0% found this document useful (0 votes)
57 views10 pages

Carnot Cycle

The document summarizes several thermodynamic cycles including the Carnot, Diesel, Dual, Otto, Ideal Brayton, and Actual Brayton cycles. Each cycle is defined by its efficiency equation, the heat added and rejected, work done, volume displaced, compression/expansion ratios, and other key parameters.

Uploaded by

Sande Nas
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
57 views10 pages

Carnot Cycle

The document summarizes several thermodynamic cycles including the Carnot, Diesel, Dual, Otto, Ideal Brayton, and Actual Brayton cycles. Each cycle is defined by its efficiency equation, the heat added and rejected, work done, volume displaced, compression/expansion ratios, and other key parameters.

Uploaded by

Sande Nas
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 10

CARNOT CYCLE DIESEL CYCLE DUAL CYCLE

Efficiency: Efficiency: Efficiency:


W net
e cycle= W net W net
QA e cycle= e cycle=
QA QA
QR
e cycle=1− QR QR
QA e cycle=1− e cycle=1−
QA Q AT
Heat Added: B C
Q A =T h ∆ S e cycle=1− e cycle=1−
A A
Heat Rejected:
k
k r p r cut −1
r cut −1 C=
B= ( r p−1 ) + r p k ( r cut −1 )
Q R=T l ∆ S k ( r cut −1 )
Heat Added:
Work: Heat Added: Q AT =Q Av +Q Ap
Q A =m c v ( T 3−T 2 )
W net =Q A −Q R Q Av=mc v (T 3−T 2)
W net =∆ T ∆ S Heat Rejected: Q Ap=m c p (T 4−T 3 )

Heat Rejected:
4
Q R=m c v ( T 4 −T 1)
W net =∑ W NF
1 Work: Q R=m c v ( T 5−T 1 )
Mean Effective Pressure: W net =Q A −Q R Work:
W net W net = pmep V D
pm = W net =Q AT −QR
VD
Volume Displaced: W net = pmep V D
Expansion Ratio: V D=V max−V min
V3
r eT = V D=V max−V c
V2 Volume Displaced:
V4 Clearance Volume: V D=V max−V min
r ek = V c =c V d
V3 V D=V max−V c
V max V c =V min
re= Clearance Volume:
V min Cut-Off Volume: V c =c V d
V cut =V 3−V 2
V c =V min
Clearance:
Cut-Off Volume:
Compression Ratio: c=
1 V cut =V 4 −V 3
V4 r c −1
r cT = Clearance:
V1 Compression Ratio:
V1 1 1
r ck = r c =1+ c=
V2 c r c −1
V max V max Compression Ratio:
r= rc=
W net V4 Expansion Ratio:
V D= re=
pm V3 V5
re=
Cut-Off Ratio: V4
V3 Cut-Off Ratio:
OTTO CYCLE r cut =
V2
r cut =
V4
Efficiency: Power: V3
W net P= ṁ ( wnet ) Pressure Ratio:
e cycle= p3
QA r p=
QR p2
e cycle=1−
QA IDEAL BRAYTON
1
e cycle=1−
A CYCLE
k−1
A=r c Efficiency:
Heat Added: e cycle=
W net
Q A =m c v ( T 3−T 2 ) QA
1
Heat Rejected: e cycle=1− k−1
k
ACTUAL BRAYTON
Q R=m c v ( T 4 −T 1) r p

( T 3−T 4 )− ( T 2−T 1 ) CYCLE


Work: e cycle = Heat Added:
T 3−T 2
W net =Q A −Q R '
Q A =m c p (T 3−T 2 )
'

W net = pmep V D
Heat Added:
Q A =m c p (T 3−T 2 ) Heat Rejected:
Volume Displaced: Heat Rejected:
'
Q R=m c p (T 4−T 1)
V D=V max−V min
V D=V max−V c
Q R=m c p (T 4−T 1) Work:
Work: W net =W T −W C
Clearance Volume:
V c =c V d
W net =W T −W C Turbine Work:
V c =V min Turbine Work: '
W T =m c p (T 3−T 4)
'

Clearance: W T =m c p (T 3−T 4) Compressor Work:


1 Compressor Work: '
W C =m c p (T 2−T 1)
c=
r c −1
W C =m c p (T 2−T 1) Turbine Efficiency:
Compression Ratio: Compression Ratio: '
1 WT
r c =1+ V1 eT =
c rc= WT
V2
Compressor Efficiency:
V max Pressure Ratio: WC
rc= e C= '
V min p2 WC
r p=
Power: p1 Pressure Ratio:
P= ṁ ( wnet ) Back Work Ratio: p2
r p=
WC p1
rb =
WT Back Work Ratio:
WC
rb =
WT

BRAYTON w/
REGENERATOR
Efficiency:
BRAYTON w/ e cycle=
W net

REHEATER QA
( T 4−T 5 )− ( T 2−T 1 )
Efficiency: e cycle =
T 4−T 3
W net
e cycle=
Q AT Heat Added:
Q A =m c p (T 4 −T 3)
Heat Added Combustor:
Q AC =m c p (T 3−T 2) Heat Rejected:
Heat Added Reheater: Q R=m c p (T 6−T 1)
Q AR=mc p (T 5−T 4 ) Heat Regenerated (Ideal):
Q REG =m c p ( T 5−T 6 )
Total Heat Added:
Q AT =Q AC +Q AR Heat Regenerated (Actual):
Heat Rejected: '
Q REG=m c p ( T 3−T 2 )
Q R=m c p (T 6−T 1) Work:
Work: W T =m c p ( T 4 −T 5)
W net =W TT −W C W C =m c p ( T 2−T 1)
Turbine Work: W net =W T −W C

W HPT =mc p ( T 3 −T 4 )
Regenerator Effectiveness:
'
Qreg
W LPT =m c p ( T 5−T 6 ) e r=
Qreg
W TT =W HPT +W LPT T 3−T 2
e r=
T 5−T 6∨2
Compressor Work:
W C =m c p (T 2−T 1)
IDEAL RANKINE IDEAL RANKINE w/ RANKINE w/ OFWH
CYCLE SUPERHEATING REGEN
Efficiency: Heat Added: Efficiency:
W net Q A =T ave ∆ S W net
e cycle= e cycle=
QA Enthalpy and Entropy: QA
( h1 −h2 )−( h4 −h3 ) h1=h@ p ∧T Heat Added:
e cycle= 1 1

h1−h4 ∆ S=S max −S min ¿ Q A =ms ( h1−h7 )


Heat Added: Heat Rejected:
Q A =ms (h 1−h4 )
Q R=(1−mes )(h3 −h4 )
Heat Rejected: RANKINE w/ OFWH Turbine Work:
Q R=ms (h2−h3 )
Turbine Work:
REGEN W HPT =ms ( h1−h2 )
Efficiency: W LPT =(1−mes ) ( h3−h 4 )
W T =ms ( h1 −h2 ) W net
e cycle= W TT =W HPT +W LPT
QA
W T =ms ( h1 −h2 )−∆ KE Pump Work:
Pump Work: Heat Added:
Q A =ms ( h1−h9 ) W P 1=(1−mes ) ( h5−h 4 )
W P=ms ( h 4−h3 ) W P 2=ms ( h7 −h6 )
Heat Rejected:
Approximate Pump Work: Q R=(1−mes )(h3 −h4 ) W PT =W P 1 +W P 2
Turbine Work: Work:
W P=v f 3 ( p4 − p3 )
W HPT =ms ( h1−h2 ) W net =W TT −W PT
Work: W LPT =(1−mes ) ( h2−h3 ) W net =Q A −Q R
W net =W T −W P W TT =W HPT +W LPT
Enthalpy and Entropy:
W net =Q A −Q R Pump Work: h1=h@ p ∧T (sprhtd )
1 1

Steam Rate: W P 1=(1−mes ) ( h5−h 4 )


h2 =h@ S ∧ p
W P 2=mes ( h 8−h7 )
2 2

ṁ 3600
SR= = h3 =ntrplt
P W net W PT =W P 1 +W P 2
Work: h 4=h f @ p condenser

Back Work Ratio:


WP W net =W TT −W PT h5 =W P 1+ h4
rb = ; W p >W T
WT
Enthalpy and Entropy: W net =Q A −Q R h6 =hf @ p extraction

h1=hg@ p boiler
Enthalpy and Entropy: h7 =W P 2+ h6
h2 =h@ p ∧S h1=h@ p ∧T (sprhtd )
2 2
1 1 h7 =v f 6 ( p7− p 6)+h6
h3 =hf @ p condenser
h2 =h@ S ∧ p
2 2
S1=S 2=S 3

h 4=w p +h3 h3 =ntrplt Extracted Steam:


h 6−h5
S2=S 1=S g @ p h 4=h f @ p mes =
boiler condenser
h 2−h5
h5 =W P 1+ h4 Optimum Pressure for Extraction:
p6 = p 2
h5 =v f 4 ( p5 −p 4 )+ h4
RANKINE w/ REHEAT h6 =h7 ; assume p6= p sat @T
Efficiency: 6

W net h7 =hf @ p
e cycle= extraction

Q AT h 8=W P 2+ h7
Heat Added: RANKINE w/ REHEAT
h 8=v f 7 ( p8− p 7)+h7
Q A =ms ( h1−h6 )
Q ARe =ms ( h3−h 2 ) S2=S 1=S @ P ∧T & OFWH REGEN
Efficiency:
1 1

Extracted Steam:
Heat Rejected: h9−h 6 e cycle=
W net
Q R=ms (h4 −h5 ) mes @ MC = QA
h8−h 6
Turbine Work: h7 −h5 Heat Added:
mes @ CFWH = Q A =ms ( h1−h8 )
h2 −h5
W HPT =ms ( h1−h2 )
Q ARe =( 1−ms ) ( h3−h2 )
W LPT =ms ( h3−h4 ) Q AT =Q A +Q ARe
Pump Work:
RANKINE w/ REHEAT
W P=ms ( h 6−h5 )
& CFWH REGEN Heat Rejected:
Q R=(1−mes )(h 4−h 5)
W P=v f 5 ( p6− p 5 ) Efficiency:
W net Turbine Work:
Work: e cycle=
QA W HPT =ms ( h1−h2 )
W net =W TT −W P Heat Added: W LPT =(1−mes ) ( h3−h 4 )
Q A =ms ( h1−h9 )
W net =Q AT −QR W TT =W HPT +W LPT
Q ARe =( 1−ms ) ( h3−h2 )
Enthalpy and Entropy: Pump Work:
h1=h@ p ∧T Q AT =Q A +Q ARe W P 1=(1−mes ) ( h6−h5 )
1 1

W P 2=ms ( h 8−h7 )
h2 =ntrplt wet vap S 2< S g
Heat Rejected: W PT =W P 1 +W P 2
h2 =hg ; S 2=S g Q R=(1−mes )(h 4−h 5)
satvap
Work:
h2 =h@ S ∧ p Turbine Work:
2 2
W net =W TT −W PT
W HPT =ms ( h1−h2 )
h3 =h@ p ∧T ; T 3 =T 1
3 3
W LPT =(1−mes ) ( h3−h 4 ) W net =Q AT −QR
h 4=ntrplt W TT =W HPT +W LPT
Extracted Steam:
h5 =hf @ p Pump Work: h 7−h6
condenser
mes =
W P 1=(1−mes ) ( h6−h5 ) h 2−h6
h6 =W p +h 5
W P 2=mes ( h 9−h8 )
S1=S 2=S @ p ∧T
W PT =W P 1 +W P 2
1 1

ACTUAL RANKINE Work:


CYCLE W net =W TT −W PT
Efficiency:
' W net =Q AT −QR
' W net
e =
cycle
QA
'
Extracted Steam:
Heat Added: h 8−h6
mes =
Q'A =ms ( h1−h'4 ) h2−h6

Heat Rejected:
Q'R=ms ( h'2−h3 )
Turbine Work:
'
W T =W T eT

Pump Work:
' WP
W P=
eP
W 'P=ms ( h'4 −h3 )

Work:
' ' '
W net =W T −W P
' '
W net =Q A −Q R

RANKINE w/ REHEAT &


(O/C) FWH REGEN

Extracted Steam:
h11 −h9
mes 1 @ CFWH =
h2−h9
h8−h7
mes 2 @ OFWH =(1−mes 1)
h4−h9
SINGLE STAGE COMPRESSOR TWO STAGE COMPRESSOR
Isentropic Compression Work: Compression Work:
W p V =−∆ H
k W saved=W wc−(W C 1 +W C 2 )

[( ) ]
k ( pd V d − ps V s ) n−1
W pV = k
1−k
W C 1=
n
n−1 ( )
psV s
px
ps
n
−1

[( ) ]
k−1
kp V pd W C 1=W C 2
W pV k = s s k
−1
1−k ps
W CT =2W C1
Isothermal Compression Work:
W pV =Q Intercooler Pressure:
p x =√ p s p d
Heat Rejected in Intercooler:
W pV = ps V s ln
( )
ps
pd Q x =m c p ( T x −T s )

W pV =ms R T 1 ln
( ) ps
pd THREE STAGE COMPRESSOR
Polytropic Compression Work: Compression Work:
W p V =Q−∆ H
n
W saved=W wc−(W C 1 +W C 2 +W c3 )

n ( p d V d −p s V s )

[( ) ]
n−1
W pV = n
1−n W C 1= ( )
n
n−1
psV s
px
ps
n
−1

[( ) ]
n−1
np V pd
W pV n = s s n
−1 W C 1=W C 2=W C 3
1−n ps
W CT =3W C 1
Actual Work:
' WC
WC=
eo
Intercooler Pressure:
Mechanical Efficiency: p x =√ p 2s pd
3

W IC p y = √ p s p2d
3
e m=
W BC
W IC
e m=
W IE
Heat Rejected in Intercooler:
Q x =m c p ( T x −T s )
Compression Efficiency: Q x =Q y