This document provides instructions for using a relay module timing circuit. It can be set to different operating modes with adjustable on, off, and cycle times from 0.1 seconds to 999 minutes. The module has multiple functions and parameters that are described in detail in the instructions. It is powered by 6-30V and has outputs that can control DC or AC devices.

Uploaded by

Naumaan Akkram
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
230 views6 pages

Relay Module, Delay Off, Off, Trigger Delay, Cycle Timing Circuit Switching

This document provides instructions for using a relay module timing circuit. It can be set to different operating modes with adjustable on, off, and cycle times from 0.1 seconds to 999 minutes. The module has multiple functions and parameters that are described in detail in the instructions. It is powered by 6-30V and has outputs that can control DC or AC devices.

Uploaded by

Naumaan Akkram
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

‫ﻧ‬

Relay module, delay off, off, trigger delay, cycle timing circuit switching

‫ﯿ‬
‫ﯿ‬‫ﻮﮐ‬
‫ﺖ‬

m
.co
op
sh
te
ki
ew
.n
w
w
w
w
w
w
.n
ew
ki
te ‫ﺖ‬
sh ‫ﯿ‬
op ‫ﻮﮐ‬
.co ‫ﯿ‬‫ﻧ‬
m
w
w
w
.n
ew
ki
te ‫ﺖ‬
sh ‫ﯿ‬
op ‫ﻮﮐ‬
.co ‫ﯿ‬‫ﻧ‬
m
‫ﻧ‬
0.1 seconds (min) to 999 minutes (max) continuously adjustable.

‫ﯿ‬
This product is easy to use, many functions, but all buyers need to carefully

‫ﻮﮐ‬
read the instructions, very useful product.
Highlights:
1. Wide voltage power supply (6 ~ 30V), supports microUSB 5.0V power

‫ﯿ‬
supply, easy to use;

‫ﺖ‬
2. The interface is clear and simple, powerful, easy to understand, meet

m
almost all your needs;
3. The emergency stop function (“STOP” key);With reverse polarity

.co
protection, reverse polarity will not burn the product.
4. Increase the sleep mode, if this mode is enabled, without any operation
within 5 minutes, then automatically turn off the monitor, any key wake-up;
5. You can set a different OP, CL, LOP parameters, which are independent of

op
each other, and are automatically saved;
6. After the module is powered down, all parameter settings are not lost.

Operating mode:

"OP" time, as follows:


sh
P1: trigger signal, the relay is on "OP" time, and then disconnect; in the

P1.1: signal is triggered again, invalid


te
P1.2: signal is triggered again, the clock is reset
P1.3: Signal trigger again, relay off, stop the clock;
P-2: trigger signal, the relay off "CL" of time, the relay on "OP" time, and
ki

then disconnect relay;


P3.1: trigger signal, the relay is turned on after the "OP" time, the relay off
"CL" time, then the operation cycle, if the trigger signal period, the relay off,
ew

stop the clock; the number of cycles ( "LOP ") can be set.
P3.2: without triggering signal, the relay is on "OP" time, the relay off "CL"
time, and has been cycling; frequency ( "LOP") cycle can be set;
P-4: signal holding function. If there is a trigger signal timing is cleared, the
.n

relay remains on; when the signal disappears, after the timing "OP" time,
the relay is; if another signal during timing, timing is cleared;
w

Product parameters:
1: Operating voltage: 6--30V, support microUSB 5.0V power supply
2: Trigger Source: Active-high (3.0V-24V), have optocoupler isolation, can
w

improve the system's anti-jamming capability (customers can also shorting


common ground).
w

3: Output capability: You can control the DC 30VDC 5A or 220VAC 5A


device.
4: Quiescent Current: 20mA; Operating Current: 50mA
‫ﻧ‬
5: Life: more than 10 million times; Working temperature: -40-85 °;

‫ﯿ‬
Size: 6.2*3.8*1.7cm.

‫ﻮﮐ‬
6: With optocoupler isolation, enhanced anti-jamming capability, industrial
grade board.
Special Note: The relay outputs are passive contact, just a switch.

‫ﯿ‬
Timing range

‫ﺖ‬
0.1 seconds (min) to 999 minutes (max) continuously adjustable

m
How to choose the time range?
After setting the mode selection screen parameter value by a short press

.co
"STOP" button to select the time range;
XXX. decimal point in the unit place, time range: 1 second to 999 seconds.
XX. X decimal point in decade place, Timing range: 0.1 seconds to 99.9
seconds

op
X. X. X. decimal full brightness, Timing range: 1 minute to 999 minutes.
For example, you want to set "OP" is 3.2 seconds, then move the decimal
point to decade place, the digital display 03.2
Parameter description: "OP" - conduction time, "CL" - off time, "LOP" - the

sh
number of cycles (1-999 times, "---" represents infinite loop).
These parameters are independent of each other, but is shared by each
mode. For example, in P1.1 mode, set the on-time "OP" is 5 seconds, if you
te
switch to P1.2 mode, it's "OP" will be 5 seconds too.
In the main interface (display 000), short press "SET" button will display
"OP" ( "CL", "LOP") and the corresponding time XXX;
ki

Some parameters only mode "OP" (such as the mode P1.1, P1.2, P1.3),
short press the "SET" key to display only the “OP” and the corresponding
time;
ew

Some models have parameters "OP", "CL", "LOP" (such as the mode P3.1,
P3.2), short press "SET" button will display "OP" and the corresponding
time, “CL” and the corresponding time, “LOP” and the corresponding
number of times;
.n

In the main interface by short press "SET" key to see information about the
parameters of the current mode, very convenient!
w

How to set parameters?


1. First, read the instructions to determine the required operating mode.
2. The module is powered up, the display at the current work mode (P1.1
w

default mode), then enter the main interface; press "SET" button for 2
seconds after release to enter mode selection interface; a short time by
w

pressing "UP", "DOWN" key to select the mode (P1.1 ~ P-4).


3. Select the mode (such as P3.2), short press the "SET" button, then the
parameter to be set flashes ( "OP" on-time, "CL" off time, "LOP" cycles ( "---
‫ﻧ‬
" represents infinite loop)), by "UP", "DOWN" keys to adjust the parameter

‫ﯿ‬
value, support long press (rapid increase or decrease) and short press

‫ﻮﮐ‬
(increase or decrease one unit); then short press the "STOP" key to select
the decimal point position, select the time range (0.1 seconds to 999
minutes); short press the "SET" button to set the next parameters of the

‫ﯿ‬
current mode of procedure is as above.

‫ﺖ‬
4. After the parameters are set, long press "SET" button for 2 seconds then

m
release, the name of the current mode will flash once, and then return to
the main screen, set the parameters of success!

.co
The main interface: In the relay does not work status display "000" (no
decimal point), with a decimal point under relay state.
Mode selection screen: Long press the "SET" key to enter, after setting is
completed, long press the "SET" key to exit back to the main screen.

op
"STOP" button extensions:
Relays enable mode:
1. ON: Relay allows conduction in the "OP" on-time;
2. OFF: relay prohibit conduction is always closed;

sh
In the main interface, short press the "STOP" button to switch between ON
and OFF, the current in which the state will flash, and then return to the
main screen. (This feature is an emergency stop function, click off the relay)
te
Sleep mode:
1. "C-P" Sleep mode: five minutes without any operation, the digital display
automatically turns off, the program running as usual;
ki

2. "O-d" normal mode: digital display always open;


Press the "STOP" button for two seconds and then release to switch "C-P"
and "O-d" state, in which the current state of flashes and then return to the
ew

main screen.
.n