An Internal Error Has Occurred. (Code - 0x8003001D, Could Not Access File For Write Operation) - When Saving A Change in SmartConsole
An Internal Error Has Occurred. (Code - 0x8003001D, Could Not Access File For Write Operation) - When Saving A Change in SmartConsole
"An internal error has occurred. (Code: 0x8003001D, Could not access file for write operation)" when
saving a change in SmartConsole
Solution ID sk119973
Technical Level
Symptoms
"An internal error has occurred. (Code: 0x8003001D, Could not access file for write operation)" when saving a change in SmartConsole.
Solution
Scenario 1 - Issue with Geo Policy after upgrading the Security Management Server
Additional Symptoms:
The following error message is displayed in SmartConsole after making changes in the object and clicking on OK:
Failed to save object <Name_of_Object>
Server error is: An internal error has occurred. (Code: 0x8003001D, Could not access file for write operation)
Please contact technical support
Expected single result for object with uid XXX-XXX-XXX-XXX-XXX, got: 0"
from class org.springframework.dao.DataIntegrityViolationException
Solution:
CPinfo
$FWDIR/log/cpm.elg*
migrate export
3. Transfer the TAR-ball with the script (add_default_geo_policy.tar) to the Security Management Server (into some directory, e.g., /some_path_to_fix/).
6. Go to the directory, in which you put the TAR-ball with the script.
[Expert@HostName:0]# cd /some_path_to_fix/
10. Close all SmartConsole windows. Verify by running the "cpstat mg" command on Security Management Server.
11. Execute the script to add the 'Default Geo Policy' object:
Note: Change the username and password in the command to your SmartConsole credentials.
Note: You can see the script's output log in the $MDS_FWDIR/log/cpm.elg file.
[Expert@HostName:0]# cpstop
[Expert@HostName:0]# cpstart
Additional Symptoms:
When using Legacy SmartDashboard to modify the IKE encryption settings of an External User Profile, making change and closing the External User Profile win
seconds and then shows:
Solution:
If you choose not to upgrade, Check Point can supply a Hotfix. Contact Check Point Support to get a Hotfix for this issue.
A Support Engineer will make sure the Hotfix is compatible with your environment before providing the Hotfix.
For faster resolution and verification, please collect CPinfo files from the Security Management Server and Security Gateways involved in the case.
Scenario 3 - Permission issue
Additional Symptoms:
The following error message is displayed in SmartConsole after making changes in the object and clicking on OK:
"error has occurred. (Code: 0x8003001D, Could not access file for write operation) Please contact technical support. ""
The current changes to object parameters are invalid and therefore will be discarded.
Unable to change firmware version.
Solution:
To fix the issue, give the required permission to the correct profile.
Applies To:
PMTR-35367 , PRHF-3128,
This sk replaces: sk149852, sk163173