The MagicGrid Book of Knowledge (BoK) focuses on how practitioners implement MBSE. MagicGrid has
been developed to provide a framework that can be easily adopted, implemented, and modified to grow
with your modeling and systems engineering practice. This book teaches you how to use CATIA® Magic
software to design and optimize the systems and products of today and tomorrow. It is the culmination of
many years of research, and I am proud to put the Dassault Systèmes name behind this effort.
Thank you to all the magicians who made this happen, especially our industry process consultants team
who have engaged with customers over thousands of hours to learn, digest, develop, and teach this
framework. I would also like to thank our partners and customers who contributed to peer review of this
work prior to its release.
When I started MBSE training and consulting 10 years ago, the first thing that came to my mind was that
there was a lack of an unambiguous approach to developing system models using SysML. Every customer
was developing models differently. Moreover, every consultant used different approaches to train
customers in this discipline. It should come as no surprise that SysML was (and still is) criticized for being
method-agnostic. There was no other way forward than to initiate internal discussions within the team,
and to start collecting and summarizing our experience in the form of a framework for architecting
systems using a sort of “vanilla” SysML. The framework comes first, then adjusting to the language
second. I am certain that this is the only approach that is 100 percent aligned with SysML. Extensions and
customizations are possible; however, they are not necessary.
While collecting our knowledge, I did some scientific studies with a local university to prove my ideas were
correct. Together with my team and colleagues, I wrote a couple of papers and delivered multiple
presentations and tutorials at various events worldwide, e.g., the INCOSE International Symposium,
INCOSE local chapter events, and the MBSE Cyber Experience Symposium, to name just a few. Publicity,
and a lot of positive feedback, gave me the trust and self-confidence to continue working on MagicGrid.
After working with multiple customers from various industries, I do agree that there is no single unified
approach to this issue, and there cannot be one. Every industry and every customer has their own
specifics, and we have taken this into account. MagicGrid has evolved as a foundation and collection of
best practices that can be modified or extended to support specific customer needs. Know-how captured in
this approach is highly influenced by the INCOSE handbook, ISO/IEC/IEEE 15288, the Unified Architecture
Framework (previously known as UPDM) and development efforts. Companies which influenced our
efforts included Bombardier Transportation, Kongsberg Defense and Airspace, Ford Motor Company, John
Deere, BAE Systems, and many others which I personally, along with fellow team members and
colleagues, have been working with in recent years.
I’m proud that besides the MagicGrid framework, we have managed to put together a detailed step-by-
step tutorial and publish it both as a book and an e-book. Please note that this book can only get better
with your help. Please do not hesitate to contact us and provide your feedback to make the second edition
of the book even better.
My hope is that this book will be a lighthouse for all MBSE practitioners sailing in the dark, and a light
breeze for those sailing in the sunlight.
Any theory needs practice. An approach becomes useful when it is provided together with comprehensive
instructions on how to use it in practice. The MagicGrid framework for Model-Based Systems Engineering
(MBSE) by CATIA® No Magic is no exception to this rule. This was the main reason we have decided to
write this book.
So, if you’re new at MBSE or look forward to learn about the MagicGrid framework from A to Z, this book
is for you. This book is for you, too, if you wish to learn how to use CATIA Magic software for MBSE in
combination with OMG® Systems Modeling Language (SysML)™ and MagicGrid. This book is for you as
well, if you go for comprehensive instructions, illustrated by the case study of modeling an easy-to-
understand real-world system.
The book is easier to read if you are familiar with UML/SysML and basic concepts of CATIA Magic software
for MBSE; that is, Magic Cyber-Systems Engineer / Cameo Systems Modeler or Magic Systems of Systems
Architect / Cameo Enterprise Architecture along with the Cameo DataHub plugin installed on the top, or
Magic Software Architect / MagicDraw with the SysML and Cameo DataHub plugins, as of version 19.0,
generally referred to as the modeling tool.
Why MagicGrid?
MagicGrid is the bridge between the theory and practice, bringing three major MBSE components –
method, language, and modeling tool – together.
The idea of developing a new framework for MBSE emerged while working with organizations from
various industry sectors, such as defense, automotive, aerospace, and healthcare, to name a few. They
needed an unambiguous approach for developing system models using SysML, the critical enabler for
MBSE, as defined by the International Council on Systems Engineering (INCOSE). However, quite a
few methods for MBSE were available in the market at that time, and the existing ones were too abstract
for solving a real-world problem. The practice also revealed that every industry and every customer has
their own specifics, and cannot use the standard method without applying any modifications or
extensions to it.
The MagicGrid framework has evolved by summarizing the experience of numerous MBSE adoption
projects, as a foundation and collection of best practices that can be modified or extended to support
specific customer needs.
• It is fully compatible with “vanilla” SysML, which means, no extensions for the standard SysML are
required.
• It clearly defines the modeling process, which is based on the best practices of the systems
engineering process.
• It is tool-independent, as long as that tool supports SysML.
As the title reveals, the MagicGrid framework can be represented as a Zachman style matrix (see the
following figure), and is designed to guide the engineers through the modeling process and answer their
questions, like “how to organize the model?”, “what is the modeling workflow?”, “what model artifacts
should be produced in each step of that workflow?”, “how these artifacts are linked together?”, and so on.
As you can see, the framework defines the Problem, Solution, and Implementation domains for
developing the system of interest (SoI). Each domain is represented as a separate row of the MagicGrid
framework. The row that represents the Problem domain splits into two, to convey that the Problem
domain should be defined by looking at the SoI from the black-box and then from the white-box
perspective. The row that represents the solution domain splits into numerous inner rows to convey that
the solution architecture of the system can be specified in multiple levels of detail. The row that represents
the Implementation domain doesn’t split and is not fully highlighted like the upper rows, to convey
that everything except the implementation requirements specification in this domain is not a part of MBSE
and therefore appears outside the scope of the matrix.
Each domain definition includes different aspects of the SoI. These aspects match the four pillars of the
SysML, that is, Requirements, Structure, Behavior, and Parameters (also known as Parametrics); plus, the
Safety & Reliability aspect added in the 2nd edition of this book. They are represented as columns of the
matrix.
A cell at the intersection of some row and column represents a view of the system model, which can
consist of one or more presentation artifacts. The presentation artifact can be a diagram, including the
elements that can be used for modeling there, matrix, map, or table.
Though it is not conveyed in the framework, more than one solution architecture can be provided for a
single problem. In such case, a trade-off analysis is performed to choose an optimal solution for
SoI implementation.
Before we explore MagicGrid in detail, it is important to disclose how it fits into the overall systems
engineering life cycle defined by ISO/IEC/IEEE 15288.
To start with the Business or Mission Analysis process, it is considered to be the input to the Problem
domain of the MagicGrid and is usually described by using other technologies, like OMG® Unified
Architecture Framework (UAF)®, which can be utilized in the same modeling tool, prior to applying the
MagicGrid framework for developing the identified systems.
The Problem domain of this framework covers the entire Stakeholder Needs and Requirements Definition
process. The subprocesses are mapped as follows:
The System Requirements Definition process is carried out in the System Requirements cell, although it can
be extended in the Subsystem Requirements and Component Requirements cells, too.
Right after system requirements are completed, the Architecture Definition process takes place. In
MagicGrid, it covers all system-level and subsystem-level cells of the Solution domain, except the System
Requirements and Subsystem Requirements cells. The Architecture Definition process also covers the
component-level cells, but only partially. These cells are covered by the Design Definition process, too. This
is where the architecture relates to design, or in other words, MBSE meets Model-Based Design (MBD),
and activities of the Assess architecture candidates subprocess are performed. Once they are completed, the
Design Definition process is carried out.
Finally, the Implementation process transforms requirements, architecture, and design into actions that
create the system element according to the practices of the selected implementation technology, using
appropriate technical specialties or disciplines. It is covered in the Implementation domain of MagicGrid.
In this book, the modeling framework applies to the specification and architecture of the Vehicle Climate
Control System (VCCS). Technical accuracy and the feasibility of the actual solution proposed are not high
priorities.
It’s important to understand that this book doesn’t replace the modeling tool documentation. It is
intended to supplement it.
The structure of the book corresponds the layout of the MagicGrid framework. It is divided into three main
chapters, each describing the modeling workflow within a single domain. These are the Problem
domain (including the Black-box perspective and White-box perspective sub-chapters), the Solution
domain (including sub-chapters that correspond different phases of creating the solution domain model),
and the Implementation domain.
While chapters consist of sub-chapters, the latter consist of multiple sections, each named after relevant
cell of the MagicGrid framework. The order of these cells defines the modeling workflow. Every section
includes the brief overview of the cell to explain the purpose of modeling in this cell, who is responsible for
the results, and how to model. It also gives the list of basic steps for the modeler to go through to achieve
the expected result. Each step is described in the related sub-section, which provides answers to the
questions, like “what to do?”, “why to do it?”, and “how to do it?”. Follow these instructions from the very
beginning until the end of the book to create a sample model of the VCCS by yourself. If the version of
your modeling tool is 2021x or later, you are welcome to study the sample model there; it is saved as VCCS
(MG BoK v2 Sample).mdzip.
There are information boxes marked with the symbol, in the text. These boxes are designated to
provide you with additional information, tips and tricks for smarter modeling, or references to more
detailed information sources.
• Annex A, which provides comprehensive instructions on how to enrich the system model with
safety and reliability information.
• Annex B, which provides a detailed description of transitioning from System of Systems to a single
system architecture in the model-based environment.
We appreciate any feedback from our readers for the next version of this book. Send us an email
at [email protected].
As shown in the following figure, the problem domain analysis is performed in two phases. In the first
phase, the SoI is considered a black box. The main focus is on how it interacts with the defined
environment without getting any knowledge about its internal structure and behavior (i.e., the operational
analysis of the SoI is performed). In the second phase, the black box is opened and the SoI is analyzed
from the white-box perspective, which helps to understand the expected behavior and conceptual
structure of the SoI (i.e., the functional analysis of the SoI is performed). It is also important to note that
the problem definition is not about the logical or the physical architecture of the SoI.
As you can see in the following figure, both phases of the problem domain definition consist of specifying
the requirements, structure, behavior, and parameters of the SoI. The only difference is in perspective.
Black-box perspective
Problem domain analysis and definition from the black-box perspective is the first step towards specifying
what the SoI shall do fulfill the stakeholders' expectations. The goal of this phase is to understand how
the SoI interacts with its environment to solve the given challenges. As the SoI is considered a black box,
the analysis is not concerned with its internal structure and behavior. The analysis is performed to define
the main inputs and outputs, black-box functions, and quantifiable characteristics of the SoI, while
operating in a variety of system contexts.
Stakeholder Needs
What is it?
The cell represents information gathered from various stakeholders of the SoI. This information includes
primary user needs, system-related government regulations, industry standards, policies, procedures, and
internal guidelines, etc.
Stakeholder needs can be captured by interviewing stakeholders, giving them questionnaires, discussing
needs in focus groups, or studying documents written in diverse formats. Though this information is raw,
it does not need to be specially rewritten. However, it needs to be analyzed and refined in other cells of the
problem domain model. Once this is done, traceability relationships are created to convey which artifacts
from the problem domain model refine every stakeholder need (see Chapter Traceability to Stakeholder
Needs). These refinements will serve as a basis for specifying system requirements (see Chapter System
Requirements).
Who is responsible?
The elicitation and analysis of stakeholder needs can be performed by the Requirements Engineer or
Business and Mission Analyst.
Stakeholder needs can be captured directly in the modeling tool, or imported from other tools and
formats, including:
• Requirements management tools (i.e., Requirements Engineer (TRM) (as of 19.0 SP4), IBM®
Rational® DOORS®)
• Spreadsheets (i.e., Microsoft Excel file)
• ReqIF file (which contains data exported from another tool, such as, IBM® Rational® DOORS®, PTC
Integrity Modeler, Polarion® REQUIREMENTS™, or Siemens Teamcenter)
In the modeling tool, a single stakeholder need can be captured as a SysML requirement and have a
unique identification number, name, and textual specification. The entire list of stakeholder needs can be
displayed in a SysML requirement table (see the following figure) or diagram. Stakeholder needs can be
hierarchically related to each other (grouped by source, for example). It can be two categories of them:
functional and non-functional. This facilitates further analysis of stakeholder needs.
Tutorial
• Step 1. Organizing the model for stakeholder needs
• Step 2. Creating a table for stakeholder needs
• Step 3. Capturing stakeholder needs
• Step 4. Grouping stakeholder needs
• Step 5. Numbering stakeholder needs
• Step 6. Categorizing stakeholder needs
According to the design of the MagicGrid framework, model artifacts that capture stakeholder needs
should be stored under the structure of packages, as displayed in the following figure. As you can see, the
You can skip this step (as well as other steps of establishing the model structure), if you use the
MagicGrid v2 QuickStart or MagicGrid v2 Blank template. They both come with the 2021x version of
the modeling tool, and include a predefined structure based on the MagicGrid framework.
Using numbers in package names enables you to preserve the package order in the model tree.
1. Right-click the Model package (this is the default name of the root package) and select Create
Element.
2. In the search box, type pa, the first two letters of the element type Package, and press Enter.
3. Type 1 Problem Domain to specify the name of the new package and press Enter.
4. Right-click the 1 Problem Domain package and select Create Element.
5. Repeat steps 2 and 3 to create the package named 1 Black Box.
6. Right-click the 1 Black Box package and select Create Element.
7. Repeat steps 2 and 3 to create the package named 1 Stakeholder Needs.
It is important to notice that the MagicGrid BoK always describes one possible way to complete the task
(for example, we choose to create requirement table to capture and display stakeholder needs for the
reason explained above), but this does not mean that you cannot do this in another way. For a
comprehensive description of all the alternatives, refer to the latest documentation of the modeling tool.
Note that the table is named after the package where is it stored. This name suits for the table,
too. You need only remove the sequence number from its name.
3. Select the 1 Stakeholder Needs package and drag it to the Scope box in the Criteria area of the table.
From now on, the table is updated every time you append the contents of the related package.
# Name Text
1 Ambient Temperature I want to see the ambient temperature on the screen
or some other output device.
2 Comfortable Temperature I'd like to feel comfortable temperature while being in
the cabin.
3 Desired Temperature It should be a possibility to easily specify the desired
temperature.
4 Heating & Cooling The unit must be able to heat and cool.
5 Energy Consumption I'd like the unit to consume as little energy as
possible.
6 Manual Control I should be able to start and stop climate control by
myself.
7 Sound Level Climate control unit in max mode shall not be louder
than engine.
8 Total Mass Mass of the unit shall not exceed 2 percent of the
total car mass.
A single stakeholder need can be stored as a SysML requirement, which has a unique identification, name,
and text specification.
1. Open the table created in step 2 of this cell tutorial, if not already opened.
2. On the toolbar of the table, click Add New and select Requirement.
3. In the newly created row, type the name and text of the first stakeholder need displayed in the table,
in step 3 of this cell tutorial.
4. Repeat steps 2 and 3 until you have all items in the table, as displayed in the following figure.
As you can see, items created in the SysML requirements table also appear in the Model
Browser.
If you are provided with a list of stakeholder needs in a Microsoft (MS) Excel spreadsheet, you can easily
transfer this information to the SysML model by utilizing the copy-paste capability of the modeling tool.
1. Open the spreadsheet and select the contents you want to copy to your model.
3. Switch to the modeling tool and open the SysML requirement table created in step 2 of this cell
tutorial, if not already opened.
4. Paste the contents to the table:
As you can see, items copied to the SysML requirements table also appear in the Model
Browser.
Another option to bring stakeholder needs from an MS Excel spreadsheet into a SysML model is to
synchronize the model with the spreadsheet.
1. Open the table created in step 2 of this cell tutorial, if not already opened.
2. On the toolbar of the table, click and then choose Excel/CSV File > Select File.
3. In the Excel/CSV Sync Options dialog, select the MS Excel file from your file system.
a. Select a column on the left and drag it to the relevant column on the right.
b. Release the mouse.
The modeling tool might require you to refresh the dialog before setting the mappings.
Therefore, if you see this notification at the bottom of the dialog, click Refresh.
6. Click OK.
7. When the notification appears on the bottom right corner of the modeling tool window (see the
following figure), click Read from File.
Items synchronized to the SysML requirements table also appear in the Model Browser.
As you can see, all the items in the table are highlighted in green. The legend above reveals that all new
items are highlighted like this. You can change the legend colors or hide the legend from the table. This,
along with more information about using legends, can be found in the documentation of the modeling
tool.
In such a case, information between a requirements management tool and the modeling tool can be
transferred via a Requirements Interchange Format (ReqIF) file. Thus, getting stakeholder needs into your
model includes:
We skip the first step, assuming that you’ve already been provided with the ReqIF file.
1. From the main menu, select File > Import From > Requirements Interchange Format (ReqIF) File.
2. Select the ReqIF file form your file system and click Open.
3. In the Select Package for New Data dialog, select the package where you want to store the imported
stakeholder needs (i.e., the package 1 Stakeholder Needs).
4. Click OK.
5. Wait while stakeholder needs are imported into the 1 Stakeholder Needs package. Since that package is
the scope of the SysML requirement table (see step 2 of this cell tutorial), all imported items also
appear in the table.
If stakeholder needs are gathered in an IBM® Rational® DOORS® project (see the following figure), you
can get them into the SysML model by synchronizing data between DOORS and the modeling tool.
The modeling tool can be synchronized with DOORS only if it has the Cameo DataHub Plugin
installed.
In this tutorial, we assume that DOORS are used only for capturing stakeholder needs, and further analysis
is performed in the SysML model. For this reason, we need to establish one-way synchronization between
DOORS and the modeling tool. In one-way synchronization, items are copied from DOORS to
the modeling tool, but no items are ever copied back from the modeling tool to DOORS.
Although the following procedure defines the steps for synchronization with IBM® Rational®
DOORS® Next Generation 6.x, it is also possible to synchronize requirements from IBM® Rational®
DOORS® 8.0-8.3 and 9.0-9.6 as well as from IBM® Rational® DOORS® NG 4.x and 5.x.
1. Be sure you have Cameo DataHub Plugin 19.0 or later installed on top of the modeling tool.
2. Connect to the DOORS NG 6.x repository:
a. From the main menu of the modeling tool, select Tool > DataHub > DataHub Explorer. The
Cameo DataHub Explorer panel opens to the right of the modeling tool window.
b. On the toolbar of the open panel, click the Add Data Source button.
d. Wait while the modeling tool connects to the DOORS NG 6.x repository. After the operation is
completed, the tree of the Cameo DataHub Explorer panel displays projects from the DOORS
repository (as packages). One of the projects is VCCU Project (Requirements).
3. Synchronize data:
a. In the tree of the Cameo DataHub Explorer panel, select the Stakeholder Needs package and drag
it onto the 1 Black Box package in the Model Browser on the left of the modeling tool window.
i. Click One-way Synch to Cameo Systems Modeler to select the synchronization direction.
ii. Specify the mappings:
1. Folder to Package
2. Requirement to Requirement
c. Wait for the message announcing that synchronization is completed. Synchronized items in both
trees become marked with S (see the following figure).
4. Expand the contents of the 1 Black Box package and see the Stakeholder Needs package with all its
data imported into your model.
“S” indicates synchronized data, and “1” the synchronization source. As you have selected
One-way Synch to Cameo Systems Modeler, the DOORS NG 6.x becomes the single source for
synchronization.
This does not apply if stakeholder needs are synchronized from external software for requirements
management (for example, IBM® Rational® DOORS®), because all the changes you make in the
SysML model will be overwritten after routine synchronization. Grouping, numbering, and
categorization of stakeholder needs in that case should be performed in the requirements
management tool.
After you have stakeholder needs in your model, you can arrange them into groups according to their
nature. These groups can be system-related government regulations, user needs, industry standards, or
business requirements, among others.
For grouping stakeholder needs, you need to create extra elements of the SysML requirement type, each
representing a single group of stakeholder needs and generally referred to as a grouping requirement. A
grouping requirement might not have any text itself, only a unique identification number and name.
Now let’s analyze the stakeholder needs of the Vehicle Climate Control Unit in your model. Actually, the
majority of them are user needs, and therefore can be grouped under the User Needs requirement. The
stakeholder need captured as the Total Mass requirement sounds like a design constraint. For this reason, it
should appear under the Design Constraints requirement. The top-level grouping requirement simply
named Stakeholder Needs can also be created, to complete the requirements hierarchy.
a. In the Model Browser, right-click the 1 Stakeholder Needs package and select Create Element.
b. In the search box, type re – the first letters of the requirement type, and press Enter. A new
element of the requirement type is created.
c. Type User Needs to specify the name of the requirement and press Enter.
2. In the Model Browser, select all the items except the Total Mass requirement (the first item in the list)
and the User Needs requirement (the last item in the list).
3. Drag the selection onto the User Needs requirement (see the figure on the left). It becomes a grouping
requirement (see the figure on the right).
Be sure the table is displayed in the Compact tree mode. For this, click the Options button
on the table toolbar and then select Display Mode > Compact Tree.
This does not apply if stakeholder needs are synchronized from external software for requirements
management (for example, IBM® Rational® DOORS®), because all the changes you make in the
SysML model will be overwritten after the routine synchronization. Grouping, numbering, and
categorization of stakeholder needs in that case should be performed in the requirements
management tool.
SysML requirements, which we utilize for capturing and storing stakeholder needs, may have hierarchical
numbers. The hierarchical number should not be mixed with the unique identifier, which can never be
changed.
Stakeholder needs are by default numbered using natural numbers, from 1 to infinity. In order to
distinguish stakeholder needs from system or implementation requirements, we recommend numbering
them with special prefixes (i.e., SN-, where S stands for stakeholder and N for needs).
After organizing stakeholder needs into groups, their numbering became inaccurate, as it now begins from
11. Let's fix this, too.
1. In the Model Browser, right-click Stakeholder Needs (the top-level grouping requirement), and
select Element Numbering. The Element Numbering dialog opens.
2. In the dialog, click the empty value cell of the Prefix column to initiate the editing, type SN- (see the
following figure), and press Enter. The hierarchical number of the Stakeholder Needs requirement is
updated to SN-11.
If you want to make sure that all the items are renumbered, expand the model tree on the left
side of the dialog to see the entire hierarchy of the stakeholder needs for the VCCU.
This does not apply if stakeholder needs are synchronized from external software for requirements
management (for example, IBM® Rational® DOORS®); all the changes you make in the SysML
model will be overwritten after the routine synchronization. Grouping, numbering, and
categorization of stakeholder needs should be performed in the requirements management tool.
Stakeholder needs can be either functional or non-functional. Functional stakeholder needs specify what
the SoI is expected to do. They are further refined by use cases and use case scenarios (see Chapter Use
Cases). Non-functional stakeholder needs that identify quantifiable characteristics of the SoI are refined
by measures of effectiveness (see Measures of Effectiveness).
Categorization facilitates further analysis of stakeholder needs, especially when dealing with a large scope
of information. This step may be skipped if the case does not require it.
While non-functional stakeholder needs can be captured as SysML requirements, functional stakeholder
needs should be converted to SysML functional requirements. In technical terms, functional requirement
(together with interface, performance, design, and other more specific requirements, which are not
needed thus far) is a sub-type of the requirement and inherits all its features.
In the given sample, the majority of stakeholder needs (except Sound Level, Energy Consumption, and Total
Mass) are functional. Therefore, they should be refactored to SysML functional requirements.
1. In the Model Browser or on the requirements table, select all requirements except Sound Level, Energy
Consumption, and Total Weight.
To select a set of non-adjacent items in the tree, click them one by one while holding down the
Ctrl key.
2. Right-click the selection and then choose Refactor > Convert To > More Specific > Functional
Requirement.
• Stakeholder needs are analyzed to identify system contexts (see Chapter System Context).
• Functional stakeholder needs are further analyzed and refined by use cases and use case scenarios
(see Chapter Use Cases).
• Non-functional quantifiable stakeholder needs are refined by measures of effectiveness (see
Chapter Measures of Effectiveness).
System context (or operating environment) determines an external view of the system. The system context
introduces all external entities that do not belong to the system but do interact with it. More than one
system context can be defined for a single SoI. Besides the system itself (currently considered to be a black
box), the collection of elements in the particular system context can include external systems (natural or
artificial) and users (humans, organizations) that interact with the SoI to exchange data, matter, energy, or
even human resources.
Who is responsible?
System contexts can be identified and specified by the Systems Analyst or Systems Engineer.
How to model?
System context diagram pictures the SoI at the center, with no details of its interior structure, surrounded
by all its interacting entities, such as supposed users and external systems to name a few. In the SysML
model, system contexts can be captured as elements of the SysML block type. All the entities can be
captured as SysML blocks, too. As defined by SysML, once the entity block is used in the system context
block, a part property typed by the former, is created for the latter.
We recommend using blocks rather than actors (stick man notation) to capture even human-nature
entities (for example, users of the SoI) because the actor cannot be a part of the system context in
the SysML model.
A SysML internal block diagram (ibd) can serve to represent the entities of the particular system context,
and interactions between them. Each entity is represented as a part property of the related system context
block.
Interactions within the system context can be captured as connectors with one or more item flows
between those part properties. Data, matter, or energy are items that can flow. They can be stored in the
model as signals, blocks, or value types, depending on their nature, and in general are refereed as
exchange items.
Tutorial
• Step 1. Organizing the model for the system context
• Step 2. Capturing system contexts
• Step 3. Creating an ibd for a system context
• Step 4. Capturing participants of the system context
• Step 5. Specifying interactions between the participants of system context
• Step 6. Adding item flows to the system context
It is important to understand that the SoI may operate in more than one system context. To illustrate this,
we need to capture one more system context. In this example, we will use the Vehicle in Maintenance (see
the following figure). You can create the appropriate block on your own by following the procedure above.
The recently captured system context is not included in further analysis. It is not mentioned in the
stakeholder needs and has been created for demonstration purposes only.
The diagram is named after the block that owns it. As this name perfectly suits the diagram,
there is no need to change it.
Here you should remember the SysML Specification, which tells you that blocks should be used for
defining concepts and parts are used for specifying the usage of these concepts. Any concept, once
defined in your model, can be used in many system contexts. For example, the Vehicle Climate
Control Unit SoI defined as a block can type a part property of the Vehicle in Use system context and
part property of the Vehicle in Maintenance system context, meaning that it participates in both.
Stakeholder needs indicate that the Vehicle In Use system context includes the following participants:
• Vehicle Climate Control Unit, the SoI
• Vehicle Occupant (driver or passenger), the supposed user of the SoI
• Vehicle Cabin, the closed environment that must be provided with a comfortable air temperature
• Temperature Sensor, the external system to provide an ambient temperature to the SoI
1. Open the ibd created in step 3 of this cell tutorial, if not yet opened.
In this mode, when you create a part property, the tool offers you a list of blocks, from which
you can choose the part property type. If the necessary block does not exist yet, you can
simply create it by typing its name directly on the part property shape.
3. Click the Part Property button on the diagram palette and then click an empty place on the diagram
pane. An unnamed part property is created, and the list of existing blocks to type it is offered.
4. Type VCCU next to the colon (":") directly on the part property shape and press Enter. The VCCU block
to type the just-created part property emerges in the Model Browser.
When the Type Selection Mode is enabled, typing on the part property shape always defines
the name of the new block. This new block types that part property, but not the name of the
part property. If you want to specify the name as well, type it before the colon (":") on the
shape. However, names are not necessary, since part properties created in this diagram can be
easily identified by their types. Names are useful when you want to specify more than one
usage of the same block (for example, the front-left, front-right, rear-left, and rear-right wheels
of the vehicle).
Since you need to create more than one part property in succession, use the functionality of
the Sticky button (see the following figure), so it is not necessary to click the Part Property
button on the palette each time you want to create a new part property. When the Sticky
mode is enabled, you can create as many elements of the selected type as you need. Press Esc
when you are finished.
When you are finished, you have four part properties and the same number of blocks that type them in
your model.
To keep your model well-organized, we recommend storing the blocks that capture users and other
systems in a separate package within the 2 System Context package. For this, you need to create an internal
package and drag the blocks to the new location in the Model Browser. Hold down the Shift key to select
more than one block.
Remember that interactions can be specified as connectors with one or more item flows between
appropriate part properties. We will start with drawing the connectors.
To draw a connector between the :VCCU and :Vehicle Occupant part properties
1. Select the :VCCU part property and click the Connector button on its smart manipulator toolbar.
2. Select the :Vehicle Occupant part property. The connector is created.
If we assume that you have created the 3 Exchange Items package (the package number is 3 because
number 2 will be used for the White Box package) on your own, we can move directly to creating items that
can flow and assigning item flows to the connectors. One or more item flows can be assigned on a single
connector.
Air and Comfortable Air are matter; thus, they can be captured in the model as blocks. The rest of the
items can be captured as signals, because they mean data.
To capture the User Command, Desired Temperature, and Information in the model and specify them as
items conveyed by the item flows between the :VCCU and :Vehicle Occupant part properties
As you can see in the figure below, system context diagrams can be supplemented with various images so
the result could be presented to stakeholders, including even those who are incapable of reading models.
For more information, see the latest documentation of the modeling tool.
• System contexts are used to analyze the expected behavior of the SoI (see Chapter Use Cases).
Behavior analysis begins with identifying the use cases of the SoI, and each use case belongs to one
or more system contexts of that SoI.
• Participants of each system context captured as part properties of that system context are also used
in the Use Cases cell. They can be represented as swimlanes in the SysML activity diagram that
describes a use case scenario.
• Exchange items identified in the System Context cell are used in the use case scenario as object flow
items and pin types.
• After the block that captures the system of interest is created, quantitative characteristics of the
system describing non-functional stakeholder needs can be captured. Thus, you can switch
to Measures of Effectiveness.
In this cell, functional stakeholder needs are refined with use cases and use case scenarios. In comparison
to stakeholder needs, use cases are more precise in telling what people expect from the system and what
they want to achieve by using it. Each use case must belong to one or more system contexts defined in
the System Context cell (see Chapter System Context).
Who is responsible?
Use cases and their scenarios can be specified by the Systems Analyst or Systems Engineer.
How to model?
In the modeling tool, use cases of the system can be captured by utilizing the infrastructure of the SysML
use case diagram. Every use case diagram should be created considering one of the system contexts
defined in the System Context cell (see Chapter System Context). Use cases can be captured as elements
of the use case type. A single use case can be performed in different contexts.
Entities that perform one or more use cases of the system context should be represented as blocks in the
use case diagram. Here you should remember that these blocks type part properties of the system context.
As you can see in the following figure, even humans, such as the vehicle occupant, can be represented as
blocks (with or without images applied).
Each use case must have a name and primary scenario. Alternative scenarios are optional. A use case
scenario can be captured in a form of SysML activity or sequence diagram. In the activity diagram, SoI,
supposed users of the system, and/or other systems can be represented as swimlanes (activity partitions).
In the sequence diagram, they are represented as lifelines. The SoI is meanwhile considered a black box.
If you have more than one system context, we recommend storing use cases of each system
context in a separate package. In this case, you do not need to.
3. Type Use Cases of Vehicle In Use SC to specify the name of the new diagram and press Enter again.
4. In the Model Browser, select the Vehicle In Use block. For this, use the quick find capability:
5. Drag the Vehicle In Use block to the newly created use case diagram pane. The shape of the Vehicle In
Use block appears on the diagram.
As you can see in the figure below, the Vehicle Occupant block can be displayed as an image you applied on
that block in the ibd of the Vehicle In Use system context (see Chapter System Context). For this, select the
block and click the Show As Image button on the diagram toolbar.
1. Open the use case diagram created in step 2 of this cell tutorial, if not yet opened.
2. Click the Use Case button on the diagram palette and move the mouse over the shape of the Vehicle In
Use block.
3. When you see the blue border around the shape of the Vehicle In Use block, click it. An unnamed use
case is created within the shape of the block.
4. Type Provide Comfortable Temperature to specify the name of this use case and press Enter.
5. Double-click the use case to open its Specification and make sure that the Vehicle In Use block is set as
its subject.
6. Select the Vehicle Occupant block (with or without image applied) that represents the user of the VCCU,
click the Association button on its smart manipulator toolbar, and then select the Provide
Comfortable Temperature use case to relate these two elements.
1. In the Use Cases of Vehicle In Use SC diagram, right-click the shape of the Provide Comfortable
Temperature use case and select Create Diagram.
2. In the search box, type act, the acronym of the SysML activity diagram, and press Enter. The diagram
is created and opened. It is owned by the SysML activity with the same name.
If you refer to the use case diagram, which displays the Provide Comfortable Temperature use
case, you can see that the shape of that use case is decorated with the rake ( ) icon. This
decoration means that the use case contains an internal diagram, the Provide Comfortable
Temperature activity diagram. Double-clicking the shape of the use case opens that internal
diagram.
Remember that participants of the system context are captured as its part properties. When you create
swimlanes in the activity diagram of the nested use case, the modeling tool automatically recognizes and
suggests the part properties of the nesting system context for you to select for representation.
Additionally, you need to enable the allocation to usage mode in your activity diagram. This mode allows
you to convey that allocations are established considering the system context. Otherwise, allocations are
generic, unrelated to any system context.
Now let's represent the participants of the Vehicle In Use system context in the Provide Comfortable
Temperature use case scenario.
1. Open the activity diagram created in step 4 of this cell tutorial, if not yet opened.
2. Click the Vertical Swimlanes button on the activity diagram palette and then click an empty space on
that diagram pane.
3. In the open dialog, select Usage (Action allocated to Part) to enable the allocation to usage mode and
then click OK.
4. In the Represent Properties dialog, click OK to represent all the participants of the related system
context.
5. Click the OK button on the dialog. The swimlanes are displayed on the diagram.
Swimlanes are always arranged alphabetically from A to Z, but the buttons and (which
appear when you select the header of the swimlane) enable you to rearrange them according
to your preference in the activity diagram.
When you are finished, you're ready to specify the Provide Comfortable Temperature use case scenario.
To capture the steps of the main flow of the Provide Comfortable Temperature use case scenario
1. Be sure the Behavior Creation Mode is enabled in the diagram (see the following figure). Otherwise,
activities will not be created and assigned as behaviors to call behavior actions.
Be sure to type the name after the colon (":"). Otherwise, the name is given to the action, but
not to the referred activity.
5. Click the Control Flow button on the smart manipulator toolbar of the newly created action and
then click an empty place on the diagram pane, within the :VCCU swimlane. An unnamed action with
a new activity assigned as its behavior is created.
6. Type Check System to name the activity. Remember to type after the colon. Press Enter after you are
finished.
7. Repeat steps 5 and 6 as many times as you need to create the actions you see in the following figure.
8. Select the shape of the Stop Climate Control action and click the Control Flow button on its smart
manipulator toolbar.
Now let's split the flow into two: the main flow, when the system can be started after checking, and the
alternative flow, when it cannot. To do this, we need to insert a decision node between the Check System
and Start Climate Control actions, and a merge node before the activity final node.
1. Click the Decision button on the diagram palette and then click the control flow between the Check
System and Start Climate Control actions. The decision node is inserted.
Before inserting the new shape, you can make more space between the existing shapes on the
diagram pane. To do this, click the Pusher button on the diagram palette.
2. Select the control flow between the decision node and the Start Climate Control action, type [OK, and
press Enter (the closing bracket is added automatically). As a result, the OK guard is specified for this
control flow and displayed between square brackets on the diagram.
3. Click the Merge button on the diagram palette and then click the control flow before the activity final
node.
4. Select the decision node, click the Control Flow button on its smart manipulator toolbar, then click
the merge node. The control flow is created.
5. Select that control flow, type [Not OK, and press Enter. The Not OK guard is specified for this control
flow and displayed between square brackets on the diagram.
After you finish, your Provide Comfortable Temperature diagram should look very similar to the one in the
following figure.
There is one more alternative flow that must be specified in the scenario, which says the vehicle occupant
can either set the desired temperature or enjoy the ambient temperature after they evaluate the comfort in
the cabin. For this, you need to insert another pair of decision and merge nodes in the diagram.
1. Click the Decision button on the diagram palette and then click the control flow between the Evaluate
Comfort and Set Temperature actions. The decision node is inserted.
2. Select the control flow between the decision node and the Set Temperature action, type [Not
Comfortable, and press Enter. The Not Comfortable guard is specified for this control flow and displayed
between square brackets on the diagram.
3. Click the Control Flow button on the smart manipulator toolbar of the newly created decision node
and then select the Enjoy Temperature action. A new control flow is created.
4. Immediately type [Comfortable. The Comfortable guard is specified for this control flow and displayed
between square brackets on the diagram.
5. Click the Merge button on the diagram palette and then click the control flow between the Start
Climate Control and Measure Temperature actions.
6. Select the control flow between the Get Comfortable Air and Enjoy Temperature actions, click its arrow
end, and then drag it to the newly created merge node. The target node of the control flow changes.
After you finish, your Provide Comfortable Temperature diagram should look very similar to the one in the
following figure.
The simulation engine of the modeling tool, based on the OMG® Executable UML (fUML)™
standard, enables you to validate the specified behavior and see if your model is correct. To start the
simulation session, click the Run button on the Provide Comfortable Temperature activity diagram
toolbar. Then in the Simulation panel, click the Start button to start the model execution.
So far, we have used control flows to connect actions. In the next step we will specify what data, matter, or
energy flows between actions.
Before adding item flows to the activity diagram which captures the Provide Comfortable Temperature use
case scenario, we need to look at the Vehicle In Use ibd first. Let's start from the interaction between the
:Vehicle Occupant and the :VCCU part properties. We see that the vehicle occupant provides control
commands to and sets the desired temperature for the VCCU (see the highlighted fragment of the diagram
below).
The item flows conveying these signals must be realized between these part properties in the use case
scenario, as well. Remember that part properties specified in the Vehicle In Use ibd are represented by
swimlanes in the Provide Comfortable Temperature activity diagram. Item flows should be conveyed by
object flows, not control flows. Therefore, we need to convert relevant control flows to object flows.
To realize item flows conveying the User Command signal between the actions allocated to the :Vehicle
Occupant and the :VCCU part properties
1. Select the control flow between the Turn On Climate Control and Check System actions.
2. Right-click the selection and choose Refactor > Convert To > Object Flow. The control flow turns to
the object flow, and pins are created for both actions.
3. In the Model Browser, under the 3 Exchange Items package, select the User Command signal.
4. Drag the signal to the output pin of the Turn On Climate Control action. The User Command type is set
as the type for the output pin.
5. Drag the signal to the input pin of the Check System actions. The User Command type is set as the type
for the input pin.
6. Select the object flow and click Item Flow Manager button from its smart manipulator toolbar.
7. In the open dialog, select the item flow that conveys the User Command signal (see the following
figure). The item flow is realized between the relevant actions.
When you finish, your diagram should look the same as in the figure below.
You may notice that pins display their types only. For this, do the following:
1. Press down the Alt key and select any input pin. All input pins are selected on the diagram.
2. Right-click the selection, click Show Name to clear the selection, and then click to select the
Show Type check box.
1. Select the Set Temperature action and click the Object Flow button on its smart manipulator
toolbar.
2. Click the Reach Desired Temperature action. The object flow with pins for both actions is created.
3. In the Model Browser, under the 3 Exchange Items package, select the Desired Temperature signal.
4. Drag the signal to the output pin of the Set Temperature action. The Desired Temperature type is set as
the type for the output pin.
5. Drag the signal to the input pin of the Reach Desired Temperature actions. The Desired Temperature type
is set as the type for the input pin.
6. Select the object flow and click Item Flow Manager button on its smart manipulator toolbar.
7. In the open dialog, select the item flow that conveys the Desired Temperature signal. The signal
becomes the conveyed item of the object flow.
8. Click Close to close the dialog.
When you finish, your diagram should look the same as in the figure below.
You may notice that pins don't display their types, and only item flows are shown on the diagram.
This makes the diagram less crowded and easier to read. If you want to get rid of pin types, do the
following:
1. Press down the Alt key and select any input pin. All input pins are selected on the diagram.
2. Right-click the selection and click Show Type to clear the selection.
3. Repeat the steps above to hide the output pin types.
After you finish, your diagram should look similar to the one below. You may notice that all the item flows
here are the same as in the Vehicle In Use ibd. Always remember that a precise and complete model
requires item flow synchronization between system structure and behavior. For this reason, all exchange
items identified in the structural model must be considered and included in the behavioral model as well.
Now you can initiate and run the simulation session to execute the model and validate the specified
behavior.
1. Click the small black triangle next to the Fork Horizontal button on the diagram palette and
then select Fork Vertical.
2. Click the object flow between the Measure Temperature and Display Temperature actions. The vertical
fork node is inserted.
3. Click the vertical fork node and then click the Object Flow button on its smart manipulator toolbar.
Select the Reach Desired Temperature action. The object flow and input pin for that action are created.
The input pin is automatically typed by the Ambient Temperature signal. You do not need to change
anything.
4. Select the object flow and click the Item Flow Manager button from its smart manipulator toolbar.
5. In the open dialog, click to select the single item flow that conveys the Ambient Temperature signal.
The signal becomes the conveyed item of the object flow.
6. Click Close to close the dialog.
The use case scenario can now be considered as complete. You can initiate and run the simulation session
again, to execute the model and validate the specified behavior.
In this cell, non-functional stakeholder needs are refined with measures of effectiveness (MoEs), which
capture quantifiable characteristics of the SoI in a numerical format. MoEs is a traditional term widely used
in systems engineering, describing how well a system carries out a task within a specific context. In the
problem domain model, they serve as high level key performance indicators that would be automatically
checked within the solution domain model: with MoEs, you can specify design constraints that can be
used to verify the system design.
The same set of MoEs can be used in different models to specify numerical characteristics of other
systems of interest.
Who is responsible?
How to model?
To capture MoEs in the modeling tool, a SysML block definition diagram (bdd) can be used. To define a
reusable set of MoEs, a separate block should be created and set as a super-type of the block that stands
for the SoI. In real-world projects, blocks with reusable sets of MoEs can be stored in external models, also
known as libraries. MoEs are captured as value properties with «moe» stereotypes applied. The SoI block
inherits them from the super-type block. A mechanism of redefinition in the modeling tool allows you to
define different default values and refine different requirements by every single MoE.
Tutorial
• Step 1. Organizing the model for MoEs
• Step 2. Creating a block for capturing MoEs
• Step 3. Capturing MoEs for the SoI
Note that the diagram is named after the package where is it stored. This name also suits the
diagram. You need only remove the sequence number from its name.
3. Click the Block button on the diagram palette and then click the empty space in that diagram
pane. An unnamed block is created.
4. Type MoEs Holder to specify the name of this block and press Enter.
6. Drag the VCCU block to the diagram pane. The shape of the VCCU block appears on the diagram.
7. Click the Generalization button on the smart manipulator toolbar of the MoEs Holder block and
then click the shape of the VCCU block. The MoEs Holder block becomes the super-type of
the VCCU block.
1. Select the shape of the MoEs Holder block and click the Create Element button > Value Property.
2. Type soundLevel to specify the name of the new value property and press Enter.
You can type "/" in front of the property name, for example, /soundLevel, to indicate that it is
derivable. Otherwise, to set the Is Derived property value to true, you need to right-click the
property and then select the Is Derived check box.
MoEs may have units, which can be captured in the model as value types. The majority of the commonly
used value types are stored in the ISO 80000 library of units, which is provided by the modeling tool.
1. Select any of the value properties and click ISO on the smart manipulator toolbar. Wait until the library
of units is loaded.
2. Select the totalMass value property and click the Specify Type button on the smart manipulator
toolbar.
3. Type kilog to find the mass[kilogram] value type and select it. The type is specified.
Be default, value types are filtered to show basic units only. However, the list may not include
the required value types, and you may need to extend it. For this, the Basic Units matrix should
be updated. For more information, refer to the latest documentation of the modeling tool.
4. Repeat steps 2 and 3 to find work[megajoules] and set it as the type for the totalEnergyConsumption
value property.
1. Select the soundLevel value property and click the Specify Type button on the smart manipulator
toolbar.
2. Type dBA and press Enter. The custom value type is created in the model, directly under the package 4
Measures of Effectiveness, and specified as the value type of the soundLevel value property.
If you want to display MoEs on the shape of the VCCU block (see the following figure), you need to update
the symbol properties of that block. For this, right-click the VCCU block, select Symbol Properties, and
then in the open dialog, find the Show Inherited property (make sure the All mode is switched on in the
dialog, or you will not be able to find it). Once you do this, set the property value to true.
If you want to make changes to the inherited MoEs of the SoI, you need to redefine them. Let's say you
want to change their names to make them more specific.
In the second phase of the problem domain definition, you should perform deeper analysis of system
functions in order to identify the conceptual subsystems (referred to as functional blocks in some
methodologies) of the SoI. Conceptual subsystems are the first step towards the logical solution
architecture of the SoI.
Deeper analysis of system functions is called functional analysis. As the following figure shows, every
function performed by the SoI, as identified in the Use Case cell (layer 2), is decomposed in the Functional
Analysis cell (layer 3). Functions of the detailed behavior are then allocated to conceptual subsystems (aka
functional blocks) to convey that each conceptual subsystem (aka functional block) is responsible for
performing one or more functions.
The functional decomposition process can have as many iterations as needed to achieve the relevant
granularity of the problem domain definition. The following figure shows that functions at each layer of
detail can be decomposed into even more detailed behavior. Conceptual subsystems are accordingly
decomposed into more elementary structures. It is important to note that the granularity of system
behavior and structure must be consistent in each level of detail.
After functional subsystems are identified, interactions between them can be specified. Every subsystem
can have its own quantitative characteristics (i.e., measures of effectiveness). The functions of the SoI, its
Read the following pages to learn how to create the problem domain from the white-box perspective.
Functional Analysis
What is it?
In this cell, you should more deeply analyze the expected system behavior by decomposing every function
identified during the black-box analysis (see Chapter Use Cases) and performed by the SoI.
Decomposing each function into more detailed system behavior gives stimulus to identify the conceptual
subsystems (aka functional blocks) that are responsible for performing these functions. Conceptual
subsystems are captured in the next cell of the white-box analysis (see Chapter Conceptual Subsystems).
It is important to note that with deeper analysis, the subfunctions of a decomposed function can be
decomposed as well. Decomposition can be performed as many times as you need to achieve the relevant
granularity of the problem you need to address. Every decomposed subfunction is regarded as a function
from the standpoint of its subfunctions.
The result of the Functional Analysis cell is the model of the expected system behavior. An activity
decomposition map starting from the high-level goals of the SoI and ending with the expected functions
of it can be extracted from that model.
Who is responsible?
As a continuation of the use case analysis, functional analysis can be performed by the Systems Analyst
or Systems Engineer.
Functional analysis is a continuity of use case scenario refinements using SysML activity diagrams. A new
SysML activity diagram should be created for every function allocated to SoI (see Chapter Use Cases).
Though there are two or even more swimlane partitions, you should choose only those functions that are
nested under the partition representing the usage of block that captures your SoI. The following figure
shows the white-box scenario of the Reach Desired Temperature function (which is a part of the Provide
Comfortable Temperature use case scenario) performed by the VCCU SoI.
Additionally, you need to change the location of the Reach Desired Temperature activity in your model by
moving it to the 3 Functional Analysis package, a sub-package of the 2 White Box package (created in the
previous step of this cell tutorial).
2. Select the shape of the Reach Desired Temperature action and click the SysML Activity Diagram button
on its smart manipulator toolbar (see the following figure). A newly created activity diagram
opens.
If you go back to the Provide Comfortable Temperature activity diagram (simply by clicking
on the open diagram toolbar), you can see that the shape of the Reach Desired Temperature
action is decorated with the rake ( ) icon, indicating that the action contains an internal
diagram, which opens by double-clicking the shape of that action.
a. Right-click the shape of the Reach Desired Temperature action on the diagram pane.
b. Select Go To > Behavior Reach Desired Temperature. The activity is selected in the Model
Browser.
4. Drag the Reach Desired Temperature activity to the package 3 Functional Analysis (within the 2 White
Box package). The related activity diagram is moved in together.
When you finish the white-box analysis in a real-world project, all the activities that capture the functions
of the SoI (they appear within the :VCCU swimlane in the Provide Comfortable Temperature activity diagram)
must be stored in the 3 Functional Analysis package.
The activity diagram has a few inputs and an output. In terms of SysML, these are activity parameter
nodes and they correspond the input and output pins of the Reach Desired Temperature action in the Provide
Comfortable Temperature activity diagram. Inputs and outputs are a good starting point and should be
considered when specifying the scenario. Additionally, you can remove their names to remove
unnecessary information and have more space on the diagram pane.
1. Click the node once. When it is selected, click its name. The name is selected.
2. Press the Delete button on the keyboard.
This time before starting to specify the scenario, you don't need to create any swimlanes in the diagram.
You can do this later, as soon as you have conceptual subsystems (aka functional blocks) captured in your
model.
1. Be sure the Behavior Creation Mode is enabled in the diagram. If it is not enabled, activities will not be
created and assigned as behaviors to call behavior actions. For this, click the Behavior Creation Mode
button .
2. Click the Initial Node button on the diagram palette and then click an empty place on the diagram
pane. The initial node is created.
3. Click the Control Flow button on the smart manipulator of the initial node shape, and then click an
empty place on the diagram pane. An unnamed action with a new activity assigned as its behavior is
created.
4. Type Read Desired Temperature and press Enter.
Be sure you type the name after the colon (":"), or the name will be given to the action, but not
to the referred activity.
5. Select the :Desired Temperature node and click on its smart manipulator toolbar.
Remember that to hide the input pin name and show its type, you need to right-click that pin,
click the Show Name check-box to clear the selection, and then click to select the Show
Type check box.
7. Capture other items to build the complete scenario, which is displayed in the following figure using
the following guidelines:
• To capture new actions, click the Control Flow or Object Flow on the smart manipulator
toolbar. When you create the object flow, do not forget to right-click an empty place in the
diagram pane and then select Call Behavior Action (otherwise the Central Buffer Node may
appear on the diagram).
• To connect two actions, click the Control Flow or Object Flow on the smart manipulator
toolbar of the source action, then click the target action.
• To set the type for a pin (unless it is not automatically set), drag the appropriate element (block or
signal) from the Model Browser.
• To create the decision or merge node, right-click an empty place in the diagram pane and then
select Decision or Merge.
• To specify a guard, select the relevant control flow, type the square bracket, and then specify the
condition, such as [Desired Temperature < Ambient Temperature. Keep in mind that you do not need
to close the brackets manually. This is done automatically once you press Enter.
• To create an output pin and an object flow to the output parameter node, click the Object Flow
on the smart manipulator toolbar of that action and then click the output parameter node you
want to relate. The output pin is created in tandem and its type is set automatically by the type
of the related output parameter node.
• To change the type of the element you want to create at the arrow end of the new control flow
(for example, from action to decision or from decision to merge), right-click an empty place in the
diagram pane and select that type.
You can run the simulation to validate the specified behavior and see if your model is correct. To start the
simulation session, click the Run button on the Reach Desired Temperature activity diagram toolbar.
When in the Simulation panel, click the Start button to start the model execution.
This scenario enables us to presume that the Vehicle Climate Control Unit may consist of four subsystems:
one for receiving data from outside the system, one for cooling the air, one for heating it, and one for
controlling other systems. The next cell of the MagicGrid framework describes how to capture them.
c. When you see the Provide Comfortable Temperature activity in the search results list, select it and
press Enter. The activity is selected in the Model Browser.
If there are no results in the diagram types list, click the Expert button below it. The list of
available diagrams expands in the Expert mode.
Note that the diagram is named after the enclosing activity. This name suits the diagram as
well, so no changes are needed.
If only the fragments of long element names are displayed, you can change the map settings
to display the complete element names. For this, click the Options button on the relation
map toolbar and click to unselect Cut Element Names.
While functional analysis (see Chapter Functional Analysis) helps identify conceptual subsystems (aka
functional blocks), this cell captures them in the model. The conceptual subsystems should be considered
as a group of interconnected and interactive parts that are responsible for performing one or more
expected functions of the SoI.
It’s important to note that every conceptual subsystem can be decomposed into a more elementary
structure. The number of iterations of such decomposition depends on the granularity level of the
conceptual architecture you want to address. Every subsystem is regarded as a system from the standpoint
of its internal parts.
Once the conceptual subsystems are captured in the model, it is time to specify which system functions
they perform. For this, functions are allocated to conceptual subsystems. Remember that the granularity
of expected system behavior and structure must be consistent in each level of detail; thus, you cannot
assign the function of the subsystem to its component or function of that component to the subsystem.
Deeper analysis is only possible after you have completely finished the current level of granularity. The
recommended correspondence between the granularity levels of behavioral and structural decomposition
is displayed in Chapter White-box perspective.
Inputs and outputs of the SoI are also considered in this cell. They are identified by analyzing the system
context and use case scenarios, while others are determined considering the results of the functional
analysis.
It should be kept in mind that it is not always necessary to specify the conceptual architecture of
the SoI. For example, when MagicGrid is used to modernize an already existing system, the
Conceptual Subsystems cell can be skipped to define the logical architecture of the SOI
straightaway.
Who is responsible?
The structural decomposition of the system can be performed and its internal communications can be
specified by the Systems Analyst or Systems Engineer.
To capture inputs and outputs of the SoI or any of its conceptual subsystems, you can use the
infrastructure of the bdd. These inputs and outputs can be specified as SysML flow properties. As defined
by SysML, these can be grouped by interface blocks that are stored somewhere in the model or even in
some external library. Proxy ports are used to relate interface blocks to the blocks that capture the
structure of the SoI. The following figure shows the inputs and outputs of the Vehicle Climate Control Unit
and one of its conceptual subsystems, the Processing subsystem.
To define the conceptual subsystems of the SoI and the interactions between them, you can utilize the
infrastructure of the ibd created for the block that captures the SoI in your model. Conceptual subsystems,
identified while performing the functional analysis (see Chapter Functional Analysis), can be specified as
part properties of the block that represents the SoI. Connectors with one or more item flows between
these part properties indicate interactions between appropriate conceptual subsystems. Connectors with
item flows between part properties and the diagram frame represent interactions between conceptual
subsystems and the outside of the SoI. Connections should be established via proxy ports. The following
figure shows the conceptual subsystems of the Vehicle Climate Control Unit as well as their
communication with the outside and in between.
a. Right-click the 2 Conceptual Subsystems Communication package and select Create Diagram.
b. In the search box, type bdd, the acronym of the SysML block definition diagram, and then press
Enter. The diagram is created.
c. Type VCCU Interfaces to specify the name of the new diagram and press Enter again.
2. In the Model Browser, select the VCCU block using the quick find capability:
3. Drag the VCCU block to the newly created package 2 Conceptual Subsystems Communication (see step 1
of this cell tutorial). If a message appears, asking if you want to move block's relationships together,
click Yes.
4. Drag the VCCU block to the newly created diagram pane. The shape of the block appears on the
diagram.
This information serves as input to specify conceptual interfaces of the SoI, for defining its communication
with the outside: supposed users and other entities of the Vehicle In Use system context. Conceptual
interfaces for internal communication will be considered and captured later, after we define conceptual
subsystems (also known as functional blocks) of the SoI.
Remember that inputs and outputs can be captured as flow properties. Flow properties with in direction
indicate inputs, and flow properties with out direction indicate outputs. Flow property names are not as
relevant as their types. Blocks and signals that capture exchange items of the Vehicle In Use system context
become flow property types.
A single flow property always belongs to some interface block. A proxy port is a usage of that interface
block on the block, which captures the SoI. Proxy port names are relevant, if more than one proxy port is
typed by the same interface block; otherwise, their names are not important.
To create the interface block for providing manual control and relate it to the VCCU block
a. Remove the out part of the flow property direction indicator to specify that the direction of the
flow property is in.
b. Type uc to specify the flow property name.
c. Type :Use and pres Ctrl + Spacebar to open the list of possible flow property types. Once you see
the User Command signal in that list, select it. The type is set.
7. Select the Manual Control interface block on the diagram and drag it onto the VCCU block. As a result,
a new proxy port, typed by the Manual Control interface block, is created for the VCCU block. As can
see, it is decorated with an arrow indicating that this port is for inputs to the system of interest.
If you hover over the proxy port shape, the tooltip shows which inputs can be provided to the
system over this proxy port.
Following the procedure above, create the interface blocks with flow properties (shown in the following
figure) and then relate them to the VCCU block by creating proxy ports.
The following figure displays the Blackbox ICD Table, an alternative view of the Vehicle Climate Control
Unit interfaces. This tutorial doesn’t explain how to build the table, but you can find this information in
the latest documentation of the modeling tool.
To keep the model well-structured, we recommend storing all the interface blocks in a separate package.
For this, you need to create the 1 Conceptual Interfaces package directly under the 2 Conceptual Subsystems
Communication package and then drag all the interface blocks to it.
1. On the VCCU Interfaces diagram, select the shape of the VCCU block and click the SysML Internal Block
Diagram button on its smart manipulator. A new ibd named after the enclosing block is created,
and the Display Parts/Ports dialog opens.
2. Make sure all the proxy ports of the VCCU block are selected and click OK. The proxy ports are
displayed on the newly created diagram frame.
3. Type VCCU Conceptual Subsystems Communication to specify the name of the new diagram and press
Enter again.
The final view of your diagram should be similar to the one in the following figure.
While the VCCU Interfaces bdd (see step 3 of this cell tutorial) represents the SoI as a black box, the
idb is created to represent the same system as a white box: the VCCU block is opened to see its
internal structure. That’s why proxy ports displayed on the borders of the VCCU block in the bdd are
displayed on the diagram frame in the ibd.
They can be specified as part properties of the VCCU block. Part properties don’t need names, but they
should be typed by blocks that capture the conceptual subsystems listed above.
1. Open the VCCU Conceptual Subsystems Communication ibd, created in step 4 of this cell tutorial, if
not yet opened.
2. Make sure the Type Selection Mode is on in the diagram. Otherwise, parts created in this diagram will
not be typed by blocks.
3. Click the Part Property button on the diagram palette and then click an empty place on the diagram
pane. An unnamed part property is created, and the list of existing blocks to type it is offered.
4. Type Cooling next to the colon (":") directly on the part property shape and press Enter. The
Cooling block to type the just-created part property is created in the Model Browser.
5. Repeat steps 3 and 4 to create another conceptual subsystem from the list above.
When you’re done, your VCCU Conceptual Subsystems Communication ibd should look very similar to the
one in the following figure.
If the functional analysis requires decomposing one or more subsystems of the SoI, we highly
recommend using the same model structure pattern for each subsystem as you used for the SoI.
Repeating the structure created at this level of detail for every lower level helps to establish a good
and easily readable recursive structure of the model.
To specify the interactions between the Cooling subsystem and the outside of the SoI
1. Select the proxy port typed by the Cabin Air Inlet interface block and click Connector button on its
smart manipulator toolbar.
2. Click the :Cooling part property and select New Proxy Port (see the following figure). A new
compatible proxy port is created. As shown below, it is typed by the same interface block.
3. In the Model Browser, select the Air block. For this, use the quick find capability:
4. Drag the Air block to the newly created connector on the open diagram pane.
5. Don’t make any changes in the open dialog; click Finish. The Air block is specified as the item flowing
over the newly created connector.
6. Repeat steps 1 and 2 to create a connector between the proxy port typed by the Cabin Air Outlet
interface block and the :Cooling part property.
7. Repeat step 3 to select the Comfortable Air block in the Model Browser.
8. Drag the block to the newly created connector.
9. In the open dialog, change the direction of the flow to From Cooling System To VCCU and click
Finish. The Comfortable Air block is specified as the item flowing over the newly created connector.
As you can see, the proxy port names are hidden in this diagram. This greatly increases the
readability of this diagram. To hide the names of proxy ports, do the following:
1. Press Alt and hold it down while you select any proxy port; all proxy ports in that diagram are
selected.
2. Right-click the selection and then click to clear the Show Name check box.
Now specify that the Processing subsystem takes the Ambient Temperature from the outside, and the
Handling Human-Machine Interactions subsystem accepts the User Commands and Desired Temperature
from there. The latter provides various Information to the outside, too.
After you specify this by following the instructions above, your VCCU Conceptual Subsystems
Communication diagram should look very similar to the one below.
The list above requires you to capture a few more interface blocks. You can see them highlighted in the
following figure, which displays the Processing Subsystem Interfaces diagram.
As you can see, the CU Command signal has two sub-types: the Cool and Heat signal. With this hierarchy of
signals, you can specify exactly which signal is flowing through the same conceptual interface in each
particular case. It is the Cool signal between the :Processing and the :Cooling part properties, and the Heat
signal between the :Processing and the :Heating part properties.
The Information signal has sub-types, too. These are the Ambient Temperature, Desired Temperature, and
Status signals. We need them if we want to be more specific in specifying which kind of information can
go through the proxy ports typed by the Output Information or Internal Data Transfer interface blocks.
Sub-types can be specified in a separate bdd, the Exchange Items diagram. You already know how to create
a new bdd, display existing and create new elements there, and establish generalization
relationships between them. Therefore, we assume that you do this on your own. To display the contents
of the Exchange Items diagram within the Processing Subsystem Interfaces diagram, you need to drag
the Exchange Items diagram from the Model Browser onto the pane of the Processing Subsystem Interfaces
diagram. Then, on the smart manipulator toolbar of the Exchange Items diagram shape, click the Show
Diagram Overview Content button .
Now let's move on and specify the interactions among conceptual subsystems of the Vehicle Climate
Control Unit.
1. Open the VCCU Conceptual Subsystems Communication ibd, if not yet opened.
2. Select the :Processing part property and click Display All Ports button on its smart manipulator
toolbar.
3. Select the proxy port typed by the Internal Data Transfer interface block and click the Connector
button , its smart manipulator toolbar.
4. Click the :Human-Machine Interacting part property and select New Proxy Port. A new compatible
proxy port is created. As you can see, it is typed by the same interface block.
5. In the Model Browser, under the 3 Exchange Items package, select the Desired Temperature signal and
drag it to the newly created connector.
6. In the open dialog, change the direction of the flow to From Human-Machine Interacting to
Processing and click Finish. The Desired Temperature signal is specified as the item flowing over the
newly created connector.
7. In the Model Browser, under the 3 Exchange Items package, select the Ambient Temperature signal and
drag it to the newly created connector.
8. Don't change anything in the open dialog and click Finish. The Ambient Temperature signal is specified
as the item flowing over the newly created connector.
9. Repeat steps 7 and 8, to specify the Status signal as the item flowing over the newly created
connector.
To be more precise, you can also specify that the Comfortable Air flowing out of the Cooling subsystem is
Cooled Air, and the one flowing out of the Heating subsystem is Heated Air. Appropriate blocks should be
Since you have two sub-types of the Comfortable Air block, you can update the items flowing over the
connectors between the :Cooling part property and the diagram frame as well as between the :Heating part
property and the diagram frame. You already know how to do this. As you no longer need the Comfortable
Air block flowing over the connector, you can simply get rid of it.
1. Select the relevant connector and click the Item Flow Manager button on its smart manipulator
toolbar.
2. In the open dialog, click to clear the selection of the row where the conveyed item is the Comfortable
Air block.
The following figure displays an alternate view of the VCCU Conceptual Subsystems
Communication ibd. This tutorial doesn’t explain how to build the Whitebox ICD Table, but
you can find this information in the latest documentation of the modeling tool.
These allocations enable you to update the Reach Desired Temperature diagram with item flows by
synchronizing them from the relevant ibd. This time, we will synchronize from the VCCU Conceptual
Subsystems Communication diagram.
2. Click the Vertical Swimlanes button on the activity diagram palette and then click an empty space on
that diagram pane. Swimlanes with blank headers are created on the diagram.
3. Right-click any of the swimlanes and select Insert Swimlane > Vertical to the Left. A new swimlane
with a blank header is created.
4. Repeat step 3 to create another swimlane.
5. In the Model Browser, select the VCCU block. For this, use the quick find capability:
9. Drag the initial node as well as the Read Desired Temperature and Send Data to Computing Unit actions
to the :Human-Machine Interacting swimlane.
10. Drag the Get Desired Temperature, Get Ambient Temperature, Process Data, Initiate Cooling, and Initiate
Heating actions, as well as decision, merge, and activity final nodes to the :Processing swimlane.
11. Drag one of the Draw Air Out from Cabin actions as well as the Cool Down Temperature to
Desired and Blow Cooled Air Back to Cabin actions to the :Cooling swimlane.
Once all the actions are allocated, it's time to specify item flows among them. Item flows that cross the
swimlane boundary can be easily synchronized from the appropriate ibd (in this case the VCCU Conceptual
Subsystems Communication diagram). Let's start from the item flow between the Send Data to Computing
Unit and Get Desired Temperature actions. The former is allocated to the :Human-Machine Interacting part
property and the latter is allocated to the :Processing part property. If you look at the VCCU Conceptual
Subsystems Communication diagram, you can see that the Desired Temperature signal is flowing between
those part properties. Therefore, you can conclude that the same signal is flowing between the actions
they allocate. The modeling tool helps you specify the item flows without switching between diagrams,
as outlined below.
The list always includes the item flows that are possible between two actions. These item
flows are taken from the relevant ibd.
4. Close the dialog. As a result, the item flow conveying Desired Temperature signal displays in the
diagram.
Next you can specify the item flows within the same swimlane, starting from the item flow between the
Read Desired Temperature and Send Data to Computing Unit actions.
To specify the item flow conveying the Desired Temperature signal between the Read Desired Temperature
and Send Data to Computing Unit actions
2. Click the New Item Flow button on its smart manipulator toolbar.
3. In the open dialog, make sure that the Desired Temperature signal is selected as the conveyed item and
click Finish (see the following figure). As a result, the Desired Temperature signal becomes conveyed by
the item flow between the relevant actions.
Although more detailed than the use case scenario (see Chapter Use Cases), this one is still a high-level
scenario and may require decomposition as well. Further structural decomposition stimulated by the
functional decomposition is performed in parallel. The functional and structural breakdown may have as
many iterations as you need to understand the problem domain.
• System functions and its conceptual subsystems, with or without quantifiable characteristics of the
SoI, refine stakeholder needs. Therefore, once you have finished it, you can establish the
traceability relationships to stakeholder needs (see Chapter Traceability to Stakeholder Needs).
• You might also need to specify quantifiable characteristics for one or more conceptual subsystems,
which would be more specific than those defined for the whole SoI (see Chapter Measures of
Effectiveness). In that case, you should move to the MoEs for Subsystems cell.
In this cell, you should specify the MoEs for one or more conceptual subsystems (aka functional blocks) of
the SoI to make further refinements of non-functional stakeholder needs. This cell is optional, as you
might not need to specify MoEs in addition to those defined for the entire SoI (see Chapter Measures of
Effectiveness).
Who is responsible?
MoEs for conceptual subsystems can be identified by the Systems Analyst or Systems Engineer.
How to model?
To capture MoEs for conceptual subsystems in the modeling tool, you can utilize the infrastructure of the
SysML bdd – the same way you used it for capturing MoEs of the SoI in the Measures of
Effectiveness cell. Just like in that cell, measures of effectiveness for a conceptual subsystem can be
captured in the model as value properties of that subsystem, with the «moe» stereotype applied.
Tutorial
• Step 1. Organizing the model for MoEs for subsystems
• Step 2. Capturing MoEs for subsystems
a. Right-click the 4 MoEs for Subsystems package and select Create Diagram.
b. In the search box, type bdd (the acronym of the SysML block definition diagram), and then
double-press Enter. The diagram is created.
Note that the diagram is named after the package where is it stored. This name perfectly
suits the diagram, too. You need only remove the sequence number from its name.
2. Display the MoEs Holder block on the newly created diagram. For this:
3. In the same way, display the Cooling block on the diagram as well.
4. Select the Cooling block and click the Generalization button on its smart manipulator toolbar.
5. Select the MoEs Holder block. As a result, the Cooling block inherits all the properties of the MoEs
Holder block.
6. Display inherited properties on the shape of the Cooling block. For this:
After you capture the MoEs for all conceptual subsystems of the Vehicle Climate Control Unit, your
diagram should look similar to the one below.
As you can see, the values compartments are cut to display the full length of value property rows.
For this, do the following:
1. Select all the blocks that capture conceptual subsystems of the Vehicle Climate Control Unit.
Press Shift for multiple selection.
2. Right-click the selection and choose Symbol Properties.
3. In the open dialog, find the Shrinkable Attributes and Operations Compartment property and
set its value to true.
In order to have a complete problem domain model, you need to establish traceability relationships
between the elements that capture stakeholder needs and the elements that capture the white-box
functions, conceptual subsystems, conceptual interfaces, and non-functional characteristics of the SoI.
Since the latter are more concrete than stakeholder needs, we recommend establishing refine
relationships. These relationships should point from the elements of the lowest level of detail, such as
actions that capture leaf functions of the functional decomposition model. When you're done with
traceability relationships here, every item of the stakeholder needs must be refined by one or more
elements of the other SysML types. The opposite means that not all stakeholder needs are considered in
the problem domain model, which may lead to incorrect system requirements specification (see Chapter
System Requirements), resulting in developing the wrong system.
Who is responsible?
How to model?
Neither of the SysML diagrams is suitable for creating a mass of cross-cutting relationships, such as refine.
For this, a matrix or a map is more suitable. The modeling tool offers a wide variety of predefined matrices
for specifying cross-cutting relationships. To capture refine relationships, a Refine Requirement Matrix can
be used.
Remember, stakeholder needs must be refined by the problem domain elements from the lowest level of
detail. Therefore, the column elements must be taken from the package that contains the white-box
analysis results.
a. In the Model Browser, select any call behavior action, such as the one typed by the Initialize
Cooling activity (which appears under the Reach Desired Temperature activity).
b. Drag the selection onto the Row Element Type box in the Criteria area above the matrix contents.
The rows of the matrix are set to display the elements of the call behavior action type.
c. In the Model Browser, select any part property; for example, the one typed by the Cooling block.
d. Hold down the Ctrl key and drag the selection onto the Row Element Type box in the Criteria area
above the matrix contents. The rows of the matrix are set to display the elements of the part
property type as well.
e. Repeat steps c and d to enable the rows of the matrix to display the proxy ports and value
properties with the «moe» stereotype.
If the matrix displays interface blocks, you can easily get rid of them by modifying its display
settings. For this, click the ... button next to the Row Element Type box and in the open dialog, click
to clear the Include Subtypes check box. Don't forget to refresh the matrix.
• Double-click the cell at the intersection of the row that displays the Cool Down Temperature to
Desired action and the column that displays the SN-1.1.6 Desired Temperature requirement. The
derivation relationship is created between the appropriate items and displayed in the cell.
To save space, the contents of the 2 Conceptual Subsystems Communication package were
hidden in the following figure.
The complete problem domain analysis model, including the stakeholder needs for the SoI, the expected
functions and conceptual structure of the SoI, either with or without the MoEs, can be considered as initial
system requirements specification in the model-based form. If the system requirements specification is
required in textual form (which is not a rare case), the problem domain analysis model can be transformed
(either manually or automatically by utilizing the transformation algorithms) into the SysML requirements
model and provided to system architects as input for developing the logical architecture of the SoI in the
solution domain. This is described in Chapter Solution domain.
As the same problem definition can have several solutions, a trade-off analysis can be performed to choose
the optimal solution for implementing the system (see the following figure).
It should be noted that a problem domain can be specified by one organization, and a solution domain by
another. Furthermore, diverse solutions can be provided by separate organizations.
As you can see in the following table, creating the solution domain model consists of specifying
requirements, structure, behavior, and parameters of the SoI. Furthermore, the task of building a logical
architecture usually includes more than one iteration, going down from the system-level to the
subsystem-level, from the subsystem-level to the component-level architecture and even deeper, if there is
a need. The precision of the system architecture model depends on the number of iterations.
The logical architecture of the SoI can be specified in a single model and even in the same model with the
problem domain definition. However, in most cases, the scope and complexity of the solution domain
model exceeds the scope and complexity of the problem domain definition, especially when
it includes more than one solution. Specifying the solution domain in two or more separate models helps
to manage the information complexity. Moreover, such model partitioning enables a more granular model
ownership, change analysis and control, access control, concurrent modifications, and model reuse.
The following material describes a method of deploying the solution domain across multiple models.
As stated before, more than one solution can be provided for the same problem. To explain our approach,
we introduce the case of three solution domain models: Solution Domain 1, Solution Domain 2, and Solution
Domain 3. Though the contents of the Solution Domain 1 and Solution Domain 2 are suppressed, you should
imagine them similar to the contents of the Solution Domain 3. The Logical System Architecture (LSA) model
is the core of each solution domain. Based on the results of the problem domain analysis, it defines the
logical subsystems of the SoI in a single-level hierarchy. As you can see in the following figure, there are
three logical subsystems in this case: Subsystem 1, Subsystem 2, and Subsystem 3. It's important to note
that each subsystem is considered a black box in the LSA model, which also defines logical interfaces for
each subsystem to determine how they shall operate with one another and integrate into the whole
according to system requirements. Interfaces are not included in the figure below, to avoid clutter. The
owner of the LSA model is the systems architect, who has “a big picture view” of the SoI. In other words,
the systems architect is like the conductor of an orchestra: he/she ensures everyone is playing the same
melody at the same time.
Definition of logical subsystems in the LSA model helps to identify work packages and appoint them to
separate engineering teams. Every team develops one or more logical architectures for the appointed
subsystem. It may happen that they work in parallel. As seen in the following figure, each of the three
subsystems has several solutions. Logical Subsystem X Architecture 1, where X stands for 1, 2, or 3, is visible
on the top and the others are hidden underneath. The generalization relationship (solid line with hollow,
triangular arrowhead) between the Subsystem 1 and Subsystem 1 Architecture 1 blocks means that the
engineering team working on the Logical Subsystem 1 Architecture 1 model knows (or, in terms of SysML,
inherits) the design constraints (such as logical interfaces) of the logical subsystem defined in
the LSA model, and must follow them.
Other generalizations convey appropriate information. Architectures of different logical subsystems and
even different architectures of the same logical subsystem may include a diverse number of components.
A solution domain model of a logical subsystem defines the requirements, structure, behavior, and
parameters of that logical subsystem.
After engineering teams finish with the logical architectures of all subsystems defined in the LSA model,
the systems architect can integrate them into a single model. He/she picks up the preferred one of each
logical subsystem and builds the integrated logical architecture of the whole system. Note that more than
one solution can be proposed. As you can see in the following figure, we call them System Configuration
1, System Configuration 2, etc. Just like the logical architecture of every subsystem, the integrated logical
architecture of the whole SoI defines the structure, behavior, and parameters, and must meet system
requirements specification.
Having the full model of the SoI, the systems architect can perform a trade-off analysis and pick up the
optimal system configuration; having optimal system configurations of several solution domains, the
systems architect can pick up one optimal solution above all. This is illustrated by the Trade Off analysis in
the following figure.
It commonly happens that subsystem requirements are not adequate to build the logical architecture of
the subsystem, especially when it is developed by a supplier (contractor), as the Original Equipment
Manufacturer (OEM, contracting authority) usually is not willing to share the problem domain model.
Thus, the supplier may decide to perform the problem domain analysis of that logical subsystem
beforehand. The figure below illustrates re-applying the MagicGrid framework from scratch, at the logical
subsystem level, where the logical subsystem is considered the SoI.
As mentioned before, the logical architecture of the SoI can be stored in a separate model, apart from the
problem domain definition. The highlighted area in the following figure shows exactly which part of the
solution domain we are talking about.
As you may conclude looking at the design layout of the MagicGrid framework (see the highlighted area in
the following figure), the system-level solution domain model specifies the system requirements,
structure, behavior, and parameters. Additionally, every SysML element you create in the LSA model must
satisfy at least one system requirement. Otherwise, there is no motivation for having it in the LSA model.
Therefore, you have to start and end the system-level solution domain model with system requirements:
first specify them and, when you have the entire LSA model, establish traceability relationships between
them and logical system architecture elements.
To specify a logical system architecture, you first need to have the system requirements specification in
order to follow it. As you may remember, the results of the problem domain analysis from both black- and
white-box perspectives can be considered as initial system requirements specifications presented in
the model-based form. The main task of this cell is to manually transform the problem domain analysis
model into the SysML requirements model, which enables you to present the system requirements
specification in a textual form.
After the transformation, the following traceability relationships must be established to cross the
boundary between the solution and problem domain models:
• From system requirements to stakeholder needs – to assert which system requirements are derived
from which stakeholder needs
• From system requirements to the rest of the problem domain model – to assert which elements are
refined by which system requirement
System requirements specification can be constantly updated while working on the logical architecture of
the SoI. Moreover, requirements for the logical architecture of subsystems, components, and even more
precise items are derived from the system requirements. This is described in Chapter Subsystem
Requirements.
Unlike stakeholder needs, system requirements are verifiable: after you finish with the LSA model, satisfy
relationships must be established from the elements capturing the logical system architecture to the
system requirements in order to assert which of the former fulfills which of the latter. This is described in
Chapter Traceability to System Requirements.
System requirements specification must be produced by the Systems Analyst or Systems Engineer who
has performed the problem domain analysis.
How to model?
In the modeling tool, an item of system requirements specification can be stored as the SysML
requirement, which has a unique identification, name, and textual specification. As opposed to the textual
specifications of stakeholder needs, system requirements must be formal and written down following
certain guidelines. For example, write in short and clear sentences only, avoid conditional keywords (such
as if, except, as well), use the shall keyword, and include tables. For more information on how to write good
textual requirements, refer to the INCOSE Systems Engineering Handbook.
System requirements can be organized into one or more hierarchy levels. For this, use the containment
relationships among them. The SysML requirement referring to the system requirements specification
must be at the top of the hierarchy. It may have no text.
The SysML requirement table or diagram can help to visualize the hierarchy of system requirements (see
the following figure). The table or diagram can also be included in the requirements report.
Each system requirement must be derived from a certain item of stakeholder needs and/or refine one or
more elements from the problem domain model. To assert a derivation, you should establish the
«deriveReqt» relationship pointing from the system requirement to the appropriate item of stakeholder
needs (the following figure shows these relationships displayed in the matrix). To assert a refinement, the
«refine» relationship pointing from the system requirement to some part property, call behavior action, or
MoE defined in the problem domain model, should be established.
Tutorial
• Step 1. Creating and organizing a model for system requirements
• Step 2. Creating a diagram for system requirements
• Step 3. Specifying system requirements
• Step 4. Establishing traceability to stakeholder needs
• Step 5. Establishing traceability to the rest of the problem domain model
However, in real-world projects it is quite common to keep the solution domain model separated from the
problem domain model. Following this practice, we recommend specifying the system requirements and
the logical architecture of the Vehicle Climate Control System (VCCS) in another model. The contents of the
problem domain model should be available in that model, because the result of the problem domain
analysis is considered as an initial system requirements specification that should be transformed from the
For more information on this topic and the topics mentioned in steps 2 and 3, refer to
the latest documentation of your modeling tool.
Names in grey indicate that elements cannot be modified. This is because the problem domain
model is used in the solution domain model as read-only.
4. Right-click the Model package (this is the default name of the root package) and select Create
Element.
5. In the search box, type pa (the first two letters of the element type Package) and press Enter.
6. Type 2 Solution Domain to specify the name of the new package and press Enter.
7. Right-click the 2 Solution Domain package and select Create Element.
8. Repeat step 5.
9. Type 1 System Requirements to specify the name of the new package and press Enter.
Note that the diagram is named after the package where it is stored. This name works for the
diagram, too. You may only remove the sequence number from its name.
# Name Text
1 Setting Desired Temperature The user shall be able to specify the temperature he/she desires in the cabin.
2 Human-Machine The system shall be able to accept data and commands from the user.
Interactions
3 Getting Ambient The system shall take the ambient temperature from the vehicle temperature
Temperature sensor.
4 Cabin Air The system shall be able to draw air out of the cabin and blow comfortable air
back.
5 Heating The system shall be able to heat the air, if the user wishes to increase the
temperature in the cabin.
6 Cooling The system shall be able to cool the air, if the user desires to decrease the
temperature in the cabin.
7 Central Processing The system shall "decide" whether to cool or to heat the air in the cabin. For
this, it shall take the ambient temperature and compare it to the desired
temperature set by the user.
8 Output Information Display The system status and ambient temperature in the cabin shall be always
displayed in some information output device.
9 Max Energy Consumption The system shall consume maximum 3.518 kWh.
After you’re done, the contents of the System Requirements diagram should look very similar to the one in
the following figure.
In addition, you need a grouping requirement to represent the entire requirements specification. The
easiest way of creating a grouping requirement is described in step 4 of Chapter Stakeholder
Needs tutorial. Follow the procedure to create the SRS for VCCS grouping requirement.
In order to distinguish system requirements from stakeholder needs, subsystem and component
requirements, and detailed requirements for the system implementation, we recommend adding prefixes
to their numbers. Follow the procedure described in step 5 of Chapter Stakeholder Needs tutorial to add
the prefix SR- to your system requirements. Subsequently, these system requirements can be refactored to
more specific ones. For example, Setting Desired Temperature can become an interface requirement and Max
Energy Consumption a physical requirement. For this, follow the procedure described in step 6 of
Chapter Stakeholder Needs tutorial. After you finish numbering and categorization, the contents of
your System Requirements diagram should look very similar to the one in the following figure.
In this case, you need to assert what system requirements (more concrete) are derived from what
stakeholder needs (less concrete), that is, establish derivation relationships between them. Therefore, we
recommend utilizing the infrastructure of the Derive Requirement Matrix, one of the predefined matrices
in the modeling tool. As opposed to a common matrix, it has certain criteria predefined to speed up
building the view.
Just like in the problem domain model, traceability views and relationships can be stored in a separate
package. As you already know how to create packages, we assume that you do this on your own. For
keeping your model well-organized according to the MagicGrid framework, that package should always be
the last sub-package of the 2 Solution Domain package. Therefore, its name must begin with number 5, for
example, 5 Traceability.
1. In the Model Browser, right-click the 5 Traceability package and select Create Diagram.
2. In the search box, type drm (the acronym for the predefined Derive Requirement Matrix), and press
Enter.
If you don’t see any results, click the Expert button below the search results list. The list of
available diagrams expands in the Expert mode.
3. Type System Requirements to Stakeholder Needs to specify the name of the new matrix and press Enter
again.
4. In the Model Browser, select the SR-1 SRS for VCCS requirement and drag it onto the Row Scope box in
the Criteria area above the matrix contents. The SR-1 SRS for VCCS requirement becomes the scope of
the matrix rows.
The following figure displays the Criteria area of the matrix, with highlights on step 4, 5, and 6 related
criteria.
Now you’re ready to establish derivation relationships. Let’s create one between SR-1.1 Setting Desired
Temperature and SN-1.6 Desired Temperature to convey that SR-1.1 Setting Desired Temperature is derived
from SN-1.6 Desired Temperature or, in other words, that this system requirement is created because of that
stakeholder need.
• Double-click the cell at the intersection of the row that displays SR-1.1 Setting Desired
Temperature and the column that displays SN-1.6 Desired Temperature. The derivation relationship is
created between the appropriate items and displayed in the cell.
After all derivation relationships are established, your System Requirements to Stakeholder Needs
matrix should resemble the one in the following figure. You may remember that every system requirement
must be derived from one or more stakeholder needs. Otherwise, the system requirements specification
must be revised and updated. Some stakeholder needs may be left uncovered, if it was decided not to
address them in the system requirements specification.
Afterwards, a Requirement Derivation Map can be created, with blue arrows representing the relationships
between requirements from different domains.
In this case, you need to assert which problem domain elements are refined by which system
requirements; that is, establish refine relationships between them. Therefore, we recommend utilizing the
infrastructure of the Refine Requirement Matrix, one of the predefined matrices in the modeling tool. As
opposed to a common matrix, it has certain criteria predefined to speed up building the view.
This matrix and appropriate relationships can be stored in the 5 Traceability package you created in the
previous step.
1. In the Model Browser, right-click the 5 Traceability package and select Create Diagram.
2. In the search box, type rrm, the acronym for the predefined Refine Requirement Matrix, and press
Enter.
If you don’t see any results in the diagram types list, click the Expert button below it. The list
of available diagrams expands in the Expert mode.
3. Type System Requirements to Problem Domain to specify the name of the new matrix and press Enter
again.
4. On the matrix toolbar, click the Change Axes button to swap rows of the matrix with columns.
Requirement becomes the type of the matrix rows.
5. In the Model Browser, select the SR-1 SRS for VCCS requirement (you might need to expand
the 1 System Requirements package first) and drag it onto the Row Scope box in the Criteria area above
the matrix contents. The SR-1 SRS for VCCS requirement becomes the scope of the matrix rows.
6. Select column element types:
a. In the Model Browser, select any call behavior action; for example, the one typed by the Initialize
Cooling activity (it appears under the Reach Desired Temperature activity which can be found
within the 3 Functional Analysis package in the problem domain analysis model).
b. Drag the selection onto the Column Element Type box in the Criteria area above the matrix
contents. The columns of the matrix are set to display the elements of the call behavior action
type.
c. In the Model Browser, select any part property, such as the one typed by the Cooling block. It
appears under the VCCU block, which can be found within the 2 Logical Architecture package in the
problem domain analysis model.
d. Hold down the Ctrl key and drag the selection onto the Column Element Type box in
the Criteria area above the matrix contents. The columns of the matrix are set to display the
elements of the part property type as well.
e. Repeat steps c and d to enable the columns of the matrix to display the proxy ports and value
properties with the «moe» stereotype.
a. In the Model Browser, select the 2 White Box package in the problem domain analysis model.
b. Drag the selection onto the Column Scope box in the Criteria area above the matrix contents. The
selected package becomes the scope of the matrix columns.
Now you’re ready to establish refine relationships. Let’s create one between the SR-1.1 Setting Desired
Temperature requirement and the p1 proxy port of the Human-Machine Interacting block to assert that the
former refines the latter, or, in other words, that this system requirement is created to refine that proxy
port.
• Double-click the cell at the intersection of the row that displays SR-1.1 Setting Desired
Temperature and the column that displays the p1 proxy port . The refine relationship is created
between appropriate items and displayed in the cell.
After all refine relationships are specified, your System Requirements to Problem Domain matrix should
resemble the one in the following figure. Keep in mind that every system requirement must refine one or
more elements captured in the problem domain analysis model. Otherwise, the system requirements
specification must be revised and updated. Some elements can be left uncovered, if it was decided not to
address them in system requirements specification (such as MoEs for the sound level and total weight).
• When you have the system requirements specification captured in the SysML requirements model,
you can start building the logical architecture of the SoI . This means you can move to the System
Structure cell.
• System requirements specification can be updated any time while building the logical architecture
of the SoI. The updates should stop only after switching to the subsystem-level solution domain
model.
After the system requirements specification is completed, you can start building the logical architecture of
the SoI. Usually it starts with capturing the logical subsystems of the SoI. The LSA model also specifies
interfaces, to determine how these subsystems shall inter-operate with one another and integrate into the
whole. Subsystems of the solution domain may differ from the subsystems identified in the problem
domain. This happens quite often, as the problem domain definition is not as precise as the solution
architecture. For the purpose of tracing from the subsystems of the solution architecture to the
subsystems of the conceptual architecture in the problem domain model, cross-cutting relationships can
be established.
Defining the logical subsystems serves for the purpose of establishing the work-breakdown structure
(WBS) in the systems engineering project: each logical subsystem identifies a single work package, which
is immediately appointed to some engineering team. That team develops one or more logical architectures
for the appointed subsystem. Separate teams usually work in parallel to develop logical architectures of
different subsystems. Modeling the logical architecture of a single subsystem is described in Chapter
Building the logical architecture of subsystems.
Who is responsible?
System structure in the LSA model can be captured by the Systems Architect or Systems Engineer. He/she
must be the head of the whole systems engineering project, the one, who has “a big picture view” of the
SoI and is responsible for the smooth integration of the subsystems and their components into the whole.
How to model?
As you can remember, the LSA captures the system of interest, its logical subsystems at one level down,
and the interfaces to determine how these subsystems inter-operate, that is, what data, matter, or energy
they exchange. The LSA model can be created and displayed in a SysML bdd. Subsystems can be captured
as blocks, and interfaces as proxy ports typed by appropriate interface blocks.
In the following figure, you can see a sample LSA model of the Vehicle Climate Control System (VCCS). It
displays the blocks that capture logical subsystems of the VCCS, interface blocks that own flow properties
which capture inputs and outputs for both external and internal communications as well as various
exchange items which type relevant flow properties.
Tutorial
• Step 1. Organizing the model for the LSA
• Step 2. Creating a bdd for capturing the LSA
• Step 3. Capturing logical subsystems
• Step 4. Establishing traceability to the problem domain model
• Step 5. Capturing logical interfaces
1. Open the solution domain model (the VehicleCCS Solution.mdzip file) you created in Chapter System
Requirements, if not opened yet.
2. Right-click the 2 Solution Domain package and select Create Element.
3. In the search box, type pa (the first two letters of the element type Package), and press Enter.
4. Type 2 System Structure to specify the name of the new package and press Enter.
For the purpose of keeping the inner structure of the 2 System Structure package well organized, you need
to create a few more packages. These are:
• 1 Logical Interfaces
• 2 Exchange Items
• 3 Logical Subsystems
After you create them (on your own by following the previous procedure), the Model Browser of your
solution domain model should look the same as the following figure.
Logical subsystems can be captured as blocks in the bdd you created in the previous step. As already
mentioned, the LSA model always defines logical subsystems at one level down, and the logical
architecture of each subsystem should be subsequently produced by separate engineering teams in
isolated models (see Chapter Subsystem Structure).
Note that the names of the logical subsystems correspond to the names of the conceptual subsystems in
the problem domain model, such as Cooling System to Cooling, or Heating System to Heating. However,
these concepts are not the same; therefore, be sure you haven't selected the block from the problem
domain model instead of creating a new one in the solution domain model, when specifying the logical
subsystems of the VCCS. To prevent this mistake, you can narrow down the name auto-completion and
type selection scope beforehand. The following figure displays the auto-completion before (on the left)
and after (on the right), narrowing the scope to the solution domain model only.
2. In the Model Browser, select the 2 Solution Domain and 2 System Structure packages (the latter is a
sub-package of the former) and drag them to the pane of the newly created diagram.
3. Select the shape of the 2 System Structure package and click the Package Import button on its
smart manipulator toolbar.
4. Select the shape of the 2 Solution Domain package. The package import relationship is created
between the packages.
From now on, when you model in the 2 System Structure package, elements suggested as names and types
will be taken from the 2 Solution Domain package only, while elements stored in the 1 Problem Domain
package (from the problem domain model) will be left aside. This means it won't be suggested that you
choose from conceptual subsystems and interfaces as well as exchange items captured in the problem
domain model.
If you still see those elements, click the Filter Options button below the list and then click to select the
Filter By Package Imports check box (see the following figure). For more information about the package
import feature, refer to the latest documentation of the modeling tool.
a. Click the Block button on the diagram palette and then click on the diagram pane.
b. Type VCCS to name the block and press Enter.
a. Click the Directed Composition button on the smart manipulator toolbar of the VCCS block and
then click an empty place on the diagram pane.
b. Type HMI System to name the block and press Enter.
c. Repeat steps 3.a and 3.b to capture other subsystems from the list above.
Note that the part property names (displayed at the arrow end of the relationship) differ from
the default. They can be changed manually. For this, you need to select the part property you
want to rename on the diagram and then click it again to enter the name edit mode (see the
following figure). You are able to modify it immediately.
5. In the Model Browser, select all blocks of the subsystems and drag them to the 3 Logical Subsystems
package you created in step 1 of this cell tutorial. The blocks are moved to the 3 Logical Subsystems
package.
You already know that the most effective view for establishing traceability relationships is a matrix. Let's
create one.
To create the matrix for traceability relationships to the problem domain model
1. In the Model Browser, right-click the 5 Traceability package, a subpackage of the 2 Solution Domain
package, and select Create Diagram.
2. In the search box, type dm (the acronym for the Dependency Matrix), and press Enter.
If you don’t see any results, click the Expert button below the search results list. The list of
available diagrams expands in the Expert mode.
3. Type LSA to Problem Domain to specify the name of the new matrix and press Enter again.
4. Specify the row and column element type:
a. In the Model Browser, select any block, such as the VCCS block.
b. Drag it onto the Row Element Type box in the Criteria area above the matrix contents. Rows and
columns of the matrix are both set to display the elements of the block type (see the figure
below).
c. Click the button next to the Column Element Type box.
d. In the open dialog, click to clear the Include Subtypes check-box. Otherwise, the columns display
a few interface blocks, which you don't need here.
e. Click OK to close the dialog.
a. In the Model Browser, select the VCCU block (for this, you might need to expand the contents of
the following read-only packages: 1 Problem Domain > 2 White Box > 2 Conceptual Subsystems
Communication).
b. Drag the selection onto the Column Scope box in the Criteria area above the matrix contents. The
selected block becomes the scope of the matrix columns.
c. In the Model Browser, select the 2 Conceptual Subsystems package, which appears under the same
package with the VCCU block.
8. Click the Direction box and select Row to Column, as you need to establish the abstraction
relationships pointing from logical subsystem (row elements), to conceptual subsystems (column
elements).
9. Click the Refresh hyperlink in the notification box below the Criteria area. The contents of the matrix
are updated. All the cells are empty at the moment.
The following figure displays the Criteria area of the matrix with highlights on step 4, 5, 6, 7, and 8 related
criteria.
Now you’re ready to specify abstraction relationships. Double-click the cell at the intersection of relevant
row and column (for example, between the row that represents the Cooling System block and the column
that represents the Cooling block).
These statements indicate the need for the logical interfaces that you see in the following figure. These
interfaces are more precise than conceptual interfaces determined in the problem domain analysis model:
the DesiredTmpSet and AmbientTmpRead signals have properties for holding specific values of Integer type.
These properties can even have default values, such as DesiredTmp=22.
To capture the interface block for providing the desired temperature and relate it to the VCCS block
a. Remove the out part of the flow property direction indicator to specify that the direction of the
flow property is in.
b. Type dts to specify the flow property name. Don't press Enter!
c. Type :DesiredTmpSet and press Enter. The DesiredTmpSet signal is created in the model directly
under the UserDataInput interface block and immediately set as its only flow property type.
a. Make sure the UserDataInput interface block is selected on the diagram and press Alt+B. The
element is selected in the Model Browser.
b. Click near the UserDataInput interface block to expand its contents.
c. Select the DesiredTmpSet signal and drag it to the 3 Exchange Items package.
d. Select the UserDataInput interface block again and drag it to the 1 Logical Interfaces package, a
sub-package of the 2 System Structure package.
7. Select the UserDataInput interface block on the diagram and drag it onto the VCCS block. As a result, a
new proxy port, typed by the UserDataInput interface block, is created for the VCCS block. Note that it
is decorated with an arrow indicating that this port is for inputs to the system of interest.
a. In the Model Browser, right-click the 3 Exchange Items package and select Create Diagram.
b. In the search box, type bdd (the acronym for SysML block definition diagram), and then press
Enter. The diagram is created.
c. Remove the sequence number from the diagram name press Enter again.
a. In the Model Browser, select that signal and drag it to the Exchange Items diagram pane.
b. Click the Create Property button on the signal shape.
c. Type DesiredTmp to name the new property.
d. Type :Int press Ctrl + Spacebar to open the list of possible types. Once you see the Integer value
type (the pink one) in the search results list, select it.
Following the previous procedure, capture another two interface blocks (with all the related information)
and bind them to the VCCS block. Once you're done, the Logical Architecture of VCCS diagram in your model
should look very similar to the first image of this tutorial step.
The system requirements specification also reveals that the VCCS shall be able to provide the following to
the outside:
• Comfortable (cooled or heated) air back to the cabin
• Output information about the VCCS status for the user
These statements indicate that the VCCS needs a few more interfaces. You can see them in the following
figure. We assume that you update the model on your own.
Let's start from specifying logical interfaces for external communication. As already mentioned, you don't
need to create new interface blocks: simply drag the selected interface block onto the block that captures
the relevant logical subsystem (the same as you did for the VCCS block). For example, you can drag the
InsideAirInlet interface block onto the Cooling System block. As a result, a proxy port typed by the
InsideAirInlet interface block is created for the Cooling System block.
After you specify all the interfaces for external communication, the Logical Architecture of the VCCS bdd in
your model should look very similar to the one in the following figure.
It is obvious that the CP System shall be able to send commands to other subsystems. These might include
Start, Stop, Idle, Cool, Heat, etc. They can be identified later, when modeling the logical architecture of
that subsystem. This requires creating a new interface block and a few signals (you can see them
highlighted in the following figure). Also, new subsystem requirement must added, but let's leave it for
modeling in other cells.
The next step is to specify that the CP System block is able to send the Command signal or any of its sub-
types out, and the Cooling System, Heating System, and HMI System blocks are able to accept them. For
this, you should create a proxy port for each block that captures the logical subsystem and then make the
proxy ports of the Cooling System, Heating System, and HMI System blocks conjugated. As a result, names
of the interface block typing these proxy ports appear decorated with a tilde (“~”), and its flow property
directions become reversed for these proxy ports, which conveys that the Cooling System, Heating System,
and HMI System blocks are able to accept the Command signal or any of its sub-types.
It's important to note here that even though this way of specifying compatible proxy ports is easier,
it is not always best. It is more common in real-world projects to define a couple of compatible
interface blocks instead of defining a single interface block and then making one of the proxy ports
conjugated.
There are two more interfaces, the InternalResponse and InternalDataTransferer, that can be specified for
internal communication. You can see them in the following figure. We assume that you capture all the
highlighted SysML elements in your model.
• Having logical subsystems and knowing how they will communicate, you can start working on their
logical architecture models. Therefore, you could move to Chapter Building the logical architecture
of subsystems.
• However, you still have two cells left for creating the logical system architecture model. Therefore,
you should proceed to the System Behavior and System Parameters cells.
The LSA is not only about the system structure; the systems architect can capture the behavior of the
whole SoI in the LSA model, too. However, this is not a common practice. Since the precise logical
architecture of the SoI is not yet defined, the system behavior model appears too abstract and cannot say
much about the system behavior. Moreover, it may conflict with the system behavior in the integrated
model of the selected system configuration (see Chapter Building system configuration model). That's
why this cell is often skipped when building the LSA of the SoI in real-world projects.
Unlike that in the LSA model, the system behavior in the integrated model of the selected system
configuration is crucially important. Since the integrated model includes the architectures of all logical
subsystems of the SoI, it can be used to analyze the integrated behavior of the entire system and perform
the system requirements verification.
Who is responsible?
System behavior in the LSA model can be captured by the Systems Architect or Systems Engineer. He/she
must be the head of the whole systems engineering project, the one who has “a big picture view” of the
SoI and is responsible for the smooth integration of the subsystems and their components into the whole.
How to model?
The system behavior in the LSA model can be captured by utilizing the infrastructure of the SysML state
machine and activity or sequence diagrams in combination. The SysML state machine allows capturing
states of the SoI and transitions between them in response to event occurrences over time. The activity or
sequence diagrams should be used to specify the entry, do, and exit behaviors of these states or transition
effects.
Though the diagram in the following figure captures the behavior of the Cooling System, which is one of
subsystems, the behavior of the SoI in the LSA model looks very much like this.
Tutorial
To follow the common practice, we skip this cell in the LSA model and get back to it in the system
configuration model (see Chapter System Configuration Behavior).
What’s next?
You can go to this cell as soon as the system structure is captured in the model, even as abstract as in the
LSA model.
System parameters capture quantitative characteristics of the system of interest, that you can measure.
They are used to calculate MoEs identified during the problem domain analysis (see Chapter Measures of
Effectiveness). MoEs captured in the solution domain model satisfy non-functional quantitative system
requirements.
Mathematical expressions for MoEs derivation from system parameters should also be specified in this
cell. Knowing how to calculate MoEs enables early system requirements verification. Using the capabilities
of the modeling tool, the model can be executed to calculate these values and show whether quantitative
requirements are satisfied or not.
It's important to note here that not all MoEs in the solution domain must be based on the MoEs in the
problem domain model. Some of them can be identified only when building the logical architecture of the
SoI.
Who is responsible?
System parameters in the LSA model can be captured by the Systems Architect or Systems Engineer. He/
she must be the head of the whole systems engineering project, the one, who has “a big picture view” of
the SoI and is responsible for the smooth integration of the subsystems and their components into the
whole.
How to model?
As you should already know, measures of effectiveness can be captured in the model as value properties
with the «moe» stereotype applied. These value properties must belong to the block, which represents the
system of interest. You must also know that measures of effectiveness can be inherited from the reusable
sets of MoEs, called MoEs holders, instead of specifying them from scratch.
The formula for calculating the MoE can be captured as a constraint expression of some constraint block.
The infrastructure of the SysML block definition diagram can be utilized for capturing MoEs, constraint
expressions, and even required system parameters. The following figure displays the diagram that captures
the totalEnergyConsVCCS measure of effectiveness and the formula for calculating this MoE as the
constraint expression of the Total Energy Consumption constraint block.
The simulation capabilities of the modeling tool allows you to calculate MoEs with given inputs. With the
MoE calculated, you can verify the appropriate non-functional system requirement and show whether it is
satisfied or not. The modeling tool enables you to perform this verification automatically. To get ready for
the automated requirements verification, you need to create a satisfy relationship from the value property,
which captures the MoE, to the appropriate system requirement. The following figure displays an example
of the satisfy relationship between the totalEnergyConsVCCS value property and the Max Energy
Consumption non-functional requirement, which means that the requirement is satisfied when the value of
the totalEnergyConsVCCS value property is not greater than 3.518 kWh. As you can see, the natural
language expression in the requirement text is refined by another constraint expression of the Max Energy
Consumption constraint block with the x <= 3.518 inequality.
Tutorial
1. Open the solution domain model (the VehicleCCS Solution.mdzip file) you created in Chapter System
Requirements, if not opened yet.
2. Right-click the 2 Solution Domain package and select Create Element.
3. In the search box, type pa (the first two letters of the element type Package), and press Enter.
4. Type 4 System Parameters to specify the name of the new package and press Enter.
Even though we don't have the 3 System Behavior package (remember that it's not necessary to
model the system behavior in the LSA model), we skip “3” in package numbering to
correspond to the layout of the MagicGrid framework.
Step 2. Specifying the MoE for capturing the total energy consumption
As you can see in the following figure, the system requirements specification (see Chapter System
Requirements) and the appropriate MoE (see Chapter Measures of Effectiveness) in the problem domain
model determine the specification of the MoE that captures the total energy consumed by the VCCS, in the
solution domain model.
It was already mentioned that MoEs can be specified from scratch or inherited from the MoEs holder. The
following procedure describes inheritance from the MoEs holder. The inherited MoE is redefined to change
its name and type. Redefinition is necessary for automated requirements verification, which is performed
in one of the following steps.
a. Right-click the 4 System Parameters package you created in step 1 of this cell tutorial and
select Create Diagram.
b. In the search box, type bdd (the acronym of the SysML block definition diagram), and then
double-press Enter. The diagram is created.
c. Type System Parameters for Total Energy Consumption to specify the name of the new diagram and
press Enter again.
a. Select the shape of the VCCS block and click the Generalization button on its smart
manipulator toolbar.
b. Select the shape of the MoEs Holder block. The MoEs Holder block becomes the super-type of
the VCCS block, which means that the VCCS block inherits all MoEs from the MoEs Holder block.
d. In the Type cell, immediately type kWh and press Enter. The kWh value type is created in the
model and set as type for the redefined value property.
f. Click Close.
When you're done, the System Parameters for Total Energy Consumption bdd in your model should be
similar to the one below.
Let’s say the total energy consumption of the VCCS equals a sum of energies consumed by all its
subsystems. The constraint expression can be defined as follows:
where:
To capture the method for calculating the total energy consumed by the VCCS
a. Open the System Parameters for Total Energy Consumption diagram, if not opened yet.
b. Click the Constraint Block button on the diagram palette and then click an empty space in that
diagram pane. An unnamed constraint block is created.
c. Type Total Energy Consumption directly on the shape of that element to specify its name and press
Enter.
a. Click the symbol of the empty constraint expression on the Total Energy Consumption constraint
block.
b. Click the selection again. The empty constraint expression switches to the edit mode.
a. Select the shape of the Total Energy Consumption constraint block and click the Parse and Create
Parameters button on its smart manipulator toolbar (see the following figure). Constraint
parameters are automatically extracted from the constraint expression and displayed in
the parameters compartment box on the shape.
i. Double-click the type to select it, type kWh, and press Ctrl + Spacebar.
ii. Select the kWh type from the list below.
iii. Press Enter.
Once you’re finished with the last one, the shape of the Total Energy Consumption constraint block should
look like the one in the following figure.
Remember that it has four input parameters, one each for the energy consumption of a single subsystem
of the VCCS, and requires four subsystem parameters in your model. Appropriate value properties should
be specified for each block that captures one of the subsystems of the VCCS.
1. Open the System Parameters for Total Energy Consumption diagram, if not opened yet.
2. Display the blocks capturing the logical subsystems of the VCCS block:
a. Right-click the VCCS block and select Display > Display Related Elements.
b. In the open dialog, click Outgoing and then click to clear the Abstraction check box.
c. Click OK to close the dialog. As a result, all the blocks representing the subsystems of the VCCS
are displayed on the diagram pane.
3. Create the energyCons value property for the Cooling System block:
a. Select the shape of the Cooling System block, click the Create Element button , and then select
Value Property.
b. Type energyCons:kW and press Ctrl + Spacebar to select the suitable value type.
c. Select the kWh value type from the list below and press Enter.
4. Repeat step 3 to create value properties for the CP System, Heating System, and HMI System blocks.
Bindings between value properties and constraint parameters can be established using binding connectors.
This type of SysML relationship can be created by utilizing the infrastructure of the SysML parametrics
diagram created for the VCCS block. However, creating the SysML parametrics diagram is not enough to
get started. Establishing binding connectors is possible only after the constraint property typed by
the Total Energy Consumption constraint block is created for the VCCS block. Be aware that the same
constraint block can be used in multiple contexts, and binding connectors are context-specific
relationships.
If you cannot see them, you might need to expand the related part properties.
d. Click OK. Selected value properties are displayed on the diagram pane, and the diagram is
selected in the Model Browser with the name edit mode switched on.
e. Type Total Energy Consumption of VCCS to name the diagram and press Enter.
4. Drag the constraint block to the Total Energy Consumption of VCCS diagram. An unnamed constraint
property, typed by the Total Energy Consumption constraint block, is created for the VCCS block.
The Parametric Equation Wizard dialog opens concurrently.
5. Select constraint parameters (on the left side of the dialog) one by one and drag each to the
corresponding value property (on the right side of the dialog):
• You may need to expand the structure on the right side of the dialog to see the value
property you need. Remember that they belong to the subsystem blocks, but not to
the system block directly.
• Once bound, the constraint parameter changes its color from red to grey.
Now you can execute the model, provide input values, and see the result of the calculation. To start the
execution, click the Run button in the toolbar above the Total Energy Consumption of VCCS diagram.
When in the Variables tab of the Simulation panel (by default, it is on the right side of the Simulation
panel), you can specify the input values and see the output value (result of the calculation).
1. Formalize the constraint captured as the natural language phrase in the text of the particular system
requirement.
2. Indicate the value property whose value determines whether or not the system requirement is
satisfied.
In this case, you should formalize the Max Energy Consumption system requirement, which indicates that
“The system shall consume maximum 3.518 kWh." This requires creating another constraint block with a
constraint expression (this time the x <= 3.518 inequality), and making it refine the relevant system
requirement.
a. Right-click the Max Energy Consumption requirement and select Display > Display Related
Elements.
b. In the open dialog, click Outgoing, click to clear the DeriveReqt and Refine check boxes, and then
click to select the Containment check box.
c. Click OK.
i. Click the symbol of the empty constraint expression on the constraint block.
ii. Click the selection again. The empty constraint expression switches to the edit mode.
iii. Type x <= 3.518 and then press Enter.
e. Select the shape of the Max Energy Consumption constraint block and click the Parse and Create
Parameters button on its smart manipulator toolbar. The x constraint parameter is
automatically extracted from the constraint expression and displayed in
the parameters compartment box on the shape.
f. Select the parameters and change their types from the default Real to kWh directly on the shape
of the constraint block:
i. Double-click the type to select it, type kWh, and press Ctrl + Spacebar.
ii. Select the kWh type from the list below it.
iii. Press Enter.
5. Specify the refine relationship between the Max Energy Consumption constraint block and the relevant
system requirement:
a. Select the shape of the constraint block and click the Refine button on its smart manipulator
toolbar.
b. Click the shape of the Max Energy Consumption system requirement. The refine relationship
conveying that the textual system requirement is formalized by the Max Energy
Consumption constraint block is created.
As a result, the word maximum is underlined on the shape of the Max Energy Consumption
system requirement. If you hover the mouse over that text, you can see the inequality operator,
which is automatically parsed from the word maximum.
The x <= 3.518 inequality is stored in the model as the constraint expression of the virtual constraint
block, which can be extracted on demand, as this is not necessary for automated requirements
verification; the virtual constraint expression is enough.
To extract the constraint block from the Max Energy Consumption system requirement
1. Right-click the requirement and select Tools > Extract Constraint Block From Requirement. The
new constraint block is created in the model and automatically related to the Max Energy
Consumption system requirement.
2. Drag the Max Energy Consumption constraint block onto the diagram pane. The shape of the
constraint block and the refine relationship pointing from that constraint block to the Max
Energy Consumption system requirement are displayed on the diagram.
Next, specify that values of the totalEnergyConsVCCS value property can be used to determine whether or
not the Max Energy Consumption system requirement is satisfied. For this, you need to bind the
x parameter of the Max Energy Consumption constraint block to the totalEnergyConsVCCS value property.
This can be done in the Total Energy Consumption of VCCS parametrics diagram.
4. Click OK. The Total Energy Consumption of VCCS parametrics diagram is updated with the new
constraint property for verification of the Max Energy Consumption system requirement.
To create a satisfy relationship from the totalEnergyConsVCCS value property to the Max Energy
Consumption system requirement
3. Click the Satisfy button on the smart manipulator toolbar of that value property.
4. Click the Max Energy Consumption system requirement.
Now, if you hover the mouse over the underlined word maximum on the shape of the Max Energy
Consumption system requirement, you can see the complete condition that must be fulfilled to
satisfy that system requirement.
If you go back to the Total Energy Consumption of VCCS diagram and execute the model again, you should
note that the totalEnergyConsVCCS value property is highlighted in green, indicating that the Max Energy
Consumption system requirement is satisfied. Try to change the input values and see how the highlight
For keeping your model well organized, it is recommended to store the instance specifications and their
slots in a separate package. They can be displayed in a special type of table: the instance table. It provides
a convenient layout for reviewing slot values and recalculating them. Moreover, new instances with
corresponding slots can be created here.
1. In the Variables tab of the Simulation panel, select the root element; that is, the VCCS block.
If you don't see the Create Owner button, click to toggle the Creation Mode button. As a
result, the Create Owner button appears in the dialog.
5. In the Specification of the new package, type 1 Parameter Values to give it a name.
6. Click Close in the Specification of that package.
7. Click OK in the Select Owner dialog. The instance of the VCCS block with slots holding concrete values
of relevant value properties is created.
a. In the Model Browser, right-click the 1 Parameter Values package and select Create Diagram.
b. In the search box, type ins. When you see the instance table selected in the search results, press
Enter. The table is created.
c. Type Total Energy Consumption Values to specify the name of the new table and press Enter again.
2. In the Model Browser, under the same package, select the root instance; that is, the one typed by the
VCCS block.
3. Drag the selected instance to the instance table on the right. As a result:
a. On the toolbar above the instance table, click the Columns button and select Select Columns.
b. In the open dialog, click to select:
When you're done, the instance table in your model should look the same as the one in the following
figure.
Now you can create new rows to display other instances with slots for diverse input and output values.
To create a new instance specification of the VCCS block in the instance table
1. On the toolbar above the instance table, click the Create (Insert) button and then select Create
with Parts (see the following figure). This is necessary because you also need to create slots of value
properties that belong to the parts of the VCCS block, but not to this block directly. A row of the new
instance with all slot values 0 is created.
Note that output values violating the Max Energy Consumption system requirement are
highlighted. If you cannot see the highlights in your model, make sure the
SimulationProfile.mdzip is used in your model. For more information on how to use another
project or profile in your project, refer to the documentation of the modeling tool.
The contents of the instance table can be exported to the MS Excel spreadsheet to share it internally
or externally.
To have a complete LSA model, you need to establish traceability relationships from the elements that
capture the LSA of the SoI to the elements that capture the system requirements. As determined by
SysML, these are satisfy relationships, meaning that the element from the LSA model fulfills one or more
of the system requirements. For example, a satisfy relationship can be established from the part property
typed by the block that captures some logical subsystem to a certain system requirement. In the complete
LSA model, all system requirements are satisfied by one or more elements of the logical system
architecture.
Who is responsible?
Traceability relationships in the LSA model can be established by the Systems Architect or Systems
Engineer. He/she must be the head of the whole systems engineering project, the one, who has “a big
picture view” of the SoI and is responsible for the smooth integration of the subsystems and their
components into the whole.
How to model?
Neither of the SysML diagrams is suitable for creating a mass of cross-cutting relationships, such
as satisfy. For this, a matrix is more suitable. The modeling tool offers a wide variety of predefined
matrices for specifying cross-cutting relationships. To capture satisfy relationships, a Satisfy Requirement
Matrix can be used.
Tutorial
• Step 1. Creating a matrix for capturing satisfy relationships
• Step 2. Capturing satisfy relationships
1. In the Model Browser, right-click the 5 Traceability package (you created it in Chapter System
Requirements) and select Create Diagram.
2. In the search box, type srm, the acronym of the predefined Satisfy Requirement Matrix, and press
Enter.
If you don’t see any results, click the Expert button below the search results list. The list of
available diagrams expands in the Expert mode.
3. Type LSA to System Requirements to specify the name of the new matrix and press Enter again.
4. On the matrix toolbar, click the Change Axes button to swap rows of the matrix with columns.
Requirement becomes the type of the matrix rows.
5. Select the SR-1 SRS for VCCS requirement (for this you might need to expand the 1 System
Requirements package first) and drag it onto the Row Scope box in the Criteria area above the matrix
contents. The SR-1 SRS for VCCS requirement becomes the scope of the matrix rows (see the following
figure).
6. Select column element types:
a. In the Model Browser, select any part property, proxy port, and value property.
To select the set of non-adjacent items in the tree, click the first one, press Ctrl, and while
holding it down, select other items one by one.
b. Drag the selection onto the Column Type box in the Criteria area above the matrix contents. The
columns of the matrix are set to display all the part properties, proxy ports, and value
properties (see the following figure) within the scope you select in the next step.
a. In the Model Browser, select the VCCS block (you might need to expand the 1 System
Structure package beforehand).
b. Drag the selection onto the Column Scope box in the Criteria area above the matrix contents. The
selected block becomes the scope of the matrix rows (see the following figure).
To specify a satisfy relationship from the p1 : UserDataInput proxy port to the SR-1.1 Setting Desired
Temperature requirement
• Double-click the cell at the intersection of the column that displays the proxy port and the row that
displays the requirement. The satisfy relationship is created between the appropriate items and
displayed in the cell.
Having this information, you are ready to specify the solution architecture of each logical subsystem.
As noted previously, an LSSA of each logical subsystem should be stored in a separate model, apart from
the problem domain definition and LSA model. The highlighted area in the following figure shows the part
of the solution domain we are talking about. As you can see, these models can be developed in parallel.
A complete LSSA model consists of the specification of subsystem requirements, structure, behavior, and
parameters. Additionally, every SysML element you create in this model must satisfy at least one
subsystem requirement; otherwise, there is no motivation for having it in the LSSA model. Therefore, you
have to start and end the LSSA model with subsystem requirements: first specify them and, when your
model is complete, establish traceability relationships between them and SysML elements.
Note that the following material mainly focuses on building the logical architecture of a single subsystem
of interest. This is the Cooling System of the VCCS. You should keep in mind that while you build the
logical architecture for the Cooling System, other engineers / engineering teams will work in parallel to
build the logical architectures of the CP System, Heating System, and HMI System.
Subsystem Requirements
What is it?
To provide the solution architecture of the logical subsystem, the responsible engineering team needs to
analyze the relevant subsystem requirements specification, which is produced when having the complete
LSA model. Each subsystem requirement from the leaf level of the specification, should point either to a
particular system requirement or an element from the LSA model (e.g., value property or proxy port of the
block which represents the relevant logical subsystem). This proves the necessity of the subsystem
requirement (just like system requirements point to stakeholder needs or problem domain model
elements).
After you are done with the LSSA, you should establish satisfy relationships from the LSSA elements to
subsystem requirements in order to assert which LSSA elements fulfill which subsystem
requirements. This is described in Chapter Traceability to Subsystem Requirements.
Who is responsible?
The subsystem requirements specification can be produced by the Systems Architect or Systems Engineer,
who has built the LSA model.
In the modeling tool, a single subsystem requirement can be captured as the SysML requirement. Just like
a system requirement, the requirement for a subsystem must have a unique identification, name, and
textual specification, which must be formal and written by following certain guidelines (examples of such
guidelines are provided in Chapter System Requirements).
As with system requirements, subsystem requirements can be categorized and organized into hierarchies.
A SysML requirement diagram or table can be used to capture and display them.
Matrices and maps can be used to establish and review the cross-cutting relationships between the
subsystem requirements and system requirements or LSA model elements.
Therefore, before organizing packages for building the LSSA of the Cooling System, you need to create a
new model and then, in terms of the modeling tool, use the LSA model in it. It should be noted here, that
an LSSA model should be created for each logical subsystem identified in the LSA.
To create a new model for the LSSA of the Cooling System and organize it to capture the subsystem
requirements specification
1. Start sharing the LSA model. Once you share it, the problem domain analysis model used in the LSA
model becomes shared, too.
For more information on this topic and the topics mentioned in steps 2 and 3, refer to
the latest documentation of your modeling tool.
2. Create a new model. This is the solution architecture model of the Cooling System, so it can be
named Cooling System Solution.mdzip.
3. Use the LSA model as read-only in the LSSA model of the Cooling System. The problem domain
analysis model is automatically used as well.
Names in grey indicate elements that cannot be modified, as the problem domain model is
used in the solution domain model as read-only.
4. Right-click the Model package (this is the default name of the root package) and select Create
Element.
5. In the search box, type pa, the first two letters of the element type Package, and press Enter.
6. Type 2.1 Cooling System Solution Domain to specify the name of the new package and press Enter.
Let's agree that packages for storing the solution architectures of other logical subsystems
(such as the CP System and Heating System, among others) should include 2.2, 2.3, and so on
in their names.
7. Right-click the 2.1 Cooling System Solution Domain package and select Create Element.
8. In the search box, type pa, the first two letters of the element type Package, and press Enter.
Note that the diagram is named after the package where it is stored. This name also works for
the diagram. You may only remove the sequence number from its name.
# Name Text
1 Air for Cooling The Cooling System shall be able to draw the air out of the cabin and blow back the
cooled air.
8 Operating While working the Cooling System shall cool down the cabin air until the CP System
requires to stop.
As you already know how to capture requirements in the diagram, we assume that you can do this on your
own. If you need to refresh your knowledge, refer to the procedure in step 3 of the System
Requirements tutorial. When you are done, the Subsystem Requirements diagram in your model should look
very similar to the one below.
You also need to group, number, and categorize the subsystem requirements. These topics are described
in step 4, step 5, and step 6 of the Stakeholder Needs tutorial, so we assume that you can do this on your
own, too. As you can see in the following figure, subsystem requirements should be:
• Grouped under the SRS for Cooling System grouping requirement (if you need a reminder on how to
display relationships on the diagram, refer to the procedure in step 3 of the System
Requirements tutorial)
• Numbered using the SSR- prefix
• Categorized into interface, functional, non-functional, and physical requirements
In this case, we recommend utilizing the infrastructure of one of the predefined matrices in the modeling
tool: either the Derive Requirement Matrix or the Refine Requirement Matrix. Whatever matrix you choose,
unlike in other cases, you need to update the dependency criteria to set up the matrix criteria. Hence, if it
is the Derive Requirement Matrix, you need to set the refine relationship as dependency criteria in addition
to the deriveReqt relationship, and if it is the Refine Requirement Matrix, you need to set the deriveReqt
relationship as dependency criteria in addition to the refine relationship. The following figure displays how
the dependency criteria in your matrix should look like.
The following procedure shows how to create only one of the matrices, the Derive Requirement Matrix,
but you can create the alternative one on your own and see which one suits better for you.
As in other models, traceability views and relationships should be stored in a separate package. Because
you already know how to create packages, we assume that you can do this on your own. For keeping your
model well-organized according to the MagicGrid framework, that package should always be the last sub-
package of the 2.1 Cooling System Solution Domain package. Therefore, its name must begin with number
5 (for example, 5 Traceability).
1. In the Model Browser, right-click the 5 Traceability package and select Create Diagram.
2. In the search box, type drm, the acronym for the predefined Derive Requirement Matrix, and press
Enter.
If you don’t see any result, click the Expert button below the search results list. The list of
available diagrams expands in the Expert mode.
3. Type Subsystem Requirements to System Requirements and LSA to specify the name of the new matrix
and press Enter again.
4. In the Model Browser, select the SSR-1 SRS for Cooling System requirement and drag it onto the Row
Scope box in the Criteria area above the matrix contents. The SSR-1 SRS for Cooling
System requirement becomes the scope of the matrix rows.
5. Select the column element types:
a. Holding down the Ctrl key, in the Model Browser, select any part property, proxy port, and value
property.
b. Drag the selection onto the Column Type box in the Criteria area above the matrix contents. The
columns of the matrix are set to display all the part properties, proxy ports, and value properties
in addition to requirements, which is set by default, within the scope you select in the next step.
a. In the Model Browser, select the SR-1 SRS for VCCS requirement (for this you might need to
expand the following packages beforehand: 2 Solution Domain and 1 System Requirements).
It is also worth to change the style of the Refine relationship so it differs from the
DeriveReqt relationship in the matrix (see the following figure). For more information, refer
to the documentation of the modeling tool.
e. Click OK to close the dialog. Together with the deriveReqt relationship, the refine relationship is
set as dependency criteria for the matrix.
8. Click the Direction box and select Row to Column to enable the creation of relationships pointing from
subsystem requirements, which are row elements, to system requirements of LSA elements, which
are column elements.
9. Click the Refresh hyperlink in the notification box below the Criteria area. The contents of the matrix
are updated. All the cells are empty at the moment.
The following figure displays the Criteria area of the matrix, with highlights on step 4, 5, 6, 7, and 8
related criteria.
Now you’re ready to establish both derivation and refine relationships. Let’s create the derivation between
SSR-1.1.1 Air for Cooling and SR-1.4 Cabin Air. This will convey that the SSR-1.1.1 Air for Cooling subsystem
requirement is created because of the SR-1.4 Cabin Air system requirement.
1. Double-click the cell at the intersection of the row that displays SSR-1.1.1 Air for Cooling and the
column that displays SR-1.4 Cabin Air.
If you want to read the requirement text before setting the relationship, just hover the mouse
over that requirement name. The text will appear in the tool tip.
2. Select DeriveReqt to create a derivation relationship. The derivation relationship is created between
the appropriate items and displayed in the cell.
After all derivation relationships are established, the Subsystem Requirements to System Requirements and
LSA matrix in your model should resemble the one in the following figure.
As you can see, the SSR-1.2.1 Internal Communication subsystem requirement has no derivation to any
system requirement. This is because the SSR-1.2.1 Internal Communication subsystem requirement was
• Double-click the cell at the intersection of the column that displays the p3 or p4 proxy port and the
row that displays the SSR-1.2.1 Internal Communication subsystem requirement. The refine
relationship is created between the appropriate items and displayed in the cell.
Although derived from the system requirement, the SSR-1.1.1 Air for Cooling subsystem requirement also
refines the p1 and p2 proxy ports of the Cooling System block from the LSA model. We assume, you create
appropriate relationships on your own.
You can begin building the solution architecture of a subsystem by defining the internal structure of that
subsystem and specifying how its components operate together, and how they interact with other
subsystems of the same SoI.
As you may recall, the interfaces for interacting with other subsystems are defined in the LSA model by
the system architect. These are the constraints the engineering team appointed to build the solution
architecture of a single subsystem have to deal with. This ensures the model integrity of the whole SoI.
If changes are required (for example, an additional interface is necessary, or an existing interface is
acknowledged as not needed) the engineering team applies to the systems architect, who considers the
request. If the request is accepted, other engineering teams must be informed about the change to ensure
integrity at the system level.
Who is responsible?
The structure of the appointed logical subsystem can be captured by the Systems Architect, or the
Systems Engineer who belongs to the engineering team responsible for building the solution architecture
of that logical subsystem.
How to model?
In the modeling tool, the components of the subsystem can be defined by using the infrastructure of the
SysML block definition diagram (bdd). Components themselves can be captured as blocks, and interfaces
as proxy ports typed by appropriate interface blocks.
Tutorial
• Step 1. Organizing the model for subsystem structure
• Step 2. Getting ready to capture the subsystem structure
• Step 3. Capturing components of the Cooling System
• Step 4. Creating an ibd for specifying interactions
• Step 5. Specifying interactions with the outside
• Step 6. Specifying interactions within the Cooling System
1. Open the solution domain model of the Cooling System (the Cooling System Solution.mdzip file) you
created in step 1 of the Chapter Subsystem Requirements tutorial, if it is not opened yet.
2. Right-click the 2.1 Cooling System Solution Domain package and select Create Element.
3. In the search box, type pa, the first two letters of the element type Package, and press Enter.
4. Type 2 Subsystem Structure to specify the name of the new package and press Enter.
To keep the inner structure of the 3 System Structure package well organized, you need to create a few
more packages. These are:
• 1 Logical Interfaces
• 2 Exchange Items
• 3 Logical Components
When you create them on your own (by following the previous procedure), the Model Browser of your
solution domain model of the Cooling System should look the same as the following figure.
Although the engineering team of the subsystem can read the LSA model, they cannot make any changes
there. The first thing they should do to get ready to model the subsystem structure is create a block that
captures the particular subsystem of interest (in this case, the Cooling System) and enable it to inherit all
the relevant interfaces from the LSA model.
The inheritance can be achieved by establishing a generalization relationship between two blocks
representing the Cooling System: the one in the LSA model (as the super-type) and the other in the LSSA
model of the Cooling System (as the sub-type). As a result, the sub-type block inherits all the
specifications (including proxy ports typed by appropriate interfaces) from the super-type block. It's
important to note here that inherited proxy ports should be redefined; otherwise, certain tasks of building
the LSSA cannot be accomplished; for example, specification of satisfy relationships from proxy ports to
relevant subsystem requirements.
The generalization relationship can be created by utilizing the infrastructure of a bdd, which can be created
under the 2 Subsystem Structure package within the solution domain model of the Cooling System (created
in step 1 of this cell tutorial).
a. Click the Block button on the diagram palette and then click on the diagram pane.
b. Type Cooling System Architecture to name the block and press Enter.
3. Display the Cooling System block from the LSA model on the diagram:
a. Select the Cooling Systemblock in the Model Browser (you may need to subsequently expand the2
Solution Domain, 2 System Structure, and the 3 Logical Subsystemspackagesfirst).
b. Drag the selection to the diagram pane. The shape of the Cooling System block is displayed on the
diagram.
4. Draw a generalization between the Cooling System block (super-type) and the Cooling System
Architecture block (sub-type):
a. Double-click the shape of the Cooling System Architecture block on the diagram.
b. On the left of the open dialog, click Ports/Interfaces.
c. Select the proxy port in the first row and click the Redefine button below.
As a result, the selected proxy port is redefined and since that moment no longer decorated with
the caret symbol (“^”), which indicates the inheritance. Don't change anything.
e. Click Close.
6. Display the proxy ports and interfaces of the Cooling System Architecture block on its shape:
a. Select the shape of the Cooling System Architecture block on the diagram pane.
b. Click the Display All Ports button on its smart manipulator toolbar.
Based on their experience, the appointed engineering team identifies a few more components:
• Receiver Dryer
• Metering Device
All these items can be captured using either bdd or ibd, although we use the Cooling System Structure bdd
(created in step 2 of this cell tutorial). The ibd is useful later, when you need to represent interactions
between the specified components.
1. Open the Cooling System Structure bdd, created in step 2 of this cell tutorial, if not opened yet.
2. Select the Cooling System Architecture block, click the Directed Composition button on its smart
manipulator toolbar (see the following figure), and then click a free space on the diagram pane.
Another block is created in the Model Browser and its shape is selected on the diagram pane.
4. Repeat steps 2 and 3 as many times as you need to create the Condenser, Evaporator, Receiver Dryer,
and Metering Device blocks.
1. In the bdd Cooling System Structure, select the Cooling System Architecture block and click the SysML
Internal Block Diagram button on its smart manipulator toolbar (see the following figure). The ibd
is created and the Display Parts/Ports dialog opens on top of it.
It is not necessary to capture all communications in the same diagram. Therefore, we will skip
showing a couple of proxy ports, as they are not relevant to the aspect we are going to model
in the newly created diagram.
3. In the Model Browser, where the newly created diagram is automatically selected in the edit mode,
type Cooling System Logical Components to specify its name and press Enter again.
We can start from specifying the interactions via the inherited interfaces (the ones identified in the LSA).
There are two of them in this diagram: one for letting the air into the Cooling System, and the other is for
To specify that the Compressor consumes the air from the cabin
1. Select the p1 proxy port (typed by the insideAirInlet interface block) on the diagram frame and click
the Connector button on its smart manipulator toolbar.
2. Click the shape of the cmp part property (typed by the Compressor block).
3. Select New Proxy Port. A compatible proxy port is created for the Compressor block and the connector
is established between the diagram frame and the selected part property.
4. In the Model Browser, expand the contents of the following read-only packages: 2 Solution Domain > 2
System Structure > 2 Exchange Items.
It is important that exchange items for communication with the outside are only taken from
the LSA model. Otherwise, the consistency and integrity of different logical subsystem models
is broken.
5. Select the Cabin Air block and drag it to the newly created connector on the open diagram pane.
According to SysML, the element you want to specify as the item flowing over the connector
must be the type of at least one of the flow properties owned by the interface block that types
the connected proxy ports.
6. Don’t make any changes in the open dialog; click OK. The Cabin Air block is specified as the item
flowing over the newly created connector.
However, we are not finished yet. Let's say that the engineering team has identified two more interfaces
that are mentioned neither in the system requirements nor in the subsystem requirements specification:
one for letting the hot air out the vehicle, and the other for removing the moisture separated from the
refrigerant out of the VCCS. To capture this information in the model, you need to create two new interface
blocks and assign them to the VCCS block as proxy ports. Since it is system level information, this can only
be done in the LSA model. Therefore, the engineering team of the Cooling System must inform the
systems architect about two new interfaces and request for relevant changes the LSA model. When this is
done, the engineering team of the Cooling System can update their model to let the Cooling System
Architecture block inherit two new proxy ports from the LSA model. These changes may also impact the
work of other engineering teams; in that case, the systems architect must take the responsibility to inform
them.
We assume that you temporarily get back to the LSA model and capture the mentioned interfaces on your
own (this procedure is explained in Chapter System Structure). Once you're done, the Logical Architecture of
VCCS bdd in your model should look like the diagram in the following figure (the updates are highlighted).
It is also important to note that the subsystem and even system requirements must be reviewed and
updated accordingly. We will get back to this in Chapter Traceability to Subsystem Requirements.
To display the newly created proxy ports on the Cooling System Logical Components ibd frame
1. Make sure the solution domain model (file) is updated in the solution domain model of the Cooling
System.
For more information on this topic, refer to the latest documentation of your modeling tool.
2. Open the Cooling System Logical Components diagram, if not opened yet.
3. Select the diagram frame and click the Display All Ports button on its smart manipulator (see the
following figure). All the proxy ports of the Cooling System block are displayed on the diagram frame.
After you capture that the Condenser releases the unneeded hot air out of the Cooling System, and the
Receiver Dryer lets out the moisture, your ibd should look the same as the diagram below.
Now if you open the Cooling System Structure bdd created in step 3 of this cell tutorial, you can update it
to display new proxy ports on the blocks that capture the Cooling System and some of its components.
1. The Compressor consumes the refrigerant in the form of low pressure and low temperature gas and
transforms it into high pressure and high temperature gas (almost liquid).
2. Inside the Condenser, the refrigerant turns into liquid.
3. The Receiver Dryer separates the moisture from the refrigerant, but doesn't change its physical
characteristics.
4. The Metering Device makes the refrigerant turn into low pressure and low temperature liquid.
5. The Evaporator turns the refrigerant into gas and provides it to the Compressor to close the loop.
The list above determines one more interface of the Cooling System. It is for exchanging the refrigerant
and can be captured in the model as a new interface block. The engineering team doesn't need to inform
anybody about the newly identified interface; it is used for internal communication only and can be
captured in the solution domain model of the Cooling System.
1. Create a bdd:
a. Right-click the 2 Exchange Items package and select Create Diagram.
b. In the search box, type bdd, the acronym for SysML block definition diagram, and then press
Enter. The diagram is created.
c. Type Refrigerant Conditions to specify the diagram name and press Enter again.
2. Drag the Refrigerant signal to the diagram pane. The shape of it is created on the diagram.
3. To refactor the Refrigerant signal to a block:
a. Right-click it and select Refactor > Convert To > Block.
b. Click OK to remove all properties that are incompatible between these two types.
4. Select the Refrigerant block and click the Generalization button on its smart manipulator toolbar.
5. Click an empty place on the diagram pane.
6. Type LPLTG directly on the new shape to name the block and press Enter.
When you're done, you can specify the interactions between the components of the Cooling System
(listed at the beginning of this step).
To specify that the Compressor provides the Refrigerant to the Condenser, in the form of high pressure and
high temperature gas
1. Make sure the Type Selection Mode is enabled in the Cooling System Logical Components diagram.
Otherwise, creation of a proxy port doesn't trigger selection of the interface block to type that proxy
port.
2. Select the shape of the part property typed by the Compressor block and click the Proxy Port button
on its smart manipulator toolbar. A new proxy port appears on the border of the part property
shape.
3. Type ref to find the RefrigerantExchange interface block in the Select Type list, press the Down Arrow
key to select it, and then press Enter.
4. Click the Connector button on the smart manipulator toolbar of the newly created proxy port.
5. Click the shape of the part property typed by the Condenser block.
6. Select New Proxy Port. A compatible proxy port is created for that part property, and the connector
between the couple of part properties is established.
According to SysML, the element you want to specify as the item flowing via the connector
must be the type of at least one of the flow properties owned by the interface block that types
the connected proxy ports. This also works with sub-types. That’s why the Refrigerant block as
well as any of its types (in this case, the HPHTG block), can be assigned to the connector.
8. Don’t make any changes in the open dialog; click OK. The HPHTG block is specified as the item
flowing via the newly created connector.
In the same way, specify the rest of the previously described interactions. Once you’re done, your ibd
should be similar to the one in the following figure.
The connector colors can be changed by modifying their symbol properties. For this, right-click the
connector and select Symbol Properties. In the open dialog, select the value cell of the Pen
Color property and click the ... button to open the Color dialog. Then select blue, or any other color
you want, and close both dialogs.
• Having logical components and knowing how they communicate, you can proceed with structure
modeling and go inside each logical component.
• However, there are still two unvisited cells of the solution architecture for the subsystem. That's
why you should proceed to Chapters Subsystem Behavior and Subsystem Parameters.
Once finished with the subsystem structure, the appointed engineering team can switch to modeling the
behavior of that subsystem. Behavior models can be relatively abstract and must satisfy functional
requirements of that subsystem (see Chapter Subsystem Requirements). Using the capabilities of
the modeling tool, these models can be executed against test cases to show whether or not these
functional requirements are satisfied.
When finished, the subsystem behavior should be integrated with other subsystem behaviors, into a single
model that represents the comprehensive behavior of the whole SoI. This can be achieved only if the
integrated models are compatible; that is, if they can communicate over interfaces and exchange items.
Remember that interfaces and exchange items are determined by the systems architect in the LSA model.
This cell can be skipped if the engineering team makes the decision to model the behavior of each logical
component captured in the structure model of that logical subsystem (see Chapter Subsystem Structure).
Note that the following material mainly focuses on building the behavioral model of the Cooling System of
the VCCS. In the final steps of this cell tutorial, the scope extends to include the behavioral model of the
CP System. This is necessary for learning how to model the communication between the two subsystems.
Behavioral models of other subsystems, like Heating System and HMI System, are not included;
however, you should imagine that appointed engineers / engineering teams work on them in parallel.
Who is responsible?
The behavior of the appointed logical subsystem can be captured by the Systems Architect, or the
Systems Engineer who belongs to the engineering team responsible for building the solution
architecture of that logical subsystem.
How to model?
The behavior model of the subsystem can be captured by utilizing the infrastructure of the SysML state
machine and activity or sequence diagrams in combination. The state machine allows for capturing states
of the subsystem and transitions between them in response to event occurrences over time. The activity or
sequence diagrams should be used to specify the entry, do, and exit behaviors of these states or transition
effects.
The following figure displays the SysML state machine diagram, identifying the main states of the Cooling
System. Transitions between states can be triggered by various types of events (i.e., a signal event such
as Start between the Off and On states). These signals are taken from the LSA model. This ensures the
integrity of behaviors models of diverse logical subsystems.
Tutorial
• Step 1. Organizing the model for subsystem behavior
• Step 2. Creating a diagram for capturing Cooling System states
• Step 3. Capturing states of the Cooling System
• Step 4. Specifying event occurrences on transitions
• Step 5. Specifying internal behaviors of the state
• Step 6. Synchronizing item flows from the structure model
However, if you need to specify some behavior that the Cooling System performs while being in one or
another state or in transition from one state to another, you should specify that behavior in a separate
package. Following the design of the MagicGrid framework, this package should be stored under the
structure of packages displayed in the following figure.
1. Open the solution domain model of the Cooling System (the Cooling System Solution.mdzip file) you
created in step 1 of the Chapter Subsystem Requirements tutorial, if not opened yet.
2. Right-click the 2.1 Cooling System Solution Domain package and select Create Element.
3. In the search box, type pa, the first two letters of the element type Package, and press Enter.
4. Type 3 Subsystem Behavior to specify the name of the new package and press Enter.
To create a SysML state machine diagram for capturing the Cooling System states
1. Open the solution domain model of the Cooling System you created in step 1 of the
Chapter Subsystem Requirements tutorial, if not opened yet.
3. Create the SysML state machine for the Cooling System Architecture block:
a. Right-click the Cooling System Architecture block and select Create Diagram.
b. In the search box, type smd (the acronym for the SysML state machine diagram) and then press
Enter. The diagram is created with the initial state and an unnamed one to jump-start the states
definition.
c. Type Cooling System States to specify the name of the new diagram and press Enter again.
1. Off
2. On:
a. Initializing
b. Idling
c. Operating
Event occurrences that trigger transitions between states are discussed later in this tutorial. This step
mainly focuses on creating states and transitions between them.
1. Open the Cooling System States diagram, if not opened yet. The diagram already contains the initial
state and an unnamed state.
2. Select the shape of the unnamed state and then click somewhere in the middle of that shape. The
shape switches to the name edit mode.
3. Type Off to specify the name and press Enter.
4. Select the shape of the Off state and click the Transition button on its smart manipulator toolbar.
5. Click an empty place on the diagram pane. Another state is created.
6. Type On directly on the shape of that state and press Enter.
7. Drag the corner of the newly created shape to enlarge it. This is necessary for creating internal states
within it.
8. Click the Initial button on the diagram palette and move the mouse over the shape of the On state.
9. When you see the blue border around the shape of the On state, click it. The initial state is created
within the shape of the On state, and the On state automatically becomes composite.
10. Select the shape of the initial state and click the Transition button on its smart manipulator
toolbar.
11. Right-click an empty place on the shape of the composite state and select State. Another internal
state of that composite state is created.
12. Type Initializing directly on the shape of that state and press Enter.
It's important to note that these signals come from outside the Cooling System. They actually come from
the CP System, to be more precise. Therefore, the engineering team doesn't need to capture them in the
LSSA model of the Cooling System. These signals have already been captured in the LSA model and
therefore must be taken from there. The engineering team that works on the LSSA of the CP System uses
these signals in their model, too. The only difference is that the CP System sends them to the outside.
Let's start from specifying the trigger on the transition between the Off and On states.
To make the Start signal a trigger of the transition between the Off and On states of the Cooling System
4. When you release the mouse, the Start signal becomes the signal event that triggers the transition
between the Off and On states of the Cooling System.
When you're done, you can run the simulation to validate the specified behavior and see if your model is
correct. To start the simulation session, click the Run button on the Cooling System States diagram
toolbar. In the Simulation panel, click the Start button to start the machine execution. Note that the
state machine enters the Off state and rests there waiting for the Start signal to trigger it.
There are two places from where you can fire the transition:
• On the diagram
Try to fire all the transitions and see if all states can be visited. As you may see, a couple of transitions still
have no triggers. These will be specified later, following a certain logic of subsystems communication.
Now it's time to imagine yourself being the engineering team who is responsible for the LSSA of the CP
System, and create the state machine capturing the behavior of that logical subsystem. This is necessary
When you have the model you see in the preceding figure, you can specify the behavior of the CP System.
Note that the Ignition On and Ignition Off signals are captured in the LSSA model of the CP System, while
the DesiredTmpSet and Idle signals are taken from the LSA model.
To make the Ignition On signal a trigger of the transition between the Off and On states of the CP System
As you can see, the Operating state transition to self is triggered by another type of event: a relative time
event. It allows the modeler to specify that every 3 seconds the CP System moves back to the Operating
state. There will be an internal behavior assigned to this state, performed every time it enters the Operating
state.
To make the time event a trigger of the transition from the Operating state to itself
After you're done with states of the CP System, run the simulation and see if the behavior model is
correct.
You have now created two state machines: one for the Cooling System and the other for the CP System.
Moreover, you have specified that the Cooling System is waiting for signals from the CP System. Now it's
time to capture when and how the CP System sends them.
Let's say the appointed engineering team has to specify that when the CP System enters
the Initializing state, it invokes other logical subsystems of the VCCS. Therefore, it should send the Start
signal to all of them. Since the signal should be sent to outside the CP System, it is important to capture
that it is passed via the p2 proxy port, as shown in the following figure.
1. Open the LSSA model of the CP System (the one you created in the previous step), if not opened yet.
2. Create a new SysML activity diagram:
3. Click the Initial Node button on the diagram palette and then an empty place on the diagram pane.
The initial node is created and displayed on the diagram.
4. In the Model Browser, select the Start signal:
5. Drag the selected signal to the newly created diagram pane. The Start send signal action is created and
displayed in the diagram pane.
6. Establish a control flow between the two nodes:
a. Select the initial node and click the Control Flow button on its smart manipulator toolbar.
b. Click the Start send signal action. The control flow is created.
As a result, the selected proxy port name displays on the shape of the Start send signal action.
As a result, the Initialize Other Subsystems activity is set as the entry behavior of the Initializing state.
The engineering team appointed to build the LSSA of the Cooling System has to specify the reaction of
that subsystem to the Start signal. Let's say the Cooling System in response sends the coolStatus signal
with the coolOK attribute value true, if it is ready to start, and false, if it is not. As you can see in the
following figure, the response signal is sent over the p4 proxy port. Reactions of other logical subsystems
To specify that the Cooling System, when in the Initializing state, performs a self-check and sends out
the coolStatus signal with appropriate attribute value
1. Open the LSSA model of the Cooling System (the one you created in step 1 of the Subsystem
Requirements tutorial), if not opened yet.
2. Create a new SysML activity diagram:
3. Click the Initial Node button on the diagram palette and then an empty place on the diagram pane.
The initial node is created and displayed on the diagram.
a. Click the Control Flow button on the smart manipulator toolbar of the newly created initial
node.
b. Right-click a free space below and select Decision.
a. Click the small black triangle next to the Action button on the diagram palette and then select
Opaque Action.
b. Click an empty place on the diagram pane. A new opaque action is created and displayed on the
diagram.
c. Type coolOK=true; directly on the shape.
d. Click somewhere on the diagram pane when you're done.
6. Establish a control flow between the decision node and the newly created opaque action, with 80
percent probability:
a. Select the decision node and click the Control Flow button on its smart manipulator toolbar.
b. Click the opaque action. The control flow between actions is created.
c. Make sure the control flow is still selected and press Enter.
d. In the Specification of the control flow, find the Probability property and type 0.8 in its value cell.
7. Follow step 5 to create another opaque action. This time set the coolOK attribute value to false (see the
following figure).
b. Drag the selected signal to the open diagram pane. The send signal action with the same name is
created and displayed on the diagram pane.
10. Establish object flows from each opaque action to the send signal action:
a. Select one of the opaque actions on the diagram pane and then click the Object Flow button
on its smart manipulator toolbar.
b. Click the input pin of the send signal action. The object flow is created, and a new output pin is
attached to the opaque action.
c. Click the pin label on the diagram pane. Then click it again to enter the name edit mode.
d. Type coolOK to change the pin name.
Note that pins do not display their types, only their names, in the following figure. For
this, do the following:
i. Press down the Shift key and select both pins.
ii. Right-click the selection and click to select the Show Name check box.
iii. Then click Show Type to clear the selection.
When you're done with this state machine diagram, try to run the simulation again. Before starting the
model execution, be sure the Auto Open Diagrams mode is enabled (see the following figure). In this
mode, the tool automatically opens the diagram that is currently executed. Hence, when the model
execution switches from the Cooling System States diagram to the Perform System Check diagram (the one
The appointed engineering team also has to specify what the CP System does after it gets the responses
from other subsystems. It should evaluate the status of all subsystems according to this information and
send them signals triggering them to move either to the Idling, or to the Off state. As you can see in the
following figure, the appropriate signals are sent over the p2 proxy port.
Note that the SysOK and SysNotOK signals are not defined in any of your models, although they should
have been identified in the LSA model by the system architect many cells ago (see step 5 of the System
Structure tutorial). This means that the system architect must be informed about two new identified
signals. As soon as he/she updates the LSA model, the signals can be used in the LSSA models of all
logical subsystems. Here we expect you to update the LSA model appropriately on your own.
To specify that the CP System evaluates the status of all subsystems and sends them appropriate signals
1. Open the LSSA model of the CP System (the one you created in the previous step), if not opened yet.
2. Create a new SysML activity diagram:
3. Click the Initial Node button on the diagram palette and then an empty place on the diagram pane.
The initial node is created and displayed on the diagram.
4. Create an accept event action waiting for the coolStatus signal:
a. Click the Accept Event Action button on the diagram palette and then an empty place on the
diagram pane. The accept event action is created and displayed on the diagram.
b. In the Model Browser, select the coolStatus signal:
c. Drag the selected signal onto the shape of the accept event action. It becomes the coolStatus
accept event action.
d. Double-click the accept event action.
e. In its Specification, find the Is Unmarshall property and set its value to true.
f. Close the dialog.
g. When the shape of the coolStatus accept event action is surrounded by the yellow border, select
the shape and click the button with the yellow triangle (see the following figure).
h. Select Synchronize Accept Event Action Output Pins by Signal Properties.
The output pin named and typed after the attribute of the coolStatus signal is attached to the
shape of the accept event action.
a. Click the small black triangle next to the Action button on the diagram palette and then select
Opaque Action.
6. Establish a control flow between the initial node and the opaque action:
a. Select the initial node and click the Control Flow button on its smart manipulator toolbar.
b. Click the opaque action. The control flow is created.
7. Establish an object flow between the coolStatus accept event action and the opaque action:
a. Select the output pin of the coolStatus accept event action and click the Object Flow button
on its smart manipulator toolbar.
b. Click the opaque action. The object flow is created along with the input pin attached to the
opaque action.
c. Click the label of the input pin on the diagram pane. Then click it again to enter the name edit
mode.
d. Type coolOK to rename the pin and press Enter.
9. Create the coolingReady value property for the CP System Architecture block:
a. In the Model Browser, right-click the block and then select Create Element.
b. In the search box, type vp, the acronym of the value property, and press Enter. The new value
property is created and appears in the name edit mode.
a. Click the Control Flow button on the the smart manipulator toolbar of the opaque action.
b. Right-click a free space below and select Decision.
b. Drag the selected signal to the diagram pane twice. Two of the SysOK send signal actions are
created and displayed in the diagram pane.
12. Repeat previous step to create two more of the SysNotOK send signal actions.
13. Create control flows you see in the following figure on your own.
14. Specify the condition when all the subsystems transit to the Idling state:
Note that the closing bracket is added automatically. You don't need to do this.
15. Specify the condition when all the subsystems transit to the Off state:
The following diagram shows how the Evaluate Status diagram would look, if you specified that
the CP System takes into consideration the status of all logical subsystems.
Afterwards, state machine diagrams of both logical subsystems must be updated, by specifying the
signals which trigger the transitions to the Idling and Off states. You can do this on your own (see step 4 of
this cell tutorial, if you need to refresh your knowledge).
1. Select the object flow between the Compress Refrigerant and Turn Gas Into Liquid actions.
2. Click the Realize All Item Flows button on the smart manipulator toolbar of the object flow.
• Once you define the supposed behaviors of all the logical subsystems, you can start integrating
their LSSA models into the whole and create diverse configurations of the SoI model (see Chapter
Building system configuration model).
• You can also go to the Subsystem Parameters cell and determine the method for calculating one or
more subsystem parameters.
You can go to this cell as soon as the subsystem structure is captured in the model.
Subsystem parameters capture quantitative characteristics of the relevant logical subsystem, that you can
measure. They are used to calculate MoEs for that logical subsystem, identified during the problem
domain analysis (see Chapter MoEs for Subsystems). MoEs for subsystems captured in the solution
domain model satisfy non-functional quantitative subsystem requirements.
Mathematical expressions for MoEs derivation from subsystem parameters should also be specified in this
cell. Knowing how to calculate MoEs enables early subsystem requirements verification. Using the
capabilities of the modeling tool, the model can be executed to calculate these values and give the verdict
on whether quantitative requirements are satisfied or not.
It's important to note here that not all MoEs in the solution domain must be based on the MoEs in the
problem domain model. Some of them can be identified only when building the logical architecture of the
logical subsystem.
Who is responsible?
Parameters of the appointed logical subsystem can be captured by the Systems Architect or Systems
Engineer, who belongs to the engineering team responsible for building the LSSA of that logical
subsystem.
How to model?
Just like MoEs for the whole system of interest, the MoEs for logical subsystems can be captured in the
model as value properties with the «moe» stereotype applied. These value properties must belong to the
block, which represents the relevant logical subsystem. You must also know that measures of
effectiveness can be inherited from the reusable sets of MoEs, so called MoEs holders, instead of
specifying them from scratch.
The formula for calculating the MoE can be captured as a constraint expression of some constraint block.
The infrastructure of the SysML block definition diagram can be utilized for capturing MoEs, constraint
expressions, and even required subsystem parameters. The following figure displays the bdd that captures
the totalEnergyConsCool measure of effectiveness and the formula for calculating this MoE as the
constraint expression of the Total Energy Consumption for Cooling constraint block.
The simulation capabilities of the modeling tool allow you to calculate MoEs with given inputs. Having the
MoE calculated, you can verify the appropriate non-functional subsystem requirement and show whether
it is satisfied or not. The modeling tool enables you to perform this verification automatically. To get ready
for the automated requirements verification, you need to create a satisfy relationship from the value
property, which captures the MoE, to the appropriate subsystem requirement. The following figure
displays an example of the satisfy relationship between the totalEnergyConsCool value property and
the Max Energy Consumption for Cooling non-functional requirement, which means that the requirement is
satisfied when the value of the totalEnergyConsCool value property is not greater than 1.2 kWh. As you can
see, the natural language expression in the requirement text is refined by another constraint expression of
the Max Energy Consumption for Cooling constraint block with the x <= 1.2 inequality.
Tutorial
• Step 1. Organizing the model for subsystem parameters
• Step 2. Specifying the MoE for capturing the total energy consumption for cooling
• Step 3. Defining a method to calculate the total energy consumption for cooling
• Step 4. Specifying subsystem parameters for calculating the total energy consumption for cooling
• Step 5. Binding constraint parameters to appropriate value properties
• Step 6. Performing early subsystem requirements verification
• Step 7. Recalculating subsystem parameters in different states
1. Open the solution domain model of the Cooling System (the Cooling System Solution.mdzip file) you
created in step 1 of the Subsystem Requirements tutorial, if not opened yet.
2. Right-click the 2.1 Cooling System Solution Domain package and select Create Element.
3. In the search box, type pa (the first two letters of the element type Package) and press Enter.
4. Type 4 Subsystem Parameters to specify the name of the new package and press Enter.
Step 2. Specifying the MoE for capturing the total energy consumption for
cooling
According to the subsystem requirements specification (see Chapter Subsystem Requirements) and the
MoE identified for the Cooling block in the problem domain model (see MoEs for Subsystems), the
appointed engineering team must specify the MoE for capturing the total energy consumed by the Cooling
System.
It was already mentioned that MoEs can be specified from scratch or inherited form the MoEs holder. The
following procedure describes the latter case. The inherited MoE is redefined to change its name and type.
Redefinition is necessary for automated requirements verification, which is performed in one of the
following steps.
To specify the MoE for capturing the total energy consumed by the Cooling System
a. Right-click on the 4 System Parameters package you created in previous step and select Create
Diagram.
b. In the search box, type bdd (the acronym of the SysML block definition diagram), and then
double-press Enter. The diagram is created.
c. Type Subsystem Parameters for Total Energy Consumption for Cooling to specify the name of the
new diagram and press Enter again.
c. When you see the Cooling System Architecture block selected in the search results list, press Enter.
The block is selected in the Model Browser.
d. Drag the Cooling System Architecture block to the diagram pane. The shape of the block is
displayed on the diagram.
4. Establish the generalization between the Cooling System Architecture block and the MoEs Holder block:
a. Select the shape of the Cooling System Architecture block and click the Generalization button
on its smart manipulator toolbar.
b. Select the shape of the MoEs Holder block. The MoEs Holder block becomes the super-type of the
Cooling System Architecture block, which means that the latter inherits all MoEs from the former.
5. Redefine the totalEnergyConsumption value property for the Cooling System Architecture block:
As you can see, the inherited value property it redefines displays in the curly brackets.
Step 3. Defining a method to calculate the total energy consumption for cooling
The next thing you need to do is capture the mathematical expression which specifies how to calculate the
MoE, minutes ago specified for the Cooling System. It can be captured as the constraint expression of
some constraint block stored in your model.
Let’s say the total energy consumption of the Cooling System equals a sum of energies consumed by all
its components. The constraint expression can be defined as follows:
where:
1. totalEnergyCons stands for the total energy consumed by the Cooling System
2. energyCons1 may stand for the energy consumed by the Compressor
3. energyCons2 may stand for the energy consumed by the Condenser
4. energyCons3 may stand for the energy consumed by the Receiver Dryer
5. energyCons4 may stand for the energy consumed by the Metering Device
6. energyCons5 may stand for the energy consumed by the Evaporator
In terms of SysML, totalEnergyCons, energyCons1, ..., and energyCons5 are generally referred to as
constraint parameters and later should be bound to corresponding value properties specified in the model.
A bdd can be utilized for capturing constraint blocks. This constraint block is not an exception; therefore,
you can use the bdd created in step 2 of this cell tutorial. The procedure of capturing the method for
calculating the total energy consumption of the Cooling System is adequate to the one described in step
3 of System Parameters tutorial. Once you capture the method, the Subsystem Parameters for Total Energy
Consumption for Cooling bdd should look like in the following figure.
The Total Energy Consumption for Cooling constraint block has five input parameters, each for the energy
consumption of a single component of the Cooling System, and therefore requires five component
parameters in your model. Appropriate value properties should be specified for each block that captures
one of the components of the Cooling System.
The procedure for capturing the above mentioned component parameters is adequate to the one described
in step 4 of System Parameters tutorial. Once you're done with this, the Subsystem Parameters for Total
Energy Consumption for Cooling bdd should look like the following figure.
If you name the SysML parametrics diagram Total Energy Consumption for Cooling, the procedure of
establishing the bindings is very similar to the one described in step 5 of the System Parameters tutorial.
Once you're finished with this, the Total Energy Consumption for Cooling parameters diagram in your model
should look like the one below.
Now you can execute the model, provide input values, and see the result of the calculation. To start the
execution, click the Run button in the toolbar above the Total Energy Consumption for Cooling diagram.
When in the Variables tab of the Simulation panel (by default, it is on the right side of
the Simulation panel), you can specify the input values and see the output value (result of the calculation).
Now, if you go back to the Total Energy Consumption for Cooling diagram and execute the model again, you
should see that the totalEnergyConsCool value property is highlighted in green, which means that the Max
Energy Consumption system requirement is satisfied. Try to change the input values and see how the
highlight color changes when the requirement is not satisfied. This is how you perform the automated
requirements verification. Moreover, this way you can perform manual or automatic (it requires some
algorithm to be defined) parameters optimization in order to find the optimal system configuration.
These values can be stored in the model as SysML instance specifications and their slot values. If you
cannot remember how to do this, refer to step 7 of the System Parameters tutorial.
To illustrate this, let's assume that the components of the Cooling System consume more energy in the
Initializing and Operating states, and less energy in the Idling state.
Values can be specified using Action Language Helper (ALH) expressions supported by the modeling
tool in:
• The body of the opaque behavior set as the entry or do behavior of the relevant state.
• The body of the opaque action which belongs to the entry or do behavior of the relevant state.
1. The name of the part property (highlighted in the following figure) that is typed by the block whose
value property you want to update. That part property must belong to the block which encloses the
state machine diagram; in this case, it is the Cooling System Architecture block.
2. The name of the value property you want to update (highlighted in the following figure), in quotes.
The value property must belong to the block which types the previously defined part property.
3. Concrete value you want to set for the previously defined value property (for example, 0.5).
To specify values in the body of the opaque behavior set as the entry behavior of the Idling state of the
Cooling System
7. Click Close. The shape of the Idling state displays the ALH expressions.
To specify the values in the body of the opaque action which belongs to the entry behavior of the
Initializing state
5. Pres Enter.
Following the procedure above, you can update the Cool Down Cabin Air diagram. When finished, you can
run the simulation to see how the totalEnergyConsCool value property changes the value over various states
of the Cooling System. Make sure you run the simulation with the context (the Cooling System Design
block) which encloses the state machine diagram; otherwise, the subsystem parameter value is not
calculated. For this, click the small black triangle next to the Run button and select Run with Context.
To have a complete LSSA model of a particular logical subsystem, you need to establish traceability
relationships from the elements that capture the LSSA to the elements that capture the subsystem
requirements. As determined by SysML, these are the satisfy relationships, meaning that one of the latter
fulfills one of the former; for example, a satisfy relationship can be established from the part property
typed by the block that captures some logical component to a certain subsystem requirement. In the
complete LSSA model, all subsystem requirements are satisfied by one or more architecture elements even
though these elements are not yet implemented.
Who is responsible?
Traceability relationships in the LSSA model of the appointed logical subsystem can be captured by the
Systems Architect or Systems Engineer who belongs to the engineering team responsible for building the
LSSA of that logical subsystem.
How to model?
Neither of the SysML diagrams is suitable for creating a mass of cross-cutting relationships, such
as satisfy. For this, a dependency matrix is more suitable. The modeling tool offers a wide variety of
predefined matrices for specifying cross-cutting relationships. To capture satisfy relationships, a Satisfy
Requirement Matrix can be used.
1. In the Model Browser, right-click the 5 Traceability package (you created it in step 4 in the Subsystem
Requirements tutorial) and select Create Diagram.
2. In the search box, type srm (the acronym of the predefined Satisfy Requirement Matrix), and press
Enter.
If you don’t see any result, click the Expert button below the search results list. The list of
available diagrams expands in the Expert mode.
3. Type LSSA to Subsystem Requirements to specify the name of the new matrix and press Enter again.
4. On the matrix toolbar, click the Change Axes button to swap rows of the matrix with columns.
Requirement becomes the type of the matrix rows.
5. In the Model Browser, select the SSR-1 SRS for Cooling System requirement (you might need to expand
the 1 Subsystem Requirements package first) and drag it onto the Row Scope box in the Criteria area
above the matrix contents. The SSR-1 SRS for Cooling System requirement becomes the scope of the
matrix rows (see the following figure).
6. Select column element types:
a. In the Model Browser, select any part property, proxy port, value property, state, and call
behavior action.
To select the set of non-adjacent items in the tree, click the first one, press Ctrl, and while
holding it down, select other items one by one.
b. Drag the selection onto the Column Type box in the Criteria area above the matrix contents. The
columns of the matrix are set to display all the part properties, proxy ports, value properties,
states, and call behavior actions (see the following figure) within the scope you select in the next
step.
a. In the Model Browser, select the Cooling System Architecture block (you might need to expand
the 1 Subsystem Structure package beforehand).
b. Drag the selection onto the Column Scope box in the Criteria area above the matrix contents. The
selected block becomes the scope of the matrix columns (see the following figure).
As you can see, there are a few proxy ports that cannot trace to any subsystem requirement (as you can
remember, they were identified in Chapter Subsystem Structure). This requires the revision and update of
the subsystem requirements specification, and vice versa. This time, only the subsystem requirements
specification needs to be updated. You can see the new requirements highlighted in the following figure.
After you establish a few more refine relationships in this matrix, it should look like in the following figure.
1. As the systems architect, append the system requirements specification in the LSA model, with two
new interface requirements.
3. In the System Requirements to Stakeholder Needs matrix, establish missing derivation relationships from
new system requirements to stakeholder needs.
When you're done, look at the From Stakeholder Needs to Subsystem Requirements map. It should also be
updated.
As mentioned in the Preface, the component-level model of the solution domain can be both MBSE and
MBD, because this is where the logical architecture relates to the logical (high-level) design of the SoI, and
MBD starts. Therefore, besides SysML, other standards can be applied at the component-level. These
When you have the LSSA models of all logical subsystems, including their components and even more
precise units, you can integrate them and have the entire logical architecture of the SoI in a single
model (see Chapter Building system configuration model).
The highlighted area in the following figure show the part of the solution domain we are talking about.
As you may conclude looking at the design layout of the MagicGrid framework (see the highlighted area in
the following figure), the system configuration model captures the overall structure, behavior, and
parameters of the SoI.
Once all engineering teams deliver the LSSA models of each logical subsystem of the SoI (defined in the
LSA model), the systems architect/integrator is able to finish his/her job. That is, he/she can integrate all
the models into the whole and build the system configuration model.
The main purpose of building the system configuration model is to verify whether logical subsystems of
the system of interest can successfully communicate. The systems architect/integrator must check
whether interfaces of separate logical subsystems are compatible. If one or more incompatible interfaces
are detected, the systems architect/integrator requests the responsible engineering team to review and
update their model appropriately. After the engineering teams complete the request, the systems
architect/integrator can make another attempt to integrate the models.
Although the VCCS has four logical subsystems overall, the following material focuses on integrating only
two of them: the Cooling System and the CP System. The model with all logical subsystems integrated is
available in <the installation folder of the modeling tool>\samples\MagicGrid; for example, C:\Program
Files\Cameo Systems Modeler 2021x\samples\MagicGrid.
Who is responsible?
The system configuration structure can be captured by the Systems Architect or Systems Engineer, who is
the head of the whole systems engineering project and is responsible for the smooth integration of the
subsystems and their components into the whole, the same person who owns the LSA model of the
SoI. This task can also be performed by the Systems Integrator, a subordinate of the Systems Architect.
The integrated structure model of the system configuration can be captured by utilizing the infrastructure
of the SysML bdd.
The structure decomposition map enables users to review and update the integrated structure model in a
compact form.
The interface compatibility can be verified by specifying the logical subsystems communication in the
SysML ibd.
Tutorial
• Step 1. Creating and organizing a model for system configuration structure
• Step 2. Getting ready to capture the structure of the system configuration
• Step 3. Capturing the integrated structure of the system configuration
• Step 4. Verifying interface compatibility
For this, you must create another model. In general, this model can be called the system configuration
model. Note that there can be more than one system configuration model within a single solution domain;
however, we will focus on a single one.
1. Start sharing the LSSA models of the Cooling System and the CP System.
• The LSSA models of all subsystems of the VCCS should be shared in this step.
• For more information on this topic and the topics mentioned in steps 2 and 3, refer to
the latest documentation of your modeling tool.
2. Create a new model. It can be named VehicleCCS Configuration.mdzip. This is the configuration model
of the Vehicle Climate Control System.
3. Use the LSSA model of the Cooling System as read-only in the configuration model of the VCCS.
Because it has already been used in the LSSA model of the Cooling System, the problem domain
Grey color element names within the used model indicate that elements cannot be modified.
This is because the external model is used in the read-only mode.
5. Right-click the Model package (this is the default name of the root package) and select Create
Element.
6. In the search box, type pa (the first two letters of the element type Package), and press Enter.
7. Type 3 Configuration Domain to specify the name of the new package and press Enter (see the figure in
step 9).
8. Right-click the 3 Configuration Domain package and select Create Element.
9. Repeat step 6.
10. Type 2 System Structure to specify the name of the new package and press Enter.
A bdd created under the 2 System Structure package can be used for capturing this block, as well as for
performing the next steps of this cell tutorial.
1. Create a bdd:
a. In the Model Browser, right-click the 2 System Structure package you created in step 1 of this cell
tutorial, and select Create Diagram.
b. In the search box, type bdd (the acronym for SysML block definition diagram), and then press
Enter. The diagram is created.
c. Type VCCS Configuration Structure to specify the name of the new diagram and press Enter again.
2. Display the VCCS block from the LSA model on the diagram:
a. In the Model Browser, select the VCCSblock (you might need to expand the2 Solution Domain
and 2 System Structure packagesfirst).
b. Drag the selection to the newly created diagram pane. The shape of the VCCS block is displayed
on the diagram.
a. Select the VCCS block, if not yet selected, and click the Generalization button on its smart
manipulator toolbar.
b. Click an empty place on the diagram below. A new unnamed block is created, and its shape is
displayed on the diagram pane.
c. Type VCCS Configuration to specify the name of the new block and press Enter.
As a result, the selected proxy port is redefined. From there, it is no longer decorated with
the caret symbol (“^”), which indicates the inheritance. Don't change anything.
d. Row by row, redefine the rest (the order of items may differ from what you see in the following
figure).
e. Click Close.
When specifying the system configuration structure, the blocks which represent the logical subsystems
must be taken from the LSSA models; that is, the Cooling System Architecture block from the LSSA model of
the Cooling System (the Cooling System Solution.mdzip file), and the CP System Architecture block from the
LSSA of the CP System (the CP System Solution.mdzip file). Be sure you haven't taken the blocks
representing the logical subsystems from the LSA model. These blocks have neither internal structure no
behavior; remember, they were created to identify the work packages.
The modeling tool actually enables you to prevent the selection of inappropriate blocks. For this, you need
to narrow the scope for type selection down to one or more packages. In this case, these are the 2.1
Cooling System Solution Domain and 2.2 CP System Solution Domain packages from the used models, as
shown in the following figure. Since you are aware of how to narrow down the scope (see step 3 of
System Structure tutorial, if you need to refresh), we assume that you do this on your own.
After you close the dialog, the VCCS Configuration Structure diagram should look very similar to the one
below.
If you decide to display the deeper structure (right-click the Cooling System Design block and select Display
> Display Related Elements), the diagram should look as follows.
1. In the open diagram, select the shape of the VCCS Configuration block.
2. Right-click the selection and then select Create Diagram.
3. In the search box, type sdm (the acronym of the structure decomposition map), and then press
Enter. The map is created.
If you don’t see any results, click the Expert button below the search results list. The list of
available diagrams expands in the Expert mode.
4. Type VCCS Configuration Structure to specify the name of the new map and press Enter again.
If your modeling tool version is lower than 2021x, you should see the cooling and cp part
properties twice (see the following figure). This is because the structure decomposition map in
these versions displays the inherited part properties even if they are redefined.
To remove the inherited part properties from the map, select them and press Delete.
Remember that communication is possible only if these logical subsystems have compatible interfaces. For
this reason, we can state that the systems architect performs the interface compatibility verification by
specifying the interactions within the particular configuration of the SoI.
You already know that interactions between the internal parts of the system can be specified in the SysML
ibd. So let's create one and check whether the Cooling System and CP System, two logical subsystems of
the VCCS, can successfully communicate.
a. In the VCCS Configuration Structure diagram you created in step 2 of this cell tutorial, select
the shape of the VCCS Configuration block.
b. Click the SysML Internal Block Diagram button on its smart manipulator toolbar.
c. A new blank diagram is created.
d. In the Display Parts/Ports dialog, do the following:
e. In the Model Browser, select the newly created diagram and press F2 to enter the name edit
mode.
f. Type Subsystems Communication in VCCS to change its name and press Enter.
a. Right-click the shape of the cooling property and select Display > Display Parts/Ports.
b. In the Display Parts/Ports dialog, do the following:
The selected proxy ports display on the shape of the cooling part property.
As you can see, there are two pairs of compatible proxy ports: one pair typed by the
InternalControl interface block, and the other by the InternalResponse interface block. Each
pair has one proxy port for data input, and one for data output.
3. Create connectors between the part properties, over compatible proxy ports:
a. Select the p2 proxy port on the shape of the cp part property and click the Connector button
on its smart manipulator toolbar.
b. Click the p3 proxy port on the shape of the cooling part property.
c. Follow steps a and b to create a connector between the other pair of compatible proxy ports.
4. Specify the Start signal as the item flowing over the connector between the cp and cooling part
properties:
b. Drag the selection onto the connector between two proxy ports typed by the InternalControl
interface block.
5. Follow step 4 to specify the SysOK and SysNotOK signals as items flowing over the same connector,
and the coolStatus signal as the item flowing over the connector between cooling and cp part
properties.
As you can see, no incompatible interfaces were identified, and we can state that the Cooling System and
CP System can successfully communicate within the VCCS.
After you specify the interactions of the logical subsystems with the outside, your Subsystems
Communication in VCCS diagram should look like the one below.
• The integrated model of the system configuration enables you to calculate more precise values of
system parameters than in the LSA model. Chapter System Configuration Parameters describes
how to do this.
• Moreover, the specification of logical subsystems communication enables their behavioral models to
exchange signals (so far, it was possible to send and receive signals only within the scope of a single
logical subsystem). Therefore, you can switch to analyzing the integrated behavior of the whole
SoI , which is described in Chapter System Configuration Behavior.
The behavior of the system of interest integrates the behaviors of its logical subsystems, identified in the
LSA model (see Chapter System Structure).
Once you build the integrated structure model of the entire SoI (see previous chapter), you have its
integrated behavior model as well. No modeling effort is required in this cell. Its main purpose is to analyze
the integrated system behavior model and verify it.
Who is responsible?
The integrated behavior of the system configuration can be analyzed and verified by the Systems
Architect or Systems Engineer, who is the head of the whole systems engineering project and is
responsible for the smooth integration of the subsystems and their components into the whole, the same
person who owns the LSA model of the SoI. This task can also be performed by the Systems Integrator, a
subordinate of the Systems Architect.
How to model?
Remember that this cell is not about modeling. It is about integrated model analysis. For this, the
simulation capabilities of the modeling tool can be exploited. By executing the model, you can simulate
the behavior of the whole SoI and verify if it is as expected.
The simulation animation enables you to monitor the execution progress. It marks the current, last visited,
and all other visited element shapes. The following figure depicts the animated moment of model
execution, when the CP System Architecture block sends out the Start signal via the p2 proxy port and the
Cooling System Architecture block is about to receive it. Note that the Subsystems Communication in
VCCS diagram helps; it specifies where the Start signal is sent.
1. Once ignition starts, the CP System initializes all other subsystems of the VCCS (in this case, the
Cooling System only).
2. In response, the Cooling System performs the self-check and informs the CP System if it can start.
3. After the CP System receives the status from the Cooling System, it decides whether or not they can
both start.
To simulate the behavior of the whole configuration of the SoI, a relevant block must be indicated as the
simulation context. In this case, it is the VCCS Configuration block, shown in the following figure.
If the system behavior has been defined in LSA model and it is still assigned as the classifier
behavior of the VCCS block (the super-type of the VCCS Configuration block), during the simulation it
will conflict with the integrated behavior of the VCCS Configuration block.
To prevent this conflict, go back to the LSA model and set the Classifier Behavior property value to
<UNASSIGNED> for the VCCS block (refer to Chapter System Behavior). If you cannot update the
LSA model (for example, you don't have relevant permission), you can define a fake system
behavior for the VCCS Configuration block (such as the state machine with a single default state). As
a result, the fake system behavior becomes the classifier behavior, which doesn't conflict with the
integrated one during the simulation.
3. Click the Auto Open Diagrams button to enable the mode, in which currently executed
diagrams open automatically.
4. On the toolbar of the Simulation panel, click the Start button . The simulation sessions are created
for the state machines of each block that is a part of the VCCS Configuration block. In this case, these
are the state machines of the Cooling System Architecture and CP System Architecture blocks.
As a result of the manually fired transition, the CP System Architecture block enters the Initializing state. On
entering that state, it sends out the Start signal via the p2 proxy port (see the following figure).
As the Subsystems Communication in VCCS diagram defines, the Start signal is received by the Cooling
System Architecture block.
The CP System Architecture block accepts the coolOK signal, reads its attribute value, and decides whether
or not both subsystems can switch to the Idling state. For this, it performs the Evaluate Status activity.
As a result, the CP System Architecture block sends out either the SysOK or SysNotOK signal via the p2 proxy
port (see the following figure). As the figure shows, the same signal in each case is also sent internally,
this time to fire one of the transitions of the CP System Architecture block: either to the Idling or to the Off
state.
This analysis proves that the integrated system behavior model meets the relevant system and subsystem
requirements.
The system configuration model enables you to relate the calculation methods from different levels of
detail, such as one from the system with some from the subsystem level. You can define more specific
input values and get more precise calculation results than in the LSA model. For example, in the LSA
model, you had to specify the energy consumption of the Cooling System, while in the system
configuration model it can be derived by summing up the energy consumption of its logical components.
Who is responsible?
The system configuration parameters can be analyzed and verified by the Systems Architect or Systems
Engineer, who is the head of the entire systems engineering project and is responsible for the smooth
integration of the subsystems and their components into the whole; the same person who owns the LSA
model of the SoI. This task can also be performed by the Systems Integrator, a subordinate of the Systems
Architect.
How to model?
Usually you don't need to capture any calculation method in the system configuration model. You've done
that in the LSA model and also in the LSSA models. You've also defined the system, subsystem, and
component parameters there. You don't need to re-capture them in the system configuration model as
well.
However, you may need to update the bindings. For example, you might need to bind a constraint
parameter specified in the LSA model to the value property created in the LSSA model. In this case, the
infrastructure of the SysML parametric diagram helps a lot.
First of all, redefine the totalEnergyConsumptionVCCS value property inherited from the VCCS block. The
redefinition is not necessary for calculations, as you can perform them with an inherited value property.
However, you need to redefine the value property to be able to create a satisfy relationship from the value
property to the relevant system requirement.
1. Open the VCCS Configuration Structure diagram you created in step 2 of this cell tutorial.
2. Right-click the VCCS Configuration block and select Specification.
3. On the left of the open dialog, click Properties.
4. Under the Value Properties category, select the totalEnergyConsumptionVCCS value property click
the Redefine button below.
5. As a result, the selected value property is redefined and is now no longer decorated with the caret
symbol (“^”), which indicates the inheritance. Don't change anything.
1. In the Model Browser, right-click the block and select Create Diagram.
2. Select SysML Parametric Diagram in the Create Diagram dialog below. A new diagram is created, and
the Display Parameters/Properties dialog is opened.
3. In the dialog:
a. Leave the check box near the :Total Energy Consumption constraint property selected.
This constraint property defines the method for calculating the total energy consumption
of the VCCS. You already specified it for the VCCS block in the LSA model. It belongs to the
VCCS Configuration block, too, because it is a sub-type of the VCCS block and inherits all its
features from the VCCS block, including the constraint properties.
b. Click the button near the cooling : Cooling System Architecture part property to expand its
contents.
c. Click to select the check box near the /totalEnergyConsCool : kWh value property.
d. Click the button near the cp : CP System Architecture part property to expand its contents.
e. Click to select the check box near the energyCons : kWh value property.
As you don't have yet the method defining the energy consumption of the CP System,
you can take the value property defined in the LSA model. The same logic applies for other
logical subsystems.
f. Follow steps d and e to select the energyCons : kWh value properties of the heating : Heating
System and hmi : HMI System part properties.
g. Make sure the check box near the /totalEnergyConsVCCS : kWh value property is selected.
h. Make sure everything else is unselected.
i. Click OK to close the dialog.
4. In the Model Browser, type VCCS Configuration Energy Consumption to name the newly created
diagram.
Once you're done, the VCCS Configuration Energy Consumption diagram should look like the following
figure.
1. Select the constraint property and click the Display All Parameters button on its smart
manipulator toolbar. Parameters and binding connectors to corresponding value properties are
displayed on the diagram.
5. Repeat steps 2 to 4 to establish another binding connector between the energyCons value property of
the CP System Architecture block and the energyCons2 parameter.
6. Repeat steps 2 to 4 to establish one more binding connector, this time between the
/totalEnergyConsVCCS value property of the VCCS Configuration block and the totalEnergyCons
parameter.
Now, if you run the simulation on this diagram, you can enter diverse values of energy consumption for
subsystems and components, and see the result. The result values can be stored in the model (see step
7 in the System Parameters tutorial).
To ensure that the system configuration model is complete, and all system requirements are considered
and implemented, you need to perform the analysis and specify traceability relationships from the system
configuration model to the system requirements specification. These are satisfy relationships.
Who is responsible?
Traceability relationships can be specified by the Systems Architect or Systems Engineer, who is the head
of the entire systems engineering project and is responsible for the smooth integration of the subsystems
and their components into the whole.
How to model?
As you already know, a Satisfy Requirement Matrix provides the best infrastructure for specifying
satisfy relationships. The matrix is pretty much the same as the one created in the LSA model. Only the
column scope is different: here you should select the VCCS Configuration block instead of the VCCS block.
The matrix in the following figure shows that a few system requirements are not yet satisfied. For this,
you need to build the LSSA of the Heating and HMI Systems and then integrate them into the system
configuration model.
Steps for specifying the traceability relationships are equivalent to steps of the Traceability to System
Requirements tutorial:
• Step 1. Creating a matrix for capturing satisfy relationships
• Step 2. Capturing satisfy relationships
As you can see in the following table, the implementation domain is only partially covered by the
MagicGrid framework. The framework only defines how to specify implementation requirements for the
SoI. However, detailed physical design of the SoI is not a part the MagicGrid framework. The next steps of
the SoI development can be accomplished by using such software as electrical and mechanical CAD tools
or automated code generation tools, among others.
Implementation Requirements
What is it?
In order to implement the system of interest, you first need to have detailed requirements to follow while
producing the system's detailed physical design. These requirements are based on the logical architecture
of the system of interest, including the logical architectures of all its subsystems and even more precise
units.
The implementation requirements specification is given to the engineers of various disciplines, who are
responsible for designing different aspects of the system under implementation.
Who is responsible?
In the modeling tool, an item of the implementation requirements specification can be stored as a SysML
requirement, which has a unique identification, name, and textual specification. Implementation
requirements must be formal and written down by following certain guidelines. These may include writing
in short and clear sentences only; avoiding conditional keywords, such as if, except, as well; use of
the shall keyword; and incorporating tables. For more information on writing good textual requirements,
refer to the INCOSE Systems Engineering Handbook.
As shown in the following figure, each implementation requirement should refine one or more elements
from the system configuration model, or be derived from at least one requirement from the solution
domain. For this, a matrix for specifying both types of relationships can be created (similar to the one
in step 4 of Subsystem Requirements).
Having derivation relationships among requirements in different domains, you can easily trace from very
detailed requirements to very abstract requirements and see what items determine the creation of other
items. To perform this impact analysis (either downstream or upstream), we recommend utilizing the
infrastructure of the Requirement Derivation Map, one of the predefined relationship maps in
the modeling tool.
Tutorial
Steps of this cell tutorial are adequate to steps of the Subsystem Requirements tutorial:
• Step 1. Creating and organizing a model for subsystem requirements
• Step 2. Creating a diagram for subsystem requirements
• Step 3. Specifying subsystem requirements
• Step 4. Specifying traceability relationships
The difference is that in step 4 you establish traceability relationships to the subsystem requirements for
the Cooling System and to the relevant elements of the system configuration model.
What's next?
You are ready to develop the detailed physical design of the system. These activities are outside the scope
of the MagicGrid approach.
Reliability is the ability of a functional unit to perform a required function under given conditions for a
given time interval (ISO/IEC 2382:2015 Information Technology). Safety is freedom from unacceptable
risk (IEC 61508:2010 EEPE safety-related systems).
SysML, as one of the key MBSE components, has a good foundation for capturing requirements,
architecture, constraints, views, and viewpoints. However, SysML does not provide the necessary
constructs to capture safety and reliability information in the system model. The Cameo Safety and
Reliability Analyzer plugin adds support for those missing constructs. The following safety and reliability
standards are supported:
• The failure mode, effects, and criticality analysis (FMEA) according to IEC 60812:2006 standard
• Hazard analysis according to the following medical standards:
• IEC 62304
• ISO 14971:2007, Corrected version 2007-10-01 (Medical devices - Application of risk
management to medical devices)
The ISO 26262 Functional Safety plugin, used in conjunction with the Cameo Safety and Reliability
Analyzer plugin, supports ISO 26262 (Road vehicles – Functional safety) standard.
This annex describes how FMEA, supported by the Cameo Safety and Reliability Analyzer plugin, is used
to enrich a systems model created using the MagicGrid method with safety and reliability information.
The figure below depicts the general safety and reliability analysis workflow. Reliability and safety
analysis is performed against the systems model (stakeholder needs, system behavior, and structural
parts) and identified as separate items, which are called FMEA items when the FMEA method is used.
These items are then ranked and the most critical are addressed by introducing new safety and reliability
requirements. Subsequently, changes to the architecture and design of a system are done by introducing
new behaviors and altering the structure of the system to support the identified safety and reliability
requirements. Newly introduced modifications to the systems model need to undergo the same safety and
reliability assessment.
Safety and reliability analysis is either performed by a safety engineer or a systems engineer.
Traditional FMEAs are done in a spreadsheet-like environment, supported by the Cameo Safety and
Reliability Analyzer plugin as a primary way to manage FMEAs. Each row in the table is called an FMEA
item which references (or semantically groups) classical FMEA elements, such as failure cause, failure
mode, local and final effects, and mitigation.
The Black Box conceptual FMEA table contains the following columns:
Failure Mode An element describing the specific manner in which a system could
potentially fail to meet the design intent.
The following figure shows an FMEA table supported by the Cameo Safety and Reliability Analyzer plugin,
which represents the conceptual FMEA. The item is the :VCCU unit, which is the system being modeled.
Every FMEA item refines safety and reliability requirements from stakeholder needs. For example, the
F-2 FMEA item refines the SN-1.3.2.2 Biofouling stakeholder requirement. The refining FMEA item
identifies how the :VCCU unit can fail to meet the need for passengers of a car to not be exposed to any
toxic materials accumulated in the climate control unit:
• First, potential causes of failure are identified; in this particular case, direct contact of a passenger
with toxic materials accumulated in the climate control unit.
• Then, failure modes are identified; in this particular case, passengers not being able to operate
the :VCCU unit (since the unit produces toxic materials).
• Local and final effects of failure are either introduced or reused from the library as they tend to
repeat across product lines or different products.
• Finally, new safety or reliability requirements are introduced; in this particular case, a requirement
to have air filters so that toxic materials would not accumulate in the climate control unit.
As already mentioned, FMEA items can have a name. The name is a resumptive sentence that conveys the
essence of analysis performed at concrete FMEA items. The purpose of the FMEA item name is to optimize
the search of FMEA items in the model to promote the reuse and facilitate the management of FMEA
items.
Causes may not be specified at all if for any reason or cause within the created system a failure mode
occurs and only that fact is important to introduce a mitigation safety or reliability requirement (see the
F-1 FMEA item). The newly introduced safety and reliability requirements then need to be linked to the
newly created or updated behavioral or structural models in both Black Box, White Box, LSA, Subsystem,
or Component views.
Safety and reliability analysis workflow is repetitive, thus failures that originate at the Black Box view can
resonate through the whole SoI, from the problem domain down to implementation. In order to capture
the failure scenarios, FMEA cause-effect chains are used that can be depicted using Relation Map
diagrams. For example, the Biofouling Relation Map (see the following figure) depicts the model elements
and FMEA items that originate during FMEA analysis starting from the SN-1.3.2.2 Biofouling stakeholder
requirement.
The Black Box functional FMEA is depicted in the following figure. As you can see, the Item column is still
referencing :VCCU, just as in the conceptual FMEA. However, the Subsystem column represents object
flows that are analyzed for potential failures. The source for this analysis is the activity diagrams specified
for use cases (see the Use Cases section). The Provide Comfortable Temperature activity from the Use
Cases section is shown below the functional FMEA table. When performing a functional FMEA, all
incoming and outgoing flows into the swimlane representing :VCCU, as well as actions being performed by
it, are being analyzed for potential failures (e.g., how would the system perform if one of the incoming
flows that flows into the given action did not produce the expected output?).
In this particular example, we only focus on object flows related to the Check System and Reach Desired
Temperature actions, but the same can also be done for control flows and actions. The flows being
analyzed are color-coded in orange in the activity diagram below the FMEA table. The actions that these
flows connect are represented in the Source and Target columns in the functional FMEA table. The Refines
column represents the analyzed use case. The Mitigation column has the same purpose as in the
conceptual FMEA table.
The F-7 FMEA item analyzes the object flow coming from the Provide Air into the Reach Desired
Temperature action by assessing the possible impact of the failure to receive air to the system when it is
trying to reach the desired temperature, which is captured as the cause in the Cause of Failure column in
the FMEA table (VCCU cannot suck air from cabin). As a result, the failure mode Loss of function occurs,
To demonstrate how safety and reliability requirements are addressed at this level or downstream, let's
have a look at the newly introduced Provide Limp Mode safety requirement. The original MagicGrid activity
diagram for the Provide Comfortable Temperature is shown as follows.
To address the Provide Limp Mode safety requirement, the new :VCCU function called Start Climate Control in
Fallback Mode @72F is introduced. This mode would provide the required default 72 °F temperature as long
as the :VCCU has not yet accepted the command to start or received the desired temperature.
The table below lists safety and reliability requirements. Requirements 8 and 9 are created as a result of
the FMEA analysis at the White Box level (see the sections below).
Safety and reliability requirements can be addressed at all levels, from the problem statement to the
component design. For example, the safety requirement 1 Use Flame-Resistant Materials cannot be
addressed at the Problem level since this level does not contain actual system design. This requirement
could be addressed at the logical subsystem level since specific materials used in the design of a system
are known at this level. Another example is the requirement 2 Air Filters, which can be addressed at the
White Box level and downstream as well.
The original MagicGrid activity diagram for the Reach Desired Temperature activity (at the White Box view) is
depicted below. The air is flowing directly to the actions for drawing air from the cabin.
After making the aforementioned changes to the model, the Biofouling Relation Map is updated with the
newly introduced model elements that satisfy the 2 Air Filters safety requirement.
For example, the F-9 FMEA item analyzes how the :Filtering subsystem can fail to protect the passenger
from contact with toxic materials that may accumulate in the :VCCU, resulting in possible death from fire or
poisoning from smoke due to a clog in the filter caused by external factors such as dust, leaves, or trash.
As a result, the failure mode Reduction of function occurs, meaning the reduced ability of :Filtering
subsystem to filter the air, resulting in local effects on the :VCCU (overloading or catching on fire), and final
effects on the passenger, such as being burned, poisoned by smoke, or having an accident while driving,
among others. To mitigate these risks a new safety requirement is created to detect any clog in the :Filterin
g subsystem.
The newly introduced safety requirements need to be addressed by making modifications to the systems
model. The following figure depicts the Test Air Flow function that addresses these two requirements by
testing incoming air flow. The diagram also contains the other safety requirements introduced at the Black
Box level that are addressed and satisfied by appropriate functions.
These requirements, just like safety and reliability requirements in the problem domain, need to be
addressed by making modifications to the model. For example, to address the SR-1.12.7 Air Filters
The «abstraction» relationship is used to declare that the Filtering System in the LSA is derived from the
conceptual subsystem called Filtering in the problem domain analysis model. This relationship is illustrated
in the LSA to Problem Domain matrix provided below.
where energyCons5 constraint parameter may stand for the energy consumed by the Filtering System. The
energyCons value property needs to be created for the Filtering system and an additional energyCons5
constraint parameter specified for the Total Energy Consumption constraint block. Once defined, the binding
between the former value property and the constraint parameter needs to be established to enable the
constraint expression to perform calculations on the modified model.
After these changes are complete it is time to specify the solution architecture of Filtering System and
revisit other VCCS subsystems in order to ensure integrity at the system level.
The Cooling subsystem has already specified interactions for exchanging the refrigerant. The physical
conditions of the refrigerant are already captured (see following figure). However, the SR-1.12.1 Use Flame-
Additional Cooling Subsystem physical requirement called SSR-1.1.4 Use Flame-Resistant Refrigerant is
introduced to address the SR-1.12.1 Use Flame-Resistant Materials safety requirement.
Subsystem Requirements
Let's say that the engineering team working on the solution architecture of the Filtering System receives
the following subsystem requirements from the System Architect:
Matrices and maps can be used to establish and review the cross-cutting relationships between
the :Filtering subsystem requirements and system requirements. The matrix below captures which more
concrete :Filtering subsystem requirements were derived from what system requirements.
Subsystem Structure
The internal structure of the Filtering System can be identified, then operations among its components,
and how logical components of the Filtering System interact with other subsystems of the same SoI can
be specified. To find the detailed steps refer to Chapter Subsystem Structure.
As defined by the subsystem requirements and based on the engineering team experience, the Filtering
system shall be composed of:
• Fan
• Membrane Type Particle Filter
• Pressure Sensor
• Voltage Comparator With Threshold
It should be noted that there is a need for the system to be constantly aware of filter status according to
LSA SSR 3.2.1 Filter Status requirements group. To be able to operate securely the Filtering System shall
monitor if the filter is ripped, clogged, and the severity of the clogging. Therefore, the pressure sensors are
installed before and after the air has blown through the filter. Then the pressure information is compared
by three dedicated voltage comparators to determine the status of the filter.
In this step, we focus on specifying interactions between components of the Filtering System and outside
of the subsystem. To specify interactions between subsystem components the SysML internal block
diagram (ibd) is used as shown in the following figure. An ibd is created for the Filtering System
Architecture block. As the procedure in step 5 of the Subsystem Structure tutorial suggests, first, we start
specifying interactions via inherited ports:
1. One for letting the cabin air and its pressure flow into the Filtering System that is consumed by :
Membrane Type Particle Filter and before : Pressure Sensor components.
2. Second for letting the filtered cabin air out from the : Fan of the Filtering System.
3. Another dedicated to control the : Fan by passing over the signals: Fan1, Fan2, Fan3, Fan4, and Stop.
4. The last one is dedicated to emit the signals indicating the state of the Filtering System from voltage
comparators out of the subsystem.
Connectors are created between compatible ports to convey the following interactions:
1. The before : Pressure Sensor converts air pressure to an electrical signal (voltage) proportional to the air
pressure before filtering.
2. The : Membrane Type Particle Filter provides filtered air to : Fan and filtered air pressure to after :
Pressure Sensor.
3. The after : Pressure Sensor consumes filtered air pressure and produces the voltage signal proportional
to the air pressure after filtering.
4. The filtered air is consumed by : Fan in order to be circulated out of the system.
5. Pressure sensors produce the voltage signals to clogModerate : VoltageComparatorWithThreshold,
clogHigh : VoltageComparatorWithThreshold, and rip : VoltageComparatorWithThreshold components
where voltage signals of air are compared with the present voltage reference, called threshold before
and after the filtering.
After identifying interactions between the components and the outside of the SoI, the next step is
to update the Filtering System Structure bdd diagram to display new proxy ports on the blocks that capture
the Filtering System Architecture and its components (see the following figure).
Subsystem Behavior
After identifying and capturing the structural architecture of the Filtering system, the next step is to
continue with behavioral architecture modeling. The SysML state machine and activity or sequence
diagrams are used to capture the behavior of the Filtering System.
To capture the main states of the Filtering System the SysML state machine diagram is used, displayed
in the following figure analogously as the Cooling subsystem. The transitions between states are triggered
by a signal event, such as Start between the Off and On states or SysNotOK and SysOK signals between
Initializing, Off and Operating states.
Let’s say the engineering team working on the solution architecture of the Filtering System has identified
the following set of states in which the Filtering System can exist during the VCCS operation:
1. Off
2. On:
a. Initializing
b. Operating
filterStatusCloggedM stands for filter Status Clogged Moderately, and filterStatusCloggedS stands for
filter Status Clogged Severely.
1. Filtering Normally
2. Partially Clogged
3. Severely Clogged
4. Ripped
To address requirements under the SSR-3.2.2 Fan States grouping requirement, another state machine is
created for Fan component of the Filtering System (see the following figure). The Fan State diagram
depicts the power states in which Fan can exist during system operation, such as:
1. Off
2. Blowing1
3. Blowing2
4. Blowing3
5. Blowing4
These states are triggered by signal events Fan1, Fan2, Fan3, and Fan4 to change the power of the Fan.
The Fan also can be turned off any time despite its Blowing state. The Stop signal is used for this transition
The number along the Blowing state name represents the power of the fan, the bigger number
means a more powerful mode of the fan. Signal names that trigger these states are named
analogously for each of the states.
As mentioned in the step 5 of the Subsystem Behavior tutorial, every logical subsystem of the SoI can
perform one or more behaviors related to one or more of its states. The internal behavior of the Filtering
System is captured using the SysML activity diagram. To indicate that the Filtering System performs a
self-check and sends out the filterStatus signal with an appropriate attribute value, an activity diagram is
created that is specified as a do behavior on the Initializing state.
To specify that the CP System evaluates the status of all subsystems and sends the SysOk and SysNotOK
signals the CP System Evaluate Status state machine diagram should be updated. The following figure
captures the final view of the Filtering System States state machine diagram.
The change has to be reconciled with other engineering teams to ensure integrity at the system level.
Subsystem parameters are used to capture quantitative characteristics of the Filtering logical subsystem
that can be measured. They are used to calculate MoEs for that logical subsystem to satisfy non-functional
quantitative subsystem requirements. Using the capabilities of the modeling tool, the model can be
executed to calculate MoEs using mathematical expressions to determine whether quantitative
requirements are satisfied or not. (See the Subsystem Parameters section.)
Specifying subsystem parameters for calculating the total energy consumption for filtering
According to the subsystem requirements specification and the MoEs identified for the Filtering System
captured in the problem domain and downstream, the formula for calculating the total energy consumed
by the Filtering System needs to be modeled. The SysML block definition diagram (bdd), called System
Parameters for Total Energy Consumption for Filtering, is used to specify constraint expressions and
parameters necessary to define totalEnergyConsFilter value property.
The Total Energy Consumption for Filtering constraint block depicted in the following figure has seven input
parameters, each for the energy consumption of a single component of the Filtering System, and therefore
requires seven component parameters to be defined in the model. Value properties should be specified for
each block that represents components of the Filtering System.
Let’s say the total energy consumption of the Filtering System equals the sum of energies consumed by
all its components. The constraint expression can be defined as follows:
1. totalEnergyCons stands for the total energy consumed by the Filtering System
2. energyCons1 may stand for the energy consumed by the Fan
3. energyCons2 may stand for the energy consumed by the Membrane Type Particle Filter
4. energyCons3 may stand for the energy consumed by the before : Pressure Sensor
This is a simple sensor model, converting input pressure in the range 0-2 atmospheres (0-200000 Pa) into
the voltage output signal in 1-10V range, that is depicted using parametric diagrams presented in the
following figure.
The second figure illustrates the simplified model for fan energy consumption depending on the : Fan state
and the input pressure, which in turn depends on the pressure drop in the membrane filter permeability).
The consumption is 37 Watts times the : Fan blowing intensity (Blowing1-Blowing4) times the linear
correction factor depending on the input pressure drop.
This is a model for a voltage comparator with a threshold. When the voltage at input1 is greater than
input2 + threshold, an output signal is fired.
The next step is to establish traceability relationships from the elements that capture the LSSA of Filtering
System to subsystem requirements.
According to the Traceability to Subsystem Requirements section the cross-cutting relationships (such as
satisfy) need to be defined in order for subsystem requirements to be fulfilled. As you can see in the
following figure, the satisfy requirement matrix called LSSA to Subsystem Requirements is completely
fulfilled, meaning that all subsystem requirements are satisfied by one or more architecture elements.
For example, the F-11 FMEA item analyzes how before : Pressure Sensor can fail to protect the passenger
from accidents, such as burns from fire or poisoning due to adverse conditions formed in the VCCU, such as
a clogged filter or VCCU on fire, that are called local effects of failure. These conditions can be caused by
wire breakage in the before : Pressure Sensor, which would result in an inability to provide data about the air
pressure to other subsystem parts. As a result, the failure mode Loss of Function occurs, meaning the lost
ability to determine the state of the pf : Membrane Particle Filter. To mitigate the risk a new safety
requirement is introduced to handle unknown filter status (see the SSR-4 Handle Unknown Filter
The Filtering System logical subsystems FMEA table contains the following additional column compared
with conceptual FMEA tables in the problem domain:
As you can see, no incompatible interfaces were identified, and we can state that the Filtering System can
successfully communicate within the VCCS.
Model-based engineering practices have recently evolved beyond engineering a single system. In this age
of innovation, system thinking can be applied in the system of systems (SoS) environment to deal with
new challenges, such as autonomous traffic control, industry 4.0, the internet of things, etc.
The SoS is a SoI, whose elements are systems themselves; multiple organizations are involved in design,
maintenance, and operation of the SoS.
Therefore, when designing a SoS it is important to establish a digital environment for multiple
organizations to interact, especially when transitioning from SoS to systems architectures (SAs) (see the
following figure). In most cases this is a collaboration between the contracting authority and a contractor,
or the Original Equipment Manufacturer (OEM) and a supplier. This annex provides a detailed approach for
ensuring the digital continuity from SoS to SAs in the model-based environment.
In this annex, we only focus on the UAF Resources domain, which captures logical SoS architectures and
how they serve in the achievement of SoS capabilities. However, the UAF does not specify ways and
means to define the architecture for a single system. For this, we utilize MagicGrid with SysML.
The system context or operating environment determines the external view of the SoI. Therefore, the
collection of elements in a particular system context includes the SoI itself and external systems (natural or
artificial), as well as users (humans, organizations) that interact with the SoI to exchange data, matter,
energy, or human resources.
As defined by MagicGrid, the system context is captured in the model as a SysML block. The SoI, external
systems, and supposed users are also captured as SysML blocks. While composite association relationships
enable modelers to relate them to a particular system context, the SysML internal block diagram provides
the infrastructure to display the participants of the system context and their interactions.
The system context of the SoI is initially defined in the SoS (UAF) model as the Resources Structure
viewpoint, which captures that SoI along with other systems within the same SoS. The System Context
view in the SysML model can be considered a subset of the Resource Structure viewpoint (see the
following figure).
Therefore, the block that captures the system context of the particular SoI in the SA (SysML) model
becomes a subtype of the capability configuration in the SoS (UAF) model. As a consequence, that block
inherits all the parts of the related capability configuration. The parts that participate in the system
context of the SoI are redefined with SysML blocks that capture copies of the SoI, actors, or external
systems in the SysML model (see the following figure). The redefinition of parts is necessary for further
modeling: this enables a modeler to update the system context information without modifying the
SoS (UAF) model. For example, you may need to add new ports or more specific ones than those defined
in the SoS (UAF) model.
Stakeholder needs may include primary user needs, system-related government regulations, industry
standards, policies, procedures, internal guidelines, etc. They can be captured as SysML requirements,
which enable modelers to store the textual information in the SysML model. Stakeholder needs can be
grouped by the source they came from and categorized into functional and non-functional needs. The
infrastructure of the SysML requirements diagram or table can be utilized to display their hierarchy.
Stakeholder needs can be captured by interviewing stakeholders, giving them questionnaires, discussing
needs in focus groups, or studying documents written in diverse formats. In addition to these information
sources, the UAF model of the SoS can serve as input to the stakeholder needs as well. To be more precise,
the Resource Processes, Resource States, and Resource Interaction Scenarios Viewpoints can be used for
identifying functional stakeholder needs, while the Resources Measurements Viewpoint can be used for
non-functional (see the following figure).
When functional stakeholder needs are captured, SysML refine relationships can be established from
SysML requirements that capture the stakeholder needs to the relevant functions, states, or interactions in
the UAF model (see the following figure).
Measurements that are owned by the system that becomes the SoI in the SysML model motivate the
creation of one or more non-functional quantitative stakeholder needs for that SoI. When these are
captured, SysML refine relationships can be established from them to the relevant measurements in the
UAF model (see the following figure).
When use cases and MoEs of the SoI are captured in the SysML model, SysML refine relationships can help
to convey which stakeholder needs these use cases and MoEs refine.
A SysML element that can capture a basic unit of the system functionality within the activity. It
represents some form of processing or transformation that will occur when the activity is executed
during the system operation. An action is represented as a round-cornered rectangle, with the name
displayed as a string inside that rectangle.
Activity
A type of behavioral SysML element that can contain a set of model elements, such as actions and
flows, and the activity diagram that represents these elements.
Activity diagram
A type of behavioral SysML diagram that can be used to describe the flow of control or the flow of
inputs and outputs among actions. Activity diagrams can be used to specify the black- and white-box
scenarios of the expected system functionality, and in combination with state machine diagrams to
design the system behavior.
Actor
A SysML element that can capture a role played by a person, an organization, or another system
when it interacts with the system of interest in the particular context. However, the MagicGrid
approach recommends using a block instead of an actor to capture these concepts, for the reasons
described in Use Cases.
Association
A type of SysML relationship that enables you to specify what actors interact with the system of
interest in the particular system context to invoke or participate in a use case. The notation for the
association is a solid line.
Binding connector
A special type of SysML connector that is used to represent an equality relationship between a
constraint parameter and a value property in a parametric diagram, in order to convey that the
constraint parameter receives the values from that value property. The notation for the binding
connector is a solid line.
The black box represents an external view of the system. During the system analysis from the black-
box perspective, the system is viewed in terms of its inputs and outputs, without any knowledge of
its internal structure and behavior.
The white box represents an internal view of the system. During the system analysis from the white-
box perspective, the functional decomposition of the system is performed in order to identi-
fy conceptual subsystems (also referred as functional blocks in other methodologies.
Block
A SysML element of definition that can capture a basic unit of the system structure. A block is
represented as a rectangle with a stereotype block preceding the name of the «block» in the name
compartment.
A type of structural SysML diagram that can be used to define features of blocks and relationships
between blocks, such as associations, generalizations, and dependencies. It captures the definition of
blocks in terms of properties and operations, and relationships such as a system hierarchy or a
system classification tree. Block definition diagrams can be used to specify the structure of a system
or subsystem, and to define the interfaces and constraints of that system or subsystem.
A special type of SysML action that can invoke another behavior: an activity, a state machine, or an
interaction. Call behavior actions enable you to decompose a higher-level behavior into a set of lower-
level behaviors.
A special type of SysML association that enables you to specify that one block is a part of another
block. The notation for the composite association is a solid line between two blocks with a black
diamond on the composite end and an open arrowhead on the part end. Drawing a composite
association between blocks creates a part property for the block that appears on the black diamond
end of the relationship; the part property can have a name and is typed by the block that appears on
the arrowhead end of the composite association.
Component
An elementary object of the system structure. Components are often grouped into subsystems of the
system; they are identified by decomposing these subsystems. A component can be captured as a
block in the model.
Connector
A type of SysML relationship that is used to represent communication between two part properties in
an ibd. The connector may be established between part properties through various kinds of ports (as
long as these ports are compatible); for example, two part properties connected through proxy ports
convey that they exchange matter, energy, or data that can flow between them over the connector,
through compatible proxy ports. The notation for the binding connector is a solid line.
Constraint block
A SysML element of definition that can capture a constraint expression (either an equation or an
inequality). The constraint expression enables you to constrain the value properties of blocks. The
variables of the constraint expression are called constraint parameters. These constraint parameters
receive their values from the value properties that are being constrained. The notation of the
constraint block is the same as for the block, but with the «constraint» stereotype before the name of
the element.
Constraint parameter
A variable that appears in a constraint expression of the constraint block. It is captured as a property
of the constraint block in the model, and is represented as a string in the parameters compartment of
that constraint block.
A usage of a constraint block in the context of some block or, in other words, a property of a block
typed by a constraint block defined somewhere in your model. It can be represented as a string in the
constraints compartment of that block in a bdd, or as a round-cornered rectangle in a parametrics
diagram. The name of the constraint property in both cases is displayed as a string followed by a
colon and the name of the constraint block which types that property; for example, mass : totalMass.
Control flow
A type of SysML relationship between a pair of actions. Control flows enable you to express the order
in which actions are performed in the associated activity. Control flow is represented as a dashed line
with an open arrowhead.
Decision/Merge
The decision node marks the start of an alternative flow in an activity. It is represented as a hollow
diamond, and must have a single incoming flow and two or more outgoing flows.
The merge node marks the end of the alternative flow in an activity. It is represented as a hollow
diamond, and must have two or more incoming flows and a single outgoing flow.
Exchange item
A concept that defines a type of matter, energy, or data that can flow between two structural objects
within a system; for example, between two part properties that capture the subsystems of the
system in an ibd. An exchange item can be captured as a block or a signal and then assigned as an
item flow to the connector. In that case, the connector is decorated with a filled-in triangle.
The process of reviewing as many components, assemblies, and subsystems as possible to identify
potential failure modes in a system and their causes and effects.
Flow property
A property of an interface block. It can have a direction and a type. The direction of the flow property
specifies whether the property represents an input or an output of the structural object within the
model.
Fork/Join
The fork node marks the start of concurrent flows in an activity. It is represented as a line segment
(either horizontal or vertical), and must have a single incoming flow and two or more outgoing flows.
The join node marks the end of concurrent flows in an activity. It is represented as a line segment
(either horizontal or vertical), and must have two or more incoming flows and a single outgoing flow.
Function
A task performed by a system, or a certain part of it, to transform inputs to outputs. A single function
can be captured as an activity in the model.
Functional block
A concept that is used to define a structural object responsible for performing one or more functions
of the system. Functional blocks are identified by performing the functional decomposition of
the system. Functional blocks serve as inputs for defining the structure of the system of interest.
In MagicGrid, they are called conceptual subsystems.
A set of steps to break down the overall function of a system into its smaller parts, in order to
identify conceptual subsystems (also referred as functional blocks in other methodologies).
A type of user interface that allows the use of icons or other visual indicators to interact with
electronic devices, rather than using only text via the command line.
The core of a solution domain model. Based on the results of the problem domain analysis, it defines
the logical subsystems of the system of interest (as a single-level hierarchy). The purpose of the LSA
model is to identify work packages, one for each subsystem, and appoint them to separate
engineering teams.
A solution domain model that contains the logical architecture of a single logical subsystem and the
high-level design of its components, as well as even more precise units.
Interface
A hardware or software component that connects two or more structural objects of the system or the
system and the objects from its environment, for the purpose of passing matter, energy, or data from
one to the other.
Interface block
A SysML element of definition that can contain a set of flow properties which define the inputs and
outputs of some structural object captured in the model as a block; for example, a system, a
subsystem, or a component. The notation of the interface block is the same as for the block, but with
the «interfaceBlock» stereotype before the name of the element.
A type of structural SysML diagram that can be used to capture the internal structure of a block in
terms of properties and connectors between these properties. Block definition diagrams can be used
to specify the system context and the interactions within the system.
A characteristic of the SoI in numerical format, MoE is a traditional term widely used in systems
engineering, and describes how well a system carries out a task within a specific context.
Model Browser
An element of the modeling tool GUI which represents the contents of the model repository. It is by
default located at the left of the main window of the modeling tool.
A mathematical and visual method of addressing problems associated with designing complex
control, signal processing, and communication systems.
Modeling tool
- Magic Cyber Systems Engineer / Cameo Systems Modeler along with the Cameo DataHub plugin
installed
- Magic System of Systems Architect / Cameo Enterprise Architecture along with the Cameo DataHub
plugin installed
- Magic Software Architect / MagicDraw with the SysML and Cameo DataHub plugins
Object flow
A type of SysML relationship between a pair of actions. Object flows enable you to express what
matter, energy, or data flows through an activity from one action to another when the activity
executes. Object flow is represented as a solid line with an open arrowhead.
Package
A kind of SysML element that can contain other elements. Packages can be used to organize the
elements into logically cohesive groups.
Parametric diagram
A special type of ibd that displays the internal structure of a block, focusing on bindings between the
value properties of that block and the constraint parameters of the applied constraint block.
Parametric diagrams can be used to calculate the values of system parameters (by utilizing the
simulation capabilities of the modeling tool).
Part property
A usage of a block in the context of another block; in other words, a property of a block typed by
another block defined somewhere in your model. It can be represented as a string in the parts
compartment of that block in a bdd, or as a rectangle in an ibd. Using part properties enables you to
specify the internal structure of the system captured in the model as a block. A simplified ibd
(without proxy ports) can be used to specify the interactions within a system context; in that case the
system context is captured as a block, with a part property typed by the block that captures the
system of interest.
Presentation artifact
A visual representation of some fragment or aspect of the system model. It can be a diagram, matrix,
map, or table. Presentation artifacts work as data inputs to the model or data editors.
Proxy port
A type of property of the block, typed by an interface block defined somewhere in your model.
It represents the point at the boundary of the structural object represented by that block, through
which external entities can interact with that structural object. In other words, it is a usage of an
interface block in the context of another block. A proxy port is always represented as a small
rectangle on the shape of the block or part property, usually decorated with an arrow to indicate
Requirement
A SysML element that can capture a text-based statement that translates or expresses a need. It can
be used to capture stakeholder needs, or to specify the system requirements and detailed physical
requirements in the model.
Reliability
Ability of a functional unit to perform a required function under given conditions for a given time
interval (ISO/IEC 2382:2015 Information Technology).
Safety
Sequence diagram
A type of behavioral SysML diagram that can be used to describe how the parts of a block interact
with one another via operation calls and asynchronous signals.
Signal
A piece of the modeling tool GUI. It appears when a symbol of the element is selected on the diagram
pane.
Stakeholder
An individual or organization having a right, share, claim, or interest in a system or in its possession
of characteristics that meet their needs and expectations.
Stakeholder needs
Information gathered from various stakeholders of the system of interest. This information includes
primary user needs, system-related government regulations, policies, procedures, and internal
guidelines, among others. A single stakeholder need can be captured as a requirement in the model.
State
An element that captures a state of the system, in which it can exist during the operation. A state is
represented as a round-cornered rectangle with the name displayed as a string inside that rectangle.
A type of behavioral SysML diagram that can be used to specify how a structure within a system
changes state in response to event occurrences over time. It can be used to specify the behavior of
the system or its parts.
Subsystem
A secondary or subordinate system within a larger system. A subsystem can be captured as a block in
the model.
System context
A concept that determines an external view of the system. It must introduce elements that do not
belong to the system, but do interact with it. Besides the system itself (considered to be a black box),
the collection of elements in the particular system context can include external systems and users
(humans, organizations) that interact with the SoI in that context. A single system context can be
captured as a block in the model.
System
A combination of interacting elements that are organized into a complex whole for one or more
common purposes.
A more abstract, conceptualization-oriented, global architecture, focused to achieve the mission and
operational concept of the SoI, in comparison to system design. It focuses on high-level structure in
systems and system elements.
The system whose life cycle is under consideration. The system that is being analyzed first from the
black- and then from the white-box perspective in order to produce the system requirements
specification.
A SoI whose system elements are systems themselves. Typically, these entail large-scale
interdisciplinary problems with multiple, heterogeneous, distributed systems.
Interdisciplinary tasks that are required throughout a system’s life cycle to transform stakeholder
needs, requirements, and constraints into a system solution.
System requirements
System parameter
A situational decision that involves diminishing or losing one quality, quantity, or property of a set or
design in return for gains in other aspects. In simple terms, a trade-off is where one thing increases
and another must decrease.
Transition
A type of SysML relationship that represents a change from one state to another. It can be triggered
by an event concurrency.
Defines ways of representing an enterprise architecture that enables stakeholders to focus on specific
areas of interest in the enterprise while retaining sight of the big picture. UAF meets the specific
business, operational and systems of systems integration needs of commercial and industrial
enterprises as well as the U.S. Department of Defense (DoD), the UK Ministry of Defence (MOD), the
North Atlantic Treaty Organization (NATO) and other defense organizations.
Use case
A type of SysML element that can be used to capture what capabilities people expect from the
system and what they want to achieve by using it within the particular system context. The notation
for the use case is an ellipse with the name (usually a verb phrase) inside that ellipse.
A type of behavioral SysML diagram that can be used to define a set of use cases performed within a
particular system context; it represents the black-box view of the system of interest. It also displays
and can be used for creating associations between the use cases and the participants of the system
context, to specify who/what is responsible for invoking or participating in what use case.
Value property
A property of a block which can represent a quantity, a Boolean, or a string. It is displayed as a string
in the values compartment of the block, and can be used to capture measurements of effectiveness of
the system of interest (the «moe» stereotype must also be applied).
Aistė is an OMG® Certified Systems Modeling Professional (OCSMP). Currently she holds the position
of industry business consultant for cyber systems engineering at Dassault Systèmes, CATIA brand.
Aistė takes responsibility for educating Dassault Systèmes clients on the three pillars of MBSE: language
(SysML), method (MagicGrid), and tool (CATIA Magic software and integrations). While working with
clients, such as Renault-Nissan, Leica Geosystems, Bombardier Transportation, and Kongsberg Defence &
Aerospace, she provides trainings, gives tool demonstrations, and participates in providing custom
solutions. Aistė also works on training material and writes papers (alone and in collaboration with her
colleagues) to spread the MBSE culture in the systems engineering community. She is a speaker at
multiple MBSE conferences and other public events.
Aistė holds a master’s degree in Information Systems Engineering from Kaunas University of Technology
(Lithuania).
Aurelijus Morkevičius
Aurelijus is an OMG® Certified UML, Systems Modeling, and BPM Professional. Currently he is a senior
manager of industry business consultants for cyber systems engineering at Dassault Systèmes, CATIA
brand.
He has expertise with enterprise, mission, model-based systems and software engineering (mostly based
on UAF, SysML, and UML accordingly) and defense architectures (DoDAF, MODAF, NAF). Aurelijus is a co-
chairman and the leading architect for the current OMG UAF (previously known as UPDM) standard
development group. He represents the CATIA brand at INCOSE and NATO.
Aurelijus holds a PhD in Informatics Engineering from Kaunas University and Technology since 2013. He
currently teaches an Enterprise Architecture course at the same university. Aurelijus is also an author of
multiple articles, and a speaker at multiple conferences.