0% found this document useful (0 votes)
35 views3 pages

Diagnostic Examination

The document contains multiple choice questions about electrical safety and code. It asks about hazardous locations, flexible cords and cables, receptacle installation, temperature detectors in motor windings, the purpose of galvanizing steel conduit, insulated stranded wire terminology, first aid rescue techniques, floor plan elements, outdoor lighting fixture installation, troubleshooting an overheated cord, contact resistance and electric shock severity, premises wiring scope, wire insulation removal, disconnect switch function, cable types, and safety practices when working with energized equipment.

Uploaded by

Joshua Carl
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
35 views3 pages

Diagnostic Examination

The document contains multiple choice questions about electrical safety and code. It asks about hazardous locations, flexible cords and cables, receptacle installation, temperature detectors in motor windings, the purpose of galvanizing steel conduit, insulated stranded wire terminology, first aid rescue techniques, floor plan elements, outdoor lighting fixture installation, troubleshooting an overheated cord, contact resistance and electric shock severity, premises wiring scope, wire insulation removal, disconnect switch function, cable types, and safety practices when working with energized equipment.

Uploaded by

Joshua Carl
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 3

Which of the raceway methods is NOT  .

allowed to be used in a hazardous location?


A device actuated by the operation of some
 Rigid non-metallic conduit devices with which it is directly associated,
to govern succeeding operations of some or
Flexible cords and cables shall be used for allied devices.
the following applications EXCEPT:
 Fixed wirings  Relay
If an electrician does not understand the At least how many receptacle outlet(s) shall
instruction that were given by the be installed in the bathroom?
supervisor, which of the following is the
best for him to do?  1
 He asks that instruction be
repeated and clarified Some of the principal factors that affect the
operating temperature of a cable are the
Which type of temperature detector is used following EXCEPT one. Which one is this?
in motor windings?
 Resistance  Ventilation
Where galvanized steel conduit is used, the For better illumination you would provide
primary purpose of galvanizing in which one  .
of the following?
 It retards rusting An assembly drawing for a switchboard
appears to have some errors. As supervisor,
This is the term given to an insulated what steps will your take?
stranded wire.  Hold the job until you have
 Insulator checked with the person who
initiated the plans.
Employees shall be familiarizing themselves
with approved methods of ______ rescue Equipment to be installed shall be fully
techniques and fire extinguishment. specified in the name plate EXCEPT which
 First aid of the following considered optional?
 Power and speed ratings
In an electrical lay-out, floor plan shall
show Which of the following statements on
lighting fixtures NOT correct?
I. Plan for power  Outdoor lighting fixtures and
II. Plan for lighting and receptacle outlets associated equipment shall be
III. Plan for fire detection and alarm circuits permitted to be supported by trees.

 I, II and III An overheated cord often indicates\


 Corroded terminals and defective
To make sure that the voltage switchboard is cord
not energized, what final step should you
take for assurance?
If a bare live conductor is touched following factors should be considered, one
accidentally, the severity of electric shock is of which is the least important. Which one
determined primarily by is this?
 The contact resistance between the  Electrical insulation
bare wire and the person at the
point of contact The Philippine Electrical Code, Part 1 does
not cover wiring of equipment installed
within or to or from one of the following.
With respect to the safety value of the Which is one is this?
insulation on electrical maintenance tools, it  Airplanes
can be said properly that
 The insulation should not be used
as the only protective measure
When removing insulation from the wire
What type letter for conductors has a trade before making the splice,
name moisture resistant thermoplastic? care should be taken to avoid nicking the wir
 TW e (slightly cutting the wire) because of one
of the following. Which one of this?
Employees shall read _____ and warn others  The wire might break
who are in danger near energized equipment
or lines. The usual function of a disconnect switch in
 Warning signs and signals high voltages circuit is to
 Isolate from energized buses,
Which of the following premises wiring equipment which are not in service
installations is NOT covered in the scope of
the Philippine Electrical Code? Which of the following is NOT used as an
 Motor vehicles electrical cable?
 Steel cables
Which of the following is NOT one of the
considerations that must be evaluated in
judging the equipment?
 Arcing effects

A unit or assembly of units or sections and


associated fittings, forming a rigid structural
system used to support cables.
 Cable tray

An electrician should consider all electrical


equipment live unless he definitely knows
that they are not. The main reason of this
practice is to avoid
 Personal injury

In judging the suitability of an electrical


equipment for proper mounting, the

You might also like