The EvoFlat is a compact flat station for heating single-family homes and apartments. It provides both direct heating and instantaneous domestic hot water using a self-acting temperature controller. The controller regulates the system to ensure a constant hot water temperature while minimizing energy losses. The flat station requires minimal space and has a durable stainless steel and copper construction.

Uploaded by

ahmed ewis
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
55 views2 pages

MSS Fully Insulated - 150423

The EvoFlat is a compact flat station for heating single-family homes and apartments. It provides both direct heating and instantaneous domestic hot water using a self-acting temperature controller. The controller regulates the system to ensure a constant hot water temperature while minimizing energy losses. The flat station requires minimal space and has a durable stainless steel and copper construction.

Uploaded by

ahmed ewis
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

MAKING MODERN LIVING POSSIBLE

EvoFlat MSS,
fully insulated
Flat station for single - family, semi - detached and terraced
houses as well as flats
Flat station for direct heating and instantaneous domestic hot
water. Innovative self-acting TPC – M controller for control of
heating and DHW temperature. Designed for wall mounting or built
in wall.
Application
The EvoFlat is a compact and simple regulated by the self-acting controller
to operate flat station. The EvoFlat is with integrated differential pressure
especially suitable for two-pipe sys- controller - the TPC - M. Supreme ease of
tems in residential buildings, which operation is obtained via the combined
are supplied from a secondary con- hydraulic and thermostatic regulation
nected district heating system, a block of the TPC - M controller. The flow - con-
heating system or a centrally located trolled part allows primary and sec-
boiler system. The EvoFlat is available ondary side flow through the heat ex-
as built-in variant with a recess box or changer, only when hot water is tapped FeATURES AND BENEFITS
as mount-on-wall variant. and blocks the flow immediately after
completion of the tapping process. The
Primary side (HS)
thermostatic part controls the domestic •• Flat station for decentralized heating
The flat station is prefabricated with hot water temperature. Thanks to the systems
interconnecting components such as quick-acting hydraulic control of the
a differential pressure controller (inte- •• Direct heating, DHW heating based
heat exchanger, it is largely protected on flow principle with thermostatic
grated in main temperature controller from the formation of lime scale and temperature controller
TPC -M ), strainer, sensor pockets and growth of bacteria. The TPC  -  M control-
fitting piece for insertion of a heat me- •• Innovative, energy-saving controller
ler with integrated differential pressure
ter. Thermostatic bypass is available as TCP - M in combination with high
controller compensates for variations performance heat exchanger for on-
an option. in supply temperature and varying dif- demand water heating without no-load
Heating (HE) ferential pressure and thereby ensures losses
a constant domestic hot water tempera-
The self-acting temperature controller •• Capacity: 15 kW HE, 55 kW DHW
ture at all times. For registration of the
TPC - M with integrated differential •• Minimum space required for installation
cold water consumption the EvoFlat is
pressure controller sets the optimum
equipped with a fitting piece for mount- •• Built-in or wall-mounted variant
operating conditions for heating and
ing of a cold water meter in the DCW
DHW. The mixing loop creates a suit- •• Pipes and plate heat exchanger made of
inlet. stainless steel
able temperature level e.g. for floor
heating. In order to enable a time Construction •• Plate heat exchanger in cupper brazed
dependent temperature control pro- All pipes are made of stainless steel. or gasketed version
gram, a zone valve with actuator and The connections are made by a newly •• Minimized risk of lime scale and bacteria
a room thermostat can be included as designed click connection, which does formation
an option. not need retightening
Domestic hot water (DHW) Insulation enabling the customer to have a fully
The domestic hot water is prepared The EvoFlat is built up on an EPP in- insulated substation, thus ensuring re-
in the heat exchanger based on the sulation back plate and a front insula- duced heat losses and excellent oper-
flow principle and the temperature is tion cabinet is available as an option, ating economy.

districtenergy.danfoss.com
EvoFlat MSS, fully insulated
Circuit diagram – example
2 Plate heat exchanger Danfoss
XB06H -1
5 Strainer 3/4” N/ N mv=0,6 mm
6 Non-return valve
10 Circ. pump HE Wilo Yonos Para
23 Sensor pocket 1 /2”
DHW 24 Fitting piece for energy meter
3/4” x 110 mm
29 Temp. sensor
DCW 30 Temp. controller
38 Hot Water Controller TPC - M
40 By-pass/circulation Danfoss
DCW FJVR (optional)
59 Fitting piece for water meter
3/4” x 110 mm
HS HE
Supply Supply

HS HE
Return Return

Design specifications: Connections:


610
Nominal pressure (prim/sec.): PN 6 / PN 10 1. Domestic cold water (DCW) inlet
Max. supply temperature: 95 °C 2. Domestic hot water (DHW)
DCW static pressure: Pmin = 1.5 bar 3. Domestic cold water (DCW) outlet
Brazing material (HEX): Copper 4. Primary side (HS) supply
Weight excl. cover: 14 kg 5. Primary side (HS) return
19 kg** 6. Heating (HE) supply
7. Heating (HE) return
580

Insulation: EPP λ 0.039


Options:
910

Cover: White-lacquered steel • Room thermostat


Electrical supply: 230 V AC • Actuator for zone valve
• Ball valves (60 mm)
Dimensions (mm):
• Ball valves with connection for pressure
With connections: H 590 × W 550 × D 150* gauge ¾“ (120 mm) incl. safety valve
* Depth incl. mounting plate 1 2 3 4 5 6 7 • Mounting rail for wall mounted variant
H 590 × W 590 × D 150** • Recess box for built-in variant incl.
** In gasketed versions mounting rail
Connections sizes: 590 550 • Bypass
DH, HE, DHW, DCW: G ¾“ ET (int. thread) • Isolated front cover
space 65 mm • DHW circulation
• Gasketed plate heat exchanger

DHW: Capacity examples Heating: Capacity examples


DHW Temperature Temperature Flow rate Flow rate Pressure loss Heating Total pressure Flow rate
Heating
capacity Type primary secondary primary secondary primary circuit Δt loss primary primary
capacity
[kW] [°C] [°C] [l/h] [l/h] [*kpa] [°C] [*kpa] [l/h]
37 1 65/19,1 10/45 707 910 16 10 20 9 430
37 1 65/22,4 10/50 762 796 18 10 30 3,5 287
45 2 65/17,6 10/45 833 1106 18 10 40 2 215
45 2 65/20,6 10/50 890 968 21 15 20 30 645
55,5 3 65/14 10/45 950 1365 41 15 30 9 430
53 3 65/15,8 10/50 950 1140 41 15 40 5 323
42 3 55/16,3 10/45 950 1033 41
* Energy meter not incl.
33,7 3 50/19,1 10/45 950 829 41 Type 1 = XB 06H-1 26 (plate heat exchanger)
37 G1 65/25 10/45 850 910 25 Type 2 = XB 06H-1 40 (plate heat exchanger)
37 G1 60/28 10/50 865 796 30 Type 3 = XB 06H+ 60 (plate heat exchanger)

* Energy meter not incl.

Danfoss Redan A/S · District Heating · Omega 7, Søften · DK-8382 Hinnerup · Denmark
Tel.: +45 87 43 89 43 · Fax: +45 87 43 89 44 · [email protected] · www.redan.danfoss.dk

VL.IQ.C3.02 © Danfoss 04/2015 DEN – SMT / PL