This document provides design calculations for lean amine charge pumps in a piping system. It includes operating conditions, suction and discharge conditions, pressure drop calculations, and net positive suction head (NPSH) calculations. The maximum capacity required is 213 gallons per minute at a differential pressure of 973.92 psi, requiring a brake horsepower of 201.7 HP. The maximum shutoff pressure is calculated to be 1270.651 psig. NPSH available is 257.48 feet and NPSH required will be determined based on startup condition requirements.

Uploaded by

Vlanic Studio
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
679 views1 page

Pump NPSH Calculation-0801

This document provides design calculations for lean amine charge pumps in a piping system. It includes operating conditions, suction and discharge conditions, pressure drop calculations, and net positive suction head (NPSH) calculations. The maximum capacity required is 213 gallons per minute at a differential pressure of 973.92 psi, requiring a brake horsepower of 201.7 HP. The maximum shutoff pressure is calculated to be 1270.651 psig. NPSH available is 257.48 feet and NPSH required will be determined based on startup condition requirements.

Uploaded by

Vlanic Studio
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 1

PIPING PRESSURE DROP AND Sheet No. REV.

0
PT. TRIPATRA
ENGINEERS & CONSTRUCTORS PUMP DESIGN CALCULATION SHEET 1/1
DATE 11-Dec-23 JOB No. 9383
REV. DATE DESCRIPTION BY CHK'D APP'D
AMERADA HESS INDONESIA LTD 0 11-Dec-23 RE-ISSUED FOR BID PACKAGE CAN EPM PPS
UJUNG PANGKAH DEVELOPMENT
PROJECT
TAG NO : P-1-0801 A/B
SERVICE : Lean Amine Charge Pumps
SYSTEM SKETCH : Lean Amine to Amine Contactor

4" 6
5
4
10 .3 m
3
2
1

4"

L ea n A mine c oo le r
L ea n amin e A mine c on tac to r
( H- 1 - 08 04 )
c ha r ge p u mp ( V - 1 - 08 01 )
( P- 1 - 08 01 A /B )

OPERATING CONDITIONS DISCHARGE CONDITIONS


1. Fluid Name : amine 1. Line Size (inchi) : 4
2. Temp. Norm (oF) : 113.00 2. ID (inchi) : 4
3. Sp.Gr. Norm. : 1.04 3. Length (Note 1) (ft) : 77.47
4. Vap.Press. Max. (psia) : 0.95 4. Press.Loss (psi) :
5. Viscosity Norm. (cP) : 3.51 a. Line 0.00
6. Capacity Maximum (GPM) : 203 b. Ventury 10.00
7. Capacity Overdesign (%) : 5 c. Exchangers 0.00
8. Capacity Design (GPM) : 213 d. Miscel. (Fitting+Elbows), (note 3) 7.54
e. Sub total (a-d) 17.54
SUCTION CONDITIONS
1. Line Size (inchi) : 4 5. Control Valve (psi) : 14.94
2. ID (inchi) : 4 6. Max.Desti.Press (psig) : 1029.00
3. Length (ft) : 98 7. Elevation (ft) : 32.00
4. Min. Drum Press. (psig) : 101.5 (psi) : 14.38
Max. Drum Press. (psig) : 101.5 8. Disch.Press (psig) : 1075.87 (calc'd)
5. Min. Static Head (ft) : 1 9. Velocity of Fluid (fps) : 5.43
(psi) : 0.449
Max. Static Head (ft) : 1 BRAKE HORSEPOWER (**)
(psi) : 0.45 Eff. = 0.6
6. Line Loss (psi) : 0.00 BHP = 201.7 HP
7. Strainer Loss (psi) : 0 HYDRAULIC POWER = 121 HP
8. Other Loss (psi) : 0.00
9. Suc.Press. Minimum (psig) : 101.95 MAX. SHUT OFF PRESSURE (**)
Suc.Press. Maximum (psi) : 101.9 1. Max. Suc. Drum P (psig) : 101.50
10. Velocity of Fluid (fps) : 0.5 2. Max. Liq Static P (psig) : 0.45
3. Design Suc. P (psig) : 101.95
DIFFERENTIAL PRESSURE 4. Shut off Press =
1. Disch.Pressure (psig) : 1075.87
2. Suc. Pressure (psig) : 101.95 Des.Suc.P 101.95 + 1.2 x Diff.P 973.92
3. Special Margin (psi) : 0.00
4. Diff. Pressure (psi) : 973.92 = 1270.651 (psig)
5. Head(*) (ft) : 2167.35
(*) : to be checked by controlling case (min. sp.gr.) (**) : as guide only

NET POSITIVE SUCTION HEAD


1. Suc. Pressure (psia) : 116.65 Notes :
2. Vap Pressure (psia) : 0.95 1. For pressure drop calculation, this length x 1.5 for safety factor A
3. Net (psi) : 115.70 2. Based on Start up condition requirement
4. NPSH Avail.(*) (ft) : 257.48
5. NPSH Req.(*) max (ft) : (Note 2)
(*) to be checked by controlling case (Max. vap.press.)

2512/ANG/711838994.xls/811x.P.901 A-C 1 of 1