The document summarizes the features and specifications of the AutroSafe Controller - BC-320 fire alarm panel. It can accommodate up to 12 modules, including a maximum of 6 loop driver modules. It supports surface, flush, or rack mounting. Key features include EN-54 compliance, environmental hardening, and indicators for power and faults. The panel interfaces detector loops, alarms, controls and inputs. It supports a maximum of 32 panels per LON ring and 512 devices total.

Uploaded by

Irlan Leite
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
28 views2 pages

bc320 Ce

The document summarizes the features and specifications of the AutroSafe Controller - BC-320 fire alarm panel. It can accommodate up to 12 modules, including a maximum of 6 loop driver modules. It supports surface, flush, or rack mounting. Key features include EN-54 compliance, environmental hardening, and indicators for power and faults. The panel interfaces detector loops, alarms, controls and inputs. It supports a maximum of 32 panels per LON ring and 512 devices total.

Uploaded by

Irlan Leite
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

AutroSafe Controller - BC-320

Features
• Accommodates up to a maximum of 12 modules,
of which maximum six can be loop-driver modules
• Addressable electronic sounders can be con-
nected directly on the detector loop
• Capable of surface or flush mounting and for rack
mounting in standard 19’’ cabinets
• Designed to meet EN-54 requirements, and con-
forms to CE standards
• Complies to environmental conditions of IEC-721-
3-3 class 3k5
• Indicators for fault and power

Applications
The Controller, BC-320, serves as a connection unit
for the detector loop, alarm sounders, controls and
inputs.
Indicators
• Power (green)
The panel can accommodate up to a maximum of
12 modules. The system offers a Loop-Driver Mod- • Fault (yellow)
ule for detector loops and several types of I/O mod-
ules for monitored outputs, open-collector outputs, Optional I/O Modules
galvanic isolated inputs and monitored inputs. There • Loop-Driver Module (BSD-310/311). For connec-
can be a maximum of six loop-driver modules in tion of detector loops. One detector loop can be
each panel. All modules are easily plugged onto connected to each module. A maximum of 127
each other on a standard mounting rail inside the loop units (detectors, manual call-points, I/O-units
unit. and/or electronic sounders) can be connected to
each detector loop
The Controller communicates with other system • Output Module (BSB-310), with 4 monitored out-
units on the local operating network, AUTROLON. puts. For connection to fire alarm devices (FAD),
such as sounders etc., and fire-protection equip-
It has a 230V AC/3A power module for operation ment (FPE) such as fire doors, ventilation control-
and battery charging, and can accommodate a lers or fire extinguishers. Also suitable for connec-
24V/12 Ah battery. tion to fire alarm routing equipment (FARE), such
as fire brigade equipment, and for connection to
Capacity fault outputs (FWRE)
• There can be a maximum of 32 panels in a LON- • Output Module (BSJ-310), with eight open collector
ring (EN-54). A demand for more than 32 panels non-monitored outputs. For connection of external
requires several LON-rings LED-indication panel
• Each unit can be equipped with a maximum of 12 • Input Module (BSE-310) with four monitored inputs
modules, of which maximum six can be loop-driver
modules • Input Module (BSE-320), with eight non-monitored
inputs (galvanically isolated)
• 127 detectors, manual call-points and I/O units can
be connected to each detector loop. Of these,
maximum 100 can be detectors/manual call-points
• A maximum of 512 detectors and manual call-
points can be connected to each controller

116-P-BC320/CE-Rev.F, 2005-05-31 Protecting life, environment and property...


Controller, BC-320

Dimensions
Technical Specifications
Dimensions (mm) 350x350x194
Cut-Out Dimensions 320x330x140
(mm)
Weight (Without I/O modules and
batteries) 8,5 kg
Materials Steel cabinet, ABS/PC-moulded
front
Mounting Surface or flush mounting
Protection class IEC-529 / IP30
Operating Temperature 0oC to +55oC
Storage Temperature -40oC to +70oC
Power supply 230VAC
(160-265VAC)
Frequency: 47-63Hz or 24V DC
Current consumption 250 mA at 27V DC
(when no I/O modules are
connected)
Capacity – Loop-Driver Maximum 12 modules
Modules and I/O (a combination of BSD-310, BSB-
Modules 310, BSE-310/320 and BSJ-310)
Capacity – Loop-Driver Maximum six BSD-310/ 311. The
Module maximum number of detectors
and manual call-points that can
be connected to these six
modules is 512 (refer to EN-54).
Maximum 127 detectors/manual
call-points/electronic sounders/
I/O units on each detector loop
Batteries 2 x 12V = 24V not included
Detector connection By use of BSD-310/BSD-311
Inputs By use of BSE-310 and BSE-320
Outputs By use of BSB-310 and BSJ-310
Communication AutroLON
AutroCom/Ethernet System Overview
AutroCom/Serial Port

Controller Controller
Order Numbers Fire
A
AA
ALLLLA
AA
AR
RR
RM
MM
M A
AA
ALLLLA
AA
AR
RR
RM
MM
M

Alarm Fire ext.. acktivated


S ilence buzzer
Fire ext.. acktivated
Silence buzzer

Order number Description


Fire vent. activ. Fire vent. activ.
Mor eA lar ms Silence sounders More Alarms Silence sounders
Fire Brig. recvd. Fire Br ig. recvd.

Control
Power R eset Power R eset

Prewarning Prewarning
1 2 3 P ower 1 2 3 P ower
E arly warning E arlywarning
Fault 4 5 6 Fault 4 5 6
6

System fault System fault

Panel
7 8 9 Fault 7 8 9 Fault
Function disabled Function disabled
Test C 0 Test C 0

2
BC-320/GB200 Without I/O modules and battery
? ?

Self Verify Sel f Verify


Verif y Self Verify Sel f Verify

(maximum seven I/O modules) Aut ro nica


Operator Panel
Au tronica

I/O
BC-320/GB101 One piece BSD-310, one piece K N U S G LA S SE T
T RYKK H ER
BR E AK
PRESS HER E
G LA S S
K N U S G LA S SE T
T RYKK HER
B R E AK
PRESS HER E
G LA S S

BSB-310, with space for battery


K N U S G LA S SE T
Aut ro nica
T RYKK HER PRESS HER E
B R E AK G LA S S

Au tronica

BC-320/GB202 Two pieces BSD-310, one piece I/O


K NU S G LA SS ET
T RYK K HER PRES S H ERE
I/O I/O
I/O
B R EA K G LA SS

BSB-310, with no space for


battery
BC-320/GB203 Four pieces BSD-310, one piece Repeater
Panel
Information
Panel
BSB-310, with no space for AALLLLA
AA AA
AR
RR
RM
MM
M INFORMASJONSPANEL
Power
A
AA
ALLLLAAR
AA RM
RR M
MM IN FORMASJONSPANEL

battery
Fault

F ire ext. aktivated Fir e ext. aktivated


Silence buzzer Silence buzzer
F ire vent. activ. Fir e vent. activ.

F ire B rig. recvd. More A larms Silence sounders Fir e Brig. recvd. More A lar ms S ilence sounders

P ower Reset Self Verify Power Reset

Options: Controller

BSD-310/311 Loop-Driver Module


BSB-310 Output Module
with four monitored outputs
BSJ-310 Output
Module with eight open collector
outputs
Non-monitored
BSE-310 Input Module
(Four monitored inputs)
BSE-320 Input Module
(Eight non-monitored, galvanically
isolated inputs)
Options: AutroCom/Ethernet or Serial Port
Options: Language

Autronica Fire and Security AS


Fire and Security, Trondheim, Norway. Phone: + 47 73 58 25 00, fax: + 47 73 58 25 01
Oil & Gas, Stavanger, Norway. Phone: + 47 51 84 09 00, fax: + 47 51 84 09 99
Maritime Sales, Spikkestad, Norway. Phone: + 47 31 29 55 00, fax: + 47 31 29 55 01
Visit Autronica Fire and Security’s website: www.autronicafire.com

You might also like