USER GUIDE
MPPT solar charge controller
358-010277-01
Contents
1 ABOUT THIS MANUAL ..................................................................................... 1
1.1 Purpose ................................................................................................. 1
1.2 Scope .................................................................................................... 1
1.3 SAFETY INSTRUCTIONS ........................................................................ 1
2 INTRODUCTION .............................................................................................. 2
2.1 Features................................................................................................. 2
2.2 Product Overview ................................................................................... 2
3. INSTALLATION ............................................................................................... 3
3.1 Unpacking and Inspection ........................................................................ 3
3.2 Preparation ............................................................................................ 3
3.3 Mounting the Unit .................................................................................... 3
3.4 Power Connection ................................................................................... 4
3.5 Grounding and Ground Fault Interruption .................................................. 5
3.6 Remote Temperature Sensor .................................................................... 5
3.7 Battery Voltage Sense ............................................................................. 6
4. OPERATION ................................................................................................... 7
4.1 Power-Up ............................................................................................... 7
4.2 Operation and Display Panel .................................................................... 7
4.3 LCD Display Icons ................................................................................... 8
4.4 LCD setting ............................................................................................. 9-12
4.5 Reference Code ...................................................................................... 13
4.6 Introduction to load mode......................................................................... 13
5. CHARGING LOGIC ......................................................................................... 14
5.1 3-stage Charging .................................................................................... 14
5.2 Equalize Stage ....................................................................................... 15
5.3 Setting Parameter and Default Value ........................................................ 16
6. TROUBLE SHOOTING .................................................................................... 17
7. SPECIFICATIONS ........................................................................................... 18-19
8. MPPT charger controller match to the Inverter ....................................................... 20
8.1 Match the inveter to the MPPT controller ................................................... 20
8.2 Matching MPPT function is prohibited........................................................ 19
8.3 Matching MPPT function successfully enabled ........................................... 21
8.4 Matching MPPT function is prohibited successfully..................................... 21
MPPT solar charge controller MPPT solar charge controller
1. Before using the unit, read all instructions and cautionary markings on the unit, the batteries and all
appropriate sections of this manual. 1
2. Do not disassemble the unit. Take it to a qualified service center when service or repair is required. 2 4
CHARGING
3. To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning.
3
Turning off the unit will not reduce this risk. Make life full of hope
4. CAUTION – Only qualified personnel can install this device with battery. Make life full of hope
Thank you for selecting this solar charge controller. This solar charge controller is anadvanced solar
Make life full of hope
charger with maximum power point tracking. Applying intelligent MPPTalgorithm, it allows solar charge
controller to extract maximum power from solararrays by finding the maximum power point of the array. 6 7 8 9 10
Make life full of hope
The MPPT battery charging process has been optimized for long battery life andimproved system performance.
Self-diagnostics and electronic error protectionsprevent damage when installation errors or system faults
occur. This charger alsofeatures multifunctional LCD with communication ports for remote battery 6 7 8 9
temperature and voltage measurement. 45A / 60A / 80A(12V / 24V / 48V) 8 100A / 120A
(12V / 24V / 48V)
7 11
6 9 12
B
Overcurrent Protection and Disconnects
CAUTION: Circuit breakers or fuses must be installed in both battery and solarcircuits.
The battery circuit breaker or fuse must be rated to 125% of the maximum current or more. The recommended
3.3 Mounting the Unit breaker/fuse rating for use with the charger is listed in the below table.
50CM
Consider the following points before selecting where to install: Recommended breaker rating:
• This solar charge controller is designed in IP31 for indoor applications only. Minimum battery circuit breaker/fuse rating
• Do not mount the unit on flammable construction materials. 1.25 x 20Amps = 25.0 Amps 1.25 x 30Amps = 37.5 Amps
• Mount on a solid surface 1.25 x 45Amps = 56.3 Amps 1.25 x 60Amps = 75.0 Amps
• Install this charger at eye level in order to allow the LCD display 1.25 x 80Amps = 100.0 Amps 1.25 x 100Amps = 125 Amps
20CM 20CM
to be read at all times. 1.25*120Amps = 150Amps
Make life full
of hope
• For proper air circulation to dissipate heat, allow a A disconnect is required for the battery and solar circuits to provide a means for removing power from
clearance of approx. 20 cm to the side and approx. 50 cm the charger. Double pole switches or breakers are convenient for disconnecting both solar and battery
above and below the unit. conductors simultaneously.
• The ambient temperature should be between 0°C and 55°C
Connect the Power Wires
50CM
03 04
MPPT solar charge controller MPPT solar charge controller
Connect terminals by following below steps (Refer to diagram above): The RTS cable may be pulled through conduit along with the power wires. Tighten the connector screws
1. Make sure that the system input and output disconnect switches are both turnedoff before connecting with 5 in-lb (0.56 Nm) torque.
power wires to the charger. There are no disconnecting switches inside the charger. NOTE: The RTS is optional package. Please check local dealer for the details.
2. Make 4 power wires first. Remove insulation sleeve 10.5mm and the conductor should be plated Tin.
Refer to the chart below.
10.5mm
Tin Plating
3. Pull all wires into the wiring box. The Remote Temperature Sensor and Battery Sense wires can be
inside the conduit with the power conductors. It is easier to pull RTS and Sense wires before the power
cables.
CAUTION: The controller will not activate temperature compensate charging functionif the RTS is not used.
WARNING: Risk of Damage CAUTION: Equipment Damage
Be sure that the battery connection is made with correct polarity. Turn on the battery breaker/disconnect Never place the temperature sensor inside a battery cell. Both the RTS and the battery will be damaged.
and measure the voltage on the open battery wires BEFORE connecting to the controller. Disconnect the NOTE: The RTS cable may be shortened if the full length is not needed.
battery breaker/disconnect before wiring to the controller.
3.7 Battery Voltage Sense
4. Connect positive terminal (+) of battery to the battery positive terminal (+) on the controller. The voltage at the battery connection on the controller may differ slightly from the voltage directly at the battery
5. Connect negative terminal (-) of battery to one of the Common Negative terminals (-) on the controller. bank terminals due to connection and cable resistance. The Battery Voltage Sense connection enables the
controller to measure the battery terminal voltage precisely with small gauge wires that carry very little current,
WARNING: Risk of Damage and thus have no voltage drop. Both battery voltage sense wires are connected to the 2-pole terminal inside
Be sure that solar connection is made with correct polarity. Turn on the solar breaker/disconnect and measure of wiring box (see figure as below).
the voltage on the open wires BEFORE connecting to the controller. Disconnect solar breaker/disconnect
before wiring to the controller. Be careful to connect the battery positive (+) terminal to the voltage sense positive (+) terminal and battery
6. Connect positive wire (+) of solar module to the solar positive terminal (+) on the controller. negative (-) terminal to the voltage sense negative terminal (-). No damage will occur if the polarity is reversed,
7. Connect negative wire (-) of solar module to one of the Common Negative terminals but the controller cannot read a reversed sense voltage.
(-) on the controller.
8. Screw four (4) power terminals tightly with 50 in-lbs torque. (5.65 Nm)
9. Connect the positive conductor of the load module (+) to the positive terminal of the load on the
controller (+).
10. Connect the negative conductor of the load module (-) to the negative terminal of the controller (-).
A battery voltage sense connection is not essential required to operate your controller,but it is recommended
The minimum size of the copper grounding wire is 8 AWG (10 mm2). for best performance. The battery voltage sense will ensurethat the voltage display in LCD is very accurate.
WARNING: Risk of Fire
DO NOT bond system electrical negative to earth ground at the controller. The voltage sense wires should be cut to length as required to connect the battery tothe voltage sense terminal.
The wire size can range from 16 to 24 AWG (1.0 to 0.25mm2). A twisted pair cable is recommended but not
3.6 Remote Temperature Sensor required. Use UL rated 300 Voltconductors. The voltage sense wires may be pulled through conduit with the
powerconductors. Tighten the connector screws with 5 in-lb (0.56 Nm) torque.The maximum length allowed
The included Remote Temperature Sensor (RTS) is recommended for effective temperature compensated
for each battery voltage sense wire is 98 ft (30 m).
charging. Connect the RTS to the 2-pole terminal (see figure as below). The RTS is supplied with 33 ft (10 m)
of 22 AWG (0.34 mm2) cable. There is no polarity, so either wire (+ or -) can be connected to either
screw terminal.
05 06
MPPT solar charge controller MPPT solar charge controller
Button Operation
4. OPERATION
Function Action Description
4.1 Power-Up Power on Press the button until LCD backlight is on.
WARNING: Risk of Damage Backlight on Press shortly
Connecting the solar module to the battery connector will permanently damage the controller. Enter LCD setting mode Press the button for 3 seconds.
• Confirm that the solar and battery polarities are correctly connected to the controller.
Select LCD setting programs or modify
• A battery must be connected to the controller before operating it. The controller will not operate only with Press shortly.
parameter
solar input. Solar input can trigger the controller to start up when the battery is connected without pressing
Confirm selection in setting programs
the button. Press the button for 1.5 seconds.
or return back to previous menu
• Turn on battery disconnect switch first. And press operation button for a while. Then, it will indicate a
successful start-up in LCD display.
4.3 LCD Display Icons
• Turn on solar disconnect switch. If the solar module is in full sunlight, the controller will begin charging.
07 08
MPPT solar charge controller MPPT solar charge controller
Setting Programs:
Program Description Options 14.40V (Default)
If “Use-Defined” is selected in program
Escape
02, this program can be set up. The
00 Exit setting mode setting range is from12.0V to 15.0V.
If “LIb” is selected in program 02,
the setting range is from 12.0V to
15.0V/24.0V to 30.0V/48.0V to 60.0V
20A(Default)
45A(Default)
100A(Default)
120A(Default)
09 10
MPPT solar charge controller MPPT solar charge controller
12V
If “12V” is selected, the unitis 30 days (Default)
considered as 12V batterysystem. The setting range is from 0
05 Battery rated voltage 13 Equalization interval day to 90 days.
24V
If “24V” is selected, the unitis
considered as 24V batterysystem. If equalization function is enabled in
Disable (Default) program 08, this program can be set up.
If “48V” is selected, the unit is If “Enable” is selected in this program,
48V considered as 48V battery system. it’s to activate battery equalization
Note:MPPT 30A,45A(12/24V) can't immediately and LCD main page will
set the Absorption voltage to 48v.
Equalizationactivated shows “ ”. If “Disable” is
150 minutes(Default) The setting range is from 5minutes to 14
immediately
Battery C.V. charging 900 minutes.Increment of each short selected, it will cancel equalization
06 press is 5 minutes. It willjump back to
duration function until next activated
5minutes after900 is achieved. Disable (Default) equalization time arrives based on
The setting range is from0mV to
60.0mV. Incrementof each short press program 13 setting. At this time, “ ”
0mV (Default) is 0.1 mV.The value will jump back to will not be shown in LCD
BTS temperature 0mV after 60.0mV isachieved.For main page.
07 compensation ratio each 12V battery, thederated battery
chargingvoltage is followed the below
formula:(Battery temperature – 25 o C) If “Use-Defined” is selected in program
* BTS ratio. 11.0V (Default) 02, this program can be set up. The
setting range is from10.0V to 12.5V.
Disable (Default) 15 If “LIb” is selected in program 02,
the setting range is from 10.0V to
12.5V/20.0V to 25.0V
11 12
MPPT solar charge controller MPPT solar charge controller
CURRENT
VOLTAGE
05 PV is high loss
BULK
NIGHT ABSORPTION FLOAT NIGHT
CHARGE
06 Battery temperature is too low
Lower than
float voltage
for 30 min.
Float Float Voltage
Voltage FLOAT Cancel
Voltage
FLOAT FLOAT
BULK ABSORPTION BULK ABSORPTION BULK ABSORPTION BULK ABSORPTION
13 14
MPPT solar charge controller MPPT solar charge controller
Absorption Voltage
CURRENT
VOLTAGE
BULK
NIGHT ABSORPTION FLOAT NIGHT
CHARGE
TIME TIME
However, in Equalize stage, when battery equalized time is expired and battery voltagedoesn’t rise to battery
equalization voltage point, the solar charge controller willextend the battery equalized time until battery
voltage achieves battery equalizationvoltage. If battery voltage is still lower than battery equalization voltage
When to Equalize
when batteryequalized timeout setting is over, the solar charge control will stop equalization andtransfer to
In Absorption stage, if the charging current drops lower than the maximumcharging current of battery float stage.
equalization, the controller will start to enter Equalizestage.
Equalize
Charging Time
Equalize Voltage
Absorption Voltage
Float Voltage
BULK ABSORPT. EQUALIZE FLOAT
CURRENT
VOLTAGE
ABSORPTION EQUALIZE
BULK
NIGHT FLOAT NIGHT
CHARGE
TIME TIME
If solar charge controller is working in float stage, but at this time, the settingequalization interval (battery 5.3 Setting Parameter and Default Value
equalization cycle) is arrived, it will transfer toequalize stage. Recommended and default parameter settings are listed below.
Equalize Voltage Unit - Volt Volt Volt En/Disable Minutes Minutes Minutes Days
Float Voltage
EQUALIZE
15 16
MPPT solar charge controller MPPT solar charge controller
Maximum Battery 30Amps 45Amps 45Amps 60 Amps 80 Amps 100Amps 120 Amps
20Amps
1. Restart the charger. Current
01 Over charge current
2. If the problem remains, please contact your installer. Nominal System
12,24VDC(Auto detection) 12V, 24V, 48V DC (Auto detection)
Voltage
1. Keep the charger in the cool environment.
02 Over temperature Maximum Solar
2. If the problem remains, please contact yourinstaller. 95V 145V 195V
Input Voltage
1. Check the battery wire connection. PV Start-up
03 Battery voltage low
2. If the wire connection is ok, please contact yourinstaller. Voltage 15V
too high 2. If the problem remains, please contact yourinstaller. PV Array voltage
Battery Current(Amps)
Battery Current(Amps)
Battery Current(Amps)
& Battery current
1. Check your remote temperature sensor andyour battery ambient
Battery temperature
07 temperature.
too high 2. If the problem remains, please contact yourinstaller.
80 95 130 145 170 195
Array Voltage(Volts) Array Voltage(Volts) Array Voltage(Volts)
No display in LCD screen. 1. Check battery wire connection. For SCCM4524 For SCCM4548 / SCCM6048 / SCCM8048 For SCCM10048 / SCCM12048
Maximum
Battery
Current
Heatsink
Battery Current(Amps)
temperature &
Battery current
65 67.5 70 72.5 75 77.5 80 82.5 85
Heatsink Temperature
(degrees C)
Transient Surge
4500 Watts / port
Protection
17 18
MPPT solar charge controller MPPT solar charge controller
2.Limited the charging current of the inverter. The methods are as follows:
Voltage
a) When the MPPT charging current ≥ inverter setting charging current, the maximum allowable
100% charging current of the inverter equal to 0;
b) When the MPPT charging current < inverter setting charging current, the maximum allowable
Charging Curve charging current of the inverter equal to inverter setting charging current subtract MPPT
50%
charging current;
T0 T1
T1=10*T0,minlmum 10mlns,maximumghrs
Time
8.1 Match the inveter to the MPPT controller:
(Constant Current) (Constant Voltage) (Floating)
1.To enable the inverter to match the MPPT controller, the inverter and MPPT controller should be
switched on first, and the communication lines between them have been connected;
2.Then press the “Down”button of the inverter for more than 2.5 seconds, until the MPPT charger icon
Table 3 Mechanical and Environment flashes. At this time, you can release the button. The icon flashing indicates that the inverter is trying to
communicate with the MPPT. The inverter is releasing. After pressing the button for 10 seconds, the
icon stops flashing. When the communication is successful, it means that the function is successfully
Model SCCM2024-II SCCM3024-II SCCM4524-II SCCM4548-II SCCM6048-II SCCM8048-II SCCM10048-II SCCM12048-II enabled.
Product Size 3.After successfully enabling, the matching MPPT function flag will be saved in the EEPROM. Restarting
(W x H x D,mm) 201x137x65 201x137x65 221x152x73 277x185x100 277x185x100 290x199x103 319x218x118 319x218x118
the inverter does not need to be manually enabled again.
Product 4.After successfully enabling, turning the page on the LCD screen will display MPPT PV voltage, power
Weight (Kg) 1.2 Kg 1.2 Kg 1.8 Kg 3.4 Kg 4.7 Kg 5.9 Kg 6.5 Kg 6.5 Kg and other information.
Ambient
Temperature
Range
0℃ to +55℃ Action Instruction LCD display
Storage Long press “Down”button until the
Temperature - 25℃ to 75℃ INPUT
Humidity 0%-90%RH(No condensing) Match the MPPT flashes, indicating that the inverter is
function enable trying to communicate with MPPT. The
Enclosure IP20(indoor&vented) icon stops flashing after the inverter
loosens the button for 10 seconds.