SmartX AS-P Server - SmartX Controller Specification Sheet
SmartX AS-P Server - SmartX Controller Specification Sheet
com/buildings | 1
Introduction
At the core of an EcoStruxure BMS is a SmartX server,
such as the SmartX AS-P server. The SmartX AS-P
server performs key functionality, such as control logic,
trend logging, and alarm supervision, and supports
communication and connectivity to the I/O and field
buses. The distributed intelligence of the EcoStruxure
BMS ensures fault tolerance in the system and provides
a fully featured user interface through WorkStation and
WebStation.
Features
The SmartX AS-P server is a powerful device that can
act as a standalone server and also control I/O The first Ethernet port is dedicated to the site network.
modules and monitor and manage field bus devices. In The second Ethernet port is fully configurable. The
a small installation, the embedded SmartX AS-P server second port can be configured to extend the site
acts as a standalone server, mounted with its I/O network so that various devices and clients can be
modules in a small footprint. In medium and large connected. Another option is to configure the second
installations, functionality is distributed over multiple port as a separate network, which means that the port
SmartX servers that communicate over TCP/IP. can host a private network or act as a client to a second
site network. This port configuration with dual networks
Communications hub requires hardware version 0.62 or higher. If the second
port is not used, it can be disabled.
Capable of coordinating traffic from above and below
its location, the SmartX AS-P server can deliver data
The USB device port allows you to upgrade and
directly to you or to other servers throughout the site.
interact with the SmartX AS-P server using Device
The SmartX AS-P server can run multiple control
Administrator.
programs, manage local I/O, alarms, and users, handle
scheduling and logging, and communicate using a
Using a USB Ethernet adapter, you can connect a
variety of protocols. Because of this, most parts of the
laptop PC to the USB host port and run Device
system function autonomously and continue to run as a
Administrator, WorkStation, and WebStation to
whole even if communication fails or individual
upgrade, configure, and access the SmartX AS-P
EcoStruxure BMS servers or devices go offline.
server. The USB host port can also be used to provide
power and communications for the AD touchscreen
Variety of connectivity options
display.
A SmartX AS-P server has numerous ports that enable it
to communicate with a wide range of protocols, Authentication and permissions
devices, and servers.
An EcoStruxure BMS provides a powerful permission
system that is easy to manage, flexible, and adapts to
A SmartX AS-P server has the following ports:
all kinds of system sizes. The permission system
provides a security level of the highest standards.
• Two 10/100 Ethernet ports Authentication is done against the built-in user account
• Two RS-485 ports management system or against Windows Active
Directory Domains. The built-in account management
• One LonWorks TP/FT port system allows an administrator to establish password
• One built-in I/O bus port policies that meet stringent cybersecurity guidelines.
When Windows Active Directory is used, the
• One USB device port administration costs are lower because users do not
• One USB host port have to be managed in multiple directories.
Auto-addressing
The auto-addressing feature eliminates the need for
setting DIP switches or pressing commission buttons.
Each module automatically knows its order in the chain
and assigns itself accordingly – significantly reducing
engineering and maintenance time.
Two-piece design
Specifications
Electrical
DC input supply power .............................................................................................................................................. 10 W
DC input supply voltage .........................................................................................................................................24 VDC
Environment
Ambient temperature, operating ..................................................................................................0 to 50 °C (32 to 122 °F)
Ambient temperature, storage ..............................................................................................-20 to +70 °C (-4 to +158 °F)
Maximum humidity.....................................................................................................................95 % RH non-condensing
Material
Plastic flame rating .............................................................................................................................................UL94-5VB
Enclosure ...............................................................................................................................................................PC/ABS
Ingress protection rating ............................................................................................................................................IP 20
Mechanical
Dimensions including terminal base ..................................................90 W x 114 H x 64 D mm (3.6 W x 4.5 H x 2.5 D in.)
a) See the BTL Product Catalog for up-to-date details on BTL listed firmware revisions on BACnet
International'shomepage.
Modbus .............................................................................................................................Modbus TCP, client and server
...........................................................................................................................................Serial, RS-485, master or slave
TCP................................................................................................................................................Binary, port fixed, 4444
HTTP ..................................................................................................................Non-binary, port configurable, default 80
HTTPS............................................................Encrypted supporting TLS 1.2, 1.1, and 1.0, port configurable default 443
SMTP ............................................................................................................Email sending, port configurable, default 25
SMTPS ........................................................................................................Email sending, port configurable, default 587
SNMP ...................................................................................................................................................................version 3
............................................................................................................................ Network supervision using poll and trap
............................................................................................................................Application alarm distribution using trap
Terminals
LNS
LNS version........................................................................................................................................................ OpenLNS
...............................................................................................................................................Installed on WorkStation PC
LonMark
Resource files version................................................................................................................................................14.00
CPU
Frequency ........................................................................................................................................................... 500 MHz
Type ......................................................................................................................SPEAr1380, ARM Cortex-A9 dual-core
Regulatory Notices
Federal Communications Commission CE - Compliance to European Union (EU)
FCC Rules and Regulations CFR 47, Part 15, Class B 2014/30/EU Electromagnetic Compatibility Directive
This device complies with part 15 of the FCC Rules. Operation is subject to the following two 2011/65/EU Restriction of Hazardous Substances (RoHS) Directive
conditions: (1) This device may not cause harmful interference. (2) This device must accept 2015/863/EU amending Annex II to Directive 2011/65/EU
any interference received, including interference that may cause undesired operation. This equipment complies with the rules, of the Official Journal of the European Union, for
governing the Self Declaration of the CE Marking for the European Union as specified in the
Industry Canada above directive(s) per the provisions of the following standards: EN 50491-1 Product
This Class B digital apparatus complies with Canadian ICES-003. Standard; EN 60730-1, EN 60730-2-11, and EN 50491-3 Safety Standards.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
Regulatory Compliance Mark (RCM) - Australian Communications and Media WEEE - Directive of the European Union (EU)
Authority (ACMA) This equipment and its packaging carry the waste of electrical and electronic equipment
This equipment complies with the requirements of the relevant ACMA standards made under (WEEE) label, in compliance with European Union (EU) Directive 2012/19/EU, governing the
the Radiocommunications Act 1992 and the Telecommunications Act 1997. These disposal and recycling of electrical and electronic equipment in the European community.
standards are referenced in notices made under section 182 of the Radiocommunications
Act and 407 of the Telecommunications Act.
UL 916 Listed products for the United States and Canada, Open Class Energy
Management Equipment. UL file E80146.
UL 864 Listed products for the United States. 10th Edition Smoke Control System.
UL file S5527.
www.schneider-electric.com