, D when connected per Rosemount drawing 02051-1009 (-50°C ≤ Ta ≤ +60°C); Type 4x

Special Conditions for Safe Use (X):


1. The Model 2051 transmitter housing contains aluminum and is considered a potential risk of ignition by impact or friction.
Care must be taken into account during installation and use to prevent impact and friction.

IF Canada Intrinsic Safety

Certificate 2041384
Standards CSA Std. C22.2 No. 142 - M1987, CSA Std. C22.2 No. 213 - M1987, CSA Std. C22.2 No. 157 - 92, ANSI/ISA
12.27.01 – 2003, CAN/CSA-E60079-0:07, CAN/CSA-E60079-11:02
Markings Intrinsically safe for Class I, Division 1, Groups A, B, C, and D when connected in accordance with Rosemount
drawing 02051-1008. Ex ia IIC T3C. Single Seal. Enclosure Type 4X

Europe
IA ATEX FISCO

Certificate Baseefa08ATEX0129X
Standards EN60079-0:2012+A11:2013, EN60079-11:2012
Markings II 1 G Ex ia IIC T4 Ga (-60°C ≤ Ta ≤ +60°C)

Ui Ii Pi Ci Li
FISCO parameters 17.5V 380 mA 5.32 W 0 µF 0 mH

Special Conditions for Safe Use (X):


1. If the equipment is fitted with an optional 90V transient suppressor, it is incapable of withstanding the 500V isolation from
earth test and this must be taken into account during installation.
2. The enclosure may be made of aluminum alloy and given a protective polyurethane paint finish; however care should be
taken to protect it from impact and abrasion when located in Zone 0.

Emerson.com/Rosemount 53
Rosemount 5900S November 2021

International
IG IECEx FISCO

Certificate IECExBAS08.0045X
Standards IEC60079-0:2011, IEC60079-11:2011
Markings Ex ia IIC T4 Ga (-60°C ≤ Ta ≤ +60°C)

Ui Ii Pi Ci Li
FISCO parameters 17.5V 380 mA 5.32 W 0 nF 0 µH

Special Conditions for Safe Use (X):


1. If the equipment is fitted with an optional 90V transient suppressor, it is incapable of withstanding the 500V isolation from
earth test and this must be taken into account during installation.
2. The enclosure may be made of aluminum alloy and given a protective polyurethane paint finish; however care should be
taken to protect it from impact and abrasion when located in Zone 0.
3. The equipment contains thin wall diaphragms. The installation, maintenance and use shall take into account the
environmental conditions to which the diaphragms will be subjected. The manufacturer’s instructions for installation and
maintenance shall be followed in detail to assure safety during its expected lifetime.

54 Emerson.com/Rosemount
November 2021 Rosemount 5900S

Dimensional drawings
Figure 5: Dimensions of Rosemount 5900S with Parabolic Antenna
226 (8.9) 177 (7.0)

244 (9.6)
297 (11.7)
170 (6.7)

440 (17.3)

Dimensions are in millimeters (inches).

Emerson.com/Rosemount 55
Rosemount 5900S November 2021

Figure 6: Dimensions of Rosemount 5900S with Horn Antenna


226 (8.9) 177 (7.0)

224 (8.8)
332 (13.1)
M32
350 (13.8)

Ø 175 (6.9)

A. Flange Inclined 4°
Dimensions are in millimeters (inches).

56 Emerson.com/Rosemount
November 2021 Rosemount 5900S

Figure 7: Dimensions of Rosemount 5900S with Still-Pipe Array Antenna


226 (8.9) 177 (7.0)

224 (9.6)
290 (11.4)
B

Dimensions are in millimeters (inches).

Table 4: Available sizes for Still-Pipe Array Antenna

Antenna diameter (D) B (mm)


5 in. / DN125 (Ø 120 mm) 56
6 in. / DN150 (Ø 145 mm) 59
8 in. / DN200 (Ø 189 mm) 65
10 in. / DN250 (Ø 243 mm) 73
12 in. / DN300 (Ø 293 mm) 79

Emerson.com/Rosemount 57
Rosemount 5900S November 2021

Figure 8: Dimensions of Rosemount 5900S with LPG/LNG Still-Pipe Antenna

250 (9.8) 226 (8.9)(1) 177 (7.0)


288 (11.3)

244 (9.6)
A

A. Approximately 488 (19.2), depending on flange type


1. 302 mm with pressure transmitter
Dimensions are in millimeters (inches).

Table 5: Available sizes for LPG/LNG Still-Pipe antenna

Antenna diameter (D) B (mm)


4 in. Sch10 (Ø 107 mm) 752
4 in. Sch40 (Ø 101 mm) 534
DN100 (Ø 99 mm) 502

58 Emerson.com/Rosemount
November 2021 Rosemount 5900S

Emerson.com/Rosemount 59
00813-0100-5900
Rev. CC
November 2021

©2021 Emerson. All rights reserved.

Emerson Terms and Conditions of Sale are available upon


request. The Emerson logo is a trademark and service mark of
Emerson Electric Co. Rosemount is a mark of one of the
Emerson family of companies. All other marks are the property
of their respective owners.

You might also like