0% found this document useful (0 votes)
18 views

ENHP

This document summarizes the specifications of the ENHP Series portable incremental encoder with a handle. It has a resolution of 100 pulses per revolution and outputs A and B phase signals. It can be used for numerically controlled or milling machinery. Features include an emergency stop switch and enable switch. The encoder operates with a power supply of 5VDC or 12-24VDC and has an IP67 rating for water and dust resistance.

Uploaded by

Eddy Sanchez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
18 views

ENHP

This document summarizes the specifications of the ENHP Series portable incremental encoder with a handle. It has a resolution of 100 pulses per revolution and outputs A and B phase signals. It can be used for numerically controlled or milling machinery. Features include an emergency stop switch and enable switch. The encoder operates with a power supply of 5VDC or 12-24VDC and has an IP67 rating for water and dust resistance.

Uploaded by

Eddy Sanchez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

ENHP Series

Portable Incremental type with Handle


Features
● Suitable for manual pulse input type such as
numerically controlled or milling machinery
● Emergency stop switch, enable switch are available
● Rotary switch for 6 Position, 4 Position
Application
● Industrial tooling machinery
Please read “Caution for your safety” in operation
manual before using.

Ordering information
ENHP 100 1 L 5
Series Pulse/1Revolution Clickstopper position Control output Power supply

Portable encoder 1 : Normal "H" T : Totem pole output 5 : 5VDC ±5%


100
with handle 2 : Normal "L" L : Line driver output 24 : 12-24VDC ±5%
※Line driver power is only
5VDC.

Specifications
Item Portable incremental type of rotary encoder with handle
Resolution(P/R) 100 _ _
Output phase A, B phase(Line driver output A, A, B, B phase)
Phase difference between A and B : _ ± __ (T=1cycle of A phase)
T T
Phase difference of output
4 8
BCD Code output
Rotary switch output
• Axis select switch(OFF, X, Y, Z, A, B) • Rate select switch(R1, R2, R3, R4)
• Low - Load current : Max. 30mA, Residual voltage : Max. 0.4VDC
• High - Load current : Max. 10mA,
Electrical specification

Totem pole output


Control Output voltage(Power voltage 5VDC): Min.(Power voltage-2.0)VDC
output Output voltage(Power voltage 12-24VDC): Min.(Power voltage-3.0)VDC
• Low - Load current : Max. 20mA, Residual voltage : Max. 0.5VDC
Line driver output
• High - Load current : Max. -20mA, Output voltage : Min. 2.5VDC
Response Totem pole output Max. 1㎲ • Measuring condition -
time Cable length : 1m,
(Rise/Fall) Line driver output Max. 0.5㎲ I sink = 20mA
Power supply • 5VDC ±5%(Ripple P-P : Max. 5%) • 12-24VDC ±5%(Ripple P-P : Max. 5%)
Current consumption Max. 40mA(disconnection of the load), Line driver output : Max. 50mA(disconnection of the load)
Max. Response frequency 10kHz
Insulation resistance Min. 100MΩ(at 500VDC megger between all terminals and case)
Dielectric strength 750VAC 50/60Hz for 1 minute(Between all terminals and case)
Connection 25Pin D-SUB of connector type
Starting torque Max. 1kgf·cm(0.098N·m)
Mechanical Shaft loading Radial : 2kgf, Thrust : 1kgf
specification Max. allowable
※1 Max. 200rpm(Normal), 600rpm(Peak)
revolution
Vibration 1.5mm amplitude or 300m/s2 at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 2 hours
Shock Approx. Max. 50G
Ambient temperature -10 to 70℃, storage : -25 to 85℃
Environment
Ambient humidity 35 to 85%RH, storage : 35 to 90%RH
ø5, 18-wire, Length : 8m, Spring code cable
Cable
(AWG28, Core diameter : 0.08mm, Number of cores : 18, Insulator out diameter : ø0.7)
※2
Protection IP67(IEC standards) for Box
Unit weight Approx. 730g
※1: Make sure that. Max response revolution should be lower than or equal to max. allowable revolution when selecting the resolution.
Max. response frequency
[Max. response revolution(rpm)= Resolution × 60 sec]
※2: It is protection for the rear case and the wiring part.
※Environment resistance is rated at no freezing or condensation.

F-46
Portable Incremental type with Handle
(unit: mm)
Control output diagram Dimensions (A)
Photo
<25-pin D-SUB electric
38 21.4 80 connector> sensor
Totem pole output Line driver output
25 14
Rotary encorder circuit Load connetcion Rotary encorder circuit Load connetcion

26
(B)
13 1 Fiber
+V +V Enable Emergency optic
sensor
switch stop switch
Sink current ※1 Axis select Rate select (C)
: Max. 30mA Load switch switch

Main circuit
Main circuit

150.5
Door/Area
+ Output + LED sensor
Output A phase

900
- _ -
indicator
※2 _
Output (D)
Source current A phase Proximity
: Max. 10mA Load sensor
0V

650
0V 34.8
(E)
_ _ Pressure
※The output circuits of A, B phase(Line driver output A, A, B, B phase) sensor
are the same.
※Totem pole output type can be used for NPN open collector output 75 (F)
Rotary
type(※1) or voltage output type(※2). encoder

Output waveform (G)


Connector/
Socket
ENHP-100-1-T- ENHP-100-2-T- ENHP-100-1-L-5 ENHP-100-2-L-5
(H)
T T T T Temp.

_T ± __
T _T ± __
T
controller

2 4 2 4 A Phase A Phase
_T ± __
T _T ± __
T
(I)
SSR/
A Phase _ 2 4 _ 2 4 Power
A Phase controller
A Phase A Phase
_T ± __
T _T ± __
T (J)
_T ± __
T _T ± __
T 4 8 4 8
Counter

4 8 4 8
B Phase B Phase
B Phase (K)
B Phase Timer
_ _
B Phase B Phase
(L)
Panel
meter
Clickstopper position(Normal "H") Clickstopper position(Normal "L") Clickstopper position(Normal "H") Clickstopper position(Normal "L")
(M)
※Clickstopper position Normal "H" or Normal "L" : It shows the waveform when the handles is stopped. Tacho/
※Encoder revolution direction : It is clockwise(CW) from the dial. Speed/ Pulse
meter

Connections (N)
Display
unit
HANDY PULSE GENERATOR COLOR SIGNAL 24P CONNECTOR
SHIELD F.G.
(PIN NO.) (O)
Sensor
YELLOW OUT A
__ ※1 1 controller
LT.VIOLET OUT A 2
ENCODER WHITE OUT B
__ ※2 3 (P)
CLEAR OUT B 4 ● AXIS SELECT Switching
mode power
BLACK 0V 5 supply
RED +V 6 BCD Code output
NC1 NC1
Axis Pin Pin Pin (Q)
GREEN E-STOP1 8 No.15 No.14 No.13
Stepper
motor&
Emergency LT.GREEN E-STOP2 9 OFF 0 0 0 Driver&Controller
stop switch NC2 NC2
PINK E-STOP2 22
X axis 0 0 1 (R)
GRASS GREEN E-STOP2 24 Graphic/
Enable switch Y axis 0 1 0 Logic
VIOLET ENABLE 10 panel
R1 Z axis 0 1 1
Rate select switch R2 A axis 1 0 0 (S)
Field
R3 BCD B axis 1 0 1 network
Code BROWN FEED RATE 11 device
R4
출력 LT.BROWN SELECT 12
OFF (T)
Software
Axis select switch X ● RATE SELECT
Y BCD Code output
BCD ORANGE 13
Z AXIS Rate (U)
Code LT.BLUE 14 Pin No.12 Pin No.11 Other
A 출력 SELECT
BLUE 15 R1 0 0
B
R2 0 1
LT.YELLOW BCD COMMON 16 R3 1 0
2.4kΩ, 1/2W
GRAY LED(+) 18 R4 1 1
LED
_ _indicator
※1: Totem pole output does not have A, B output signal.
※COMMON terminal(Pin No. 16) of Axis select switch and Rate select switch is common.

F-47

You might also like