PS-103 Manual en
PS-103 Manual en
Technical Documentation
(103-3-30032011)
St. Petersburg
2015
Unicont SPb Ltd Technical Documentation PS-103
Table of Contents
Page 2
Unicont SPb Ltd Technical Documentation PS-103
1. General information
Power supply unit PS-103-7A (hereinafter referred to as PSU) is intended for supply various
ship and industrial equipment, as well as devices requiring continuous power supply with the
unstabilized voltage 24 V DC.
2. Delivery Set
3. Performance specification
Electrical Specifications:
Supply Voltage: ~110/220 V, 50/60 Hz
Output Voltage: 24V DC
Nominal Load Current: 8A
Nominal Power: 192 W
General Specifications:
Overall Dimensions: 280 х 168 х 100 mm
Operating Temperature: -20.. +55 C°
Storage Temperature: -60.. +70 C°
Weight: 5 kg
Protection Class: IP 22
PSU has metal case with fastening to be installed on the vertical bulkhead. On the case side
there is a switch with supply voltage indication when switched on.
PSU is powered from AC mains ~110/220V, 50Hz and produces DC voltage 24V. In the
device design the provision is made for three output terminals for load connection.
Page 3
Unicont SPb Ltd Technical Documentation PS-103
Electric circuit for PSU includes stepdown transformer, electronic rectifier, and circuits of
automatic switching to emergency power supply.
Power supply is provided for terminal group “BATT 24 VDC” from the backup power
supplies (accumulator batteries) to ensure fault-free operation of equipment connected to PSU.
PSU is switched to backup power supply automatically in case of failure or main power off.
In case of principal input voltage failure alarm is activated in the form of “dry” relay contacts
breaking. If external alarm device is connected with PSU terminals “Alarm”, which operating
principle is based on “dry” relay contacts closing-breaking, then PSU operation from the backup
power supply will be accompanied by alarm of external alarm devices.
Page 4
Unicont SPb Ltd Technical Documentation PS-103
a b
Figure 2. Adjustment of Power Supply Voltage 110V (Figure а), 220V (Figure b).
Page 5
Unicont SPb Ltd Technical Documentation PS-103
Page 6
Unicont SPb Ltd Technical Documentation PS-103
Op
ALARM
Alarm Unit
Com
(AU-106)
Cl
220 VAC OUT 24VDC OUT 24VDC OUT 24VDC BATT 24VDC
L N + - + - + - + -
Safety Precautions:
Prevent device getting into the water and water intrusion into the device.
Not use organic solvents while device surface cleaning to avoid damage of specified
marks.
Prohibited:
Subject the device to shocks and connected cable tension;
Connect PSU to networks with specifications not stated in this documentation;
Use failed device.
Install PSU at the distance less than 1 m from the magnetic compass.
6. Service
3. The rest maintenance procedures consists of meeting operation, storage and transportation
rules. Maintenance shall be performed at least annually.
The device shall be stored in heated space at air temperature of +5 ºС to +35 ºС (maximum
values of -60 ºС to +70 ºС), at relative humidity of air not exceeding 95 % at temperature of +25 °C
and content of dust, oil, moisture and aggressive admixtures in the air not exceeding the norms
envisaged by GOST 12.1.005-88 for the working zone of production areas.
Page 7
Unicont SPb Ltd Technical Documentation PS-103
The device shall be transported in transport container of the manufacturer in closed transport.
Means of transport:
automobile and railway closed transport (covered wagons, universal containers)
by air (in pressurized and heated bays of airplane)
by sea (in dry service spaces).
The device shall be transported in accordance with the transport regulations in force for the
particular transport.
During handling operations and transportations strictly observe the requirements of handling
marks on boxes and do not allow bumps and impacts which can affect preservation and serviceability
of the device.
After storage in stores or transportation at temperature below +10 ºС the devices shall be
unpacked only in heated spaces after keeping them unpacked in under normal climatic conditions
for12 hours.
Page 8
Unicont SPb Ltd Technical Documentation PS-103
8. Warranty
The manufacturer guarantees the unit PS-103 complies with this manual provided that the
operation, transportation and storage conditions are adhered to during the warranty period.
The unit’s warranty period expires 24 months from the date of its shipping from the
manufacturer’s storehouse.
Within the warranty period, the owner is entitled for a free repair, or a replacement of a
separate part, provided that the malfunction occurred through the manufacturer’s fault.
Warranty repair is provided if the unit is submitted with the manufacturer’s label and a
legible serial number available on it, as well as this operating manual.
The manufacturer is not responsible and cannot guarantee the unit’s operation:
1. After the warranty period is over;
2. In case of the failure to observe the unit’s operation, transportation, storage and
installation rules and conditions;
3. If the unit is in an unmarketable condition, or has a damaged body, and other causes
beyond the manufacturer’s control;
4. If self-made electrical devices were used.
5. If there was an attempt to repair the unit by a person who is not an authorized
representative of the manufacturer.
If the owner loses this operating manual or the manufacturer’s label with a serial number, the
manufacturer shall not provide their copies, and the owner shall be divested of the right for a free
repair during the warranty period.
Upon the warranty expiry, the manufacturer shall facilitate the repair of the unit at the
owner’s expense.
Note: in case of warranty repair, the unit’s disassembling from the installation site and its
delivery to the manufacturer’s service center are done at the owner’s expense.
Page 9
Unicont SPb Ltd Technical Documentation PS-103
9. DATE OF PACKING
was manufactured and accepted in accordance with the regulatory requirements of the
state standards and applicable technical documentation, and is suitable for operation.
Stamp
here signature clarification of signature
Page 10